UNIJET CAR PARK VENTILATION SYSTEM

Similar documents
SMOKE CONTROL - NEW DIRECTIONS

Emergency Extract Ventilation

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Tunnel Axial Flow Fan

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

Actionpac 60/120 (LNS Standard)

Car Park Ventilation 1

POWERPLUS SPP Product Brochure

Actionpac LNS3 Intelligent Damper Control and Monitoring System

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

Mechanical smoke ventilation systems. CI/SfB 37.4 Xy

TUNNEL FANS STANDARD AND HOT SMOKE

Jet fans JET FANS FANS FOR CAR PARK VENTILATION AUO / ARO / AUP / ARP AUZ/ AUT / ART / CGF

Smoke extract fan SMHA HATCH

V3 Intelligent Damper Control and Monitoring System

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

CRU 200 and 500 Series Condensate Recovery Units

APPLICATION DATA SHEET

JM Aerofoil Fans Bulletin JMA60-05

Colt ventilation systems for car parks, loading bays and service areas

AXIAL & JET FANS FOR TUNNEL VENTILATION

Systemair product news - Fans NEWS

APPLICATION DATA SHEET

An introduction to... Sigma

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 and 4 Fire System

Technical Information

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Selecting the Correct Fan

Smoke Vents. Certified to CE EN Roof Access Systems

Centrifugal Fans, Non-Overloading, Backward Inclined

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Subject Description Form

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

TOPAZ ADIABATIC COOLER

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TopVent Design Handbook

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

Unit heater with accessories

FUME EXTRACT STRATEGY STATEMENT

A. Codes and Standards that are Standard at the University:

Colt Car Park Ventilation Systems. Smoke Control

GS100M Gas Detector. Technical Specification

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

October 2013 Bespoke Intelligent Damper Control and Monitoring System

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

DAVITS INFORMATION & CERTIFICATION

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Guide Specifications

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Industrial Ventilation

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

INPUT / OUTPUT MINI MODULES

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

The Elevator Control System

REVO JOB INSTALLATION AREA. REVO Job SELECTION TABLE MAIN FEATURES OF THE PRODUCT PROFESSIONAL. CE marking. Automatic filter cleaning

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

The Experts in Vacuum Solutions

PARTICULATE EMISSION MONITORING

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Fill Point, Level Gauges, and Control Range

Specification Data. General:

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

VENT TREX. Product Guide

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

Air Handling Units. Real HVACR people who understand your needs.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Protect your investment with Safety Manager

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

DCS-100. intelligent damper control & monitoring system

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Reliably Advanced Extinguishing Control

and Maintenance Services Daily Contract Cleaning

Myth & Reality of Basement Ventilation

Healthy. Atmosphere. for Pigs and Poultry. for a

PFS Single stage axial fan The axial fan for modern boiler plants

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Sentinel Demand Energy Recovery Ventilation

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

Transcription:

Overview Discharge to Atmosphere UniJet is a packaged car park ventilation system designed to provide smoke clearance and pollution ventilation to covered car parks to comply with current building regulations and also meeting the standards set out in BS7346 Part 7 (2006) Specifically impulse ventilation to achieve smoke clearance Jet Fan Ground Level System Description The UniJet car park ventilation system delivers combined pollution and smoke clearance using jet fans to provide an energy efficient and safe solution whilst requiring the least possible plant spac The system comprises high temperature extract fans to exhaust smoke and pollution to atmosphere with strategically positioned jet or impulse fans used to move stale air or smoke to the extract fan positions. Fully automatic controls monitor carbon monoxide levels and smoke or temperature conditions within the car park to operate the fans at the appropriate level to maintain safe and comfortable conditions within the car park. Underground level 1 Underground level 2

