User guide RADIO DRIVER Wireless programmer 6051117 6051118 6051119 RADIO DRIVER 610-1 zone RADIO DRIVER 620-2 zones RADIO DRIVER 630-3 zones RADIO DRIVER DELTA DORE - Bonnemain - 35270 COMBOURG - FRANCE E-mail: deltadore@deltadore.com Device complying with the requirements of the directives: R&TTE 1999/5/CE *2701878_Rev.1* Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed by Delta Dore.
Warnings Carefully read these instructions prior to use. Do not attempt to repair the unit yourself; an after-sales service is available. Description Selector knob position Selector knob Off mode Absence mode Timer mode RADIO DRIVER Automatic mode Continuous mode Time setting Programming Modification buttons Contents Presentation.......................... 4 Automatic Mode....................... 6 Override............................. 8 Timer mode.......................... 9 Absence mode....................... 10 Continuous mode..................... 11 Shutdown mode...................... 12 Information button.................... 13 Time setting......................... 15 Programming......................... 16 1. Create your program..................... 16 2. Copy the program....................... 16 3. Confirm the program..................... 16 PLC RADIO GP8 OPTION.................. 19 Home automation functions.............. 20 Tempo tariff......................... 26 Replacing batteries.................... 27 Troubleshooting....................... 29
Presentation RADIO DRIVER allows Comfort or Economy programming of the heating for 1 zone (RADIO DRIVER 610), 2 zones (RADIO DRIVER 620) or 3 zones (RADIO DRIVER 630). It can be associated: - either with radio/pilot Wire receivers (example: TYXIA RF 660) to control Pilot Wire heating, - or with PLC/Pilot Wire receivers (example: TC51089) via the PLC RADIO GP8 option, - or with a wireless/infrared gateway (example: Radio D30) to control the split, - etc. Pilot Wire principle: Programmer Pilot Wire orders Heat emitters Independent from the power supply of the heat emitter, the Pilot Wire is used to send the Comfort, Economy, Frost Protection or Shutdown orders requested by the programmer. The required temperature is set on the thermostat of each heat emitter (convectors, panel heaters, underfloor heating or radiant ceiling heating, towel rail radiators, storage heaters, etc.). IMPORTANT: PThe heat emitter must be in automatic mode (PROG, AUTO, etc. depending on model) to receive orders from the programmer. Pilot Wire order (mode) Comfort Economy Setting on the heat emitter Comfort setting (thermostat knob) example: 19 C Economy setting (thermostat knob) example: 16 C or Comfort X C (depending on heat emitter model) Room temperature 19 C 16 C Receiver (e.g. Wireless/Pilot Wire) - 4 - Pilot Wire Absence Frost protection set to 7 C or 8 C (depending on model) Off Heating shutdown - 5-7 C or 8 C No Heating
Automatic mode Turn the knob to AUTO. RADIO DRIVER 610 follows the programming. Current day Room temperature Time Current mode Override Information button RADIO DRIVER 630 follows the programming in the 3 zones. Current day Room temperature Time Display in automatic mode Current mode in zones 1, 2 and 3 Override for zone 1 Override for zone 2 Override for zone 3 Information button Display in automatic mode RADIO DRIVER 620 follows the programming in both zones. Current day Room temperature Time Display in automatic mode Current mode in zones 1 and 2 Override for zone 1 Override for zone 2 Information button - 6 - - 7 -
Override In automatic mode, override is used to go from Comfort to Economy mode (or conversely) until the next program change. E.g. it is 15:30 and you would like to switch to Comfort mode before the set time (17:00). 00:00 6:00 8:00 15:30 17:00 23:00 00:00 Timer mode This mode is used to select a mode for a given time and for one zone only. Turn the knob to. Zone selection (the other zones are in AUTO mode) Confirm Current day programming on zone 1 Press the override button of zone 1. Choice of mode: Economy or Comfort Confirm Current override on zone 1. Adjustment of the duration from 15 minutes to 72 hours (in increments of 15 minutes) Confirmation and start of the countdown To cancel the current override, press the button once more. - 8 - At 17:00, the program will return to its usual program. To cancel the current timer mode, turn the knob. - 9 - Return to AUTO mode at the end of the countdown
Absence mode This mode lets you place your home under Frost Protection if you need to leave for several days. Turn the knob to. Adjustment of the number of days (1 to 365) E.g. for a departure on 1 March and a return on 10 March, program 9 days of absence. Automatic operation will resume on 10 March at midnight. Confirm and start the calendar countdown. Continuous mode This mode allows you to choose a continuous mode for each of the zone. Turn the knob to, then press the modification button of the relevant zone to select the Comfort or Economy mode. RADIO DRIVER 610 Current mode Room temperature Modification of the mode To cancel the current absence mode, turn the knob. - 10 - Return to AUTO mode at the end of the countdown Note: The water heater (DHW) is shutdown during the absence mode. If you want the water heater to be in automatic mode, refer to the installation guide or contact your installer or our customer service department. RADIO DRIVER 620 Room temperature - 11 - Current modes in zones 1 and 2 Modification of the mode in zone 1 Modification of the mode in zone 2
