How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.

Similar documents
Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Valve timing. Atmospheric air

Model Selection. Data. Selection Graph. Selection Graph (2) Piping Capacity by Tube I.D.

External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series

Air. Pressure. Motion. nnnnnnnn

Drain Separator for Vacuum

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series

Pressure Switches Precautions 1 Be sure to read this before handling.

Vacuum Ejector Variations

Space Saving Vacuum Ejector Vacuum Pump System MODEL / Series / Product Number

Vacuum related component model series variation

Vacuum Generators. Ejector for Various Piping Conditions

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum generators VADM/VADMI

MVG. Modular Vacuum Grippers. US5

multi-stage vacuum generators - general information

M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves

Monitored Pneumatic Valves On Series Ported Manifold

Vacuum generators VADM/VADMI

½ Monitored Pneumatic Valves On Series Ported Manifold

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Multistage Ejector MODEL / Series / Product Number

Membrane Air Dryer IDG10,IDG10H IDG20,IDG20H

Membrane Air Dryer IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Self-regulating vacuum pumps. Characteristics. bar (Nl/s) Specifications

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

½ Monitored Pneumatic Valve Patented Technology

Noiseless Heater Vacuum Relief Valve

Sierra Series 900 Single & Dual Channel System. Instruction Manual

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Introduction pisave optimize pisave onoff pisave release pisave sense pisave restrict...488

¼ Dosing and Transfer Pump. Same Great Name. Revolutionary New Design.

Electron Microscopy Sciences

Vacuum generation Content

Refrigerated Air Dryer

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Differential pressure gauge with electrical contact type Model: P650 series

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

HEB Series. Thermoelectric Bath

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

1998 Expedition/Navigator Workshop Manual

Two-Channel Gas Controller

General Specifications

Flopurge TS. Operation Manual

Datasheet: K-22 LO Sensor

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

L. Terminal block Connecting Label:

Self-regulating vacuum pumps. Characteristics. Ø max. vacuum air drawn in L2 model nozzle (%) Specifications. Curves: see page 9/27.

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

Climate Control System

HEB Series. Peltier-Type Thermoelectric Bath

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Refrigerated Air Dryer

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors


Technical Specification PILATUS 100K Detector System

Vacuum generators VAD/VAK

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MANUAL RESET ALARM RELEASE

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Thermoelectric Bath. Series HEB

SC-500 ENGINEER S MANUAL

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

MANUAL RESET ALARM RELEASE

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Pioneer-R16 Gas Monitor Operator s Manual

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

Temperature Controllers

Class 1 laser beam sensor safe for your eyes

Vacuum- Generation and Monitoring. Product brochure 2015/16. > Vacuum Generation. > Vacuum Monitoring. Ejectors for efficient vacuum generation

Specification/ Data Sheet

C19 UNIVEX. High Vacuum Experimentation Systems UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

Refrigerated Air Dryer

Vacuum system component SELVACS

Analog Room Pressure Monitor RPC Series

CAUTION. No-Load Performance, Controls in Normal Position

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Class 1 laser beam sensor safe for your eyes

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

RAM 50 Series Operation Manual

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Class 1 laser beam sensor safe for your eyes

Transcription:

