CENTRIFUGAL CHILLER (GC201210) TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:1400~7200kW SUPER HIGH AMBIENT OPERATION TO 52

Similar documents
Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

MODELS LIST. Nominal Capacity RT

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

3 0 H X C A - H P 2

Call us today! (800)

Water-cooled chillers with High Speed Centrifugal Compressors

Cutting Edge Compressor Technology

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Call us today! (800)

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Modular Air Cooled Scroll Chillers

CVGF. Water Cooled Centrifugal Chillers

Call us today! (800)

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Wired Controller XK60

Water-cooled Centrifugal Chiller

Leadership, Innovation, Advanced Technology Synergise Here!

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

DC inverter Outdoor-air Processing unit (GC )

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

Technical Development Program

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

OIL FREE CENTRIFUGAL CHILLER

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

AQUASNAP JUNIOR 30RHV

DAIKIN Modular Inverter Air Cooled Chiller

30HXC Nominal cooling capacity kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Screw Water Cooled Chiller SCW210

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Scroll Water Cooled Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air Cooled Scroll Chiller / Heat Pump

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions

CASE STUDY AIR-CONDITIONERS

RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

ERACS.C-N Higher efficiency air-cooled screw pump

.2 Section Waste Management and Disposal.

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

MAC-120HE-03 Air-Cooled Chiller

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

30KAV Variable Speed Air-cooled Screw Chiller

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

C&H NORDIC Commercial 4 SERVICE MANUAL

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

MTW Series Modular Oil Free Centrifugal Chillers

Air conditioning 23XRV

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

30RH B Nominal cooling capacity kw Nominal heating capacity kw

CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL

Product Data. Features/Benefits. 19XR,XRT High-Efficiency Hermetic Centrifugal Liquid Chiller 50/60 Hz HFC-134a

ENGINEERED TERMINAL AIR CONDITIONER

Product Data. Features/Benefits. EVERGREEN 19XR,XRV High-Efficiency Hermetic Centrifugal Liquid Chiller 50/60 Hz HFC-134a

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

OACS Outdoor Air-Cooled Central Chillers

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

High COP. Water-Cooled Screw Chiller

Hi-Pres Cooling Products Catalogue. Product Catalogue

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Nirvana. Cycling Refrigerated Dryers

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Rev B, 9/2/2009. Kodiak Chiller Overview

MAC N-407 Air-Cooled Chiller

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

SCA 620C AIR COOLED SCREW CHILLER

TCHE-THHE TCEE

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

Commercial and Technical Data

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

MACH N-407 Heat Pump Air-Cooled Chiller

Air-Cooled Condensing Units with Compact Screw Compressors

Midea VFD Centrifugal Chiller Technology

Commercial Air Conditioners 2017/2018

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Innovation for a Better & Greener Future

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

Transcription:

CENTRIFUGAL CHILLER (GC201210) ER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDIT TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:1400~7200kW SUR HIGH AMBIENT ORATION TO 52 ER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDITIONERS GREE MAKING BETTER CONDIT GREE ELECTRIC APPLIANCES INC.OF ZHUHAI

CONTENTS MODELS LIST...3 NOMENCLATURE...4 CHILLER COMPONENTS...5 ACCESSORIES...6 FEATURES...7 PRODUCT DATA...9 DIMENSION...16 INSTALLATION...18 WIRING DIAGRAMS...20 MICROPROCESSOR CONTROL SYSTEM...25 BMS...34 LONG-DISTANCE MONITORING SYSTEM... 37 2

Digital Multi VRF Technical Sales Guide 1 MODELS LIST Nominal Capacity Model Power Supply Ton Refrigerant Model Name Ph, V, Hz 398 LSBLX1400-M 3,380,50 398 LSBLX1400V-M 3,380,50 398 LSBLX1400-G 3,10000,50 456 LSBLX1600-M 3,380,50 456 LSBLX1600V-M 3,380,50 456 LSBLX1600-G 3,10000,50 511 LSBLX1800-M 3,380,50 511 LSBLX1800V-M 3,380,50 511 LSBLX1800-G 3,10000,50 568 LSBLX2000-M 3,380,50 568 LSBLX2000V-M 3,380,50 568 LSBLX2000-G 3,10000,50 625 LSBLX2200-M 3,380,50 625 LSBLX2200V-M 3,380V,50 625 LSBLX2200-G 3,10000,50 682 LSBLX2400-M 3,380,50 682 LSBLX2400V-M 3,380,50 682 LSBLX2400-G 3,10000,50 740 LSBLX2600-M 3,380V,50 740 LSBLX2600V-M 3,380,50 740 LSBLX2600-G 3,10000,50 796 LSBLX2800-M 3,380,50 796 LSBLX2800V-M 3,380,50 796 LSBLX2800-G 3,10000,50 854 LSBLX3000-M 3,380,50 854 LSBLX3000V-M 3,380,50 R134a 854 LSBLX3000-G 3,10000,50 909 LSBLX3200-M 3,380,50 909 LSBLX3200V-M 3,380,50 909 LSBLX3200-G 3,10000,50 967 LSBLX3400-M 3,380,50 967 LSBLX3400V-M 3,380,50 967 LSBLX3400-G 3,10000,50 1023 LSBLX3600-M 3,380,50 1023 LSBLX3600V-M 3,380,50 1023 LSBLX3600-G 3,10000,50 1081 LSBLX3800-M 3,380,50 1081 LSBLX3800V-M 3,380,50 1081 LSBLX3800-G 3,10000,50 1136 LSBLX4000-M 3,380,50 1136 LSBLX4000V-M 3,380,50 1136 LSBLX4000-G 3,10000,50 1251 LSBLX4400-M 3,380,50 1251 LSBLX4400V-M 3,380,50 1251 LSBLX4400-G 3,10000,50 1364 LSBLX4800-G 3,10000,50 1479 LSBLX5200-G 3,10000,50 1591 LSBLX5600S-G 3,10000,50 1706 LSBLX6000S-G 3,10000,50 1818 LSBLX6400S-G 3,10000,50 1934 LSBLX6800S-G 3,10000,50 2044 LSBLX7200S-G 3,10000,50 Note:1Ton =12000Btu/h = 3.517kW 3

