Fresh water modules premium-line

Similar documents
Installation instructions

Build on Uponor with Aqua Port Central. Central fresh domestic hot water stations for private homes, hotels and healthcare

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

Winterhalter STF Bavaria. Single-tank flight-type glasswasher for beer mugs and glasses. Powerful performance in large-scale operations

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

KEMPER ThermoSystem. For further information on KTS use the QR code!

ROTEX Sanicube: Combination of Hot water storage tank and Instantaneous heater. ROTEX Sanicube - The hygienic hot water storage tank. The heating!

English. Heating with logs & wood pellets 20-40

Solar Technology. CPC and Sunnyline. collectors. makes you independent. Pelletskessel.

Natural geothermal energy

Thermostatic mixing valves with replaceable cartridge for centralized systems

ROTEX gas hybrid heat pump. A strong team.

Increase the attractiveness of your multi-family building

Simple solutions are usually the best...

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

Top Performance the efficiency of washing

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

TAH / TBH / TCH Series

WOLF GAS CONDENSING BOILERS COMFORTLINE

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

TAH / TBH / TCH Series

DK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS

Gas condensing boiler (wall mounted) TopGas

KLUDI. Electronic fittings for bathroom and kitchen

Hot water wherever and whenever you need it

FREQUENTLY ASKED QUESTIONS

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

REMKO Comfort-WP The versatile heat pump

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

ETA Buffer Storage Tank and Hydraulic Module. Systematic heat distribution. The energy concept from a single source.

Create the right atmosphere with renewables

Heating with pellets kw

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Innova new M2 and M3 series

Hot water on demand with incorporated energy saving function

Renewable energies. Ready-made OEM systems for manufacturers of Solar thermal systems Solid fuel boilers (pellets, split logs, wood chips ) Heat pumps

Gas fittings, blower and control from a single source

High-output calorifier Modul-plus

Electronic Water Treatment Systems. Environmental Protective Technology

Gas condensing boiler UltraGas

ROTEX HPDU monobloc Maximum efficiency in water heating

FV 40.2 Premium Class Glass and dishwashing machine

Log fired heating system

Product Range kw

Viega Profipress. Press technology made of copper. Always a fitting solution.

WZS series. Hot water circulation systems for energy storage tanks

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS

Plug-in refrigeration units

new.11 The new Weishaupt products

Storage systems. Solarbayer. Fire protection insulation ISO B1

Technical information for installation and operation

english language Product catalogue 09/18 Storage tanks are our element

makes you independent Solar Technology

A new age in HEATING. Storage tank. ROTEX Sanicube The natural way to save energy! The complete heating system

GASOKOL TANK SYSTEM COMPACT, HYGIENIC, FUNCTIONAL, HIGH-PERFORMANCE

KONDRAIN KONDRAIN HP. Condensate Drains. Intelligent condensate drainage up to 350 bar. Rev 03_ EN

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

ultra The Ultimate Sensor Faucet

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

ECO AIR/WATER HEAT PUMP For new buildings, low-energy and passive houses

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

Helios in a new dimension.

TopGas Wall Hung Condensing Gas Boiler

All you get is clean

Hydraulic compactors

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Solar heating systems

REMKO HYBRID HEAT PUMPS

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

sustainable energy solutions

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Installation & Technical Guide. Domestic & Commercial.

HERZ ECO-Line Heating with logs or wood pellets

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Pure Function. All you need. Pure&Easy. Pure&Solid. Pure&Style

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Peace of milk S M A R T M I L K C O O L I N G

In cooperation with. sustainable energy solutions

The finest fruit processing

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

SANCO. Once you've used SANCO you'll never use anything else. [GB] SANCO. KME Germany GmbH & Co. KG

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

4 liter Solo and 8 liter Combi

gas condensing combi boiler

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

30% Take lead on your project with an efficient system concept. lower energy.

C L E A N G R E E N. The whole world of Spülboy. Glass washers and accessories for professional washing

Biomass Pellet Boilers

HSHP HIGH PERFORMANCE DRUM HEATER

Heating with wood pellets kw

Efficient heating that won t cost the earth

Refrigeration Dryers TG TI Series

Transcription:

Fresh water modules premium-line Hygienic hot

Hot water hygienic and convenient FRESH WATER SYSTEM A freshwater module heats drinking water in accordance with the instant hot water principle, only when it s needed. In contrast to a traditional hot water tank or boiler, potable water is not used to store energy - and stored as hot water for hours or days at a time. Only when hot water is needed is it heated to the desired temperature with the aid of a stainless steel plate heat exchanger. Stockpiling over the course of days is now a thing of the past. Buffer flow Hot water Circulation Cold water The energy for heating drinking water is supplied by a buffer tank, which can be heated by various systems by solar power units as well as by a pellet boiler, woodfired boiler, traditional oil/gas boiler, heat pumps or other systems. High-efficiency pumps ensure the right volume flow from the buffer to the stainless steel plate heat exchanger. Heating water FWM konvent Fresh water module Buffer return Buffer tank 2