Vacuum Module: Vacuum Pump System Series ZX How to Order Valve unit N.C. type Components unit ZX100 K1 Combination of supply valve and release valve Pilot valve Voltage Electrical entry Light/Surge voltage suppressor Manual operation unit Filter unit Electrical entry 5 L Z E C PV/V port size Valve unit N.O. type unit ZX100 K3 5 L Z E C Valve unit N.C. type L LN LO M MN MO G H Filter unit ZX100 K1 Valve unit/combination of supply valve and release valve Refer to Table (1) on page 13-2-41. Pilot valve Caution When using the AC type, the DC solenoids are operated via a rectifier. Therefore, when using this type, make sure to combine the connector assembly equipped with a rectifier with the exclusive solenoids. Using other combinations could lead to burned coils or other types of malfunctions. Refer to page 13-2-54 for ordering the manifold. Refer to page 13-2-64 to 65 for ordering a unit for replacement. Plug connector type Grommet type DC: 1 W (With indicator light: 1.05 W) AC Y DC: 0.45 W (With indicator light: 0.5 W) 24 VDC and 12 VDC are applicable to 0.45 W. Note) In the case of K1 (combination of supply and release valves), M type plug connector can not be used. Refer to Table (2) on page 13-2-41 for part number of lead wire with connector. Voltage 1 100 VAC 50/60 Hz 3 110 VAC 50/60 Hz 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC Air operated (K6, K8, J3, J4, D3, D4) Applicable to plug connector. (Connector assembly with rectifier is attached.) Electrical entry 5 L Z Lead wire length 0.3 m Without lead wire (Applicable to DC only) Without connector Lead wire length 0.3 m Without lead wire (Applicable to DC only) Without connector Lead wire length 0.3 m (Applicable to DC only) Lead wire length 0.6 m (Applicable to DC only) Air operated F Manual operation B PV/V port size Y Non-locking push type Locking slotted type Light/Surge voltage suppressor None Z With light/surge voltage suppressor S With surge voltage suppressor Caution M5 x 0.8 M6 x 1 (Option) unit/filter unit E PS PB F electrical entry L C CL CN Grommet type Connector type Lead wire length 0.6 m Lead wire length 3 m Lead wire length 0.6 m Lead wire length 3 m Without connector (Without lead wire) (For general purpose) Adsorption Nozzle dia. (ø0.3 to 0.7) confirmation switch Nozzle dia. (ø0.5 to 1.2) Only suction filter Vacuum digital pressure switch unit D DP Surge voltage suppressor Red Black Diode Coil Light/Surge voltage suppressor Refer to Table (3) on page 13-2-41 for part number of lead wire with connector. With suction filter 21 2 outputs/without analog output 22 2 outputs/with analog output kpa 23 1 output (with trouble detection)/without analog 24 1 output (with trouble detection)/with analog Note) Analog output is available on grommet type only. Coil In the case of AC, S is not available. Using the DC type: Match the polarity of the connectors according to the + and marks on the connectors. Do not interchange the polarities to prevent the diodes or the switching elements from becoming burned. If lead wires are pre-connected, the red wire is + and the black wire is. Using the AC type: The AC type is not equipped with a surge voltage suppressor because the rectifier assembly prevents the generation of surge voltage. 13-2-40

Vacuum Module: Vacuum Pump System Series ZX Table (1) Valve Unit/Combination of Supply Valve and Release Valve Solenoid (N.C.) Solenoid (N.O.) Air operated (N.O.) Air operated (N.O.) Components Solenoid (N.C.) Solenoid (N.C.) External release Air operated (N.C.) Table (2) Valve Unit/Valve Plug Connector Assembly Connector assemby part no. (For DC) VJ10 20 4A 6 (For 100 VAC) VJ10 VJ10 6 10 15 20 25 30 36 (For 110 VAC) 36 1A 3A 6 6 Lead wire length 0.3 m (Standard) 0.6 m 1 m 1.5 m 2 m 2.5 m 3 m Symbol K1 K3 K6 K8 Air operated N.O. N.C. (VJ324) (ZX1A) N.C. (VJ114) How to order If ordering vacuum module with 600 m or the longer lead wire, specify both vacuum module and connector assemby part numbers. Ordering example) ZX100-K15LOZ-EC 1 pc. VJ10-20-4A-6 2 pcs. N.O. (VJA324) None N.C. (VJ114) Without valve module N.C. (VJ314) Air operated N.C. (VJA314) Table (3) Vacuum Switch/Plug Connector Assembly ZS (Refer to page 13-2-42 for details specifications.) 10 30 50 5A Lead wire length 0.6 m 3 m 5 m Note) If ordering switch with 5 m lead wire, specify both switch and lead wire with connector part numbers. Ordering example) ZX100-K150Z-ECN 1 pc. VJ10-20-4A-6 2 pcs. ZS-10-5A-50 1 pc. External release ZX1A None ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Vacuum Pump System/Recommended Model (The models below will have faster delivery.) Model (Pilot valve) N.C. ZX100-K15LZ-F (VJ114) N.C. ZX100-K15LZ-EC (VJ114) N.O. ZX100-K35MZ-EC (VJ324) The above models are for short delivery. Combination (Direct operated) N.C. (VJ114) N.C. (VJ114) N.C. (VJ314) rated voltage Lead wire electrical entry Light/Surge voltage suppressor unit /Filter unit electrical entry Suction filter (ZX1-F) With Plug light/surge 24 VDC connector voltage Connector type type suppressor (ZSE) ZX100-K15LZ-E ZX100-K35MZ-E 13-2-41