2 NOMENCLATURE LS B LX S V W Motor Voltage and Frequency: G-10000V,50Hz; C-6000V,50Hz;M-380V,50Hz. Variable Frequency: Invariable Frequency-Defaut; V-Variable Frequency. Compressor Class:Single-Detault;S-Two-stage. Nominal Capacity:Number(kW). Compressor Type: LX-Centrifugal Compressor. Compressor Form: B-Semi-hermetic Compressor. Water Chiller Symbol. Example: LSBLX4000-G Centrifugal chiller with the nominal capacity of 4000kW and the motor voltage of 10000V; LSBLX3600V-M Centrifugal chiller with the nominal capacity of 3600kW,the motor voltage of 380V and variable frequency; LSBLX5600S-G Centrifugal chiller with the nominal capacity of 5600kW,the compressor class of Two-stage and the motor voltage of 10000V. 4

Digital Multi VRF Technical Sales Guide 3 CHILLER COMPONENTS FRONT VIEW 1 2 3 4 5 6 7 7 18 8 9 17 16 10 15 14 11 13 12 REAR VIEW 22 23 24 25 26 19 21 20 20 25 27 28 28 14 32 31 30 20 12 29 5

No. Legend 1 Chiller Electric Control Cabinet Assembly 2 Governing Mechanism Assembly 3 Balance Pipe 4 Centrifugal Compressor Assembly 5 Oil Filter 6 Motor 7 Right Water Assembly 8 Cooling Water Outlet 9 Cooling Water Inlet 10 Chilled Water Outlet 11 Chilled Water Inlet 12 Chiller Support Assembly 13 Motor Support Assembly 14 Liquid Reservoir Pipe 15 Evaporator 16 Oil Pump Control Cabinet 17 Oil Heater 18 Oil Level Sight Glasses 19 Condenser 20 Electronic Expansion Valve 21 Oil Pump 22 Oil Cooler 23 Exhaust Pipe Assembly 24 Suction Pipe Assembly 25 Auto Reset Relief Valve 26 Manometer 27 Chiller Identification Nameplate 28 Left Waterbox Assembly 29 Bypass Pipe Assembly 30 Orifice Plate 31 Refrigerant Filter/Drier 32 Refrigerant Purifier 4 ACCESSORIES Name Standard Option REMARK Refrigerant R134a Lube Oil No.68 synthetic fatty oil Oil Filter Low-voltage Startup Cabinet High- voltage Wiring Cabinet Match for the Chiller with the motor voltage of 380V Match for the Chiller with the motor voltage of 6000V and 10000V 6

Digital Multi VRF Technical Sales Guide 5 FEATURES High efficiency and energy efficiency: Today s owners of chilled water plants demand high efficiency and energy efficiency from their chillers. The GREE C centrifugal chillers, equipped with variable frequency drive, maximize chiller efficiency by optimizing compressor operation. Electric power consumption drops dramatically when the motor frequency low. The C chillers deliver industry-leading integrated part-load values (IPLV). The governing mechanism of the chiller use high efficiency ternary impeller and movable diffuser. The new impeller equipped with back sweep long-and-short vane, which ensure the high efficiency at full-load and part-load. The movable diffuser adjusts the area of gas flow passage and maximizes chiller efficiency at part load.new heat-exchanger reduces dramatically heat-exchange resistance when using ultra-high efficiency heat-exchange pipe and increase dramatically the chiller s capacity and the coefficient of performance. Environmental leadership: GREE has long been committed to the environment and its sustainability. The GREE C centrifugal chillers provide our customers with a high-efficiency, chlorine-free long-term solution unaffected by refrigerant phaseouts. The GREE C centrifugal chillers utilize non-ozone depleting HFC-134A refrigerant provides our customers with a safe and environmentally friendly choice without compromising efficiency. Therefore, the effects of potential direct or indirect global warming are greatly diminished. Reliability: The chiller s simple, positive pressure compressor, coupled with new high efficiency heat exchangers, ensures superior reliability and sustainability. The compressor designed by America Concepts NREC-constructed pro-fessional software and checked the oscillation and critical speed by Ansys and DyRoBeS software. GREE s semi-hermetic motors operate in a clean-liquid, refrigerant-cooled environment. The semi-hermetic design eliminates the potential for shaft seal leaks and refrigerant/oil loss. These are just some of the reasons why the chillers have the industry s lowest leak rate. High-strength aluminium alloy-constructed impeller has high strength and preferable corrosion resistance. The impeller is tested to ensure proper operation, including profile test, dynamic balance running and over-speed test and so on. Positive Pressure design: The chiller s positive pressure design reduces dramatically the chiller size compared to lowpressure designs. The smaller size minimizes the need for valuable mechanical room floor space. In addition, positive pressure designs eliminate the need for costly low-pressure containment devices, reducing the initial cost of the system. Optional unit-mounted starter: Available in low-voltage wye-delta and solid state, the chiller s unit-mounted starter provides a single point power connection, reducing chiller installation time and expense. Compressor features: The chillers with the capacity less than 5200kW are designed for single-stage compressor and 7

