DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Similar documents
DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued

Toroidal Conductivity Transmitters Series APT4000 Specifications

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Hydrazine Analyzer Series 2171 Specifications

MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Dissolved Oxygen Product Name Part No.

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

Controllers, Indicators & Set Point Programmers

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Durafet Non-Glass ph Electrodes Specifications

Intrinsically Safe Transmitters, Option Code 2n

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Nov 08 PRODUCT SPECIFICATION SHEET

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Conductivity Product Name Part No.

DirectLine DL424/425 Sensor Module for DL 5000 Dissolved Oxygen Probes User Manual

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

UDA2182 Universal Dual Analyzer

UDC100 Universal Digital Controller Specifications

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

UDA2182 Universal Dual Analyzer

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Gas and On-Line Analyzers

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

UDC 700 Universal Digital Controllers and Indicator Specifications

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

NT DUAL CHANNEL DISPLAY. User Guide

Rosemount 4500 Hygienic Pressure Transmitter. Start

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

MICRO SWITCH GLL Series

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Sensors and Switches in Commercial Traction Elevators

HIH-4010/4020/4021 Series Humidity Sensors

HIH-4030/31 Series Humidity Sensors

DirectLine DL421 Sensor Module for ph Measurements User Manual

UDA2182 Universal Dual Analyzer Specifications

APT2000 Series 2-Wire Contacting Conductivity Transmitters User Manual MU1I-6246 Revision 1 01/00

SECTION Fluorescent Dissolved Oxygen Measuring System

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

High Pressure Conductivity Monitor

Airflow Sensors Line Guide

Isolated Thermocouple Module

EXA Conductivity & Resistivity Analysers

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Force Sensors Line Guide

Wireless Panel-Mount Monitor


DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Interactive Catalog Replaces Catalog Pages

Model 144H. Product Data Sheet , Rev DB February Content

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

Airflow Sensors Line Guide

Potential Applications

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

ENDURANCE Conductivity Sensors

Inductive Conductivity

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Level Measurement Continuous level measurement - Ultrasonic transmitters

Model Q45P/R. ph/orp Monitor...

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

SECTION Free/Available Chlorine Analysis System

Installation Instructions for the 600 Series Optical Encoders

Interactive Catalog Replaces Catalog Pages

HIH-4602-L Series Humidity Sensors

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Continuous level measurement Ultrasonic transmitters

MICRO SWITCH BX/BX2 Series

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Engineering Guideline. pac- Carriers Type Universal

HIH-5030/5031 Series Low Voltage Humidity Sensors

Model Q45P/R. ph/orp Monitor...

WH EN IGH T T C LO SED

DirectLine DL424/425 Sensor Module for DL 5000 Dissolved Oxygen Probes User Manual

Installation Instructions for the

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Transcription:

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as part of a new generation of analytical measurement. The DirectLine sensor s unique architecture combines the latest in microelectronics technology with the proven performance of Honeywell conductivity cell, to provide unequaled savings during installation, start-up, operation, and maintenance. For special mounting applications, the remote mounting option connects the electronics module to the conductivity cell via a cable. The electronics module is then mounted on a 2-inch pipe, wall, or DIN rail. The DirectLine electronics module can mount integrally on the conductivity cell and provide a 4-20 ma dc output proportional to conductivity. The output of the DirectLine sensor connects directly to any host monitor or control device that accepts standard 4-20 ma inputs and provides external loop power including: Honeywell UDC3300 1/4-DIN Controller UMC800 Controller PLCs with analog inputs DCS systems A host of recorder/controller products For conductivity cell submersion or special mounting applications, the electronics module is also available in a remote-mounting configuration. Description The Honeywell DirectLine architecture consists of an electronics module integral to the conductivity cell. This design eliminates the need and added cost of a separate analyzer or transmitter. The electronics module is sealed in a plastic weatherproof, corrosion-resistant housing and is connected to the conductivity cell on one side and a 4 20 ma output cable on the other via waterproof connectors. This housing design allows this system to be used in harsh environments where moisture and dust is a problem. Figure 1 DirectLine DL423 Sensor Features Direct 4-20 ma output eliminates need for dedicated analyzers or transmitters, simplifying installation, startup, operation, and maintenance tasks. Installation costs are also reduced because standard cable can be used for additional cable distances. Automatic upload of cell constant and cell calibration factor from cell EEPROM reduces set-up time. Integral electronics with local HMI simplifies installation and shortens calibration times. Modular plug-in construction simplifies electrode replacements.