Vacuum Pump System/Combination of Supply Valve and Release Valve Combination Symbol: K1 An N.C. solenoid valve is used for the supply valve. Also, an N.C. solenoid valve is used for the vacuum release valve. Application: This combination is used for effecting control in accordance with electric signals. Combination Symbol: K6 An external 3 port valve must be provided to serve as the supply valve. Also, an external 2 port valve (vacuum valve) must be provided to serve as the vacuum release valve. Application: This combination is used for effecting control in accordance with electric signals. External release port Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: K3 An N.O. solenoid valve is used for the supply valve. Also, an N.C. solenoid valve is used for the vacuum release valve. Application: This combination is used for effecting control in accordance with electric signals. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This combination is used for preventing the workpieces from dropping during power outages. Combination Symbol: K8 An air operated N.O. valve is used as the supply valve. An air operated N.C. valve is used for the vacuum release valve. Application: This combination is used for effecting control in accordance with electric signals. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This type is used for preventing the workpieces from dropping during Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop Air operated valve Air operated valve 13-2-42

Vacuum Module: Vacuum Pump System Series ZX Vacuum Pump System/Construction Component Parts No. q w e r t y u i Note) Description Poppet valve assembly Release flow rate adjusting needle Manifold base Valve unit Interface plate Return spring Filter case Material Stainless steel Aluminum Stainless steel Polycarbonate Note ZX1-PV-O ZSE2, ZSP1 ZX1-VB -D- (PV)/(PS PD) Replacement Parts No. o!0 Description Pilot valve Filter element Material PVF Part no. Refer to Table (2), (3). ZX1-FE Note) Caution when handling filter case 1. The case is made of polycarbonate. Therefore, do not use it with or expose it to the following chemicals: paint thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, watersoluble cutting oil (alkalinic), etc. 2. Do not expose it to direct sunlight. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Table (1) How to Order Pilot Valves No. 1 2 3 4 Component equipment N.C. (VJ114) N.C. (VJ114) N.O. (VJ324) N.C. (VJ314) Air operated Air operated N.O. (VJA324) N.C. (VJA314) Air operated Air operated Model ZX1-VJ114- ZX1-VJ3 1 24 - ZX1-VJA3 1 24 Table (2) How to Order Solenoid Valves Type of actuation 1 2 N.C. (Normally closed) N.O. (Normally open) Pilot valve DC: 1 W (With indicator light: 1.05 W) AC DC: 0.45 W Y (With indicator light: 0.5 W) Combination of supply and release valve K1, J1 K3, J2 K6 No. 2 and 3 models only are applicable. Indicate each part number. ZX1-VJ114 5 ZX1-VJ3 2 4 5 Body option Pilot valve Individual exhaust Common exhaust for M main and pilot valves Note) In the case of N.C. type, indicate no symbol. (Individual exhaust for Pilot valve) 24 VDC and 12 VDC are applicable to 0.45 W. Note) Screw length of VJ100 and VJ300 for series ZX is different from that of the standard model. <Screw length> VJ100 M1.7 x 15 L L Z Z Table (3) How to Order Air Operated Valves ZX1A M3 Caution Port size M3 M3 x 0.5 M5 M5 x 0.8 Turning the vacuum release flow volume adjusting needle clockwise reduces the vacuum release flow volume; the needle valve is fully closed when the needle stops turning. Turning the needle 2 full turns counterclockwise from the fully closed position renders the needle valve fully open. The needle will fall out if it is turned more than 4 full turns. Light/Surge voltage suppressor Without light/surge voltage suppressor S With surge voltage suppressor Z With light/surge voltage suppressor Rated voltage 1 100 VAC 3 110 VAC 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC Applicable to plug connector /External release port Manual override B Non-locking push type Locking slotted type Electrical entry L Connector (0.3 m) LN Connector (W/o lead wire) LO Without connector M Connector (0.3 m) MN Connector (W/o lead wire) MO Without connector G Grommet (0.3 m) H Grommet (0.6 m) Note) In the case of ZX1- VJ114, M, MN and MO cannot be used. 13-2-43