Continuous mode RADIO DRIVER 630 Room temperature To exit this mode, turn the knob. Off Mode Current modes in zones 1, 2 and 3 Modification of the mode in zone 1 Modification of the mode in zone 2 Modification of the mode in zone 3 Information button The display of all information related to home automation features (outside temperature, consumption indication, etc.) requires an activation phase from the RADIO DRIVER (see the home automation features section). During the AUTO, or, modes, press the i button repeatedly to find out: the outside temperature If, in your installation, you have the PLC RADIO GP8 option with an outdoor probe, total consumption of your installation If, in your installation, you have the Radio TYWATT option or a PLC RADIO GP8, This mode allows you to shut down your heating system (in this case, the water heater stays in automatic mode). Room temperature Consumption Reset Turn the knob to. Press successively To reset all meters, press and hold the init. button for 5 seconds. - 12 - - 13 -
Information button the electrical consumption in euros of the heating, water heater (DHW) and other electrical appliances (lights, household appliances, etc.). If, in your installation, you have the Radio TYWATT option or a PLC RADIO GP8 with additional CTs, Time setting Turn the knob to. The days flash. Press + or - to change the day, then press OK to confirm and continue on to the minute setting. Minutes Mise à zéro Mise à zéro Days (1 : Monday 7 : Sunday) Hours the program of the current day per zone. e.g. zone 1 To leave the time setting mode, turn the knob. NOTE: If the unit is configured for a daily program, the days setting is not offered. Comfort periods - 14 - - 15 -
Programming Turn the knob to PROG. The default program is a Comfort period from 6:00 to 23:00. 1. Creating your program Programming starts on day 1 at midnight. E.g. Comfort from 6:00 to 8:00 and from 17:00 to 23:00 00:00 6:00 8:00 17:00 23:00 00:00 Press the or buttons to create different Economy or Comfort periods. Day Zone to program 1 st time slot Comfort period adjustment Economy period adjustment Press and hold until you reach 06:00 Press and hold until you reach 23:00 2. Confirming and copying the program Press and hold the OK button for 3 seconds to confirm the program you created and copy it to the next day. Press and hold until you reach 08:00 Press and hold until you reach 00:00 3. Confirming the program Press the OK button to confirm and continue on to the next day to program it separately. - 16 - Press and hold until you reach 17:00-17 - Copy and confirm or simply confirm
Programming Checking your program Press the button repeatedly to check the accuracy of the Comfort and Economy periods you created. Time slot consulted Program Verification Profile of the different or periods Press the OK button to check the next day. Programming the other zones The programming for the other zones is available after pressing (OK) of the day 7 of the current zone. Exiting the programming mode Turn the knob to another mode. COMMENTS: Depending on the configuration made during installation, programming can be weekly or daily. Likewise, this programming may be done in increments of one hour, 30 minutes, or 15 minutes. To change these settings, refer to the installation guide, or contact our customer service department or your installer. - 18 - PLC RADIO GP8 option The PLC RADIO GP8 option is an energy manager for new or existing housing. Associated with the RADIO DRIVER, it lets you: - control the heating through receivers by using line carrier transmission (no modification of the electric installation), - provide load-shedding for up to 8 channels (single or three-phase), - display the total consumption (if associated with an electronic meter). Possibility of also measuring consumption per appliance (heating, DHW, other) by adding additional CTs (ref. 6330004), - associate home automation products (door/window magnetic contact, alarm control unit, telephone transmitter, etc.), - display the outside temperature (with wireless outdoor probe ref. 6300036). - 19 -
Amp. 90 CE 5 75 7,5 63 10 60 15 50 45 40 35 30 2520 OK RF GP8 RADIO CPL Home automation functions PLC RADIO GP8 can associate up to 7 home automation products (door/window magnetic contacts, alarm control unit, remote controls, etc.) for each of the heating zones + 7 products to act on all the heating zones (telephone transmitter, outdoor probe, etc.). Refer to the CP8 RADIO CPL installation guide to associate the different products. With a door/window magnetic contact When a door/window magnetic contact is associated with several heating zones, these zones are switched to frost protection mode when the contact is opened. E.g. door/window magnetic contact associated with zone 2 Zone 2 Activating the RADIO DRIVER PLC RADIO GP8 instantly accounts for all changes in the installation and transmits them to the receivers. To display these changes on the RADIO DRIVER (e.g. open entry), it must be activated by pressing a button. The update can take a few seconds. Activating the RADIO DRIVER Open Window Frost Protection E.g. Zone 2 in Frost Protection mode - 20 - RADIO DRIVER is on standby Press a button - 21 - RADIO DRIVER is activated and displays the status of the installation