Premium components makes macht you independent unabhängig Freshwater modules are subject to strict quality requirements, defined in DIN 1988. The material must not negatively impact the water quality, even over longer periods. The SOLARFOCUS freshwater modules consist of materials that fulfil these requirements. The pipework is made of stainless steel and its material quality is in line with the most stringent requirements for drinking water systems. The drinking water circuit is equipped with piston valves made of gunmetal and enables easy operation even over longer periods. The cover made of EPP with a beautifully designed plate can be form-fit secured on the base plate. The freshwater modules are equipped with copper-soldered plate heat exchangers as standard. If the water qualities are more aggressive, a nickelsoldered plate heat exchanger can be used. If necessary, ask for the water qualities datasheet. 80 Die schnelles off quickly Absterben langsames Die off alowly Absterben 70 kein No growth Wachstum 60 langsames Slowly Wachstum growth 50 optimales Optimum 40 Wachstum growth 30 langsames Slowly Wachstum growth langsames Wachstum kein 20 Wachstum No growth (Legionellen (Legionelladormant) schlafen) 55-60 C: Hot water tank 35 C: Showering 10 C: Cold drinking water When legionella fall on fertile ground Flawless drinking water is pure and completely free from anything that is harmful to health. It contains germs such as legionella, which are not harmful at the normal levels of concentration. However, if drinking water is stored at a temperature range of 25-50 C for an extended period, these germs proliferate extensively and represent a health risk. These germs can then enter your lungs as aerosols via a shower or whirlpool. Once in the lungs, they can result in dangerous infections, in particular in children, older people or people already experiencing health problems. Freshwater modules heat drinking water to the desired temperature only it is needed, in accordance with the instant hot water principle. The days of stockpiling hot water are a thing of the past. Hot water, freshly tapped hygienic and convenient. Accumulation of legionella (L. pneumophila) magnified with the aid of the electron microscope (TEM). One bacterium is approximately 0.003 mm long. Image: Hans R. Gelderblom, Rolf Reissbrodt / Robert Koch Institute 3

Choose your module Fresh water module FWM eco Featuring the basic equipment, best suited for systems with buffer tank temperatures of up to 60 C. The ideal price/performance ratio. Fresh water module FWM konvent The electronic controller of this module also guarantees a constant hot water temperature and low return flow temperature in the tank, even with differing tapped quantities and buffer temperatures. Fresh water module FWM autark No electronic pump and control needed. The direct connection of the cold water turbines with the pump also guarantees a constant hot water temperature and low return flow temperature in the tank, even with differing tapped quantities and buffer temperatures. 4

makes you independent The Technology: l Freshwater module with high-efficiency pump and flow switch l No control needed l Circulation and premix valve can also be integrated l Output capacity 20 and 30 l/min Your benefit: l A cost-efficient entry-level model with premium components l With the basic equipment, best suited for systems with buffer tank temperatures of up to 60 C l The option of circulation that can also be integrated guarantees hot water quickly, even through long pipes The technology: l Freshwater module with electronically controlled high-efficiency pump l Circulation and premix valve can also be integrated l Optional for SOLARFOCUS eco manager-touch or with separate control l Output capacity 20, 30, 40 and 50 l/min Your benefit: l The electronic control guarantees a constant hot water temperature and low return flow temperature in the tank, even with differing tapped quantities and buffer temperatures l Ideal for combination with solar power systems and biomass boilers l Easy adjustment possible on the touch-display using the SOLARFOCUS biomass boiler l The option of circulation that can also be integrated guarantees hot water quickly, even through long pipes The technology: l Freshwater module with cold water turbines and directly flange-mounted pump l No electronic pump or control needed l Wear-free and wear-optimised magnetic coupling l Output capacity up to 28 l/min, regardless of the pipe pressure The benefit: l The direct coupling of the cold water turbines with the pump guarantees a constant hot water temperature and low return flow temperature in the tank, even with differing tapped quantities and buffer temperatures l No electrical connected load required l Save electricity costs, as the pump is driven from the cold water pipeline pressure l Ideal for combination with solar power systems and biomass boilers l The option of circulation that can also be integrated guarantees hot water quickly, even through long pipes 5