Valve Unit: ZX1-VB Refer to page 13-2-10 for details. Specifications Unit no. Components Operation Effective area (mm 2 ) (Cv factor) Operating pressure range Max. operating frequency Operating temperature range Interface plate symbol Standard accessory ZX1-VB valve Vacuum release valve Pilot type Direct operated type Air operated External Air N.C. N.O. N.C. N.O. N.C. N.C. release operated (VJ114) (VJ324) (ZX1A) (VJA324) (VJ114) (VJ314) (ZX1A) (VJA314) 3 (0.17) Main valve 0.07 0.45 0.004 0.025 0.3 to 0.6 MPa 5 Hz 5 to 50 C (PV) / (PS PD) Bracket B/Spacer 2 Pilot exhaust PE port valve air supply PS port Vacuum supply PV port Vacuum pad connection A port K1 (Normally closed) Pilot exhaust PE port Vacuum supply PV port valve air supply PS port Vacuum pad connection A port K3 (Normally open) 57.4 7 11.5 20 1 8 Manual override Manual override (Push and turn (Non-locking) Bracket B the locking type Bracket B (Standard override.) accessory) (Standard accessory) Supply valve Release flow rate N.O. Manual override adjusting needle (PE port) (PS port) Air supply port for vacuum switch valve Interface plate (PV port) Vacuum supply pressure port 1 35.4 (A port) Vacuum pad connection port 5.4 70 (PE port) (PS port) Air supply port for vacuum switch valve Release flow rate adjusting needle Interface plate 79.1 7 1 (PV port) Vacuum supply pressure port 20 11.5 1 8 35.4 5.4 (V port) Vacuum pad connection port 83.9 Note) Dimensions : For mounting bracket B : For mounting spacer 13-2-44

Vacuum Module: Vacuum Pump System Series ZX Suction Filter Unit: ZX1-F Refer to page 13-2-12 for details. Vacuum Pressure Switch High speed response/10 ms Uses a carrier diffusion semiconductor pressure sensor Adsorption Confirmation Switch Suitable for small size adsorption nozzle/ø0.3 to ø1.2 With suction filter Improved wiring: connector type Uses a carrier diffusion semiconductor pressure sensor Specifications Vacuum Pressure Switch Unit/ZSE2, ZSE3, ZSP1 Unit no. ZX1-F Operating pressure range Vacuum to 0.5 MPa Operating temperature range 5 to 50 C Filtration efficiency 30 µm Element PVF Weight 35 g Note) If not operated within the specified range of pressure and temperature, trouble may be caused. Vacuum Pressure Switch Specifications Unit no. ZSE2-0X ZSE3-0X Fluid Set pressure range Hysteresis Accuracy Voltage Port size Air 0 to 101 kpa 3% Full span or less 12 to 24 VDC (Ripple ±10% or less) M5 x 0.8 ±3% Full span (5 to 40 C) ±1% ±5% Full span (0 to 60 C) Full span Note) If not operated within the specified range of pressure and temperature, trouble may be caused. Adsorption Confirmation Switch Specifications Unit no. Fluid Operating pressure range Applicable adsorption nozzle dia. Hysteresis Internal orifice Filter case Caution 1. The case is made of polycarbonate. Therefore, do not use it with or expose it to the following chemicals: paint thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, water-soluble cutting oil (alkalinic), etc. 2. Do not expose it to direct sunlight. Refer to page 13-2-13 to 13-2-18 for details. Refer to Best Pneumatics Vol.16 for details. ZSP1-S ZSP1-B Air 20 to 101 kpa ø0.3 to ø0.7 ø0.5 to ø1.2 0.5 kpa ø0.5 ø0.8 ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. Other caution Caution It might not be possible to successfully pick a workpiece if a picking nozzle or a picking pad that is out of the applicable range is used. 13-2-45

