SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

Similar documents
Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

Product Manual 806 B 06/06 D. Date: June 2006 Supersedes: 806B 04/11 C

AIR COOLED MINI CHILLER

DAIKIN Huizhou Factory Profile

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Water cooled screw chillers

ERACS.C-N Higher efficiency air-cooled screw pump

MAC-A R410A Series Air cooled Modular Chiller

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Air-Cooled Screw Compressor Chillers

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Leadership, Innovation, Advanced Technology Synergise Here!

Air Cooled Scroll Chiller

KELVIN Clim F497. Kelvin air conditioning

GeneSys. Air-Cooled Screw Compressor Chillers. Catalog

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Commercial and Technical Data

.2 Section Waste Management and Disposal.

Modular Air Cooled Scroll Chillers

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

MODULAR WATER-COOLED CHILLER

AQUASNAP JUNIOR 30RHV

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

kw COOLING kw HEATING

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

500 EX Fusion Compressor Series

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

CASE STUDY AIR-CONDITIONERS

GLIDER EVO GLIDER EVO. rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

PYXIS U PYXIS U. rcgroupairconditioning

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Call us today! (800)

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

MODULAR WATER-COOLED CHILLER

water-cooled CHILLERS

30HXC Nominal cooling capacity kw

ARV.

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

30RB /30RQ

Innovation for a Better & Greener Future

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

Water-Cooled Screw Compressor Chillers

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Call us today! (800)

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

pyxis u pyxis ua NEW rcgroupairconditioning

Call us today! (800)

30RH B Nominal cooling capacity kw Nominal heating capacity kw

water-cooled CHILLERS

Air cooled industrial chillers

OACS Outdoor Air-Cooled Central Chillers

Water-Cooled Screw Compressor Chillers

Hi-Pres Cooling Products Catalogue. Product Catalogue

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

MODELS LIST. Nominal Capacity RT

Contour TM Screw Compressors

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Index Features and advantages... 3 General characteristics... 5 Nomenclature... 9 Technical Specifications Sound levels...

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Aquaflair TRAC-TRAF-TRAH

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

DAIKIN Modular Inverter Air Cooled Chiller

Air-Cooled Condensing Units with Compact Screw Compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Transcription:

MHS-F HR-2011 SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY MODEL: MCS050.1-380.2FSP MHS050.1-380.2FSP MHS050.1-235.2FSR COOLING CAPACITY: 164KW-1370KW HEATING CAPACITY: 172KW-1439KW PARTIAL HEAT RECOVERY: 41kW-343kW TOTAL HEAT RECOVERY: 197KW-1008KW REFRIGERANT: R22, R407C

Overview Air cooled chilled hot water unit is a kind of central air-conditioning unit with air as the cooling (heating) source and water as the heat carrier. For the traditional air cooled heat pump unit, a large amount of condensing heat is generated during refrigeration and is discharged into the atmosphere, which not only leads to a waste of much energy but also brings heat pollution to the ambient environment. For saving energy, the building itself needs a large amount of domestic hot water supply. If all or part of the condensing heat can be recovered and used for domestic hot water production, not only the environmental pollution caused by the condensing heat will be reduced, but also the energy saving will be achieved. Heat recovering unit is to realize this function by a heat exchanger. High temperature water can be recovered from the high condensing temperature of the air cooled heat recovering unit. This unit can be widely used in the hospitals, hotels, restaurants, factories, bath centers, clubs, etc. As one of the pioneers that design and manufacture large air cooled heat pump units, McQuay has always been devoted to the technical improvement and innovation, and has taken the lead in many aspects in the technical development history of air cooled heat pump unit. MHS is a new air cooled heat pump unit that we have launched for Chinese market. McQuay has introduced the world leading single screw compressor technology to the air cooled heat pump unit, integrated the advanced control technology and adopted high efficiency refrigerant so that it becomes one of the eco-friendly air-conditioning units that have the best efficiency and energy saving performance and the quietest operation among the similar products in the world. At the same time, large fullperformance laboratory devices are built in the Shenzhen Plant so that every product will go through strict performance test before being delivered, thereby to ensure its quality and performance. ISO9001:2000 Quality Management System Certificate Nomenclature ISO14001:2004 Environment Management System Certificate Test Center is approved by CNAS The product has been granted the production license of national industrial products MHS 235.2 F SR 2 F AA E Export Specifications Power Supply: 380~400V/3Ph/50Hz Refrigerant : 2-R22; 4-R407C Unit : SR: standard total heat recovery SP: standard partial heat recovery Compressor Series Compressor Qty. Cooling Capacity (235usrt) McQuay Single Screw Air Cooled Heat Pump 2