Fresh water module FWM eco Info 3 A cost-efficient entry-level model with premium components 3 With the basic equipment, best suited for systems with buffer tank temperatures of up to 60 C. 3 No controller needed 3 Option of integrating circulation and premix valve 3 Output capacity 20 and 30 l/min The quality entry-level model Conform with DVGW The FWM eco combines simplicity with premium components. The drinking water is heated in accordance with the instant hot water principle, by means of a stainless steel plate heat exchanger. First, the water is heated up when it is needed just in time. This means that fresh, hot and perfectly hygienic water is always available. Stockpiling large quantities of hot water is a thing of the past. 1 4 6 7 8 9 Simply technology A flow switch registers when hot water is being tapped and switches the high-efficiency pump on. The speed of the high-efficiency pump is set to the desired temperature once, when the system is first started, by means of an installed thermometer. No control is required. The FWM eco, with the basic equipment, is best suited for systems with buffer storage temperatures of up to 60 C. 3 2 Equipment 5 10 1 Stainless steel plate heat exchanger 2 High-efficiency pump 3 230 V flow switch 4 Flow buffer tank 1 OT 5 Return flow buffer tank 1 OT 6 Cold water input 1 OT 7 Hot water output 1 OT 8 Ventilation valve 9 Circulation connection 10 Premix valve connection 6

makes you independent Comfort plus+ For even more convenience, the freshwater module can also be equipped with a premix valve and a circulation line, which can be integrated. The option of circulation that can also be integrated guarantees hot water quickly, even through long pipes, and the circulation can be adapted to individual needs. Technical data Fresh water module FWM eco Output capacity/heath pump at 50 C buffer flow FWM eco 20 30 20 30 Buffer flow [ C] 60 60 50 50 Cold water input [ C] 10 10 10 10 Hot water output [ C] 45 45 45 45 Output capacity [l/min] 20 30 11.7 21 Return flow temperature to the buffer [ C] 21 21 24.3 24.8 Output max. [kw] 49 73 28 51 Weight [kg] 18.6 20.5 18.6 20.5 Electr. supply [V] 230 Connections ["] 1" OT Conn. circulation ["] 1" OT Height/Width/Depth [cm] 85/49/27 TIP: Install the fresh water module as close as possible to the buffer tank, so that you avoid losing energy. 7

Fresh water module FWM konvent Info 3 Freshwater module with an electronically controlled high-efficiency pump 3 Optional for SOLARFOCUS eco manager-touch or with independent control 3 Ideal for combination with solar power systems and biomass boilers 3 Circulation and premix valve that can also be integrated optional 3 Output capacity 20, 30, 40 and 50 l/min The perfect solution Conform with DVGW The fresh water module FWM konvent combines premium components an with intelligent controller. In order to be able to guarantee a consistent output temperature at the hot water tap, even with differing tapped quantities and buffer temperatures, the rotary speed of the volume flow from the buffer is regulated using a high-efficiency pump with the aid of a powerful controller. The controller receives the information required to regulate the system from a volume flow sensor or a volume flow encoder and extremely fast temperature sensors, which are able to record the smallest deviations in temperature immediately. 4 6 7 8 9 13 The adjustments to the volume flow from the buffer, and the very good heat transfer in the stainless steel plate heat exchangers, mean that the return flow temperatures in the buffer are very low. The low return flow temperature ensures ideal operating conditions in solar power systems, heat pumps or condensing boilers. An optimum level of efficiency is guaranteed. 1 12 14 3 11 9 10 5 2 Equipment 1 Stainless steel plate heat exchanger 2 Speed-regulated high-efficiency pump 3 Volume flow sensor/ volume flow encoder 4 Buffer tank flow 1 OT 5 Buffer tank return flow 1 OT 6 Cold water input 1 OT 7 Hot water output1 OT 8 Ventilation valve 9 Rinse and purging valves for drinking water 10 Controller (eco manager-touch / separate) 11 Premix valve (optional) 12 Circulation (optional) 13 Rinse and purging valve, circulation 14 Safety valve, 8 bar, circulation 8

Shared controller for your heating system makes you independent In order to avoid your heating area accumulating an unnecessarily high number of controllers from a wide variety of manufacturers controllers that do not all communicate with each other the eco manager-touch controller of the SOLARFOCUS biomass boiler can take over control of the FWM konvent. The colour 7 touch display makes operation incredibly easy. When connected to the internet and the mysolarfocus app, you can also access your heating system s most important settings using your smartphone. If you do not have eco manager-touch controller, but are interested in FWM konvent there s an answer. The freshwater modules are also available with separate button-based controller, located on the FWM. Comfort plus+ For even more convenience, the freshwater module can also be equipped with a premix valve and a circulation line, which can be integrated. The option of circulation that can also be integrated guarantees hot water quickly, even through long pipes, and the circulation can be adapted to individual needs. Technical data Fresh water module FWM konvent Output capacity/heat pump at 50 C buffer flow FWM konvent 20 30 40 50 20 30 40 50 Buffer flow [ C] 60 60 60 60 50 50 50 50 Cold water input [ C] 10 10 10 10 10 10 10 10 Hot water output [ C] 45 45 45 45 45 45 45 45 Output capacity [l/min] 20 30 40 50 11.7 21 28 35 Return flow temperature to the buffer [ C] 21 21 21 21 24.3 24.8 25 26 Output max. [kw] 49 73 98 122 28 51 68 85 Weight [kg] 18.6 20.5 21.3 22.7 18.6 20.5 21.3 22.7 Electr. supply [V] 230 Connections ["] 1" OT Conn. circultation ["] 1" OT Height/Width/Depth [cm] 85/49/27 TIP: To avoid energy loss, install the freshwater module as close as possible to the buffer tank. 9