Valve Unit: Type K1 Configuration and combination Valve unit (K1) + Model ZX100 K1 (ZSE2) (ZSE3) Adsorption confirmation switch (ZSP1) E D P F Pilot exhaust PE port valve air supply PS port Vacuum supply PV port Vacuum pad connection V port Circuit diagram (Circuits other than those with vacuum switch are shown as below.) Vacuum switch (E) (ZSE2) ZX100-K1 -E Adsorption confirmation switch (P) Spacer 1 (For side mounting) Pressure sensor (Release to atmospheric pressure) Manual override Pressure setting trimmer 41 1 17.6 19 13.6 (PD port) Interface plate Release flow rate adjusting needle (Mounting hole) (68.6) (PE port) (PS port) Air supply port for vacuum Pitch = 10 switch valve (PV port) Vacuum supply pressure port 15.5 Bracket A (Standard accessory) 4 Vacuum pad connection port Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-46

Vacuum Module: Vacuum Pump System Series ZX (ZSE3) ZX100-K1 -D Adsorption confirmation switch (ZSP1) ZX100-K1 -P Adjustment needle Spacer 1: ZX1-S1 ZX Manual override (Non-locking) DOWN button UP button RESET button SET button Spacer 1 (For side mounting) 1 41 1 10 22.6 19 18.7 17.8 19 ø3.6 ZR ZM ZH ZU (N.C.) Interface plate (PE port) (N.C.) Release flow rate adjustment needle Air supply pressure port (M3, PS port) Pitch = 10 (PV port) Vacuum supply pressure port M5 (V port) Vacuum pad connection port 15.5 4 18 M2.5 x 51 Phillips screw Bracket A (Standard accessory) Adsorption confirmation switch Adsorption nozzle piping port M5 x 0.8 (or M6 x 1) 2-ø3.3 mounting hole ZL ZY ZQ ZF ZP ZCU AMJ Misc. ZX100-K1 -F 41 1 19 8.8 4.8 Filter 13-2-47

Valve Unit: Type K3 Configuration and combination Valve unit (K3) + Model ZX100 E K3 P F (ZSE2) Adsorption confirmation switch (ZSP1) Pilot exhaust PE port valve air supply PS port Vacuum supply PV port Vacuum pad connection V port Circuit diagram (Circuits other than those with vacuum switch are shown as below.) Vacuum switch (E) (ZSE2) ZX100-K3 -E Pressure setting trimmer Spacer 1 (For side mounting) Adsorption confirmation switch (P) Pressure sensor (Release to atmospheric pressure) 41 1 Manual override (Push and turn the locking type override.) 7.6 19 13.6 N.O. Manual override Interface plate (PE port) Release flow rate adjusting needle (PS port) Air supply port for vacuum switch valve (PV port) Vacuum supply pressure port 15.5 4 18 (82.5) 2-ø3.3 mounting hole Bracket A (V port) (Standard accessory) Vacuum pad connection port Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-48

41 1 Vacuum Module: Vacuum Pump System Series ZX Adsorption confirmation switch (ZSP1) ZX100-K3 -P ZX100-K3 -F Adjustment needle 19 17.6 13.6 Adsorption confirmation switch 2-ø3.3 mounting hole 41 1 Spacer 1: ZX1-S1 Adsorption nozzle piping port M5 x 0.8 (or M6) 15.5 ø3.6 Bracket A (Standard accessory) 4 18 15.5 ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. 8.8 19 4.8 Filter unit (Mounting hole) 13-2-49

Valve Unit: Type K6 Configuration and combination Valve unit (K6) + Model K6 ZX100 (ZSE2) Adsorption confirmation switch (ZSP1) E P F Pilot air supply Pilot exhaust PE port Vacuum supply PV port External release air supply External release port Vacuum pad connection V port Circuit diagram (Circuits other than those with vacuum switch are shown as below.) Vacuum switch (E) (ZSE2) ZX100-K6-E Spacer 1 (For side mounting) Adsorption confirmation switch (P) M5 x 0.8 Pressure setting trimmer Pressure sensor (Release to atmospheric pressure) M5 x 0.8 External release port 41 1 ø3.6 19 13.6 Air operated External release Release flow rate adjusting needle Interface plate 15.5 18 (63.5) (PE port) (PV port) Vacuum supply pressure port 2-ø3.3 Mounting hole Bracket A (Standard accessory) 4 (V port) Vacuum pad connection port Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-50