Features High resistance, against corrosion The cabinet is made of galvanized steel and coated to provide a high resistance. The unit can be applied under different environment conditions. The rejected heat from exchanger doesn t bring any pollution and meets the ecology requirement. Easy to install and simple to maintain Once power supplies, water piping and water pump provided, no further equipment are needed. The chiller is fully equipped with the necessary electrical components. Our controller monitor the unit operation permanently. In case abnormity happens, the system can perform audio-video alarm and display the fault s cause to ease the maintenance. Stepless modulation high efficiency and saving energy McQuay s unique newest single screw compressor brings high EER. Multiple circuits design, each unit is configured with one or two compressors and each compressor is configured with an independent refrigerant system, which can meet the load requirements. The cooling capacity can be steles ranging from 12.5% to 100% by micro-processor control. Exact control and reliable operation With most advanced electric expansion valve, the unit can control the refrigerant flow as various conditions. Chilled water leaving temperature is controlled to ±0.2. In addition, various sensors can transmit the signals and data to the controller, so the unit components are timely checked in order to keep reliable unit operation. Multiple protections ensure the safety operation of the unit. Three-level password protection prevents non-professional personnel from errors and ensures a safety operation. The compressor start one by one, so the electric current is low to reduce the impact to electric network. Low noise and low vibration As the compact structure, the unit basement bears the loads of compressor, condenser, evaporator, oil separator and the weight of all related refrigerant piping. As our standard features, units are equipped with spring absorber. No vibration is expected from our unique type of F4 single screw compressor. The condenser fan is compete with high efficiency propeller fan, direct drive with low noise. The compressor sound insulation enclosure is provided as standard to decrease the compressor s operation noise effectively. Wide range of applications McQuay heat recovering unit can realize refrigeration and supply heat and domestic hot water. The heat recovering unit can produce hot water by the condensing heat generated in the refrigeration circulation. In the season when air-conditioner or refrigeration equipment is used, the hot water produced by the unit can meet the water supply for the bath use in the guest room, washing use in the kitchen and hot water demand in processing and others. Intelligent control The integrated intelligent control system of McQuay heat recovering unit includes the manmachine operation interface, unit control management, networking and communication, failure protection, alarming, etc. The operations can be implemented safely and automatically. 3

Features High efficiency and environmental protection Heat recovering by the McQuay heat recovering unit can be used to reduce the hot island effect caused by the waste heat emission and provide domestic hot water at the same time, which helps protect environment and reduce resource waste and operation costs. Cost-effective The heat recovering type of central air-conditioning can be installed simply without any field limitation. It is safe and has a service life. At the same time, the investment for boiler and the area covering by the boiler can be saved, which is quite convenient for the users. Energy-efficient The heat recovering technology adopted by McQuay heat recovering unit can enhance the cooling efficiency, reduce electric power consumption and extend the operation life of the unit. For the partial heat recovering air-conditioning unit, the heat exchanger on the heat recovering side will absorb part of the condensing heat. Then the heat load of the original condenser is reduced and the heat exchanging efficiency will be enhanced and the efficiency of the airconditioning unit will be increased as well. For the full heat recovering air-conditioning unit, all the condensing heat will be absorbed. So the power consumption by the fan of the original air side heat exchanger can be saved and the power consumption can be reduced significantly. Complete models McQuay provides a full range of recovering units, including partial heat recovering, chilling full heat recovering, heat pump full heat recovering, etc. They can be combined to substitute boiler and provide systematic solutions for the users. 4

Air Cooled Single Screw Heat Recovery Unit Operating Mode MCS050.1FSP~MCS380.2FSP Cooling: Chilled water side heat exchanger supplies chilled water to FCU, etc. Cooling + Heat Recovery: Chilled water side heat exchanger supplies chilled water to FCU + heat recovery side supplies hot water MHS050.1FSP~MHS380.2FSP Cooling: Chilled water side heat exchanger supplies chilled water to FCU, etc. Cooling + Heat Recovery: Chilled water side heat exchanger supplies chilled water to FCU + heat recovery side supplies hot water Heating: Chilled water side heat exchanger supplies hot water to FCU, etc Heating + Heat Recovery: Chilled water side heat exchanger supplies hot water to FCU + heat recovery side supplies hot water MHS050.1FSR~MHS185.1FSR Cooling: Chilled water side heat exchanger supplies chilled water to FCU, etc. Cooling + Heat recovery: Chilled water side heat exchanger supplies chilled water to FCU + heat recovery side supplies hot water Heating: Chilled water side heat exchanger supplies hot water to FCU, etc Heater: Only Heat recovery side is available to supply hot water Start periodly: Heating/Heater two modes run alternately as setting MHS200.2FSR~MHS235.2FSR (System1 + System 2) Cooling + Cooling Cooling & Heat recovery + Cooling & Heat recovery Cooling + Cooling & Heat recovery Heat recovery + Heater Heating + Heating Heater + Heater 5

