CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Similar documents
CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

anti-condensation valve

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Convertible radiator valve for one-pipe systems, centre distance 35 mm

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

DISCALDIRT deaerator-dirt separator

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Mercury Mixing Kit (Code: ME1053)

Composite under-boiler dirt separator with magnet DIRTMAG

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Installation, commissioning and servicing instructions

caleffi hydronic valves page 1 of 12

Thermostatic mixing valves with replaceable cartridge for centralized systems

Systems for central heating

DIRTCAL - DIRTMAG dirt separator

geothermal march 2011

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Description of functions

Thermostatic mixing valves with interchangeable cartridges

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

TS RD 7761 RD, 7761 RD

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Protection and Control of Solid Fuel Boilers

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Dynamic thermostatic radiator valves DYNAMICAL

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

Index. Operating Instructions. Installation Instructions

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

INSTALLATION AND OPERATING INSTRUCTIONS

DEVIATING VALVES ART K063

Light oil / kerosene burner

Description of functions

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Light oil - kerosene burner

Design and Construction Standards SECTION PLUMBING EQUIPMENT

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

REV.01 /

LOVATO T-FIRE MODUL T-FIRE MODUL L TRENNSYSTEM / SEPARATION UNIT HOLZKESSELS PELLETS BOILER PELLETKESSEL WOOD BOILER DESCRIPTION ADVANTAGES

Wood Boiler Plumbing Schematics

Light oil burners. One stage operation

Roth fixed-value control set with high-efficiency pump

Baxi Maxflow Combi WM

CALEFFI. SEP4 combination hydraulic, air, dirt and magnetic separator series 01249/13.1 NA. Replaces 01249/13 NA. Function.

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Installation and maintenance instructions

AVTI Multifunctional self - acting controller

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Thermostatic valves with radiator connection systems

MCL-BIO. Fuels. Main features. multifuel biomass boiler. group of companies

TP /4-A-F-A-BQQE 400D 50HZ

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

USER MANUAL 9kW LILLY PELLET STOVE

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

maximise the sun s energy with warmflow solar Warmflow Solar

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Trade Product List 2013 BIOMASS ACCESSORIES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

SECTION PLUMBING EQUIPMENT

HERZ Differential Pressure Control Valve 4002

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Transcription:

Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution unit enables the connection of the solid fuel generator to the user system (direct or with inertial storage). It controls the return temperature to the generator to avoid condensation, by means of the built-in thermostatic sensor. Keeping the generator at a high temperature prevents condensation of the water vapour contained in the flue gas. It can be used both on boilers and residential generators such as fireplace heating systems, thermostoves and thermocookers. The anti-condensation recirculation and distribution unit gives the generator a longer life and ensures greater efficiency. The compact unit incorporates a circulation pump, an anticondensation thermostatic sensor, a natural circulation clapet valve, the temperature gauges and is equipped with an insulation shell. Product range Code 80.. Anti-condensation recirculation and distribution unit size DN 5 ( and /4 ) Code 80.. WYP Anti-condensation recirculation and distribution unit with high-efficiency pump size DN 5 ( and /4 ) Technical specifications Head available at the unit connections Materials H (m w.g.) (kpa) Body: brass EN 98 CB75S Obturator locking nut: brass EN 64 CW64N Unions: brass EN 65 CW67N Ball built into the unions: brass EN 64 CW64N Obturator: PSU Spring: stainless steel EN 070- (AISI 0) Clapet valve: PPS Seal elements: EPDM RS 4- Performance Medium: water, glycol solutions Maximum percentage of glycol: 50% Max. recommended flow rate: m /h Max. working pressure: 0 bar Working temperature range: 5 00 C Temperature gauge scale: 0 0 C Connections: and /4 F (ISO 8-) with union G (m /h) Power consumption Speed n P I (rpm) (W) (A) 050 65 0,8 650 45 0,0 00 0 0, Anti-condensation valve Setting temperature (Tset): 45 C, 55 C, 60 C, 70 C Setting accuracy: ± C By-pass complete closing temperature: Tmix=Tset +0 C=Tr Pump Three-speed pump: model RS 4- High-efficiency pump: YONOS PARA 5/6 Electric supply: 0 V - 50 Hz Max. ambient humidity: 95% Max. ambient temperature: 80 C Protection class: - RS 4- IP 44 - YONOS PARA 5/6 IPX4D H (m w.g.) (kpa) 7 70 YONOS PARA 5/6 Note: The YONOS PARA pump can operate with proportional pressure control, which adapts the performance to the system requirements. For further details, see the installation instruction sheet of the pump supplied in the package. G (m /h)