Fresh water module FWM autark Info 3 Freshwater module with cold water turbines and directly flange-mounted pump 3 No electronic pump or control needed 3 No electrical connection line needed 3 Ideal for combination with solar power systems and biomass boilers 3 Output capacity of up to 28 l/min, regardless of the flow pressure No electrical current needed The FWM autark is the highlight in the area of freshwater technology. In contrast to traditional freshwater modules, the FWM autark does not need any electrical current of any type in order to operate, either to push the volume flow from the buffer water over the plate heat exchanger, or for the controller. Conform to DVGW 3-fold patented Hot water is created purely using pipeline pressure, with the aid of a cold water turbine, which is connected directly with the pump. This also means that a constant hot water temperature is guaranteed even with differing tapped quantities and buffering temperatures. 5 7 8 10 9 In this way fresh, hot and perfectly hygienic water is always available. Stockpiling large quantities of hot water is a thing of the past. 1 10 3 2 4 Equipment 1 Stainless steel plate heat exchanger 2 Cold-water turbine with a flange-mounted heating pump 3 Thermal mixing valve to set the hot water temperature 4 Hydraulically control non-return valve 5 Buffer tank flow 1 OT 6 Buffer tank return flow 1 OT 7 Cold water input 1 OT 8 Hot water output 1 OT 9 Ventilation valve 10 Rinsing and purging valves, drinking water 6 10

makes you independent Simply brilliant brilliantly simple When hot water is tapped, the turbine wheel in the cold water pipe starts the turn. The turbine wheel is connected with the pump wheel on the buffer side directly by means of magnetic coupling, and pushes the volume flow out of the buffer via the heat exchanger. Drinking water side: Cold drinking water flows through the turbine wheel (2) and the heat exchanger (1), where it is heated in line with the counter-flow principle. If more hot water is tapped, the turbine wheel also turns more quickly. This means that a constant water temperature can be guaranteed even with differing tapped quantities and buffer temperatures, without using an electronic controller. The desired hot water temperature is set using a thermal mixing valve. The adjustments to the volume flow from the buffer, and the very good heat transfer in the stainless steel plate heat exchangers, mean that the return flow temperatures in the buffer are very low. The low return flow temperature ensures ideal operating conditions in solar power systems, heat pumps or condensing boilers. An optimum level of efficiency is guaranteed. 2 1 Buffer side: Hot heating water is transported through the pump (2) to the mixing valve (3). The premixed water flows through the heat exchanger (1) and heats up the drinking water in line with the counter-flow principle. Comfort plus+ For even more convenience, the freshwater module can also be equipped with an external circulation line for integration into the buffer tank. The option of circulation guarantees hot water quickly, even through long pipes, and can be adapted to your individual needs. 1 2 3 Technical data Fresh water module FWM autark Output capacity [l/min] 15 20 26 28 Buffer flow [ C] 60 60 60 60 Cold water input [ C] 10 10 10 10 Hot water output [ C] 45 45 45 45 Required flow pressure [bar] 3.5 4 5.4 6 Pressure drop through the modulel [bar] 2 2.5 3.2 3.4 Connections ["] 1" OT Height/width/depth [cm] 85/49/27 Weight [kg] 23.6 TIP: Install the freshwater module as close as possible to the buffer tank, so that you avoid losing energy. The required flow pressure is calculated as follows: pressure drop through the module + pressure drop via the fittings. The flow pressure must be measured at the point at which the largest consumer is used (bathtub). 11

makes you independent Innovative products, which protect the environment and relieve the purse. PREMIUM PREMIUM up to years Guarantee Guarantee according to guarantee pass Everything from one supplier Solar systems Biomass heating Storage technology Fresh water technology Tested state-of-the-art technology EN ISO 9001 certified EN 303-5 CEN/TC 57 Your specialised dealer SOLARFOCUS GmbH Werkstraße 1 A-4451 St. Ulrich/Steyr e-mail: office@solarfocus.com Tel.: +43 (0) 7252 / 50 002-0 web: www.solarfocus.com Fax: +43 (0) 7252 / 50 002-10 Subject to technical modifications, typesetting and printing errors. The images used are symbolic photos. All use is prohibited without the written consent of the copyright holder SOLARFOCUS. SOLARFOCUS GmbH 04/2016