Intelligent Network Controller The controller integrates the experience and technology, applying McQuay air cooled heat pump since last 30 years. It is equipped with forecast logical programming software to perform the best combination of compressor and fan at higher EER. The controller can check the parameters and settings and then act accordingly to improve the energy efficiency and maximum reliability. Main functions Multi protection,ensure unit high efficient and stable running. Unit cooling load auto adjusted based on evaporator outlet water temp. Outlet water temp controlled by PID, precision ±0.2 C. Compressor On/Off controlled according to average wear. Both Chinese and English are available. Unit operation status/temp/pressure data etc dispaly. Fault alarm and fault history display. Three-level password protection. Auto re-start after power failure (option). Timing switch on/off function (option). Building management system control (option), Modbus, LonWorks, BACnet are available. Main components (Inner controller) 1. Main controller MaicroTechⅡ Control type: PLC programming Software class: Class A Effective memory: Flash is 2M,and static is 256K Working condition: Temperature is between -20 C to 60 C, and relative humidity is 90% 2. PGD (Display) Language: Chinese or English Interface display: Large LCD, 4-line English or 2-line Chinese Working condition: Temperature is between -20 C to 60 C, and relative humidity is 90% Controlled distance: Effective controlled distance is 250m (AWG22 shielded twisted pair). 3. IO Expansion board No programming, Set the special address is available. 4. EVD200 5. No programming, Set the special address is available. PLC controller Building Management System control (optional) ModBus/LonWorks/BACnet protocol interfaces are available to meet centralized and building auto control. Network control 6

Single Screw Compressor Compression principles Suction: Gas flows through the suction port into open ends of available grooves. As the screw rotates, gate-rotor teeth enter the seal grooves in sequence, refrigerant gas in chambers defined by three sides of the grooves, the compressor casing and the gate-rotor tooth surface. Compression: Volume in each tooth chamber decreases as the screw rotates. Gas is continuously compressed until the groove leading edge passes the discharge port. Discharge: Release of gas into the discharge chamber ends the compression cycle. Gas continues to be discharged until the gate-rotor reduces groove volume to zero. With two gate-rotors equalized on opposite sides of the screw, this process occurs twice with each screw revolution, doubling the compressor capacity of the unit. 7

Single Screw Conpressor Features 1.3 Single Screw Compressor With leading technology, McQuay s semi-hermetic single screw compressor has such features as highefficiency, saving energy, stability, quietness, few operation components and long durability. Few operation components The single screw compressor is equipped with only five operation components: a screw rotor, two gaterotors and two energy adjusting slide valve. The screw rotor is parts painted aluminum, and the gaterotor is equipped with eleven-tooth high strength compound material. Long durability and high reliability With equalizing compression, the single screw can reduce the bearing load to extend the bearing durability. The gate-rotor, which is made of high-intension synthetic material, can keep exact and minimum clearance to ensure the operation is under no abrasion. The oil-ejection and liquid-ejection design of the compressor enables the overheat-gas declines to minimum, which eliminates to decompose the oil and refrigerant in overheat condition. Easy to maintain The gate-rotor box is designed with disassembly side cover, which makes the regular examine easy. Disassembling and installing the pipe provides direct way to examine the internal components of the compressor. Bearing durability The bearing durability of the single screw compressor is as three or five times as that of twin-screw compressor. Low noise and low vibration The single screw compressor performs complete balance load in operation, so its vibration is near to zero and its noise reaches the minimum of the industry standard. It does not contact metal completely in compression, which eliminates high-frequency noise. Abnormity discharge chamber design eliminates discharge noise. Gate-rotor and rotors The single screw compressor, with excellent unique design and special gate-rotor material, and no need for metal hermetic requirement between the gate-rotor and rotors, reaches zero-interval. The liquid refrigerant brings more effects as hermetic, lubricant and cooling material when the compressor rotors operate. What s more, its interval of the teeth is very little and the resistance is very low, which can improve the unit s efficiency. High-efficiency oil separator The system is equipped with high-efficiency oil separator to improve the oil separating efficiency to 99.7%, In this way, the reliability and efficiency are improved in compressor operation. Axial force balance With opposing and equal suction pressure at both ends of the screw member, the huge thrust loads of twinscrew compressor design are eliminated. Radial force balance Gate rotors on both sides of the screw member compressing simultaneously completely balanced radial loading on the rotating screw, nearly eliminates bearing wear. This is a sharp contrast with twin-screw designs whose bearing size is limited and higher loads directly impact bearing life. Twin-screw is with unbalance loading. Without balance compression, the twin-screw increases axial loads and radial loads, and it increases abrasion, which affects the bearing life. 8

