BS-100 DYFI. Installation handbook. Protecting environment, life and property... P-BS100/DCE

Similar documents
Installation Handbook. Interactive Fire Alarm System Release 3. Operator Panel, BS-330. Protecting life, environment and property...

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

General Routing Interface

FEC400 Series. Installation Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Installation, Operating and Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Application, Installation, Operation & Maintenance Manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Intelligent Security & Fire Ltd

INPUT / OUTPUT MINI MODULES

Installation and user manual for the BiWire / Conventional Repeater Panel

An introduction to... Sigma

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Intelligent Security & Fire Ltd

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

System 800 Addressable Fire Detection & Alarm System

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Planning Instructions MEW01090 Revision 4

Product Data Sheet. Remote Terminals. Features:

1X-F Series Installation Manual

System 57. An advanced World of intelligent gas detection system management

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

System 57. An advanced world of intelligent gas detection system management

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Fire alarm system EBL512 G3

FX FIRE DETECTION SYSTEM

ACCURATE ELECTRONICS INC

SCR100 User Manual. Version:1.1 Date:Dec 2009

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

Fire Control Panel FS4000

MODEL 5100 VOTING LOGIC MODULE

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

SOUNDER CONTROL MODULE SCM-AS4

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Excel-EN Conventional Fire Control Panel

Fire Alarm Control Panel. System Maintenance and Log Book

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

MODEL B2 INSTALLATION MANUAL

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

ANALOX 3000 Carbon Monoxide Monitor

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

5000 INSTALLATION GUIDE

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Shortform Configuration Guide

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

M2500 Engine Controller Installation Manual

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Precept Marine Control Panel Application Guide

FEC403EN Installation Manual

Flair 500 Series Annunciators

Control Panel Engineering and Commissioning Instructions

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

20 Light Remote Annunciator

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

MINERVA MX. 800 Series Ancillary Equipment

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

M1000 Alarm Annunciator

The EN54 Part 2 & 4 Fire System

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

4 & 8-POINT ANNUNCIATORS Instruction Manual

FireNET Plus Wiring Instructions

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

QA16 Addressable System

RELEASE DEVICE CONTROLS

Fire Control Panel FS4000

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

Interface and EOL Modules 8

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Sita200plus. 200detectors. Single loop analogue addressable System

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

Intelligent Security & Fire Ltd

Notification Appliance Circuit Module

ZSC100 Gas Detection and Alarm System Controller

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Fire control panel detect 3004 plus and accessories

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Conventional Leaflets

Transcription:

BS-100 DYFI Protecting environment, life and property... P-BS100/DCE

P-BS100/DCE/Doc/961023 2 Autronica Fire and Security AS

Contents Please observe! This handbook contains installation instructions for fire alarm system BS-100 DYFI ready designed and assembled from the factory. If the system is to be expanded on site, please see separate booklets concerning internal mounting, internal connections, switch settings, commisioning a.s.o. Page 1. Mounting...5 1.1 Location...5 1.2 Wall (bulkhead) mounting...5 1.2.1 Release the electronic cassette...5 1.2.2 Mounting height...6 1.2.3 Mounting holes...6 1.2.4 Fasten screws...7 1.2.5 Cable inlets...7 1.2.6 Cable outlets...8 1.2.7 Cable length...8 1.3 Flush mounting...8 1.3.1 Cut-out...8 1.3.2 Flush monting in a wall...9 1.3.3 Flush mounting of cabinet in a wall...9 1.3.4 Cable insertion...10 1.4 Cut-out and flush mounting in a (control) desk...10 1.5 Mounting in a 19 rack...11 2. Connections...12 2.1 Connection on List 1 and List 2...13 2.2 Connection on List 3...14 2.3 Connection on List 10 and List 20...15 3. Expansion modules...16 3.1 External connections to optional detector loop module BSD-100...16 3.2 External connections to optional alarm output module BSB-100...17 3.3 External connections to optional control output module BSJ-100 / BSJ-101...18 3.4 External connections to optional data output module BSL-100...19 3.4.1 Connection of peripheral data equipment to the BSL-100 module...19 3.4.2 Table of connections between data output module BSL-100 and Autronica manufactured peripheral equipment...21 P-BS100/DCE/Doc/961023 3 Autronica Fire and Security AS

