T8 LED Tube. Plug & Play. Applications. Key Features. General Usage. 5years

Similar documents
LED Tube T8 Plug & Play-E-Ballast only

TRUELITE LED TUBE.

Corn Light. Applications. Key Features. General Usage. 5years

LED T5 - LINEAR REPLACEMENT TUBE DIRECTFIT COATED GLASS SERIES UL TYPE-A


LED T5 - LINEAR REPLACEMENT TUBE DirectFit COATED GLASS SERIES

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

LED ECO PANEL.

WZ-T8-W18 T8 LED Tube Light

Reflector T2 and GU10 6,000 hours

WARRANTY LED ECO PANEL.

LED ECO PANEL.

LED ECO PANEL.

TROFFER RETROFIT KIT (TRK)

LED ECO PANEL.

WARRANTY LED ECO PANEL.

LED LIGHTING Clay Street, Suite 550, Oakland, CA us.renesola.com v

Technical Application Guide for PHILIPS LED Lamps

CANADA LED PRODUCT REPLACEMENT GUIDE

Dimmable LED Retrofit Kit

LED Panel Light E830J

Tomorrow, at the speed of light. Long-lasting, energy-saving LED retrofit lamps

Tomorrow, at the speed of light. Long-lasting, energy-saving LED retrofit lamps

LED RETROFIT SOLUTIONS

LED Luminaire Selection Guide

1 General Description

LED LIGHTING Clay Street, Suite 550, Oakland, CA us.renesola.com NATIONAL ASSOCIATION OF ELECTRICAL DISTRIBUTORS

High Lux Performance White LED MR16 Lamp

E10 & L9 Low Wattage Light Cone Data

ReneSola LED Lighting. Over 400+ LED Lighting. Industrial Commercial Residential Hospitality

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

NATIONAL ASSOCIATION OF ELECTRICAL DISTRIBUTORS ASSOCIATE MEMBER

LED ROUND MINI PANELS

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

The Commercial LED Lighting Specialist

THINTEK G2 PANEL.

THINTEK G2 PANEL.

Leader in LED Lighting ULcUL Standard

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

LED Panel Light Specification List

The Commercial LED Lighting Specialist

NATIONAL ASSOCIATION OF ELECTRICAL DISTRIBUTORS ASSOCIATE MEMBER

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

LED HIGH BAY LINEAR ECO SERIES

Catalog # Project. Comments. Prepared by

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Product Specifications

LED Linear Design Highlights


Lum. Flux** [lm] 6500 K 1700 lm

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

P Archie. Incandescent NAME: PROJECT: Diameter: 5-3/4 Height: 8-3/4 Overall ht. w/stem: 75

LED PAR Lamps PAR20, PAR30, PAR38 SERIES

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

Atlas LED Light Fixture 1

New LED Product Offerings

LED FLAT PANEL EDGE LIT MLFP SERIES G2

The Commercial LED Lighting Specialist

BAS SFP22 Edge-lit LED Panel

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

LED LIGHTING Clay Street, Suite 550, Oakland, CA us.renesola.com NATIONAL ASSOCIATION OF ELECTRICAL DISTRIBUTORS

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

RES West Coast Valued Partner Meeting September 27, 2018 Joe Calnan RES National Account Manager

LED Ceiling Light. Informations. Application notes. Application Areas PS-AL W(-D,-S) Indoor

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

FPLHB - Fidelux Premier Linear Highbay

AOD LED Panel Light AL-PL

LED RETROFIT CONVERSION KITS

ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit

Technical application guide

Ivalo Lumaris LED Linear Lighting

Technical application guide

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

120V 12V LED LAMPS. Proven LED performance, superior savings and a broad range of options for landscape lighting systems

Ivalo Lumaris LED Linear Lighting

Ivalo Lumaris LED Linear Lighting

SECTION INTERIOR LIGHTING

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Greenough Enterprises Co., Ltd.

Energy Efficient Lighting Systems

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

Premium. Universal LED Vapor Tight T20G. Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy

Lamps & Lighting Electronics Catalogue

Transcription:

T8 ED Tube The ReneSola T8 ED Tube with its Plug and Play power, makes installation much easier. With 100+ compatible ballasts, all you have to do, is take the old lamp out and put the new 100+ l/w energy efficient ED lamp in. no rewiring or high cost of labor and no need to throw out a completely good working ballast you put in few months back. at a fraction of the wattage, get more light output of your existing system. Applications Key Features Environmentally friendly; free of mercury, UV and IR emissions Up to 60% energy savings compared to traditional T8 fluorescent lamps High Efficacy, increased energy saving Replaces existing fluorescent T8 lamps without removing the electronic ballast Eliminating the need for rewiring; allowing the fixture to maintain original U compliance Instant start; does not flicker or buzz Suitable for damp locations Offices Hospitality Retail Shopping Malls Restaurants General Usage Ideal replacement of Fluorescent T8 & T12 tubes 5years Warranty CRI (Ra) >80 PF >0.9 Non-Dimmable 50000h IP 20 40 ~ -20 4000K ON 20.000 3500K 5000K