the chillers with the capacity more than 5200kW are designed for two-stage compressor. This design increases product reliability by eliminating the additional moving parts associated with multiple stage chillers, such as additional guide vanes and complex economizers. Capacity regulating device is composed of Inlet Guide Vane (IGV), high efficiency ternary impeller and movable diffuser, and orifice plate and electronic expansion valve, that can achieve capacity step-less regulation at 0~100% load and matches for actual load.the motors are hermetically sealed from the machine room, cooling is accomplished by spraying liquid refrigerant on the motor windings. This highly efficient motor cooling method results in the use of smaller, cooler-running motors than could be realized with air-cooled designs of the same type. Thus, hermetic motors require less inrush current and are smaller and lighter than comparable air-cooled motors. Heat exchangers feature: New heat-exchanger specially design for centrifugal chiller uniform the distribution of refrigerant and rationaliz-ation the temperature field, thus increase heat-exchange efficiency. The new heat-exchanger reduces dramatically heat-exchange resistance when using ultrahigh efficiency heat-exchanger pipe and increase dramatically the chiller s capacity and the coefficient of performance. The condenser baffle prevents direct impingement of high velocity compressor gas onto the condenser tubes. The baffle eliminates the related vibration and wears of the tubes and distributes the refrigerant flow evenly over the length of the vessel for improved efficiency. Advanced control system: The advanced control system provides unparalleled ease of operation and full automatic running of the chiller. The LCD(liquid crystal display) display chiller s operating, status and diagnostic messages for improved user interface. Modular pull-out/plug-in design, reducing wiring requirements and providing easy installation, and low-voltage design, providing the ultimate assurance of personal safety and control integrity. 8

Digital Multi VRF Technical Sales Guide 6 PRODUCT DATA 6.1 Performance Parameter Singler-stage Model Cooling capacity LSBLX1400-M LSBLX1600-M LSBLX1800-M LSBLX2000-M LSBLX1400-G LSBLX1600-G LSBLX1800-G LSBLX2000-G kw 1400 1600 1800 2000 RT 398 456 511 562 Capacity adjustment range % 10-100 10-100 10-100 10-100 Power supply Comperssor EER W/W 5.53 5.46 5.61 5.65 IPLV W/W 6.10 6.21 6.38 6.43 -M Ph,V,Hz 3Ph,380V,50Hz -G Ph,V,Hz 3Ph,10000V,50Hz Power input kw 261 293 321 354 -M A 450.6 505.9 554.2 611.2 -G A 17.1 19.2 21.1 23.2 Type - Semi-hermetic Centrifugal Compressor Starting mode - star-delta Quantity - 1 Refrigerant charge volume kg 330 360 600 625 Refrigeration oil Evaporator Condenser Type - No.68 synthetic fatty oil Charge volume L 50 50 60 60 Type - Flooded Shell and Tube Fouling factor m2 /W 0.018 0.018 0.018 0.018 Water flow volume Pressure drop L/s 66.9 76.4 86.1 95.6 GPM 1061 1211 1365 1514 kpa 75 75 75 75 ft.wg 25.1 25.1 25.1 25.1 Connection pipe mm 200 200 250 250 Type - Shell and Tube Fouling factor m2 /W 0.044 0.044 0.044 0.044 Water flow volume Pressure drop L/s 83.6 95.6 107.5 119.4 GPM 1325 1514 1704 1893 kpa 70 70 70 70 ft.wg 23.4 23.4 23.4 23.4 Connection pipe mm 200 200 250 250 Sound pressure level db(a) 88 88 88 90 Dimension Outline(WxDxH) mm 3630 1680 2060 3630 1680 2060 4150 1900 2250 4150 1900 2250 Package(WxDxH) mm 3700 1750 2130 3700 1750 2130 4200 1970 2410 4200 1970 2410 Net/Gross/Operting Weight kg 6300/6500/6800 6600/6800/7100 8800/9000/9800 9200/9400/10200 Loading quantity 40'GP/40'HQ set 0/2 0/2 0/2 0/2 9