P-BS100/DCE/Doc/961023 4 Autronica Fire and Security AS

Mounting 1. Mounting Location 1.1 Location The control panel is to be located in, or near by, the entrance according to local regulations and in consultation with the fire brigade (fire fighters). Wall / bulkhead 1.2 Wall (bulkhead) mounting The BS-100 DYFI panel is delivered as standard in two types of steel plated cabinets: Cabinet UEA-22/1 and UEA-23/1 for panels with up to two detector loops, (max. 198 addresses). Cabinet UEA-22/2 and UEA-23/2 for panels with more than two detector loops, (more than 198 addresses). The difference between UEA-22 and UEA-23 is the depth. 1.2.1 Release the electronic cassette Release the electronic cassette by unscrewing the four screws on the front frame. See fig. no. 1. The cassette including the front door can now be lifted out of the cabinet. If the cassette is fixed to the cabinet, bend it out carefully by using a screw driver. Fig. no. 1: Front frame screws Front screws FIRE NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN DYFI SOUNDER SILENCE MORE ALARMS RESET DEVICE(S) STILL IN ALARM COND. PREWARNING FAULT FUNCT. DISABL. MAINS BS 100 Autronica Front screws P-BS100/DCE/Doc/961023 5 Autronica Fire and Security AS

Mounting height 1.2.2 Mounting height The recommended mounting height of the panel top is 180 cm above the floor due to optimal readability of the texts in the display.! In order to open the front door completely, there must be a free space of min. 450 mm on the left hand side of the panel. 1.2.3 Mounting holes The cabinets have four (4) mounting holes located at the rear wall. The two upper holes are of the key-hole type. See fig. no. 2a, (for cabinet UEA-22/1 and UEA-23/1) and fig. no. 2b (for cabinet UEA- 22/2 and UEA-23/2). Mark and drill holes for fixing screws and plugs (max. 6 mm screws). See fig. no. 2a and 2b. Partly fasten the two upper screws. 446 310 246 387 Ø6,8 Cabinet UEA-22/1 and UEA-23/1 141 163 --- UEA-23/1 Fig. no. 2 a: Cabinet dimensions FLUSH 164 MOUNTING FRAME 476 mm (CABINET) 446 mm 142 22 CUT OUT MOUNTING FRAME 651 C A B I N E T 6 2 1 387 mm 543 C U T O U T 627 Cabinet UEA-22/2 and UEA-23/2 Ø 6.8 mm 452 CUT OUT Fig. no. 2b: 163 --- UEA-23/2 Cabinet dimensions P-BS100/DCE/Doc/961023 6 Autronica Fire and Security AS

Please observe: The three small holes at the front of the four cabinet sides are intended for mounting a cover frame used when the cabinet is to be flush-mounted. See section 1.3.2. 1.2.4 Fasten screws Hang the cabinet to the two upper screws and check that the cabinet is angularilly mounted. Fasten the two lower screws, and tighten all four screws. 1.2.5 Cable inlets! Feed all cables into the cabinet from the top and / or bottom through the suitable cable inlets. See fig. no. 3. In the fixed mains wiring to the panel a two-pole disconnect device shall be provided to disconnect the equipment from the supply for servicing. When feeding cables into the cabinet from the bottom side, the following precautions must be taken. a) The mains cable must be fed through the cable inlet at the very left hand side. b) All other cables should be fed through the succesive inlets. Let the thinnest cables be fed through the rightmost inlets. c) If cables are fed into the cabinet from the top, all cables must be put closely to the cabinet rear wall, guided to the bottom and bent out to the front. d) All cables fed into the cabinet must have a minimum length of 1 m inside the cabinet. 26 mm Ø 17 mm Cable inlet holes 161 Ø 33 mm Ø 19 mm 20 mm 446 mm Fig. no. 3: Cable inlet holes. P-BS100/DCE/Doc/961023 7 Autronica Fire and Security AS