DL423 DirectLine Sensor Module for Conductivity Measurement 2 Features Continued Local display and keypad facilitates quick set-up, calibration, and operational activities. ½ NPT conduit connection provides increased protection and noise immunity of output cable. Plug-in modular design allows sensor to be safely removed and replaced without cycling power on the electronics module. Remote Mounting Applications For special mounting applications, a remote electronics module option is available. The remote electronics module is mounted on a 2-inch pipe, wall, or DIN rail. The remote sensor cable directly connects the electronics module to the sensor with a submersible connector. The remote sensor cable is available in 20-ft. and is integral with the conductivity cell. Electronics and sensor diagnostics reduces troubleshooting times. Trim value or 1-point solution calibration options accommodates individual calibration techniques and reduces calibration time. Temperature Sensor calibration options for more accurate measurements. Playing card-sized guide facilitates simple, correct, and consistent calibration and configuration. Watertight sensor connection for reliability in submersion applications. Global approvals including: CE Mark for industrial applications UL General Purpose CSA General Purpose IP66 Type 4x Enclosure FM Class I, Div. 1 (I.S.) Operator Interface The DirectLine electronics module configuration, calibration, and maintenance functions are performed locally from three buttons and a 4-digit, 7-segment LCD display on the front side of the electronics module. The process variable, temperature (if available), and any error diagnostics are viewable from the local LCD display. The following configuration functions are available. PV Type (Conductivity, Resistivity, TDS, and Concentration) TDS Factor Temperature Compensation Type Output configuration Noise suppression frequency selection A playing card-sized guide comes with each DirectLine sensor to guide you through a configuration or calibration quickly. FM Class I, Div. 2 (non-incendive field wiring) Electronics Module Integral Electronics/Sensor Design The DirectLine electronics module is loop-powered by 16-42 Vdc source and will modulate its supply current from 4-20 ma, depending upon the conductivity value sensed by the cell. The output cable connects to the electronics module by a waterproof connector. The DirectLine sensor s output cable connector is a standard M12 type receptacle. The M12 receptacle easily connects to a cord-set with an M12 connector or an M12 field wiring connector and customer-supplied cable. The DL423 module quickly attaches to the cell and is easily locked-in-place for assured safety and reliability during operation. The cell can be removed from the module safely without disrupting power to the electronics. Online Diagnostics The DirectLine sensor continuously performs selfdiagnostics on both the electronics and sensor. These prioritized self-diagnostics help to minimize the time and expense of troubleshooting during start-ups, maintenance, and calibrations. If a problem arises with either the module electronics or the sensor, the software prioritizes the problem type and displays only the highest priority error diagnostic thus simplifying the troubleshooting process. Once the diagnostic is corrected, the error code disappears from the display. If the electrode s temperature or process variable value goes out of operation range, the output current is driven to approximately 21.8 ma to inform the host device of a problem. Once the problem is corrected, the output current is returned back to normal and the error code disappears. Error codes are also used to indicate calibration failures.

DL423 DirectLine Sensor Module for Conductivity Measurement 3 Conductivity Cells Honeywell's extensive lines of conductivity cells are compatible with the DL423 Sensor Module. These cells are ruggedly constructed for reliable, continuous measurement of electrolytic conductivity up to 140ºC and 250 psig. The DL4000 line of conductivity cells are used with the DL423. An integral or remote configuration is available, depending on the process installation. The integral conductivity cell design can be used for in-line and flow cell types of installations. For immersion or ball valve mountings, a remote cell design is required. The remote cell design employs a cable integral to the cell that is connected to the DirectLine Sensor Module. The conductivity cell bodies are constructed of polyethersulfone (PES) for excellent corrosion resistance in a wide range of applications. Cell constants are available for applications ranging from ultrapure water to acid/base concentrations. DL4000 Conductivity Cells have an EEPROM with the cell constant and cell calibration factor programmed into it. These values are automatically uploaded into the DirectLine Sensor Module. This eliminates the need for the user to manually do this and reduces configuration errors.