Model Cooling capacity LSBLX2200-M LSBLX2400-M LSBLX2600-M LSBLX2800-M LSBLX2200-G LSBLX2400-G LSBLX2600-G LSBLX2800-G kw 2200 2400 2600 2800 RT 625 682 740 796 Capacity adjustment range % 10-100 10-100 10-100 10-100 Power supply Comperssor EER W/W 5.74 5.74 5.80 5.83 IPLV W/W 6.54 6.53 6.6 6.64 -M Ph,V,Hz 3Ph,380V,50Hz -G Ph,V,Hz 3Ph,10000V,50Hz Power input kw 383 418 448 480 -M A 661.3 721.7 773.5 828.8 -G A 25.1 27.4 29.4 31.5 Type - Semi-hermetic Centrifugal Compressor Starting mode - star-delta Quantity - 1 Refrigerant charge volume kg 650 700 725 750 Refrigeration oil Evaporator Condenser Type - No.68 synthetic fatty oil Charge volume L 60 80 80 80 Type - Flooded Shell and Tube Fouling factor m2 /W 0.018 0.018 0.018 0.018 Water flow volume Pressure drop L/s 105.0 114.7 124.2 133.9 GPM 1664 1818 1968 2122 kpa 75 90 90 90 ft.wg 25.1 30.1 30.1 30.1 Connection pipe mm 250 250 250 250 Type - Shell and Tube Fouling factor m2 /W 0.044 0.044 0.044 0.044 Water flow volume Pressure drop L/s 131.4 143.3 155.3 167.2 GPM 2082 2272 2461 2650 kpa 70 85 85 85 ft.wg 23.4 28.5 28.5 28.5 Connection pipe mm 250 250 250 250 Sound pressure level db(a) 90 90 90 90 Dimension Outline(WxDxH) mm 4150 1900 2250 4350 2070 2500 4350 2070 2500 4350 2070 2500 Package(WxDxH) mm 4200 1970 2410 4650 2110 2660 4650 2110 2660 4650 2110 2660 Net/Gross/Operting Weight kg 9400/9600/10600 10800/11000/12800 11200/11400/13000 11600/11800/13200 Loading 40'GP/40'HQ set 0/2 0/0 0/0 0/0 quantity 10

Digital Multi VRF Technical Sales Guide Model Cooling capacity LSBLX3000-M LSBLX3200-M LSBLX3400-M LSBLX3600-M LSBLX3000-G LSBLX3200-G LSBLX3400-G LSBLX3600-G kw 3000 3200 3400 3600 RT 854 909 967 1023 Capacity adjustment range % 10-100 10-100 10-100 10-100 Power supply Comperssor EER W/W 5.74 5.78 5.84 5.70 IPLV W/W 6.53 6.57 6.65 6.48 -M Ph,V,Hz 3Ph,380V,50Hz -G Ph,V,Hz 3Ph,10000V,50Hz Power input kw 523 554 582 632 -M A 903.0 956.5 1004.9 1091.2 -G A 34.3 36.3 38.2 41.5 Type - Semi-hermetic Centrifugal Compressor Starting mode - star-delta Quantity - 1 Refrigerant charge volume kg 775 800 825 900 Refrigeration oil Evaporator Condenser Type - No.68 synthetic fatty oil Charge volume L 80 80 80 100 Type - Flooded Shell and Tube Fouling factor m2 /W 0.018 0.018 0.018 0.018 Water flow volume Pressure drop L/s 143.3 152.8 162.5 171.9 GPM 2272 2421 2575 2725 kpa 90 90 90 115 ft.wg 30.1 30.1 30.1 38.5 Connection pipe mm 300 300 300 300 Type - Shell and Tube Shell and Tube Shell and Tube Shell and Tube Fouling factor m2 /W 0.044 0.044 0.044 0.044 Water flow volume Pressure drop L/s 179.2 191.1 203.1 215.0 GPM 2839 3029 3218 3407 kpa 85 85 85 100 ft.wg 28.5 28.5 28.5 33.5 Connection pipe mm 300 300 300 350 Sound pressure level db(a) 90 92 92 92 Dimension Outline(WxDxH) mm 4530 2070 2500 4530 2120 2500 4530 2120 2500 4750 2330 2750 Package(WxDxH) mm 4650 2160 2660 4650 2160 2660 4650 2160 2660 5000 2340 2910 Net/Gross/Operting Weight kg 11800/12000/13500 12000/12200/14000 12200/12400/14500 14600/14800/16500 Loading quantity 40'GP/40'HQ set 0/0 0/0 0/0 0/0 11

Model LSBLX3800-M LSBLX4000-M LSBLX4400-M LSBLX3800-G LSBLX4000-G LSBLX4400-G LSBLX4800-G LSBLX5200-G Cooling capacity kw 3800 4000 4200 4800 5200 RT 1081 1136 1251 1364 1479 Capacity adjustment range % 10-100 10-100 10-100 10-100 10-100 EER W/W 5.74 5.81 5.50 5.82 5.91 IPLV W/W 6.53 6.62 6.55 6.62 6.72 Power supply -M Ph,V,Hz 3Ph,380V,50Hz -G Ph,V,Hz 3Ph,10000V,50Hz Power input kw 662 688 764 825 880 -M A 1143.0 1187.9 1319.1 -G A 43.4 45.1 50.1 54.1 57.7 Type - Semi-hermetic Centrifugal Compressor Comperssor Starting mode - star-delta Quantity - 1 Refrigerant charge volume kg 925 950 1000 1050 1100 Refrigeration oil Evaporator Condenser Type - No.68 synthetic fatty oil Charge volume L 100 100 100 100 100 Type - Flooded Shell and Flooded Shell and Flooded Shell and Flooded Shell and Flooded Shell and Tube Tube Tube Tube Tube Fouling factor m2 /W 0.018 0.018 0.018 0.018 0.018 Water flow L/s 181.7 191.1 210.3 229 248.3 volume GPM 2879 3029 3332 3636.203557 3936 Pressure drop kpa 115 115 115 115 115 ft.wg 38.5 38.5 38.5 38.5 38.5 Connection pipe mm 300 300 350 350 350 Type - Shell and Tube Fouling factor m2 /W 0.044 0.044 0.044 0.044 0.044 Water flow L/s 226.9 238.9 262.8 287 310.6 volume GPM 3597 3786 4164 4543.053354 4922 Pressure drop kpa 100 100 105 105 105 ft.wg 33.5 33.5 35.2 35.2 35.2 Connection pipe mm 350 350 350 350 350 Sound pressure level db(a) 92 92 92 95 95 Outline(WxDxH) mm 4750 2330 2750 4750 2330 2750 4750 2480 2750 4750 2480 2750 4750 2480 2750 Dimension Package(WxDxH) mm 5000 2340 2910 5000 2340 2910 5000 2490 2910 5000 2490 2910 5000 2490 2910 Net/Gross/Operting Weight kg 14800/15000/17000 15200/15400/17500 15800/16000/18000 16200/16400/18500 16600/16800/19000 Loading 40'GP/40'HQ set 0/0 0/0 0/0 0/0 0/0 quantity 12