Accessories Standard accessories (supplied on basic unit) Star Delta Compressors starter For low inrush current and reduced starting torque. Double set-point Dual leaving water temperature set-points. Compressor thermal overload relays Safety devices against compressor motor overloading in addition to the normal protection related to the electrical windings. Fan thermal overload relays Safety devices against fan motor overloading in addition to the normal protection related to the electrical windings. Phase protector The phase monitor controls the phases sequence is correct and controls phase loss. Evaporator electric heater Electric heater controlled by a thermostat to protect the evaporator from freezing down to -15 C ambient temperature. Victaulic evaporator water connection Hydraulic joint with gasket for an easy and quick water connection. General fault relay Contactor for alarm warning. Discharge line shut off valves Installed on the discharge port of the compressor. Flow switch Supplied separately to be wired and installed on the evaporator water piping (by the customer). Spring type vibration mounts Supplied separately, these have to be positioned under the base of the unit during installation. Ideal for dampening vibrations on roofs installation and metallic structures. Optional accessories (on request) Speed control Continuous fan speed modulation on the first fan of each circuit. It allows the unit working with air temperature down to -15 C. Golden and blue fin condenser Coil High pressure guages Low pressure guages Cu-Cu condenser coils To give better protection against corrosion by aggressive environments. 50/100 Pa lifts fans For all the applications where a higher fans lift is required. (Fan speed controller not available with this option). Soft start Electronic starting device to reduce inrush current and to start compressors gradually, with very low mechanical stress. BMS (Building Management System) protocol Modbus, LonWorks, BACnet 9

McQuay Single Screw Air Cooled Chiller (R22, SP partial heat recovery) MCS/MHS F SP 050.1 060.1 070.1 080.1 100.1 120.1 135.1 150.1 170.1 185.1 Cooling Capacity kw 170 205 240 280 360 422 455 525 625 654 USRT 48 58 68 80 102 120 129 149 178 186 Heating Capacity kw 179 215 252 294 378 443 478 551 656 687 USRT 49 59 69 81 104 122 132 152 181 189 Heat Recovery Capacity kw 43 51 60 70 90 106 114 131 156 164 Panel EG Capacity Adjusting Range 0,25~100% Power Supply V/Ph/Hz 380~400/3/50 R22 Refrigerant Circuit 1 Control Electronic Expansion Valve Model*Qty. HSS 3118*1 3120*1 3121*1 3122*1 3220*1 3221*1 4221*1 4222*1 4223*1 4223*1 Motor Power Input kw 49 59 69 78 102 120 126 149 182 170 Motor Power Input Compressor (Heating) kw 50 60 71 81 106 125 131 155 190 178 Sound Insulation Box Optional Polyurethane Foaming Start star-delta Cooling Liquid Injection Oil LPT68 Charge L 13 13 13 13 18 18 16 16 16 16 Crossed Fin and Tube Condenser FPI 14 Face Area m 2 9.57 9.57 12.07 12.07 16.09 16.09 16.09 20.12 20.12 24.14 Qty. 4 4 6 6 8 8 8 10 10 12 Fan Air Flow 104m 3 /h 8.8 8.8 13.2 13.2 17.6 17.6 17.6 22.0 22.0 26.4 Power Input kw 8.0 8.0 12.0 12.0 16.0 16.0 16.0 20.0 20.0 24.0 Shell and Tube Water Flow m 3 /h 29 35 41 48 62 73 78 90 107 112 Evaporator Water Flow (Heating) m 3 /h 31 37 43 51 65 76 82 95 113 118 WPD (kpa) 18 24 18 28 31 37 37 37 32 46 Connection inch 5 8 Heat Recovery Heat exchanger BPHE Length mm 2975 2975 3200 3200 4100 4100 4100 5000 5000 5900 Dimensions Width mm 2260 Height mm 2285 2360 MCS/transport kg 2385 2395 2905 2920 4090 4335 4335 4845 4850 5425 Weight MCS/operation kg 2535 2545 3055 3070 4240 4485 4485 5025 5030 5615 MHS/transport kg 2430 2440 2945 2970 4150 4415 4415 4920 4925 5495 MHS/operation kg 2580 2590 3095 3120 4300 4565 4565 5100 5105 5685 Accessories (Standard) Unit Operation Instruction, Confirmity Certification, Warranty Application Form, Spring Damper, Water Flow Switch Notes: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Nominal cooling capacity is based on the following conditions: 12/7 EWT and LWT,35 ambient temperature; 3. Nominal heating capacity is based on the following conditions: 40/45 EWT and LWT,7/6 ambient DB/WB temperature; 4. Heat recovery conditions are: 50/55 EWT and LWT of hot water, 12/7 EWT and LWT of chiller water. 10