System Components Extract Fans Impulse Fans Outlet grill Main extract plant comprises run and standby axial flow fan units. All fans are tested to the latest internationally recognised standard IS05801 Part 1, installation category D for aerodynamic performance and BS848 Part 2 (1985) for acoustic performanc The adjustable pitch Aerofoil impeller gives the exact performance required, with a non overloading fan characteristic. The impellers are all high pressure die cast to offer thin aerofoil sections for low generation of nois The maximum pitch angles allow for speed control by frequency inverter. The motors are suitable for inverter speed control down to 20% of full speed. Fans are tested in compliance with high temperature test standard directive 89/106/EEC to EN 12101-3 and are rated to one off emergency operation at 300 C for 1 hour. Cylindrical Silencers (Optional) Casings are of rolled, pre-galvanised sheet steel with spun end rings incorporating tapped inserts for fixing. Suitable fixing screws are provided with all steel silencers. The absorbent material is acoustic grade mineral fibre with an erosion resistant facing. It is protected and contained by a pre-galvanised perforated steel sheet formed to match the fan diameter. High efficiency axial flow fan with adjustable blades to achieve the required performanc The fan unit is fitted with inlet and outlet silencers to give minimal operational noise levels. Deflector vanes are fitted to the fan outlet to guide the airflo Fan motors are asynchronous flange type and can be single or two speed. The fans are delivered as a complete unit housed in an attractive oval casing for quick and easy installation. All jet fans are high temperature units to maintain operation in fire conditions. Control System The control system is an intelligent PLC based modular control system using an ASi (Actuator Sensor Interface) network for operation of field hardware and Ethernet communications network for the HMI user interfaces in the cores and fire control centr The system can also be interfaced with the BMS system to provide status indication for fans i.e running/failed, fan speed via a 0-10V signal and alarm/active location. Motorised backdraft shutters Silencer Fan Silencer Modular car park smoke clearance system Plant Room access doors Inlet grill

System Components (Continued) Motor Control Centre The MCC contains all the necessary hardware to provide automatic operation of the system, including variable speed drives for all fans (for daily vent mode only), automatic changeover and can be interfaced with the fire detection system. Automatic control of the car park ventilation system is facilitated by CO monitoring that continually checks the air quality within the car park. CO heads are mounted throughout the car park to ensure that all areas are protected. The fire mode function of the system is activated by the fire detection system. The run signals are relayed to the fan control panels through local interface units to initiate the required sequence of operation of the induction fans and main extract fans. Primary and secondary power supplies will ensure continuous operation of the system during primary mains failur Automatic changeover is incorporated into the plant room control panels to switch the power supplies in the event of primary supply failur The fan control panel will accept two incoming 3 phase power supplies (by others) providing automatic change over in the event of primary mains failur The secondary supply shall be capable of providing a continuous source of power for a minimum period of 2 hrs with the system operating at full load. The extract fan control panel provides the control & monitoring of the entire car park extract system. The panels can be externally wall mounted in an IP55 enclosur Operation of the fans is monitored by current sensing so that in the event of fan failure the standby fans are automatically started. All extract & impulse fans will be inverter controlled by the extract fan control panel to reduce starting currents and allow for adjustment of volume flow rates to achieve the required exhaust duty at the point of extrac CO Detector The Tocsin 103 series of gas detectors are designed for cost effective safe area gas detection solutions. They incorporate microprocessor technology to give a stable 4-20mA process signal output or digital addressable outpu The addressable output option allows detectors to be networked on a single cable run giving dramatic reduction in installation costs. The in built processor can be used to pre-calibrate the sensor prior to installation. Alternatively calibration can be achieved on site via the control panel or locally using a handheld PC device or laptop. A range of sensing technologies can be incorporated into the housing to provide the most appropriate detection method. Electrical Wiring The electrical wiring for the system shall be provided in fireproof cable with a CWZ classification. Fan Cabling Controls Cabling CO Detection Cabling All cabling will be installed in accordance with the Electrical Wiring Regulations. FP400 or equivalent FP200 or Equivalent CY Screened or equivalent Standard Solutions For a quick and easy estimation of what you need for your car park use the following guide to ascertain how many fans, plant areas, and power requirements in minutes. Call our engineering team for costs or further assistance and we ll be happy to help. Four easy steps to protecting your car park 1. Decide what level of protection you need. If you re unsure please call us on 0870 240 6460 2. Calculate the floor area of your car park. 3. Use the chart overleaf to plan your installation g. plant room space, required inlet area etc. If your car park area falls outside the range of the table please contact our engineering team for a bespoke proposal. 4. Contact our projects team for an instant quote and a price list for future us We can even provide you with our unique Carparkulator wheel to make it even easier for you to design and cost car park ventilation systems.