T8 ED Tube T8 ED Tube Specification Model Base Watt(W) Dimmable Beam Angle( o ) umens(lm) CCT(K) Body Material RT8012AU0102 G13 15 No 4000 RT8012AU0103 G13 15 No 5000 RT8018X0401 G13 15 No 5000 RT8018X0403 G13 18 No 2100 4000 RT8018X0405 G13 18 No 2100 3500 Glass Glass PC+1/2A PC+1/2A PC+1/2A Ordering Guide Model UPC NO. Size (mm) Single Net Weight (Kg) Carton Dimension(mm) Carton Volume (M 3 ) Gross Weight of Carton (Kg) Quatity in Carton (Pcs) RT8012AU0102 842262101473 1270*210*215 0.057 6.05 25 RT8012AU0103 842262101480 1270*210*215 0.057 6.05 25 RT8018X0401 842262100056 RT8018X0403 842262100049 RT8018X0405 842262100032 Compatibility Chart Compatible only with the ballasts listed below so far, if you intend to install ballast compatible tube with ballasts not listed below, risk of damage or losses may occur. ReneSola disclaims liability for any damage or losses by not following the instructions in this document. Compatibility subject to change as additional ballasts are tested. If you do not see your ballast on the list, Please contact ReneSola. ist of Tested Ballasts Item Manufacturer Dimmer Model Item Manufacturer Dimmer Model Item Manufacturer Dimmer Model 1 KEYSTONE KTEB-232RIS-1-TO-S 8 QTP 3*32T8/UNV ISN-SC 15 QTP 3*32T8/UNV ISN-SC 2 ACCUPRO AP-432IP-UNV 9 QTP 4*32T8/UNV ISN-SC 16 QTP 4*32T8/UNV ISN-SC 3 PACIFIC EB-232IS-120-RES 10 QHE 1*32T8/UNV ISN-SC 17 PHIIPS ADVANCE ICN-1P32-N 4 WORK HORSE WH3-120- 11 QHE 2*32T8/UNV ISN-SC 18 PHIIPS ADVANCE ICN-2P32-N 5 WORK HORSE WH3-120- 12 QHE 3*32T8/UNV ISN-SC 19 PHIIPS ADVANCE ICN-3P32-N 6 QTP 1*32T8/UNV ISN-SC 13 QHE 4*32T8/UNV ISN-SC 20 PHIIPS ADVANCE ICN-4P32-N 7 QTP 2*32T8/UNV ISN-SC 14 QTP 2*32T8/UNV ISN-SC 21 PHIIPS ADVANCE IOPA-1P32-N