McQuay Single Screw Air Cooled Chiller (R22, SP partial heat recovery) MCS/MHS F SP 200.2 220.2 235.2 260.2 285.2 310.2 330.2 350.2 380.2 Cooling Capacity kw 720 782 840 950 1000 1070 1163 1300 1370 USRT 205 222 239 270 284 304 331 370 390 Heating Capacity kw 756 821 882 998 1050 1124 1221 1365 1439 USRT 215 234 251 284 299 320 348 389 410 Heat Recovery Capacity kw 180 196 210 238 250 268 291 325 343 Panel EG Capacity Adjusting Range 0,12.5~100% Power Supply V/Ph/Hz 380~400/3/50 R22 Refrigerant Circuit 2 Control Electronic Expansion Valve Model*Qty. HSS 3220*2 3220*1 4221*1 4222*1 3221*2 4221*2 4222*2 3221*1 4222*1 4223*1 4223*2 4223*2 Motor Power Input kw 204 222 239 256 279 309 337 366 359 Motor Power Input Compressor (Heating) kw 214 233 251 268 293 324 354 384 377 Sound Insulation Box Polyurethane Foaming Start star-delta Cooling Liquid Injection Oil LPT68 Charge L 2*18 2*16 Crossed Fin and Tube Condenser FPI 14 Face Area m 2 28.16 30.18 32.19 32.19 34.20 36.21 38.22 40.23 40.23 Qty. 14 15 16 16 17 18 19 20 20 Fan Air Flow 104m 3 /h 30.8 33.0 35.2 35.2 37.4 39.6 41.8 44.0 44.0 Power Input kw 28.0 30.0 32.0 32.0 34.0 36.0 38.0 40.0 40.0 Shell and Tube Water Flow m 3 /h 124 135 144 163 172 184 200 224 236 Evaporator Water Flow(Heating) m 3 /h 130 141 152 172 181 193 210 235 247 WPD (kpa) 55 41 53 63 78 74 87 90 79 Connection inch 8 Heat Recovery Heat exchanger BPHE Length mm 7300 8200 8200 8200 9100 9100 10000 10000 10000 Dimensions Width mm 2260 Height mm 2360 MCS/transport kg 7155 7735 8235 8280 8705 8745 9495 9560 9885 Weight MCS/operation kg 7345 7925 8425 8480 8905 8945 9695 9760 10115 MHS/transport kg 7275 7885 8385 8430 8855 8895 9645 9710 10035 MHS/operation kg 7465 8075 8575 8630 9055 9095 9845 9910 10265 Accessories (Standard) Unit Operation Instruction, Confirmity Certification, Warranty Application Form, Spring Damper, Water Flow Switch Notes: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Nominal cooling capacity is based on the following conditions: 12/7 EWT and LWT,35 ambient temperature; 3. Nominal heating capacity is based on the following conditions: 40/45 EWT and LWT,7/6 ambient DB/WB temperature; 4. Heat recovery conditions are: 50/55 EWT and LWT of hot water, 12/7 EWT and LWT of chiller water. 11

McQuay Single Screw Air Cooled Chiller (R407C, SP partial heat recovery) MCS/MHS F SP 050.1 060.1 070.1 080.1 100.1 120.1 135.1 150.1 170.1 185.1 Cooling Capacity kw 164 198 232 270 347 407 439 507 603 631 USRT 47 56 66 77 99 116 125 144 172 179 Heating Capacity kw 172 208 243 284 365 428 461 532 633 663 USRT 49 59 69 81 104 122 132 152 181 189 Heat Recovery Capacity kw 41 49 58 68 87 102 110 127 151 158 Panel EG Capacity Adjusting Range 0,25~100% Power Supply V/Ph/Hz 380~400/3/50 R407C Refrigerant Circuit 1 Control Electronic Expansion Valve Model*Qty. HSS 3118*1 3120*1 3121*1 3122*1 3220*1 3221*1 4221*1 4222*1 4223*1 4223*1 Motor Power Input kw 49 59 69 78 108 127 133 157 192 180 Motor Power Input Compressor (Heating) kw 50 60 71 81 112 132 139 164 201 188 Sound Insulation Box Optional Polyurethane Foaming Start star-delta Cooling Liquid Injection Oil RL68H Charge L 13 13 13 13 18 18 16 16 16 16 Crossed Fin and Tube Condenser FPI 14 Face Area m 2 9.57 9.57 12.07 12.07 16.09 16.09 16.09 20.12 20.12 24.14 Qty. 4 4 6 6 8 8 8 10 10 12 Fan Air Flow 104m 3 /h 8.8 8.8 13.2 13.2 17.6 17.6 17.6 22.0 22.0 26.4 Power Input kw 8.0 8.0 12.0 12.0 16.0 16.0 16.0 20.0 20.0 24.0 Shell and Tube Water Flow m 3 /h 28 34 40 46 60 70 76 87 104 109 Evaporator Water Flow (Heating) m 3 /h 30 36 42 49 63 74 79 91 109 114 WPD (kpa) 18 24 18 28 31 37 37 37 32 46 Connection inch 5 8 Heat Recovery Heat exchanger BPHE Length mm 2975 2975 3200 3200 4100 4100 4100 5000 5000 5900 Dimensions Width mm 2260 Height mm 2285 2360 MCS/transport kg 2385 2395 2905 2920 4090 4335 4335 4845 4850 5425 Weight MCS/operation kg 2535 2545 3055 3070 4240 4485 4485 5025 5030 5615 MHS/transport kg 2430 2440 2945 2970 4150 4415 4415 4920 4925 5495 MHS/operation kg 2580 2590 3095 3120 4300 4565 4565 5100 5105 5685 Accessories (Standard) Unit Operation Instruction, Confirmity Certification, Warranty Application Form, Spring Damper, Water Flow Switch Notes: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Nominal cooling capacity is based on the following conditions: 12/7 EWT and LWT,35 ambient temperature; 3. Nominal heating capacity is based on the following conditions: 40/45 EWT and LWT,7/6 ambient DB/WB temperature; 4. Heat recovery conditions are: 50/55 EWT and LWT of hot water, 12/7 EWT and LWT of chiller water. 12