Home automation functions With a TYXIA Transmitter When a TYXIA transmitter is associated with one or more heating zones. Pressing the button switches the associated zone(s) to Comfort mode until the next program change. Pressing the button switches the associated zone(s) to Economy mode until the next program change. E.g. remote control associated with zone 1 With a TYXAL alarm control unit When a TYXAL alarm control unit is associated with one or more heating zones. When you enable the alarm, the associated zone(s) automatically switch to Economy mode until the next program change. Conversely, when you disable the alarm, the associated zone(s) automatically switch to Comfort mode until the next program change. E.g. control unit associated with all the zones The command can be cancelled: - on the TYXIA transmitter, by pressing, - on the RADIO DRIVER, by pressing the zone 1 button or by turning the selector knob. This override can be cancelled on the RADIO DRIVER, by pressing the buttons of each zone or by turning the selector knob. - 22 - - 23 -
Home automation functions With a TYDOM telephone transmitter By calling the TYDOM telephone transmitter, let the synthetic voice guide you to determine or modify the status of the heating system or hot water tank (see the telephone transmitter guide). E.g. transmitter associated with all the zones With a TYDOM 200 remote control From the home domain, pressing the tactile button switches off all the zones. This off command is cancelled by pressing the button (return to automatic mode). Pressing the tactile or button switches the zone(s) associated with these buttons to Economy or Comfort mode until the next program change. E.g. and buttons of the TYDOM 200 associated with zone 3 1 2 3 4 5 6 7 8 9 0 # The command can be cancelled: - on the TYDOM 200 remote control, by pressing the tactile button, - on the RADIO DRIVER, by pressing the zone 3 button or by turning the selector knob. - 24 - - 25 -
Tempo tariff Only with an associated PLC RADIO GP8, Replacing batteries Battery level symbol the price programming is used to select a lower temperature (economy) in periods when electricity is most expensive (e.g. peak hours, red day). The electronic meter informs the PLC RADIO GP8 of the current price using the teleinfo line. Periods of tariff reduction can be programmed on your electronic meter (refer to the meter s instructions). Tariff reduction in progress The symbol flashes during a tariff reduction. The symbol flashes if you are in Médio (-1 C) or Modérato (-2 C) comfort mode. When the battery level symbol appears, you have around 1 month to change the batteries (two 1.5 V alkaline batteries, LR03 or AAA). The following precautions must be respected: - Ensure that the +/- polarities are correctly placed when the battery is fitted into the unit. - Do not dispose of used batteries in unauthorized places (you should respect the environment by taking the batteries to a suitable collection site). - Do not recharge the batteries. - You have approximately 30 seconds to change the batteries before the time is reset to zero (if this happens, reset the date and time). The other settings are unchanged. - 26 - - 27 -
Replacing batteries Troubleshooting 1 Separate the thermostat from its support The purpose of this section is to help you quickly solve the most common problems that you may encounter with your product during use. If you're unsure, or if the problem persists or isn't in this list, contact our customer service department. 2 Replace the batteries, making sure they are the right way round Nothing is displayed on the room unit screen. There is no power supply. Check the batteries or their polarity. The i symbol flashes. A fault has been detected in the system. Press the button to consult the fault or faults. 3 Position the thermostat 4 on its base Lock the thermostat The unit displays: def7. Communication fault with the electronic meter. Check the connection with the meter. The unit displays: def and a number other than def 7 There is a fault on the unit that requires it to be returned to our after-sales service. Contact our customer service department. The symbol flashes. You are in tariff reduction mode. Refer to the Tempo tariff section. - 28 - - 29 -
Troubleshooting When setting the time, there is no option to set the day. You are in daily programming mode. To switch to weekly programming, refer to the installation guide or contact your installer or our customer service department. The temperature displayed does not match the temperature measured in the room (thermometer). Refer to the installation guide or contact your installer or our customer service department. The consumption displayed by the unit does not correspond to the consumption shown on the bill sent by the electricity supplier. To check the cost of the kwh per tariff period, refer to the installation guide or contact your installer or our customer service department. Important: the consumption value that you can read on the unit is a non-contractual indication and cannot be substituted for the consumption value mentioned on your electricity supplier s bill. The unit is in time setting mode. There was a power supply disruption that lasted more than 30 seconds. Set the time. All other settings have remained unchanged. The heating elements are in Frost Protection mode You are in programming mode, the absence mode or time setting mode. Turn the knob to select another mode. You cannot change the programs. Program changes were locked during installation. - 30 - - 31 -