DL423 DirectLine Sensor Module for Conductivity Measurement 4 Specifications Display Ranges Displayed Temperature Range Display Accuracy Display Resolution Process Temperature Electronics Module Ambient Temperature Output Type Output Calibration Cell Constant and Cell Calibration Factor Input Output (Loop) Cable Connection Output (Loop) User Termination Cable Lengths Remote Sensor: Output: Power Local Display and Buttons Conductivity: 0 to 2000 S/cm, 0 to 20.00 ms/cm, 0 to 1000 ms/cm Resistivity: 0 to 20.00 M-cm Total Dissolved Solids (TDS): 0 to 2000 ppm, 0 to 2000 ppb, 0 to 200ppt % Concentration: 0 to 20.00% 10 C to +140 C (14 F to 284 F) Conductivity/Resistivity: Greater of +/- 2 counts or +/- 0.5% of reading Concentration: +/- 0.5% of reading Temperature: +/- 0.1 C from 10 to 99.9 C, +/- 1 C from 100 to 140 C 4 digits, floating decimal point 10 C to +140 C (14 F to 284 F) 20 C to +85 C ( 4 F to +185 F) 4-20 ma (2-wire loop powered) 4-20 ma Automatic from EEPROM in Conductivity Cell M12 Type Tinned leads on cord set or customer supplied cable 20 feet (cable integral to conductivity cell) 20 feet or 50 feet 16-42 Vdc, 23mA max Maximum load resistance: LCD 4-digit, 7-segment 250 ohms at 16 Vdc 600 ohms at 24 Vdc 1400 ohms at 42 Vdc Engineering Units (Labels) S/cm, ms/cm, M-cm, ppm TDS, ppb TDS, ppt TDS, % Calibration Options Solution Temperature Compensation Diagnostics Case Approvals Remote Mounting Cal Trim Factor, 1 Point Cal Solution Acid (Cation/Ammonia), Salt (Neutral Salts), NaCl, HCl, NaOH, H 2 SO 4, and None (for USP24 Conformance) Sensor and electronics Weatherproof, corrosion-resistant plastic housing CE Mark for Industrial Applications UL General Purpose for Process Control CSA General Purpose for Process Control FM Intrinsically Safe, Class I, Div. 1, Groups A, B, C, D and Class I, Zone 0, AEx ia IIC FM Class I, Div. 2, Groups A, B, C, D and Class I, Zone 2, Groups IIC Enclosure: Type 4x, IP66 Pipe, Wall, or DIN Rail Dimensions H 123 mm (4.84 ) x W 48 mm (1.89 ) x D 46 mm (1.81 ) Weight Approximately 142 g (5.0 oz.)

DL423 DirectLine Sensor Module for Conductivity Measurement 5 Dimensions 48 mm 1.9 in. M O D E 1 2 132.6 mm 5.22 in. M O D E 1 2 Electronics Module Front View Locking Screw in Rear of Housing 46 mm 1.8 in. Conductivity Cell Side View Figure 2 Dimensions Figure 3 Integral Mounting

DL423 DirectLine Sensor Module for Conductivity Measurement 6 Mounting Electronics Module M O D E 1 2 Remote Connector Cover Strain Relief Compression Cap Terminals for Electrode Wiring Remote Integral Cable 20 Feet Cell Figure 4 Remote Mounting

DL423 DirectLine Sensor Module for Conductivity Measurement 7 Mounting Hose Clamp Slot for Pipe Mounting (Hose Clamp included in kit) Through Hole for DIN Rail Mounting Metal clip for U DIN rail mounting Mounting Kit Gray clip for G DIN rail mounting View from End View from End Panel Panel Terminal Connectors Barriers, Repeater, Isolators Front View Front View U Style DIN Rail G Style DIN Rail Figure 5 Remote Mounting Hardware

DL423 DirectLine Sensor Module for Conductivity Measurement 8 Model Selection Guide Notes: 1 Customer supplies cordset or cable with M12 connecter. Suppliers & P/Ns include: Phoenix Contact Turck Cord--set SAC-3P-5.0-PUR/M12FSSH Stainless RKV4T-6/S618 M12 Field W iring Connector SACC-M12FS-4CON-PG7 B8141-0 Cable 2-wire twisted shielded pair 2 Recommended cable is 2-wire twisted shielded pair RESTRICTIONS Restriction Letters d e Available O nly W ith Table Selection IIl A III B Table N ot Available W ith Selection ORDERING INSTRUCTIONS: 1. Part numbers are provided to facilitate Distributor Stock. 2. Orders may be placed either by model selection or by part number. 3. Part numbers are shown within the model selection tables to assist with compatibility information. 4. Orders placed by model selection are systematically protected against incompatibility. 5. Compatibility assessment is the responsibility of the purchaser for orders placed by part number. 6. Items labeled as N/A are not available via the stocking program and must be ordered by model selection.

DL423 DirectLine Sensor Module for Conductivity Measurement 9 Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For More Information Learn more about how Honeywell s DL423 DirectLine Sensor Module for Conductivity Measurement can provide unequaled savings during installation, startup, operation, and maintenance, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 70-82-03-47 January 2003 2010 Honeywell International Inc.