Technical specifications of insulation Material: EPP Mean thickness: 0 mm Density: 45 kg/m Working temperature range: 5 00 C Thermal conductivity: 0,07 W/(m K) at 0 C Reaction to fire (UL94): class HBF Dimensions Wooden biomass and condensation build-up Wooden solid fuel contains a variable moisture percentage depending on the type (logs, pellets, woodchips etc.) and seasoning. Water vapour is released during the solid fuel drying phase inside the combustion chamber. The presence of cold zones in the generator or flue gas chimney can lower the temperature of the flue gas down to the dew point, causing condensation to occur. Water vapour condenses on the generator surfaces, together with soot and part of the unburnt hydrocarbons contained in the flue gas, producing deposits and tar. These substances stick to the walls of the generator, covering most of the inner surfaces. In addition to being dangerous due to its flammability, tar is damaging to the integrity of the generator and limits the efficiency of the flue gas-system water exchanger. By keeping the generator walls at the highest possible temperature, the anti-condensation recirculation and distribution unit limits the formation of these substances, thereby increasing the combustion efficiency, controlling the emissions into the environment and prolonging the generator life. Flue gas and emission control SF M H Code completion Setting 45 C 55 C 60 C 70 C 4 5 6 7 Accumulation of ash and residues Primary and secondary air: Combustion efficiency SR ANTI-CONDENSATION RECIRCULATION AND DISTRIBUTION UNIT Zones of condensation forming: Deposits and tar Corrosion Reduction in heat exchanger efficiency Flammability Characteristic components Hydraulic diagram Flow by-pass Flow by-pass Return to generator System return Return to generator ) Anti-condensation thermostatic sensor ) Three-speed pump/ high-efficiency pump ) Natural circulation clapet valve System return 4) Union with built-in ball valve 5) Temperature gauge housing 6) Insulation Anti-condensation thermostatic sensor Three-speed pump/ high-efficiency pump Natural circulation clapet valve Union with built-in ball valve Temperature gauge

Operating principle The thermostat (), completely immersed in the medium, controls the movement of an obturator () that regulates the flows in by-pass () and toward the system. At the start-up of the heat generator, the recirculation unit recirculates the flow water so as to bring the generator up to temperature as quickly as possible (fig. ). When the flow temperature exceeds the setting of the anti-condensation valve Tset, the unit s cold port (4) starts opening to produce the water mixing Tmix: in this phase the system loading begins (fig. ). When the return temperature to the generator Tmix is greater than the setting of the anti-condensation valve by approximately 0 C, the by-pass port () closes and water returns to the generator at the same temperature as the system return (fig. ). In the event of pump stop (5), the clapet valve (6), which is closed due to the thrust of the pump during normal operation, allows natural circulation of the medium, by-passing the anti-condensation valve () in order to dissipate heat and prevent the temperature in the generator from reaching high levels that could be dangerous for the system safety (fig. 4). Tset SYSTEM START UP TRANSIENT by-pass open system return closed Tset, Tmix= > Tset START OF SYSTEM LOADING by-pass open system return open > Tset, Tr < Tset, Tmix=Tset Tmix > Tset + 0 C SYSTEM LOADED by-pass closed system return open > Tmix > Tset +0 C, Tmix=Tr Pump OFF Natural circulation clapet valve open Natural circulation of the medium 4 Tr Tmix Tset = Flow temperature Tset = Anti-condensation setting temperature Tmix = Mixed water temperature of generator return Tr = System return temperature 4