1.2.6 Cable outlets All cables are guided through the open space at the lower left hand side of the electronic cassette. Then the cassette is mounted and the fixing screws are fastened. See fig. no. 1. Cables fed into the cabinet from the top are now partly hidden behind the cassette. 1.2.7 Cable length The cables length are adjusted according to the appropriate terminals, then stripped and connected. See section 2.1, 2.2, 2.3, 2.4 and 2.5. Flush mounting 1.3 Flush mounting Cut-out 1.3.1 Cut-out Cut-out for mounting of the cabinet in a wall. See fig. no. 4. Before the cabinet is mounted, remove the elctronic cassette as described in section 1.2.1. The dimensions given include space for the cover frame. See fig. no. 5. Cables are fed into the cabinet from the top and / or from the bottom. Cabinet UEA-22/1 anduea-23/1 Cut.out in wall 316 452 142 164--- UEA-23/2 Cabinet UEA-22/2 and UEA-23/2 627 452 mm 142 164 --- UEA-23/2 Cut.out in wall Fig. no. 4 Cut-out and cable inlets, both types of cabinet P-BS100/DCE/Doc/961023 8 Autronica Fire and Security AS

In a wall 1.3.2 Flush monting in a wall Flush mounting of cabinet in a wall. If a flush mounting is planned before construction of the wall, the cabinet can be used as casting form for the wall. The cover frame must be mounted and the electronic cassette must be removed. The cover frame is fixed by means of POP -riveting.! Please observe that the cabinet must be supported before concreting to avoid deformation. The cable tubes needed are fed into the cabinet by means of a socket joint. 1.3.3 Flush mounting of cabinet in a wall Mounting of cabinet in a wall. See fig. no. 5. Cover frame for flush mounting of cabinet UEA-22/1 and UEA-23/1 = UE-818/L. Cover frame for flush mounting of cabinet UEA-22/2 anduea-23/2 = UE-818/H. Cabinet UEA-22/1 and UEA-23/1 475,5 340,5 246 387 Ø 6,8 Screws Cabinet UEA-22/2 and UEA-23/2 Cable tubes 475,5 387 543 651 142 163 --- UEA-23/2 Ø 6,8 Fig. no. 5: Dimensions, cabinets mounted in a wall P-BS100/DCE/Doc/961023 9 Autronica Fire and Security AS

1.3.4 Cable insertion See section 1.2.5, 1.2.6 and 1.2.7. Control desk 1.4 Cut-out and flush mounting in a (control) desk When the control panel is mounted in a control desk or similar, the cabinet is not needed. The cut-out dimensions therefore are only for the electronic cassette. See fig. no. 6. Ø9 Fixing screws M4x10, DIN965, UTN 007/4F Fixing hole: 4xM4 274 427 288 7 26 20 335 20 Neoprene gaskets, 2 pcs. 10 x 4 x 270 mm 20 Fig. no. 6: Cut-out for mounting in a control desk. P-BS100/DCE/Doc/961023 10 Autronica Fire and Security AS

19 rack 1.5 Mounting in a 19 rack When the control panel is to be mounted in a control desk, two (2) mounting brackets type UE-814 must be used. The control panel is mounted without the cabinet. The mounting brackets are fixed to the electronic cassette with two screws M5 mm in each bracket as shown in fig. no. 7. The figure shows the cut-out dimensions and the location of the fixing holes. When all cables are fed into the rack, the control panel with the mounting brackets is put into the rack and fastened. 483 ( 19 ) 6,8x10,3 113 FIRE NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN DYFI SOUNDER SILENCE MORE ALARMS RESET 235 270 DEVICE(S) STILL IN ALARM COND. PREWARNING FAULT FUNCT. DISABL. MAINS BS 100 Autronica Mounting bracket UE-814 465 Mounting bracket UE-814 20 Fixing holes ø5 mm Fig. no. 7: Dimensions (incl. mounting bracket) for mounting in a 19 rack. P-BS100/DCE/Doc/961023 11 Autronica Fire and Security AS