Digital Multi VRF Technical Sales Guide Tow-stage Model LSBLX5600S-G LSBLX6000S-G LSBLX6400S-G LSBLX6800S-G LSBLX7200S-G Cooling capacity kw 5600 6000 6400 6800 7200 RT 1591 1706 1818 1934 2044 Capacity adjustment range % 10-100 EER W/W 5.89 5.94 5.97 5.98 6.03 IPLV W/W 6.71 6.76 6.79 6.80 6.86 Power supply Ph,V,Hz 3Ph,10000V,50Hz Power input kw 950 1010 1072 1138 1195 /LRA A 62.3 66.3 70.3 74.7 78.4 Type - Semi-hermetic Centrifugal Compressor Comperssor Starting mode - direct start Quantity - 1 1 1 1 1 Refrigerant charge volume kg 1500 1600 1700 1800 1900 Type No.68 synthetic fatty oil Refrigeration Charge oil L 125 125 125 125 125 volume Type - Flooded Shell and Tube Fouling factor m2 /W 0.018 0.018 0.018 0.018 0.018 Water flow L/s 267.5 286.7 305.8 325.0 343.9 volume GPM 4239.3 4543.6 4846.3 5150.6 5450.1 Evaporator kpa 125 125 125 125 125 Pressure drop ft.wg 41.0 41.0 41.0 41.0 41.0 Connection pipe mm 350 350 400 400 400 Type - Shell and Tube Fouling factor m2 /W 0.044 0.044 0.044 0.044 0.044 Water flow L/s 334.4 358.3 382.2 406.1 430.0 volume GPM 5299.5 5678.3 6057.1 6435.8 6814.6 Condenser kpa 125 125 125 125 125 Pressure drop ft.wg 41.0 41.0 41.0 41.0 41.0 Connection pipe mm 400 400 450 450 450 Sound pressure level db(a) 95 95 95 95 95 Dimension Outline(WxDxH) mm 5350 2620 3100 5350 2620 3100 5350 2820 3100 5350 2820 3100 5350 2820 3100 Package(WxDxH) mm 5800 2630 3260 5800 2630 3260 5800 2830 3260 5800 2830 3260 5800 2830 3260 Net/Gross/Operting Weight Loading 40'GP/40'HQ set 0/0 0/0 0/0 0/0 0/0 quantity kg 22500/22700/25950 23800/24000/27500 25500/25700/29450 26100/26300/30200 26500/26700/31000 Note: 1.The performance stated above is measured under following conditions: Inlet/Outlet chilled water temperature: 12/7 (53.6/44.6 ); Inlet/Outlet cooling water temperature: 30/35 (86.4/95.4 ). 2.The product data is standard by the data in identification nameplate. If has other special request, please don t hesitate to contact with us. 13

6.2 Performance Correction 1.40 1.35 1.30 1.25 ( ) 20(68) 25(77) 30(86) Correotion Value of Cooling Capacity 1.20 1.15 1.10 1.05 1.00 0.95 0.90 0.85 35(95) Inlet Cooling Water Temperature 0.80 5678 91 01 11 21 3 (41) (43) (45) (46) (48) (50) (52) (54) (55) ( ) Outlet Chilled Water Temperature Note: 1. Actual Cooling Capacity=Nominal Cooling Capacity Correction Value (Here: Nominal Cooling Capacity is looked up in the table of performance parameter and Correction Value is looked up in curve diagram above). 2. The cooling capacity increases with the increase of outlet chilled water temperature and decreases with the decrease of outlet cooling water temperature. 14

Digital Multi VRF Technical Sales Guide 6.3 Electrical Data Motor Model YSR308-2-R134a(380V) YSR352-2-R134a(380V) YSR383-2-R134a(380V) YSR452-2-R134a(380V) YSR520-2-R134a(380V) YSR590-2-R134a(380V) YSR665-2-R134a(380V) YSR750-2-R134a(380V) YSR905-2-R134a(380V) Motor Characteristic LRYA LRYA LRYA LRYA LRYA LRYA LRYA LRYA LRYA Electrical Data (380V) Max. Power Input(kW) Current(A) 615 360 1398 3916 703 412 1598 4475 765 448 1739 4869 903 529 2052 5746 1039 609 2361 6611 1179 690 2679 7501 1329 778 3019 8454 1498 878 3405 9535 1808 1059 4109 11505 Motor Model Motor Characteristic YSR308-2-R134a(10kV) YSR352-2-R134a(10kV) YSR383-2-R134a(10kV) YSR452-2-R134a(10kV) YSR520-2-R134a(10kV) YSR590-2-R134a(10kV) YSR665-2-R134a(10kV) YSR750-2-R134a(10kV) YSR905-2-R134a(10kV) YSR995-2-R134a(10kV) YSR1110-2-R134a(10kV) YSR1250-2-R134a(10kV) Legend: : RATED LOAD AMPS LRYA: LOCKED ROTOR AMPS for Y start : LOCKED ROTOR AMPS for Δ start Max. Power Input(kW) 360 412 448 529 609 690 778 878 1059 1164 1299 1463 Electrical Data (380V) Current(A) 23.4 148.8 26.7 170 29.1 185 34.3 218.4 39.5 251.2 44.8 285 50.5 321.3 56.9 362.3 68.7 437.2 75.5 480.7 84.3 536.2 94.9 603.9 15