McQuay Single Screw Air Cooled Chiller (R407C, SP partial heat recovery) MCS/MHS F SP 200.2 220.2 235.2 260.2 285.2 310.2 330.2 350.2 Cooling Capacity kw 695 755 811 917 965 1033 1122 1255 USRT 198 215 231 261 274 294 319 357 Heating Capacity kw 730 792 851 963 1013 1084 1178 1317 USRT 215 234 251 284 299 320 348 389 Heat Recovery Capacity kw 174 189 203 229 241 258 281 314 Panel EG Capacity Adjusting Range 0,12.5~100% Power Supply V/Ph/Hz 380~400/3/50 R407C Refrigerant Circuit 2 Control Electronic Expansion Valve Model*Qty. HSS 3220*2 3220*1 4221*1 4222*1 3221*2 4221*2 4222*2 3221*1 4222*1 4223*1 4223*2 Motor Power Input kw 216 235 253 270 295 326 356 386 Motor Power Compressor Input (Heating) kw 226 246 265 284 309 342 373 406 Sound Insulation Box Polyurethane Foaming Start star-delta Cooling Liquid Injection Oil RL68H Charge L 2*18 2*16 Crossed Fin and Tube Condenser FPI 14 Face Area m 2 28.16 30.18 32.19 32.19 34.20 36.21 38.22 40.23 Qty. 14 15 16 16 17 18 19 20 Fan Air Flow 104m 3 /h 30.8 33.0 35.2 35.2 37.4 39.6 41.8 44.0 Power Input kw 28.0 30.0 32.0 32.0 34.0 36.0 38.0 40.0 Shell and Tube Water Flow m 3 /h 120 130 139 158 166 178 193 216 Evaporator Water Flow (Heating) m 3 /h 125 136 146 166 174 186 203 227 WPD (kpa) 55 41 53 63 78 74 87 90 Connection inch 8 Heat Recovery Heat exchanger BPHE Length mm 7300 8200 8200 8200 9100 9100 10000 10000 Dimensions Width mm 2260 Height mm 2360 MCS/transport kg 7155 7735 8235 8280 8705 8745 9495 9560 Weight MCS/operation kg 7345 7925 8425 8480 8905 8945 9695 9760 MHS/transport kg 7275 7885 8385 8430 8855 8895 9645 9710 MHS/operation kg 7465 8075 8575 8630 9055 9095 9845 9910 Accessories (Standard) Unit Operation Instruction, Confirmity Certification, Warranty Application Form, Spring Damper, Water Flow Switch Notes: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Nominal cooling capacity is based on the following conditions: 12/7 EWT and LWT,35 ambient temperature; 3. Nominal heating capacity is based on the following conditions: 40/45 EWT and LWT,7/6 ambient DB/WB temperature; 4. Heat recovery conditions are: 50/55 EWT and LWT of hot water, 12/7 EWT and LWT of chiller water. 13