Connections! 2. Connections Remove fuses F1 and F2 before any connection work! Location of fuses and terminal blocks (list 1, list 2, list 3, list 10 and list 20) are clearly indicated on the main board cover. See fig. no. 8. Fuse F1 Fuse F2 Fuse F3 Fuse Fuse Fuse Fuse Main board cover with text information List 10 and list 20 List 3 Front panel List 1 and list 2 Plastic door Fig. no. 8: Location of terminals and fuses Fuses Fuses Size Type Protecting F1 1,4A Slow Mains * F2 6,3A Fast Battery F3 1A Slow External 24V DC ** F31 1A Fast Alarm output 1 ** F32 1A Fast Alarm output 2 ** F33 1A Fast Alarm output 3 ** F34 1A Fast Alarm output 4 All fuses are located on the main board just above the terminals. * For Chinese Market - 2,5A ** For Chinese Market - 0,250A P-BS100/DCE/Doc/961023 12 Autronica Fire and Security AS

List 1 and 2 2.1 Connection on List 1 and List 2 Mains, chassis (earth), battery, test output (internal function) and power output 24 V DC. Function External connection List 1 Chassis (earth) 01 V Internal function 230 V AC, Mains O SP 2 230 V AC, Mains L 3 List 2 Accumulator BATT + 4 (battery) BATT - 5 Internal function 24 V DC output Max. load 1 A Ext. 24 V DC Test 6 + 0 7 8 Ext. 24 V and DHM+ list 3 have common fuse F3 (1A) Fig. no. 9: Connections on List 1 and List 2! The fire alarm control panel shall not be connected to the mains and battery, and the removed fuses shall not be installed until commisioning of the system. P-BS100/DCE/Doc/961023 13 Autronica Fire and Security AS

List 3 2.2 Connection on List 3 Various inputs / outputs; group disablement, external alarms, relay contacts, general alarm, electromatic door holders and quiet (delayed) alarm input. Function Special domestic (national) functions External connection +24V Max.100mA 0 V SP Alarm organization D / N Monitoring of external equipment E General alarm GA Group disabling 1 Group disabling 2 Group disabling 3 Electromagnetic door holder(s) Changes at fire alarm condition Changes at fire alarm condition List 3 9 10 11 12 13 Internal function Common 0V. Output (open collector) Delayed alarm signal Fault signal. When used, cut strap W13 Steady signal to all Alarm outputs 1 14 Disable groups of GRU 2 detectors. Freely 15 programmeable. 3 16 Max. 1A at 24VDC + Ext. 24V (list 2) Coil 17 DHM and DMH+ have - common fuse, F3 18 (location: + leader) Max. 1A at 24VDC AUX Potential 19 free changeover 20 contact Max. 1A at 24VDC BMA 21 Potential free 22 changeover 23 contact 24 Fig. no. 10: Connections on list 3 P-BS100/DCE/Doc/961023 14 Autronica Fire and Security AS

List 10 and 20 2.3 Connection on List 10 and List 20 Alarm outputs and fire detector loops. Function External connection List 10 Internal function Alarm output 1 for bells / sounders +24V 0V 25 26 AK-1 Alarm output 2 for bells / sounders +24V 0V 27 28 AK-2 Alarm output 3 for bells / sounders +24V 0V 29 30 AK-3 Alarm output 3 for bells / sounders +24V 0V 31 32 AK-4 Detector loop connection (The example shows a single loop system.) Min. voltage at the end of the loop: > 12V. 3 1 4 2 3 1 List 20 33 34 35 36 A 0 A (0) B + B (+) Detector loop connection (The example shows a double loop system.). Min. voltage at the end of the loop: > 12V. 4 2 Rmax < 15Ω 3 4 1 2 Rmax < 15Ω 3 1 37 38 39 40 A 0 A (0) B + B (+) Fig. no. 11: Connections on List 10 and 20. P-BS100/DCE/Doc/961023 15 Autronica Fire and Security AS

