INSTALLATION ADJUSTMENT SERVICE

Similar documents
INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

TA-300, TA-300-LF, TA-350, TA-350-LF

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

MEGATRON MODEL 2, 3, 4, and 5

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

OUTLET LEONARDH THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

HOT INLET COLD INLET INSTALLATION

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

OUTLET LEONARD THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

MEGATRON MODEL TA, TA-LF

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation Manual. Models 99168, 99169, 99170

INSTALLATION, OPERATION AND MAINTENANCE

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Installation Instructions / Warranty. PuraVida 15775XX1

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

AeroVent 3X Product Manual

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

INSTALLATION INSTRUCTIONS WARRANTY

Installation S

Installation S

Installation S

INSTALLATION & TESTING MANUAL

INSTALLATION & TESTING MANUAL

Whole House Filter Model: WH-LD

Model 9201EFE Tempered Water Blending System

TUB AND SHOWER FAUCET

Thermostatic mixing valves with interchangeable cartridges

WATER TEMPERATURE CONTROL SYSTEMS

Installation Instructions PP-AS20 Anti-Scale System

CLASSIC HIGH LOW MANIFOLD SYSTEMS

ERGOMAX 7 INSTALLATION

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Installation S

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Installation Instructions

Installation Instructions / Warranty

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Model 9201EW Tempered Water Blending System

Model TWBS.SHE Tempered Water Blending System

Installation S

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Instruction Manual. Nacho Cheese Dispenser and Warmer

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Installation Instructions / Warranty. Massaud

Rada 25R Installation and Maintenance

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

Transcription:

Bulletin XL-670 July 201 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE MODEL XL-670-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ECO-MIX ASSE 1070 Certified This product is certified to meet Low Lead requirements of wetted surface area containing less than 0.2% lead by weight INSTALLATION 1. Valve should be installed at a location where it can easily be cleaned, adjusted or repaired. 2. The inlets are clearly marked on the valve body. Do not connect the hot water to cold inlet, and vice versa. Doing so will cause the valve to operate improperly. 3. An external shutoff should be installed downstream of the mixing valve assembly outlet as an extra safety precaution. 4. Use solder, or thread sealant sparingly. Supply pipes should be flushed before the valve is connected. Flush outlet pipe and valve as soon as it is connected. 12 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE CAUTION All thermostatic water-mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. Consult the flow capacity chart on page. Minimum flow must be no less than as shown. REMEMBER! THIS IS A CONTROL SYSTEM WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD MGR-1000). 1360 Elmwood Avenue, Cranston, RI 02910 USA Phone: 401.461.1200 Fax: 401.941.310 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com 1

METHOD #1 INSTALLATION REQUIRED METHODS OF PIPING XL SERIES Required when TEMPERED WATER is NOT CIRCULATED. Only the hot water supply to the mixing valve can be circulated with this piping arrangement. THERMOMETER T HOT WATER SUPPLY COLD WATER SUPPLY CIRCULATE HOT WATER FROM END OF LINE BACK TO TANK METHOD W Required when TEMPERED WATER IS CIRCULATED. FIXTURES, SUPPLIED BY TEMPERED WATER THERMOMETER T C CIRCULATOR A AQUASTAT HOT WATER SOURCE HEAT TRAP CHECK VALVE CHECK VALVE COLD SUPPLY CHECK VALVE OPERATION 1. Verify that the temperature of the hot water source is properly set and maintained. Shutoff and isolate the circulator pump. 2. Loosen LTR set screw located on temperature adjustment knob with Allen wrench on both valves. 3. To set the small valve, turn off large valve using the ball valve on the outlet. Turn on enough fixtures to flow approximately 1. GPM, turn knob clockwise until it stops (full cold) then counterclockwise until it stops (full hot), three times to exercise the thermostatic element. 4. Set mixing valve to the desired temperature, (See warning tag for temperature set point). Tighten LTR set screw.. To set the large valve, turn off small valve using the ball valve on the ¾ outlet. Turn on enough fixtures to flow approximately GPM, turn knob clockwise until it stops (full cold) then counterclockwise until it stops (full hot), three times to exercise the thermostatic element. 6. Set mixing valve to the desired temperature, (See warning tag for temperature set point). Tighten LTR set screw. 7. Open ball valve on the ¾ line on the outlet of the small valve and shut off all fixtures. Setup is complete. 8. Turn on circulator. With all fixtures still off, (no water flowing) observe the circulation temperature until it stabilizes. 2 9. If temperature rises, close balance valve until desired temperature is reached