Vacuum Module: Vacuum Pump System Series ZX Adsorption confirmation switch (ZSP1) ZX100-K6-P Adjusting needle Spacer 1: ZX1-S1 20 1 41 ZX ZR 17.8 19 ø3.6 ZM ZH ZU Adsorption confirmation switch ZL ZY ZQ 2-ø3.3 Mounting hole Adsorption nozzle piping port M5 x 0.8 (or M6 x 1) 15.5 Bracket A (Standard accessory) 4 18 (63.5) ZF ZP ZCU AMJ Misc. ZX100-K6-F 41 1 19 8.8 4.8 Filter unit (Mounting hole) 13-2-51

Valve Unit: Type K8 Configuration and combination Valve unit (K8) + Model ZX100 K8 (ZSE2) Adsorption confirmation switch (ZSP1) E P F Air supply for supply valve pilot Pilot exhaust PE port valve air supply PS port Vacuum supply PV port Air supply for release valve pilot Vacuum pad connection V port Circuit diagram (Circuits other than those with vacuum switch are shown as below.) Vacuum switch (E) (ZSE2) ZX100-K8-E Adsorption confirmation switch (P) M3 x 0.5 ( for supply valve) Pressure setting trimmer Spacer 1 (For side mounting) 41 1 Pressure sensor (Release to atmospheric pressure) M3 x 0.5 ( for release valve) 19 7.6 13.6 N.O. (Air operated VJA324) Manual override (Non-locking) Interface plate (Air operated VJA314) Release flow rate adjusting needle (PS port) Air supply port for vacuum switch valve 15.5 18 63.5 (PE port) (PV port) Vacuum supply pressure port 2-ø3.3 Mounting hole Bracket A (Standard accessory) 4 (V port) Vacuum pad connection port Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-52

Vacuum Module: Vacuum Pump System Series ZX Adsorption confirmation switch (ZSP1) ZX100-K8-P Spacer 1: ZX1-S1 Adjusting needle 17.6 19 13.6 Adsorption confirmation switch 41 1 2-ø3.3 Mounting hole 15.5 Bracket A (Standard accessory) ø3.6 18 4 (V port) Adsorption nozzle piping port ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc. ZX100-K8-F 41 1 19 8.8 4.8 Filter unit 13-2-53

Made to Order Specifications: Please consult with SMC for detailed specifications, size and delivery. 1. Valve Unit/Other Combinations of Supply Valve and Release Valve (Ejector unit) Ejector Unit If those other than the standard combination of supply valves and release valves (Refer to page 13-2-5.) are required, select from the following combinations. (Refer to page 13-2-4 for How to Order.) Combination Symbol: K2 Combination Symbol: K7 External release port Combination Symbol: K4 Combination Symbol: K5 An N.C. solenoid valve is used as the supply valve. Also, an external 2 port valve (vacuum valve) must be provided to serve as the vacuum release valve. controlled by electric signals and a vacuum release is effected by external air. Valve Condition External 2 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop An N.O. solenoid valve is used as the supply valve. An air operated N.C. valve is used for the vacuum release valve. restricted by electric signals and a vacuum release is effected by air signals. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This combination is used for preventing the workpieces from dropping during power outages. Valve Condition Air operated valve 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: J1 Combination Symbol: J2 An air operated N.O. valve is used as the supply valve. An N.C. solenoid valve is used for the vacuum release valve. controlled by external air signals and a vacuum release is effected by the solenoid valve. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This combination is used for preventing the workpieces from dropping during power outages. Valve Condition Air operated valve 1. Work adsorption 2. Vacuum release 3. Operation stop An N.C. solenoid valve is used as the supply valve. A vacuum release valve is not used. Application: This combination is used for effecting control in accordance with electric signals. A vacuum release is effected by the intrusion of air between the silencer, pad, and the workpiece. This combination is used when there is no need to accelerate the vacuum release speed. Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop An external 3 port valve must be provided to serve as the supply valve. Also, an N.C. solenoid valve is used for the vacuum release valve. controlled by external air signals and a vacuum release is effected by the solenoid valve. Valve Condition External 3 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop An N.O. solenoid valve is used as the supply valve. A vacuum release valve is not used. Application: It is used for controlling the supply pressure through electric signals. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This is used for preventing the workpieces from dropping during power outages. A vacuum release is effected by the intrusion of air between the silencer, pad, and the workpiece. This combination is used when there is no need to accelerate the vacuum release speed. Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop 13-2-68