McQuay Single Screw Air Cooled Chiller (R22, SR total heat recovery) MHS F SR 050.1 060.1 070.1 080.1 100.1 120.1 135.1 150.1 170.1 185.1 200.2 220.2 235.2 Cooling kw 170 205 240 280 360 422 455 525 625 654 720 782 840 USRT 48 58 68 80 102 120 129 149 178 186 205 222 239 Heating kw 179 215 252 294 378 443 478 551 656 687 756 821 882 USRT 51 61 72 84 108 126 136 157 187 196 226 246 264 Heat Recovery kw 204 246 288 336 432 506 546 630 750 785 864 938 1008 Panel EG Capacity Adjusting Range 0,25~100% 0,12.5~100% Power Supply V/Ph/Hz 380~400/3/50 R22 Refrigerant Circuit 1 2 Control Electronic Expansion Valve Model*Qty. HSS 3118*1 3120*1 3121*1 3122*1 3220*1 3221*1 4221*1 4222*1 4223*1 4223*1 3220*2 3220*1 3221*1 3221*2 Motor Power Input kw 49 59 69 78 102 120 126 149 182 170 212 222 239 Motor Compressor Power Input kw 50 60 71 81 106 125 131 155 190 178 224 233 251 (Heating) Sound Insulation Optional Polyurethane Foaming Box Start star-delta Cooling Liquid Injection Oil LPT68 Charge L 13 13 13 13 18 18 16 16 16 16 2*18 2*18 2*18 Crossed Fin and Tube Condenser FPI 14 Face Area m 2 9.57 9.57 12.07 12.07 16.09 16.09 16.09 20.12 20.12 24.14 28.16 30.18 32.19 Qty. 4 4 6 6 8 8 8 10 10 12 14 15 16 Fan Air Flow 104m 3 /h 8.8 8.8 13.2 13.2 17.6 17.6 17.6 22.0 22.0 26.4 30.8 33 35.2 Power Input kw 8.0 8.0 12.0 12.0 16.0 16.0 16.0 20.0 20.0 24.0 28.0 30.0 32.0 Shell and Tube Water Flow m 3 /h 29 35 41 48 62 73 78 90 107 112 124 135 144 Evaporator Water Flow (Heating) m 3 /h 31 37 43 51 65 76 82 95 113 118 130 141 152 WPD (kpa) 18 24 18 28 31 37 37 37 32 46 55 41 53 Connection inch 5 8 Heat Recovery Heat exchanger BPHE Length mm 2975 2975 3200 3200 4100 4100 4100 5000 5000 5900 7300 8200 8200 Dimensions Width mm 2260 Height mm 2285 2360 Weight MHS/ transport kg 2745 2755 3320 3340 4630 5070 5070 5830 5830 6400 8245 9035 9710 MHS/ operation kg 2895 2905 3470 3490 4780 5220 5220 6010 6010 6590 8445 9235 9910 Accessories (Standard) Unit Operation Instruction, Confirmity Certification, Warranty Application Form, Spring Damper, Water Flow Switch Notes: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Nominal cooling capacity is based on the following conditions. 3. Nominal heating capacity is based on the following conditions: 40/45 EWT and LWT,7/6 ambient DB/WB temperature. 4. Hear recovery conditions are: 40 /45 EWT and LWT of hot water,12 /7 of chilled water. 14

McQuay Single Screw Air Cooled Chiller (R407C, SR total heat recovery) MHS F SR 050.1 060.1 070.1 080.1 100.1 120.1 135.1 150.1 170.1 185.1 200.2 220.2 235.2 Cooling kw 164 198 232 270 347 407 439 507 603 631 695 755 811 USRT 47 56 66 77 99 116 125 144 172 179 198 215 231 Heating kw 172 208 243 284 365 428 461 532 633 663 730 792 851 USRT 49 59 69 81 104 122 132 152 181 189 223 241 259 Heat Recovery kw 197 237 278 324 417 489 527 608 724 757 834 906 973 Panel EG Capacity Adjusting Range 0,25~100% 0,12.5~100% Power Supply V/Ph/Hz 380~400/3/50 R407C Refrigerant Circuit 1 2 Control Electronic Expansion Valve Model*Qty. HSS 3118*1 3120*1 3121*1 3122*1 3220*1 3221*1 4221*1 4222*1 4223*1 4223*1 3220*2 3220*1 3221*1 3221*2 Motor Power Input kw 49 59 69 78 108 127 133 157 192 180 220 235 253 Motor Compressor Power Input kw 50 60 71 81 112 132 139 164 201 188 230 246 265 (Heating) Sound Insulation Optional Polyurethane Foaming Box Start star-delta Cooling Liquid Injection Oil RL68H Charge L 13 13 13 13 18 18 16 16 16 16 2*18 2*18 2*18 Crossed Fin and Tube Condenser FPI 14 Face Area m 2 9.57 9.57 12.07 12.07 16.09 16.09 16.09 20.12 20.12 24.14 28.16 30.18 32.19 Qty. 4 4 6 6 8 8 8 10 10 12 14 15 16 Air Flow 104m 3 /h 8.8 8.8 13.2 13.2 17.6 17.6 17.6 22.0 22.0 26.4 30.8 33 35.2 Fan Power kw 8.0 8.0 12.0 12.0 16.0 16.0 16.0 20.0 20.0 24.0 28.0 30.0 32.0 Input Shell and Tube Water Flow m 3 /h 28 34 40 46 60 70 76 87 104 109 120 130 139 Evaporator Water Flow (Heating) m 3 /h 30 36 42 49 63 74 79 91 109 114 125 136 146 WPD (kpa) 18 24 18 28 31 37 37 37 32 46 55 41 53 Connection inch 5 8 Heat Recovery Heat exchanger BPHE Length mm 2975 2975 3200 3200 4100 4100 4100 5000 5000 5900 7300 8200 8200 Dimensions Width mm 2260 Height mm 2285 2360 Weight MHS/ transport kg 2745 2755 3320 3340 4630 5070 5070 5830 5830 6400 8245 9035 9710 MHS/ operation kg 2895 2905 3470 3490 4780 5220 5220 6010 6010 6590 8445 9235 9910 Accessories (Standard) Unit Operation Instruction, Confirmity Certification, Warranty Application Form, Spring Damper, Water Flow Switch Notes: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Nominal cooling capacity is based on the following conditions. 3. Nominal heating capacity is based on the following conditions: 40/45 EWT and LWT,7/6 ambient DB/WB temperature. 4. Hear recovery conditions are: 40 /45 EWT and LWT of hot water,12 /7 of chilled water. 15