INSTALLATION CONTINUED WARNING WARNING! This Thermostatic Mixing Valve has an Locking Temperature Regulator (LTR) which must be checked. If the temperature is too high, the installer MUST RESET this adjustment immediately. Always check the temperature of the mixed water after installation. Excessively hot water is DANGEROUS AND MAY CAUSE SCALDING! The LTR is factory set at approximately 120 F (49 C) with an incoming hot water supply temperature of 10 F (6 C) If the incoming hot water supply for your installation is higher than 10 F (6 C), the valve may deliver water in excess of 120 F (49) and the LTR MUST BE RESET BY THE INSALLER. SERVICE Leonard Type XL Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If the installation is accessible, servicing may be completed without disconnecting the valve. NOTE: Thermostatic Water Mixing Valves are REGULATING mechanisms, which must be regularly maintained to provide best performance. Frequency of cleaning depends on quality of local water conditions and usage. (See Maintenance Guide and Record MGR-1000). TROUBLESHOOTING INSTRUCTIONS ITEM: PROBLEM: RECOMMENDED REPAIR KITS (LARGE VALVE) RECOMMENDED REPAIR KITS (SMALL VALVE) PACKINGS & GASKETS 1. Leak at stem. 2. Leak between valve cover and base. KIT 1/XL82 KIT 1/WX SHUTTLE ASSEMBLY 3. Valve delivers either all hot or all cold water, or will not mix consistently. KIT R/XL82 KIT R/269 CHECKSTOPS 4. Hot water bypass into cold line. KIT 2/690 KIT 4/220. Supplies cannot be shut off completely. 6. Leak at checkstop bonnet. REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000). 3

LARGE VALVE PARTS LIST 9 7 10 NOTE: DO NOT REMOVE 8 SNAP RING ON STEM KIT # TYPE KIT INCLUDES KIT R/XL82 REPAIR KIT 1-7 KIT 1/XL82 O-RING 2,3,6,7 KIT 2/690 CHECK 11-16 18 6 1 16 17 4 KIT R/XL82 12 11 13 14 3 1 2 19 20 21 ITEM # DESCRIPTION QTY. PART # / KIT # XL-82 1 SPRING, RETURN 1 KIT R/XL82 2 O'RING, LOWER SHUTTLE 1 KIT 1/XL82, KIT R/XL82 3 O'RING, UPPER SHUTTLE 1 KIT 1/XL82, KIT R/XL82 4 SHUTTLE ASSEMBLY 1 KIT R/XL82 RETAINING RING, COVER 1 7611, KIT R/XL82 6 O'RING, COVER 1 KIT 1/XL82, KIT R/XL82 7 O'RING, STEM 1 KIT 1/XL82, KIT R/XL82 8 STEM ASSEMBLY (DO NOT REMOVE SNAP RING) 1 761900 9 COVER 1 7604 10 KNOB ASSEMBLY 1 764000 11 PACKING, STRAINER CAP 2 014, KIT 2/690 12 SCREEN 2 013, KIT 2/690 13 LOWER STEM & PACKING 2 03, KIT 2/690 14 SPRING,CHECK 2 KIT 2/690 1 PACKING, BONNET 2 0, KIT 2/690 16 O'RING, UPPER STEM 2 MU-A, KIT 2/690 17 STEM, UPPER CHECK 2 MU-4A 18 BONNET 2 2 19 STRAINER CAP 2 6 20 SWIVEL 2 04/0 21 SWIVEL NUT 2 09/0 4