7 DIMENSION 7.1 Dimension-Units RECOMMENDED OVERHEAD SE RVICE CLEARANCE: 1500 mm D E C F A B Model Length A(mm) Width B(mm) Height C(mm) Length for Tube DrawingD(mm) Length for Motor Service Clearance E(mm) Length for Chiller Side Service Clearance F(mm) LSBLX1400(V)-M(G) 4150 1730 2150 3500 1500 1220 LSBLX1600(V)-M(G) 4150 1730 2150 3500 1500 1220 LSBLX1800(V)-M(G) 4150 1900 2250 3500 1500 1220 LSBLX2000(V)-M(G) 4150 1900 2250 3500 1500 1220 LSBLX2200(V)-M(G) 4150 1900 2250 3500 1500 1220 LSBLX2400(V)-M(G) 4530 2070 2500 3800 1650 1320 LSBLX2600(V)-M(G) 4530 2070 2500 3800 1650 1320 LSBLX2800(V)-M(G) 4530 2070 2500 3800 1650 1320 LSBLX3000(V)-M(G) 4530 2120 2500 3800 1650 1320 LSBLX3200(V)-M(G) 4530 2120 2500 3800 1650 1320 LSBLX3400(V)-M(G) 4530 2120 2500 3800 1650 1320 LSBLX3600(V)-M(G) 4750 2330 2750 4000 1800 1320 LSBLX3800(V)-M(G) 4750 2330 2750 4000 1800 1320 LSBLX4000(V)-M(G) 4750 2330 2750 4000 1800 1320 LSBLX4400(V)-M(G) 4750 2380 2750 4000 1800 1320 LSBLX4800-G 4750 2380 2750 4000 1800 1320 LSBLX5200-G 4750 2380 2750 4000 1800 1320 LSBLX5600S-G 5350 2620 3100 4400 1800 1520 LSBLX6000S-G 5350 2620 3100 4400 1800 1520 LSBLX6400S-G 5350 2820 3100 4400 1800 1520 LSBLX6800S-G 5350 2820 3100 4400 1800 1520 LSBLX7200S-G 5350 2820 3100 4400 1800 1520 LSBLX7800S-G 16

Digital Multi VRF Technical Sales Guide 7.1 Dimension-Units CONDENSER EVAPORATOR A E B C D F DRIVE END: Cooler Waterboxes: Inlet; Outlet Condenser Waterboxes: Inlet; Outlet Model Length A(mm) Width B(mm) Height C(mm) Length for Tube DrawingD(mm) Length for Motor Service Clearance E(mm) Length for Chiller Side Service Clearance F(mm) LSBLX1400(V)-M(G) 4150 1730 2150 3500 1500 1220 LSBLX1600(V)-M(G) 4150 1730 2150 3500 1500 1220 LSBLX1800(V)-M(G) 4150 1900 2250 3500 1500 1220 LSBLX2000(V)-M(G) 4150 1900 2250 3500 1500 1220 LSBLX2200(V)-M(G) 4150 1900 2250 3500 1500 1220 LSBLX2400(V)-M(G) 4530 2070 2500 3800 1650 1320 LSBLX2600(V)-M(G) 4530 2070 2500 3800 1650 1320 LSBLX2800(V)-M(G) 4530 2070 2500 3800 1650 1320 LSBLX3000(V)-M(G) 4530 2120 2500 3800 1650 1320 LSBLX3200(V)-M(G) 4530 2120 2500 3800 1650 1320 LSBLX3400(V)-M(G) 4530 2120 2500 3800 1650 1320 LSBLX3600(V)-M(G) 4750 2330 2750 4000 1800 1320 LSBLX3800(V)-M(G) 4750 2330 2750 4000 1800 1320 LSBLX4000(V)-M(G) 4750 2330 2750 4000 1800 1320 LSBLX4400(V)-M(G) 4750 2380 2750 4000 1800 1320 LSBLX4800-G 4750 2380 2750 4000 1800 1320 LSBLX5200-G 4750 2380 2750 4000 1800 1320 LSBLX5600S-G 5350 2620 3100 4400 1800 1520 LSBLX6000S-G 5350 2620 3100 4400 1800 1520 LSBLX6400S-G 5350 2820 3100 4400 1800 1520 LSBLX6800S-G 5350 2820 3100 4400 1800 1520 LSBLX7200S-G 5350 2820 3100 4400 1800 1520 LSBLX7800S-G Note: 1. The product data is standard by the data in identification nameplate. If has other special request, please don't hesitate to contact with us. 2. The dimensional data-nozzle above is base on the inlet/outlet on drive end and we also provide the products with the inlet/outlet on compressor end. If need, please don't hesitate to contact with us. 17