T8 ED Tube T8 ED Tube Compatibility Chart ist of Tested Ballasts Item Manufacturer Dimmer Model Item Manufacturer Dimmer Model Item Manufacturer Dimmer Model 22 PHIIPS ADVANCE IOPA-2P32-N 51 UNIVERSA B332IUNVHP-A (Triad) 80 GE GE432MAX-N/UTRA 23 PHIIPS ADVANCE IOPA-3P32-N 52 UNIVERSA B432IUNVHP-A (Triad) 81 QHE 1x32T8/UNV IS-SC 24 PHIIPS ADVANCE IOPA-4P32-N 53 UNIVERSA B132IUNVHE-A (UTIM) 82 QHE 2x32T8/UNV IS-SC 25 GE GE-132-MV-N 54 UNIVERSA B232IUNVHE-A (UTIM) 83 QHE 3x32T8/UNV IS-SC 26 GE GE-232-MV-N 55 UNIVERSA B332IUNVHE-A (UTIM) 84 QHE 4x32T8/UNV IS-SC 27 GE GE-332-MV-N 56 UNIVERSA B432IUNVHE-A (UTIM) 85 GE GE-132-MAX-H/UTRA 28 GE GE-432-MV-N 57 KEYSTONE KTEB-432-UV-IS-N-P 86 GE GE-232-MAX-H/UTRA 29 GE GE432MAX-G-N 58 HOWARD INDUSTRIES EP3/32IS/MV/MC/HE 87 GE GE-332-MAX-H/UTRA 30 GE GE232MAX-G-N 59 PR0UME EP232IS//MV/HE(Halco) 88 GE GE-432-MAX-H/UTRA 31 GE GE432-120RESDIYB 60 SUNPARK U-1/32ISE-HBF 89 QHE 1x32T8/UNV PSN-MC 32 GE GE432-120RES-DIY 61 SUNPARK U-2/32ISE-HBF 90 QHE 2x32T8/UNV PSN-MC 33 GE GE432MAXP-H/UTRA 62 SUNPARK U-3/32ISE-HBF 91 QHE 3x32T8/UNV PSN-MC 34 GE GE132MAX-/UTRA 63 SUNPARK U-4/32ISE-HBF 92 QHE 4x32T8/UNV PSN-MC 35 GE GE232MAX-/UTRA 64 QHE 2x32T8/UNV PSH-HT 93 UNIVERSA B132IUNVHP-N 36 GE GE332MAX-/UTRA 65 QHE 3x32T8/UNV PSH-HT 94 UNIVERSA B232IUNVHP-N 37 GE GE432MAX-/UTRA 66 QHE 4x32T8/UNV PSH-HT 95 UNIVERSA B332IUNVHP-A 38 GE GE432MAXP-/UTRA 67 Universal B232IUNVHP-B(Triad) 96 UNIVERSA B432IUNVHP-A 39 GE GE432MV-N-42T 68 QHE 2*59T8/UNV IS-SC 97 UNIVERSA B132IUNVHE-A 40 PHIIPS IOP-1PSP32-SC 69 PHIIPS ADVANCE IOP-1PSP32-W-SC 98 UNIVERSA B232IUNVHE-A 41 PHIIPS IOP-2PSP32-SC 70 PHIIPS ADVANCE IOP-2PSP32-W-SC 99 UNIVERSA B332IUNVHE-A 42 PHIIPS IOP-3PSP32-SC 71 PHIIPS ADVANCE IOP-3PSP32-W-SC 100 UNIVERSA B432IUNVHE-A 43 PHIIPS IOP-4PSP32-SC 72 PHIIPS ADVANCE IOP-4PSP32-W-SC 101 SUPERIOR IFE 70204 44 PHIIPS IOP-4P32-W-N 73 GE GE132-MVPS-N 45 PHIIPS REB-1P32-SC 74 GE GE232-MVPS-N 46 PHIIPS REB-2P32-SC 75 GE GE332-MVPS-N 47 PHIIPS REB-3P32-SC 76 GE GE432-MVPS-N 48 PHIIPS REB-4P32-SC 77 GE GE132MAX-N/UTRA 49 UNIVERSA B132IUNVHP-A (Triad) 78 GE GE232MAX-N/UTRA 50 UNIVERSA B232IUNVHP-A (Triad) 79 GE GE332MAX-N/UTRA

T8 ED Tube T8 ED Tube Dimensions Photometry G13 Illuminance-Distance Curve 15W G13 Illuminance-Distance Curve 18W Internal Connection Diagram Installation Guide ampholder ampholder ED Tube Fluorescent Fluorescent N AC ~ Switch Electronic Ballast ED T8 ED T8 1. Danger-risk of shock-disconnect power before installation. 2. Remove diffuser ( if provided). 3. Remove the existing fluorescent lamps from the luminaire 4. 4. Install the ReneSola ED T8 Instant Fit/Compatible lamp (one for each fluorescent lamp removed). 5. Replace diffuser (if removed in step 2). 6. Switch on power to the luminaire. CAUTION If the lamp or the luminaire exhibits any problems during operation (buzzing, flickering, etc.) immediately turn off the power, remove the lamp from the luminaire and contact the manufacturer. Risk of fire do not install in pre-heated luminaire; suitable for use in dry or damp locations; can be used with or without a diffuser. This product may cause interference with radio equipment and should not be installed near maritime safety communications or other critical navigation or communication equipment operating between 0.45-30MHz. These devices are not intended for use with emergency exit features of emergency exit lights. This lamp only operates with electronic ballasts. If the lamp does not light up when the luminaire is energized, remove the lamp from the luminaire and contact the manufacturer or a qualified electrician.

T8 ED Tube T8 ED Tube Other Information Minimum operating temperature: -20 C U/CU & DC listed, FCC compliant, RoHS compliant Suitable for use in open luminaries (fixtures) Suitable for use in damp locations This device is not intended for use with emergency exit fixtures or emergency lighting Turn off power before changing lamp This lamp is not compatible with photo controls, occupancy sensors, or timing devices This lamp is not suited for totally enclosed fixtures Risk of electric shock. Do not use where directly exposed to water For more Information, please contact 5650 Tomken Road, Unit 14. Mississauga ON 4W 4P1 www.renesola.ca +1(877)685-5137 Follow us www.renesola.ca All Rights Reserved. Specifications are subejct to change without prior notice.