Expansion 3. Expansion modules Detector loop module BSD-100 3.1 External connections to optional detector loop module BSD-100 The module features two optional detector loops. Each loop has a capacity of max. 99 addresses. A A`B B`T A A`B B`T 1 2 3 4 5... 6 7 8 9 10 Chassis (earth) LED +24 V DC Max.100mA (optional) LED +24 V DC (optional) Example of a single loop system 1 2 1 Min. voltage to the last detector is 12V. 3 4 3 Example of a double loop system 1 2 3 4 1 2 3 4 Maximum loop resistant is 30Ω Fig. no. 12: External connections on BSD-100 The figure shows two different types of loop connections: The double loop system and the single loop system. The two types of loop systems can both be connected to eighter of the two terminals. The T -output (open collector control output) terminals (no. 5 and 10) are triggered by a fire alarm on any address in the loop. Steady light in the LED until the BS-100 panel is reset. P-BS100/DCE/Doc/961023 16 Autronica Fire and Security AS

Alarm output module BSB-100 3.2 External connections to optional alarm output module BSB-100 The module features 4 optional outputs (bells, buzzers, sounders, alarm lights). All alarm outputs (AK-1 to AK-4) are freely programmeable. 24 V DC power supply to the next BSB-100 unit Connections ready made at the factory. + 0 0 V + 24 V DC 0 0 + + 14... 10 F1 1A F2 1A F3 1A AK1 AK2 AK3 AK4 F4 1A 1 2 3 4 5 6 7 8 + + + + R A 820 Ohm/0,3W resistor must be connected when the output is not in use Alarm light R Electronic buzzer. When the internal resistance exceeds 820 Ohm, a parallel resistor of 820 Ohm must be connected in parallel to avoid constant breakage signal. - Alarm bells. When using non-polarized alarm bells, only the cables up to the first bell are monitored. R 820 Ohm + When an alarm circuit with polarized bells are used, a 820 Ohm resitor must be connected in parallel to the last bell on the circuit as indicated in the fig. Fig. no. 13: Example of external connections on BSB-100 All alarm outputs (AK1 to AK4) are relay outputs: Max. load 1 A at 24 V DC. (For Chinese marked 0,25A). P-BS100/DCE/Doc/961023 17 Autronica Fire and Security AS

Control output module BSJ-100 3.3 External connections to optional control output module BSJ-100 / BSJ-101 The module features 16 control outputs. All outputs are freely programmable. 17 18 19 Lamp test (operates all outputs on the same module) 0 V from the BS-100 DYFI panel Connections ready made at the factory 1 2 3 4 5 6 7 8 9 10 12 14 16 + At inductive load, a protecting diode must be used 2,4 W LED with serial resistor R=1,5 kohm + 24 V DC from BS-100 DYFI panel (list 2, pt. 7 and 8, be aware of the total load) Fig. no. 14: Example of external connections on BSJ-100/BSJ-101. All outputs: Max. load 100 ma, open collector (NPN).! The control output modules BSJ-100 are used for up to 128 outputs. If more outputs are needed, the control output modules BSJ-101 must be used. (BSJ-101 from output 129-240) P-BS100/DCE/Doc/961023 18 Autronica Fire and Security AS

Control output module BSL-100 3.4 External connections to optional data output module BSL-100 The module features both 20 ma current loop and RS232C data outputs. 20 ma Currrent loop RS232C 0 V CLT- CLT+ 0 V CLR- CLR+ RTS TXD DTR RXD 1 6 7 10 1 H1 H2 X12 1 S1 8 1 10 S2 15 7 Fig. no. 15: External connections to data output module BSL-100 The mostly used connection configurations for BSL-100 and the corresponding peripheral equipment are shown below:! Config.: A 3.4.1 Connection of peripheral data equipment to the BSL-100 module Data output: 20 ma current loop. Max. cable capacitance: 220 nf (at 1200 baud) Max. cable resistance : 340 Ω. Configuration A (on BSL-100): Active transmitter - Active receiver Data output module BSL-100: Active transmitter, active receiver 0 V 1 CLT -2 CLT +3 0 V 4 CLR -5 CLR +6 RTS 7 TXD 8 DTR 9 RXD 10 Fig. no. 16: Peripheral data equipment: (Passive transmitter, passive receiver) CLR - CLR + CLT - CLT + Active transmitter - active receiver P-BS100/DCE/Doc/961023 19 Autronica Fire and Security AS