8 INSTALLATION 8.1 Request for Wiring and Tube Layout The general requests for wiring and tube layout as follow: 1. Certified field wiring and dimensional diagrams are available on request. 2. All wiring and tube layout must be installed perfectly and comply with applicable codes. 3. Electric cable must according to national electric standard, and the electric cable must be insulated. 4. All wiring connect should be reliable and shouldn' t loose and pull-off connect. 5. Nozzle connect should be burnished flat and smooth, and pipeline should clear and have no fouling products. 6. Filter screen must be installed in pipeline of chilled water and cooling water. 7. To prevent the water washing and eroding the heat-exchange tube, flow governor valve must be installed in outlet. 8. It should install temperature and pressure transducer in inlet/outlet chilled and cooling water. 9. The tubing of chilled and cooling water should support by support to prevent adding the load to evaporator and condenser. 8.2 Machine Footprint Soleplate Steel Base Plate (User Supplied) A 300 500 Center Line (Condenser) A F 300 70 Center Line (Evaporator) 125 250 E Model E F Model E F LSBLX1000(H)(V)G 2790 1430 LSBLX3600(H)(V)G 3790 2080 LSBLX1200(H)(V)G 2790 1430 LSBLX3800(H)(V)G 3790 2080 LSBLX1400(H)(V)G 2790 1430 LSBLX4000(H)(V)G 3790 2080 LSBLX1600(H)(V)G 2790 1430 LSBLX4400(H)(V)G 3790 2230 LSBLX1800(H)(V)G 3290 1650 LSBLX4800HG 3790 2230 LSBLX2000(H)(V)G 3290 1650 LSBLX5200HG 3790 2230 LSBLX2200(H)(V)G 3290 1650 LSBLX5600SHG 4190 2370 LSBLX2400(H)(V)G 3590 1820 LSBLX6000SHG 4190 2370 LSBLX2600(H)(V)G 3590 1820 LSBLX6400SHG 4190 2570 LSBLX2800(H)(V)G 3590 1820 LSBLX6800SHG 4190 2570 LSBLX3000(H)(V)G 3590 1870 LSBLX7200SHG 4190 2570 LSBLX3200(H)(V)G 3590 1870 LSBLX7800SHG 4590 2570 LSBLX3400(H)(V)G 3590 1870 18

Digital Multi VRF Technical Sales Guide To prevent eroding of chiller footing, request good drainage around the chiller and flat and smooth footprint,the specific requests as follow: 1.The maximal difference in height (degree of level) among the footprints should less than 3mm; 2.To service and clear easily, the height of footprint should higher 100mm than ground; 3.Should set discharge ditch around the chiller; 4.It must have no gaps between accessory soleplate and chiller s soleplate. 5.It must do second grout filling fix around accessory soleplate and adjusting shim. 8.3 Isolation Style of Machine Footprint A-A Anchor Bolt (User Supplied) Screw M30 (User Supplied) Washer (User Supplied) ground Grouting Height500 >100 250 45 350 200X200 Soleplate Rubber Plate 15mm Thick Steel Base Plate 20mm Thick (User Supplied) Grouting Note: 1. Dimensions in figure are in millimeters. 2. It should stuff adjusting shim between accessory soleplate and footprint. 3. Sling the chiller and lay the isolation rubber seat retainer on the soleplate, then lay the chiller on the rubber seat retainer rightly. 4. Do grout filling fix after perching the chiller on footprint rightly and the grouting height is 500mm. 19

9 WIRING DIAGRAMS Control cabinet wiring (380V) W61 YEGN POWER N XT1 L1 W127 YEGN W161 W160 W52 YEGN XT5 2 1 QF1 W162 YV4 W163 W164 YV3 W165 W167 W168 YV2 W169 W170 YV1 W174 W171 N1 W172 W173 W2 W3 W4 W5 W6 W7 W8 W138 W101 W9 XT N2 N3 N4 N5 N6 N7 N8 66 14 W14 W15 W16 W17 W18 W19 W20 W21 W22 L1 a b c d e f FUSE XT4-L1 XT4-N1 W50 W51 M4 W1 OUT TCv XT4-N7 XT4-f 65 66 W121 W122 M3 IN OUT W64 W65 g W139 65 1 XT3 2 XT3 W107 W109 3 XT3 4 XT3 19 21 W134 W136 W137 39 W28 W29 W30 W31 W32 W33 W34 W35 23 25 27 29 31 33 35 37 W36 W110 W112 W114 W116 W118 W40 XT3 5 PTC XT3 8 FS FR PM2 PTC W113 SB XT3 6 28 XT3 7 W111 W38 W119 26 34 W37 11 SU1 SU2 W39 W41 10 8 KA2 FR2 W115 W117 startup cabinet PM1 malfunction 16 18 20 22 40 24 9 12 30 32 36 38 W24 W25 W26 W27 W135 W75 W76 W42 W43 W44 W45 W46 W47 W48 W49 X43 X42 X39 X38 X40 X50 X19 X22 X24 X23 X28 X27 X26 IN GND 63 X2 X3 X4 X66 BU W131 BU W132 BU W133 BU W102 BU SP3 SP4 Ormon mid.relay TCv TCi DC POWER AP2 XT5 W146 W147 W144 W145 W148 W149 W150 W151 W140 W141 W142 BN BU BN SP1 SP2 W143 BU W152 W153 W154 W155 W156 W157 W158 W159 W166 YEGN W125 4344 W59 IN W60 SB W66 W67 XT4-c XT4-N4 Door of the cabinet XT installation board X35 X20 AC-L X21 AC-N X55 K4 X67 W58 44 1 Controlling circuit to the startup cabinet CN1 TC X16 AP1 FUSE:50T 3.15A 250V~ Control box Current in the startup cabinet sampling 1 5 6 XT 2 3 XT4-d XT4-N5 64 1 2 3 4 5 6 7 8 9 1011121314 13 Startup Cabinet 1 2 3 4 5 6 7 8 9 1011121314 XT4 AP1 QF1 thermal switch in COMP Cooling fan 1 2 TC TCt XT XT XT X18 X6 XT4-a XT4-N2 L N W62 W63 DC POWER2 V- V+ W128 W129 XT4-e XT4-N6 AP2 XT4 W53 W54 W79 YEGN W120 YEGN W123 W124 4142 W55 W56 XT4-b XT4-N3 W77 W78 L N V- DC POWER1 V+ W126 W57 W68 W69 W70 W80 W23 W90 W91 W92 W93 W94 W95 W96 W97 W98 4546 4950 5152 5354 55565758 5960 TCt 4748 W10 W11 W12 15 17 W106 W108 ST2 W13 W73 W74 W71 W72 W81 W82 W83 W84 W85 W86 W87 W88 W89 W99 W130 W100 W103 W104 W105 - + Tangibly screen X37 ST1 4 KM3 KM4 ST4 ST5 ST6 ST7 ST8 5 6 TCi X31 X32 X34 X33 X1 4 6162 ST9 7 SA Breaker of 2 poles NAME Display Dirgram DC12V 2 3 KM1 KM2 X14 X13 X11 X12 X8 Controlling mainboard SYMBOL 20