SMALL VALVE PARTS LIST SCREW RETAINING CLIP KNOB STEM ASSEMBLY O'RING COVER O'RING STEM ASSEMBLY SHUTTLE ASSEMBLY DO NOT REMOVE SNAP RING ON STEM - INJURY MAY OCCUR CHECK DIAL PLATE RETURN SPRING KNOB SET SCREW COVER SHUTTLE O'RING MODEL 269-LF 1/WX Gasket Kit Shuttle o-ring Stem assembly o-ring Cover o-ring R/269 Rebuild Kit Return spring Shuttle assembly Shuttle o-ring Stem assembly o-ring Cover o-ring 4/220 Check valve Kit 2 Check valves 2 Check Clips DISMANTLING & CLEANING 1. Shut off hot and cold water to the valve as well as the valve outlet port. 2. Loosen lock screw on side of knob with /64 allen wrench. 3. Remove the knob screw on top of knob. 4. Remove temperature adjustment knob.. Remove valve cover, which includes the stem assembly. 6. The shuttle assembly can now be removed, cleaned and inspected. Be sure to check the condition of the shuttle o-ring and replace if necessary. 7. Lubricate the shuttle o-ring before installing the shuttle assembly. 8. Install the cover assembly including o-ring back onto valve and tighten. 9. Replace knob and knob screw. 10. Valve temperature must be reset after any repairs or cleaning!! See Page 2. Temperature Adjustment TROUBLESHOOTING 1. Leaking water under knob, order gasket kit, replace stem assembly o-ring. Remove knob screw and knob, remove retaining clip, thread out the stem assembly and replace o-ring. Lubricate o-ring, thread stem into cover, replace retaining ring, knob and screw. Valve temperature must be reset after any repairs or cleaning!! See page 2. 2. Leaking water between cover and body, order gasket kit, replace cover o-ring. Remove knob screw and knob and remove valve cover and replace o-ring. Replace valve cover, knob and knob screw. Valve temperature must be reset after any repairs or cleaning!! See page 2. 3. Hot water bypass into cold line, order checkstop kit and replace checks within inlets of valve. 4. Valve not controlling temperature even after cleaning, order complete rebuild kit. Remove knob screw and knob and remove valve cover. Replace shuttle assembly and return spring being sure to lubricate shuttle o-ring. Replace valve cover, knob and knob screw. Valve temperature must be reset after any repairs or cleaning!! See page 2.

FLOW CAPACITIES VALVE XL-670-LF MIN. FLOW 2. 9. 0.3 19 10 0.7 10 38 1 1 20 76 PRESSURE DROP 20 2 30 1.4 1.7 2.1 3 39 41 132 148 1 3 40 2.4 2.8 48 182 208 4 3.1 9 223 0 3.4 62 23 60 3.8 64 242 4.1 6 246 PSI BAR GPM l/min NOTE: Flowrates will vary depending on existing field conditions. Leonard Valve Company always recommends using CASPAK sizing software for proper valve sizing and model number applications. FLOW RATE GPM (l/min) 6 (246) 60 (227) (208) 0 (189) 4 (170) 40 (11) 3 (132) 30 (114) 2 (9) 20 (76) 1 (7) 10 (38) (19) 10 1 20 2 30 3 40 4 0 (0.3) (0.7) (1.0) (1.4) (1.7) (2.1) (2.4) (2.8) (3.1) (3.4) PRESSURE DROP PSI(BAR) LIMITED WARRANTY (3.8) 60 (4.1) Leonard Valve Company warrants the original purchaser that products manufactured by them (not by others) will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with Leonard Valve Company's instructions, for a period of one year from date of shipment. During this period the Leonard Valve Company will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship. There are no warranties, express or implied, which extend beyond the description contained herein. There are no implied warranties of merchantability or of fitness for a particular purpose. In no event will Leonard be liable for labor or incidental or consequential damages. Any alteration or improper installation or use of the product will void this limited warranty. 2013 Leonard Valve Company Printed in USA 1360 Elmwood Avenue, Cranston, RI 02910 USA Phone: 401.461.1200 Fax: 401.941.310 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com 6