Config.: B Configuration B (on BSL-100): Active transmitter - Passive receiver Data output module BSL-100: Active transmitter, passive receiver Peripheral data equipment: (Active transmitter, passive receiver) 0 V 1 CLT -2 CLT +3 0 V 4 CLR -5 CLR +6 RTS 7 TXD 8 DTR 9 RXD 10 CLR - CLR + 0 V CLT - Fig. no. 17: Active transmitter - passive receiver Config.: C Configuration C (on BSL-100): Passive transmitter - Passive receiver Data output module BSL-100: Passive transmitter, passive receiver Peripheral data equipment: (Active transmitter, active receiver) 0 V 1 CLT -2 CLT +3 0 V 4 CLR -5 CLR +6 RTS 7 TXD 8 DTR 9 RXD 10 0 V CLR - 0 V CLT - Fig. no. 18: Passive transmitter - passive receiver P-BS100/DCE/Doc/961023 20 Autronica Fire and Security AS

Autronica peripheral equipment connected to BSL-100 3.4.2 Table of connections between data output module BSL-100 and Autronica manufactured peripheral equipment Autronica Connection between Max. loop peripheral equipment BSL-100 and resistance type: peripheral equipment: (Ohm): 1 pc. 690 BU-100 Configuration type A 5 pcs. 450 Fireman s panel 10 pcs. 150 1 pc. 690 BU-101 (marine vers.) Configuration type A 5 pcs. 450 Fireman s panel 10 pcs. 150 1 pc. 690 BU-70 Configuration type A 5 pcs. 450 Indication panel 10 pcs. 150 KDL-26B Configuration 1 pc. 690 Communication line type B splitter 1 pc. 690 EA-2A Configuration type B 5 pcs. 450 Micro computer 10 pcs. 150 1 pc. 690 EA-3A Configuration type B 5 pcs. 450 Micro computer 10 pcs. 150 AutroMaster 300 Connected via driver Alarm presentation unit RTZ-20 ------------- system (contact Autronica) AutroMaster 5000 Connected via driver Alarm presentation unit RTZ-20 ------------- system (contact Autronica) Please be aware of the information given in section 3.4.1 conserning max. cable capacitance. For configuration of other types of peripheral equipment, please contact Autronica. Configuration types : See section 3.4.1. P-BS100/DCE/Doc/961023 21 Autronica Fire and Security AS

Autronica Fire and Security AS is an international company, based in Trondheim, Norway and has a world-wide sales and service network. For more than 40 years Autronica s monitoring systems have been saving lives and preventing catastrophes on land and at sea. Autronica Fire and Security s most important business area is fire detection & security. Autronica Fire and Security stands for preservation of environment, life and property. Quality Assurance Stringent control throughout Autronica Fire and Security assures the excellence of our products and services. Our quality system conforms to the Quality System Standard NS-EN ISO 9001, and is valid for the following product and service ranges: marketing, sales, design, development, manufacturing, installation and servicing of: fire alarm and security systems petrochemical, oil and gas instrumentation systems for monitoring and control In the interest of product improvement, Autronica Fire and Security reserves the right to alter specifications according to current rules and regulations. Autronica Fire and Security AS Fire and Security, Trondheim, Norway. Phone: + 47 73 58 25 00, fax: + 47 73 58 25 01. Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99. Autronica Industrial Ltd., Watford, United Kingdom. Phone: 1923 23 37 68, fax: 1923 22 55 77. P-BS100/FE - Rev.F / Doc/ 980114 Autronica Fire and Security AS