AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2 Highly Efficient,Powerful Heating and Cooling.
Highly Efficient operation The EER(Energy Efficiency Ratio) on these models is greatly improved by revised design specifications and by being manufactured stringently to Mitsubishi Electric high quality standards. High sensible cooling capacity The sensible cooling capacity has been significantly improved through balanced optimised heat exchanger design. Flexible Installation (Convertible Airflow) The customer can select whichever side flow and down flow in the PRHG series. The standard specification is side flow. Also the PRHG series can install more flexible in local work, too. Labor Saving Installation Because of the single unit configuration, all refrigeration work can be omitted. The unit operation can commence immediately after connection to the power supply, drain piping, ducting and control system. Minimum Floor Space The PRHG series feature a compact design and has been succeeded in reducing more floor space. Flexibility of Supply Air Delivery All series feature belt driven Supply Air fans enabling accurate matching of actual airflow rates to the specified quantities. Accurate commissioning is assisted by the capability to exchange pulleys and belts if necessary to achieve the desired air balance. Comfort heating The PRHG series are designed to provide effective heating even when the outside temperature is down to - C. Economizer (Special Order) In the PRHG series, Economizer is prepared as special order. The Economizer can save energy while moving Economizer damper. Please consult your local Mitsubishi Electric Sales office for application advise on these control. Features Typical Installation Example PRHG Wide Electrical Control Capability All series is flexible mechanical control configulation. In addition Global Remote Controller is prepared on standard. The Global Remote Controller give the programmable weekly timer, compressor anti-short cycle timer(3 min), cool/heat/fan/auto changeover etc. This controller utlises a microprocessor and includes liquid crystal display with touch pad for adjustment for control program. The factory standard is for provision of 24volt terminal block to enable a field wired control of contractors choice to be connected. Please consult your local Mitsubishi Electric Sales office for application advice on these control. Global Remote Controller Low Ambient Cooling Kit (Special order) In applications with relatively high internal loads, there may be a requirment for all series to operate on cooling at low ambient conditions. An optional accessory is available to maintain the refrigeration circuit in balance at outdoor temperatures as low as -5 C. Please consult your local Mitsubishi Electric Sales office for application advice on this accessory.
SPECIFICATIONS Model name PRHG-8MYA PRHG-MYA PRHG-MYA PRHG-20MYA Service reference PRHG-8MYA PRHG-MYA PRHG-MYA PRHG-20MYA Power supply 3N~ 380 ~ 4V 50Hz kw 23.8 29.7.3 60.8 Total cooling capacity Btu/h 81,200 1,400 8,000 207,500 (Gross) kcal/h 20,500,600 39,900 52,300 kw 19.0 23.8 37.0 48.6 Sensible cooling capacity Btu/h 64,900 81,200 126,300 165,900 (Gross) kcal/h 16,400 20,500 31,900 41,800 kw 23.0 32.0 45.5 61.2 Total heating capacity Btu/h 78,600 9,0 5,0 208,700 (Gross) kcal/h 19,800 27,500 39,0 52,600 Capacity steps % 0-0 0-50-0 Refrigerant R-22 Refrigerant charge kg 4.7 5.6 2x4.7 2x5.6 Refrigerant control Capillary tube External finish Acrylic resin coating Color MUNSELL 5Y8/1 Height mm 1,000 1,200 Dimension Width mm 1,300 1,990 Depth mm 1,530 1,800 Net weight kg 385 4 700 800 Compressor Hermetic line start (reciprocating) No. x Motor output kw 5.5 7.5 2x5.5 2x7.5 Indoor coil Cross fin coil Indoor fan Centrifugal (galvanized steel) - belt drive Indoor fan motor Three phase cage induction motor No. x Motor output kw 1.1 1.5 2.2 3.7 CMM 80 0 160 190 Indoor fan air flow CFM 2,826 3,532 5,651 6,7 L/S 1,333 1,667 2,667 3,167 External static pressure mmaq 20 Pa 0 200 Outdoor coil Cross fin coil Outdoor fan Propeller - direct drive Outdoor fan motor Three phase cage induction motor No. x Motor output kw 0.55 2x0.55 CMM 160 320 fan air flow CFM 5,651 11,302 L/S 2,667 5,333 Drain connection mm.4 Sound pressure level db(a) 66 70 High pressure switch, fuse Protection devices Over current relay (compressor, indoor fan and outdoor fan) Internal thermostat (compressor and outdoor fan motor) Note 1. Cooling & Heating capacity is based on the following conditions. Cooling : Indoor:27 CDB, 19 CWB ; Outdoor:35 CDB Heating : Indoor:21 CDB ; Outdoor:7 CDB, 6 CWB 2. Refrigerant charge volumes are factory charged. 3. Capacity is gross capacity which do not include a deduction for evaporator fan motor heat. 4. The measuring point of the Sound pressure level is 1m from the unit surface. 5. The range of working voltage is with in ±% voltage of power supply. 6. Specification subject to change without notice.