Operating Limit and Correction Factors Operating Limit Model SR SP Cooling Heating Cooling Heating Max.outside temperature 44 21 44 21 Min. outside temperature without Fan Speed Control 10 10 10 10 with Fan Speed Control -15-15 -15-15 Max. leaving chilled water temperature (water side heat exchanger) 15 50 15 50 Min. leaving chilled water temperature without Glycol 4 35 4 35 (water side heat exchanger) with glycol -8 - -8 - Max. temperature difference of water side exchanger 8 8 8 8 Min. temperature difference of water side exchanger 4 4 4 4 Heat Recovery Side Max. leaving water temperature 50-60 60 Heat Recovery Side Max. water temperature difference Heat Recovery Side Min. water temperature difference 8 8 8 8 4 4 4 4 16

Fouling factors (water side heat exchanger) Fouling factor (m 2 C/kw) Cooling capacity correction Power correction COP correction 0.017 1.045 0.974 1.073 0.044 1.022 0.986 1.037 0.086 1.000 1.000 1.000 0.132 0.980 1.013 0.967 Altitude correction factors Elevation above sea level (m) 0 300 600 900 1200 1500 1800 Barometric pressure (bar) 1.013 0.977 0.942 0.908 0.875 0.843 0.812 Cooling capacity correction factor 1.000 0.993 0.986 0.979 0.973 0.976 0.960 Power input correction factor 1.000 1.005 1.009 1.015 1.021 1.026 1.031 Ethylene glycol correction factors % Of ethylene glycol by weight 10 20 30 40 50 Cooling capacity correction factor 0.991 0.982 0.972 0.961 0.946 Power input correction factor 0.996 0.992 0.986 0.976 0.966 Water flow rate correction factor 1.013 1.04 1.074 1.121 1.178 Water pressure drops correction factor 1.070 1.129 1.181 1.263 1.308 Low temperature operation performance factors Ethylene glycol leaving water temperature of chilled water ( C) 2 0-2 -4-6 -8 Max. ambient temperature ( C) 40 39 38 37 36 35 Cooling capacity correction factor 0.842 0.785 0.725 0.67 0.613 0.562 Power input of compressor correction factor 0.95 0.94 0.92 0.89 0.87 0.84 Min. % of ethylene glycol 10 20 20 30 30 30 17

Dimensions Unit: mm Model 050.1 060.1 070.1 080.1 100.1 120.1 135.1 150.1 170.1 185.1 200.2 220.2 235.2 260.2 285.2 310.2 Depth D 2975 3200 4100 5000 5900 7300 8200 9100 10000 Height H 2385 2460 330.2 350.2 380.2 Model 050.1 060.1 070.1 080.1 100.1 120.1 135.1 150.1 170.1 185.1 200.2 220.2 235.2 260.2 285.2 310.2 Depth D 2975 3200 4100 5000 5900 7300 8200 9100 10000 Height H 2385 2460 330.2 350.2 18

SCHEMATIC DRAWING - HEAT RECOVERY UNIT 19

Literature No.: TM-MHS(F HR)-1101A Supersedes: --- Part No.: M08039110030 2011 McQuay International +1 (800) 432-1342 www.mcquay.com While utmost care is taken in ensuring that all details in the publication are correct at the time of going to press, we are constantly striving for improvement and therefore reserve the right to alter model specifications and equipment without notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market. 21