Made to Order Specifications: Please consult with SMC for detailed specifications, size and delivery. ZX Combination Symbol: J3 An N.C. solenoid valve is used as the supply valve. A vacuum release valve is not used. controlled by external air signals. A vacuum release is effected by the intrusion of air between the silencer, pad, and the workpiece. This is used when there is no need to accelerate the vacuum release speed. Combination Symbol: D2 An N.C. solenoid valve is used for the vacuum release valve. An external supply valve must be provided. controlled by the external valve and a vacuum release is effected by the solenoid valve. ZR ZM ZH ZU ZL Valve Condition External 3 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop Valve Condition External valve 1. Work adsorption 2. Vacuum release 3. Operation stop ZY ZQ ZF ZP Combination Symbol: J4 An air operated N.O. valve is used as the supply valve. A vacuum release valve is not used. controlled by external air signals. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This is used for preventing the workpieces from dropping during power outages. A vacuum release is effected by the intrusion of air between the silencer, pad, and the workpiece. This type is used when there is no need to accelerate the vacuum release speed. Valve Condition Air operated valve 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: D3 External release port An external valve must be provided to serve as the supply valve. Also, an external 2 port valve (vacuum valve) must be provided to serve as the vacuum release valve. controlled by the external valve and a vacuum release is effected by the external 2 port valve (vacuum valve). Valve Condition External valve 1. Work adsorption 2. Vacuum release 3. Operation stop ZCU AMJ Misc. Combination Symbol: D1 An N.C. solenoid valve is used for the vacuum release valve. An external supply valve must be provided. controlled by the external valve and a vacuum release is effected by the solenoid valve. Combination Symbol: D4 An external valve must be provided to serve as the supply valve. An air operated N.C. valve is used for the vacuum release valve. controlled by the external valve and a vacuum release is effected by external air signals. Valve Condition External valve 1. Work adsorption 2. Vacuum release 3. Operation stop Valve Condition External valve Air operated valve 1. Work adsorption 2. Vacuum release 3. Operation stop 13-2-69

Made to Order Specifications: Please consult with SMC for detailed specifications, size and delivery. 1. Valve Unit/Other Combinations of Supply Valve and Release Valve (Vacuum pump system) Vacuum Pump System If those other than the standard combination of supply valves (Refer to page 13-2-41.) and release valves are required, select from the following combinations. (Refer to page 13-2-40 for How to Order.) Combination Symbol: K2 External release port Combination Symbol: K4 An N.C. solenoid valve is used as the supply valve. Also, an external 2 port valve (vacuum valve) must be provided to serve as the vacuum release valve. controlled by electric signals and a vacuum release is effected by external air. Valve Condition External 2 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop An N.O. solenoid valve is used as the supply valve. An air operated N.C. valve is used for the vacuum release valve. controlled by electric signals and a vacuum release is effected by air signals. Because the supply valve is N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This combination is used for preventing the workpieces from dropping during power outages. Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: K7 Combination Symbol: J1 An air operated N.O. valve is used as the supply valve. An N.C. solenoid valve is used for the vacuum release valve. controlled by external air signals and a vacuum release is effected by the solenoid valve. Because the supply valve is the N.O., the pressure that is supplied to the ejector is not interrupted during a power outage; as a result, the state of suction can be maintained. This combination is used for preventing the workpieces from dropping during power outages. Valve Condition Air operated valve 1. Work adsorption 2. Vacuum release 3. Operation stop An N.C. solenoid valve is used as the supply valve. A vacuum release valve is not used. Application: This combination is used for controlling the pressure by electric signals. Normally, the workpiece is released due to the air leakage that occurs between the pad and the workpiece. However, if there is no air leakage, the workpiece will not become detached because the vacuum state is maintained even when the supply valve is turned. To effect releasing, an external 2 port valve (vacuum valve) must be provided. Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: K5 An external 3 port valve must be provided to serve as the supply valve. Also, an N.C. solenoid valve is used for the vacuum release valve. controlled by external air signals and a vacuum release is effected by the solenoid valve. Combination Symbol: J2 An N.O. solenoid valve is used as the supply valve. A vacuum release valve is not used. Application: Used for controlling with electric signals. Because the supply N.O., the pressure is not interrupted during a power outage. This prevents the workpieces from dropping. Normally, the workpiece is released due to leakage. However, if no air leakage, the workpiece will not detach because the vacuum state is maintained even when the supply valve is turned. To release, an external 2 port valve (vacuum valve) must be used. Valve Condition External 3 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop Valve Condition 1. Work adsorption 2. Vacuum release 3. Operation stop 13-2-70