TOTAL FLOOR AREA OF CAR PARK NO. OF JET FANS EXTRACT FAN DIAMETER PLANT ROOM MINIMUM DIMENSIONS (MM) OPENING AREA (FREE AREA) A B C D E F (h x w) G CONTROL PANEL DIMENSIONS 750 2 500 Ø 4700 2500 2100 1500 3100 1500 x 650 1.42m 2 1000h x 800w x 250d 1000 3 630 Ø 5100 2800 2100 1500 3500 1500 x 850 1.9m 2 1000h x 800w x 250d 1250 4 710 Ø 5400 3000 2100 1500 3800 1500 x 1100 2.4m 2 1200h x 1200w x 400d 1500 5 800 Ø 5600 3200 2100 1500 4000 1500 x 1300 2.85m 2 1200h x 1200w x 400d 1750 5 800 Ø 5600 3200 2100 1500 4000 1500 x 1500 3.35m 2 1200h x 1200w x 400d 2000 6 900 Ø 5900 3500 2100 1500 4300 1800 x 1400 3.8m 2 1200h x 1200w x 400d 2250 7 900 Ø 5900 3500 2100 1500 4300 1800 x 1600 4.3m 2 1200h x 1200w x 400d 2500 7 1000 Ø 6200 3800 2200 1500 4600 1800 x 1800 4.75m 2 1200h x 1200w x 400d 2750 8 1000 Ø 6300 3800 2200 1600 4600 1800 x 1950 5.25m 2 1200h x 1200w x 400d 3000 9 1000 Ø 6400 3800 2200 1700 4600 1800 x 2150 5.75m 2 1600h x 1000w x 400d 3250 9 1120 Ø 6700 4200 2300 1700 4900 1800 x 2300 6.2m 2 1600h x 1000w x 400d 3500 10 1120 Ø 6800 4200 2300 1800 4900 1800 x 2500 6.7m 2 1600h x 1000w x 400d 3750 10 1120 Ø 6900 4200 2500 1900 4900 1950 x 2450 7.15m 2 1600h x 1000w x 400d 4000 11 1250 Ø 7200 4400 2500 1900 5200 1950 x 2650 7.65m 2 1600h x 1000w x 400d 4250 12 1250 Ø 7300 4400 2500 2000 5200 1950 x 2800 8.1m 2 1800h x 1200w x 400d 4500 12 1250 Ø 7400 4400 2500 2100 5200 1950 x 2950 8.6m 2 1800h x 1200w x 400d 4750 13 1250 Ø 7500 4400 2500 2200 5200 1950 x 3000 9.05m 2 1800h x 1200w x 400d

Plant Room Standard Arrangement

What is included in your quotation: Unless confirmed in writing, this is what we provide: Optional additional cost items: Builders work by others: Project management to our ISO9001 procedures, including provision of design drawings, method statements and risk assessments Electrical containment Power supplies Construction of suitably fire rated plant room Forming and weathering of discharge openings in plant room Field wiring, identification and testing Additional system demonstrations Chasing out walls and making good All cables, junction boxes and flex outlet plates. Smoke tests Termination and connection of field wiring to position of control panels and field devices Collateral warranties On completion of commissioning, we provide 1 day of demonstration to approving authorities Attendances by others: Standard limited warranty period Material off loading and safe storage First year s maintenance of system to comply with requirements of fire safety legislation External hoisting and positioning of roof-mounted equipment Welfare facilities Task lighting and 110V power Safe access equipment, hoisting, craneage or scaffolding