Construction details Single casting and reversibility The compact brass single casting, that houses the pump and functional components, enables immediate installation of the device, either on the right or left of the solid fuel generator, respecting the flow directions as shown. The temperature gauges can be extracted from the housings and re-inserted in the same position on the back side of the unit. Brass body The brass body prevents the formation of ferrous residues in the system, thereby helping to prolong the life of the heat generator. Anti-condensation valve The device incorporates a thermostatic sensor to control the temperature of water returning to the solid fuel generator so as to prevent condensation. The sensor has been specifically realised to be removed from the valve body for maintenance or replacement if necessary. Natural circulation clapet valve The function of this clapet device is to ensure natural circulation of the medium in the event of pump stop due to an electric power failure. When the pump is active, the thrust of medium keeps the valve closed, forcing the water to flow through the anti-condensation thermostatic valve. In the event of pump stop, when the water within the generator is at high temperature, a natural circulation of the water begins, by-passing the anticondensation valve, thus preventing the temperature in the generator from reaching dangerous high levels. Installation The anti-condensation recirculation and distribution unit can be installed on both sides of the generator respecting the flow directions indicated on the body. Installation is only allowed on the return to the generator in mixing mode, in vertical position (axis of the pump horizontal and axis of the thermostatic sensor vertical). This permits the full mechanical and hydraulic functionality of the natural circulation clapet valve. Installation on right side of generator Clapet - lock Before installation, it is necessary to remove the screw that keeps the clapet valve closed. This screw is factory supplied screwed in order to prevent breakage during transport. Removing the protective screw ensures the full functionality of the clapet valve as a natural circulation device. To do this, unscrew the union located on the mixed water outlet port of the unit and access the screw inside the valve body, unscrewing it using a cross-tip screwdriver. Installation on left side of generator Dirt separator In order to carry out continuous dirt separation in the system the 546 series DIRTCAL dirt separator is available as an accessory. Insulation The anti-condensation recirculation units are supplied with insulation shell to provide perfect thermal insulation.

Maintenance / Setting modification To remove the thermostatic sensor for maintenance or setting modification, proceed as follows, paying attention to the position of each component: ) Remove the insulation and the temperature gauges, shut off the three ball valves built into the unions of the unit by means of a flat screwdriver or a 4 mm hexagonal spanner and remove the unit body from the pipes, fully unscrewing the unions with a 5 mm spanner (fig. and ). b) Alternatively, using a 5 mm hexagonal spanner slightly loosen nuts B and C and fully unscrew nut A. Rotate the unit on the B-C axis while still mounted on the pipe. ) Using a 7 mm hexagonal spanner (fig. ), unscrew and extract the obturator locking nut, entering through the upper by-pass port on the unit. ) Extract the spring: fixed to it are the obturator and the thermostatic sensor (fig. 4). 4) Carry out maintenance or replace the thermostatic sensor with a suitable spare part. The sensor can be fully inserted into its seat with a slight interference. 5) Reassemble the obturator unit following the procedure in reverse order. B A C Application diagram 4 Solid fuel generator, system with inertial storage Solid fuel generator, connection to inertial storage in parallel Deaerator Dirt separator Pump Shut-off valve Expansion vessel Check valve Motorised mixing valve Pressure reducing valve Regulator Filling unit Backflow preventer Safety relief valve Dirt separator for vertical pipes Deaerator for vertical pipes Hydraulic separator Y-strainer

Solid fuel generator, direct supply to the system Solid fuel generator, direct connection to inertial storage SPECIFICATION SUMMARY 8 series Anti-condensation recirculation and distribution unit. Size DN 5. Connections (and /4 ) F (ISO 8-) with union. Brass body. Brass obturator locking nut. Brass unions and built-in ball. PSU obturator. Stainless steel spring. PPS clapet valve. EPDM seal elements. Medium water and glycol solutions. Maximum percentage of glycol 50%. Maximum working pressure 0 bar. Working temperature range 5 00 C. Temperature gauge scale 0 0 C. Built-in anti-condensation thermostatic valve: setting temperature 45 C, 55 C, 60 C, 70 C; setting accuracy ± C; by-pass complete closing temperature Tset + 0 C. Three-speed pump model RS 4- (or high-efficiency pump YONOS PARA 5/6); electric supply 0 V - 50 Hz; maximum ambient humidity 95%; maximum ambient temperature 80 C; protection class IP 44 (IPX4D). Complete with insulation. We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 9 n. 5 800 Fontaneto d Agogna (NO) Italy Tel. +9 0 849 Fax +9 0 867 info@caleffi.com www.caleffi.com Copyright 04 Caleffi