Outline Dimensions PRHG- 8MYA PRHG-MYA (side flow) (1342) 60 0 0 0 0 0 0 60 20 49 1300 51 51 7 20 173 4-X Mtg. holes B A A Detail 1342 1300 1392 duct flange 60 0 0 0 0 0 0 20 duct flange 60 00 36 170 170 36 49 20- ø3 Holes 20- ø3 Holes Screw for earth connection 7 20 173 31 265 00 265 Hanger (4 places) (1342) 7 20 173 230 192 Supply air B Detail 00 412 Return air Control box Drain R 1 135 71 50 437 30 Wiring hole 58 5 87 (down flow) 637 281 Screw for earth connection 45 372 226 832 242 1300 51 View C (Bottom view) 51 4-X Mtg. holes B 265 00 265 A 1342 A Detail 1300 1392 (1342) 58 49 160 160 160 160 160 160 49 Screw is accessory parts. Accessory parts is attached on control box cover. 372 140 140 281 duct flange 368 38 49 160 160 320 160 160 49 19- ø3 Holes 832 Screw R washer Spring washer T. Lock washer 96 160 160 160 160 96 41 0 0 duct flange 261 (1342) 40 812 16- ø3 Holes Hanger (4 places) B Detail Drain R 1 00 Control box Wiring hole 71 437 9 30 9 C
Outline Dimensions PRHG-MYA PRHG-20MYA (side flow) 1990 51 1744 123 A 1990 2032 2082 A Detail (2032) 72 200 200 200 200 200 200 200 200 72 1744 34 49 & Duct flange 428 34 120120 120 123 (2032) 26- ø3 Holes 51 4-X Mtg. holes 235 1330 235 B B Detail Screw for earth connection 123 1744 123 Hanger (4 places) 428 51 Supply air Control box 123 1744 123 1200 428 169 Return air 77 124 483 Drain R 1 Wiring hole 50 1800 (down flow) 717 359 79 372 4 1782 4 View C (Bottom view) Screw for earth connection 294 1432 264 51 1990 51 4-X Mtg. holes B 235 1330 235 A 1990 2032 2082 A Detail (2032) (2032) 1782 91 200 200 200 200 200 200 200 200 91 372 140 140 duct flange 368 1762 1432 86 180 180 180 180 180 86 180 180 24- ø3 Holes 359 59.5 120 120 59.5 duct flange 339 22- ø3 Holes 1412 Hanger (4 places) B Detail Control box 1200 77 8 483 8 Drain R 1 1800 C Wiring hole Screw is accessory parts. Accessory parts is attached on control box cover. Screw R washer Spring washer T. Lock washer
Out Look PRHG- 8MYA PRHG-MYA PRHG-MYA PRHG-20MYA Operation Range The range of working temperatures is as below. Make sure which unit you are using and confirm the range of application. Outdoor temp. ( C DB) 50 40 30 20 Cooling Range for continuous operation - 0 cooling parts as option -5 - - 20 24 30 20 27 30 Indoor temp. ( C WB) Range for continuous operation Use for low ambient (Note) As an applicable humidity outside standard for both indoors and outdoors, we recommend use within a range of 35-80% relative humidity. However, it is a condition that there is no be dewy in surfaces of electric parts. Outdoor temp. ( C WB) 5 0-5 Heating Indoor temp. ( C DB) Range for continuous operation Caution The use of your air conditioner outside the range of working temperature and humidity can result in serious failure.
Special Order Description Model PRHG-8MYA PRHG-MYA PRHG-MYA PRHG-20MYA Service ref. PRHG-8MYA PRHG-MYA PRHG-MYA PRHG-20MYA * Low Ambient Cooling parts PAC-205FC * Economizer Near future Pressure Gauge Roof curve Air filter Near future * Low Ambient cooling It is possible to conduct cooling operation under an outdoor temperature even down to -5 C. * Economizer The Economizer can save energy while moving Economizer damper in low ambient temperature.
HEAD OFFICE MITSUBISHI DENKI BLDG.MARUNOUCHI TOKYO 0-0005 TELEX J24532 CABLE MELCO TOKYO Issued in Oct. 2000 MEE00K023 Printed in Malaysia New publication effective Oct. 2000. Specifications subject to change without notice.