Made to Order Specifications: Please consult with SMC for detailed specifications, size and delivery. ZX Combination Symbol: J3 An N.C. solenoid valve is used as the supply valve. A vacuum release valve is not used. controlled by external air signals. Normally, the workpiece is released due to the air leakage that occurs between the pad and the workpiece. However, if there is no air leakage, the workpiece will not become detached because the vacuum state is maintained even when the supply valve is turned. To effect releasing, an external 2 port valve (vacuum valve) must be provided. Valve Condition External 3 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: D2 An N.C. solenoid valve is used as the vacuum release valve. A supply valve is not used. controlled by an external 2 port valve (vacuum valve) and a vacuum release is effected by the solenoid. Valve Condition External 2 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU Combination Symbol: J4 Combination Symbol: D1 An air operated N.O. valve is used as the supply valve. A vacuum release valve is not used. Application: Supply is controlled by external air signals. Because the valve is N.O., the pressure is not interrupted during a power outage. This prevents the workpieces from dropping. Normally, the workpiece is released due to leakage. However, if no leakage, the workpiece will not detach because the vacuum state is maintained even when the valve is turned. To release, an external 2 port valve (vacuum valve) must be provided. Valve Condition Air operated valve 1. Work adsorption 2. Vacuum release 3. Operation stop Combination Symbol: D3 External release port Combination Symbol: D4 An external 2 port valve (vacuum valve) must be provided to serve as the supply valve and the vacuum release valve. controlled by the external 2 port valve (vacuum valve) and releasing is also effected by the extermal 2 port valve. Valve Condition External 2 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop AMJ Misc. An N.C. solenoid valve is used as the vacuum release valve. A supply valve is not used. controlled by an external 2 port valve (vacuum valve) and a vacuum release is effected by the solenoid. An external 2 port valve (vacuum valve) must be provided to serve as the supply valve. An air operated N.C. valve is used for the vacuum release valve. controlled by the external 2 port valve (vacuum valve) and vacuum release is effected by external air signals. Valve Condition External 2 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop Valve Condition External 2 port valve 1. Work adsorption 2. Vacuum release 3. Operation stop 13-2-71

Made to Order Specifications: Please consult SMC for detailed specifications, size and delivery. 1. Noise Reduction Silencer Assembly/The ejector exhaust style is applicable to the silencer equipped specifications. ZX1 Nozzle diameter Exhaust style Valve Voltage Electrical entry X121 Noise reduction silencer assembly Reduction in the exhaust noise from the ejector (Silencing effect 8 db (A) Standard silencer assembly comparison) Noise reduction silencer assembly ZX1-HS1 Ordering example ZX1101-K35LZ-D23C-X121 Noise reduction silencer assemby ZX1-HS1 P3270147-23 Phillips screw (M2 x 23) P3200223-2 Noise absorbing material G P3200224-1 Silencer case F P3200225 Silencer case E Noise reduction silencer assembly ZX1-HS1 Ordering example ZZX102-R ZX1101-K35LZ-EC-X121 1 pc. 2 pcs. 13-2-72