42 Digital Multi VRF Technical Sales Guide Control cabinet wiring (10000V) POWER N W161 W138 W1 XT4 W2 W3 W4 W5 W6 W7 W8 W9 XT N1 N2 N3 N4 N5 N6 N7 N8 13 1 Controlling circuit to QF1 the startup cabinet W14 W15 W16 W17 W18 W19 W20 W21 W22 XT L1 L1 a b c d e f g 14 4 W160 FUSE W139 W23 XT4-L1 XT4-N1 14 13 W50 W51 W120 W121 W122 TC W127 M4 M3 IN OUT W123 W124 W125 W126 W52 4142 4344 XT5 2 W55 W56 XT4-e W53 CN1 X16 OUT W57 W174 XT4-N6 W54 1 XT4-N7 XT4-f TCv W59 W171 W172 W173 IN W60 W162 YV4 W163 SB W37 W38 W66 N7 KM 2 W67 X37 W164 YV3 W165 W130 W131 AP2 9 10 3 W68 X35 W167 W168 W69 YV2 W132 W133 11 12 XT4-c X20 W169 YV1 W170 XT4-N4 W70 X21 X55 W64 W10 W11 W12 15 17 W106 W108 1 KM1 X43 XT3 2 XT3 W107 W109 3 XT3 KM2 4 XT3 19 KM3 W13 16 18 20 W24 W25 W26 W27 21 KM4 22 W134 W136 W137 W135 Current in the startup cabinet sampling 39 YV5 40 5 1 6 W73 W74 2 3 TCi 5 6 4 W71 W72 W75 W76 XT4-d XT4-N5 X42 X39 X38 X40 X50 X19 X22 X24 IN GND W28 W29 W30 W31 W32 W33 W34 W35 23 25 27 29 31 33 35 37 W36 W110 W112 W114 W116 W118 W40 XT3 5 PTC1 XT3 8 PM2 FS-61 FR PTC2 SB XT3 7 FS-62 W119 34 SU1 SU2 W39 W41 XT3 6 8 startup PM1 W111 W113 W115 W117 cabinet malfunction 24 26 28 30 32 7 36 38 W42 W43 W44 W45 W46 W47 W48 W49 SA X23 X28 X27 X26 DC12V AP1 FUSE:50T 3.15A 250V~ W61 - XT4-b XT4-N3 W77 W78 L N V- DC POWER1 V+ W65 K4 X31 X32 X34 X33 X1 W90 W91 W92 W93 W94 W95 W96 W97 W98 4546 4950 5152 5354 5556 5758 5960 6162 TCt ST1 ST4 ST5 ST6 ST7ST8 ST9 ST2 Control box XT 5 6 7 8 9 101112 63 SP1 X2 SP2 W142 X3 W101 W102 64 65 66 SP3 X4 W144 W145 SP4 6 5 4 3 1 2 3 4 TCv TCi DC 5 6 7 8 POWER 7 8 1 2 AP2 W146 W147 W148 W149 W150 W151 W152 W153 W154 W155 W156 W157 W158 W159 X18 X6 Mainboard XT4-a XT4-N2 L N W62 W63 V- V+ DC POWER2 W128 W129 W79 W80 W58 X67 44 X14 X13 X11 X12 X8 W81 W82 W83 W84 W85 W86 W87 W88 W89 W103 W104 W105 + Tangibly screen W166 Door of the cabinet installation board 4748 W99 W140 W100 W141 W175 W176 W177 BN BU BN W178 BU W143 Startup Cabinet 5 6 7 8 9 101112 SYMBOL FUSE XT4 AP1 QF1 KM Ormon mid.relay Cooling fan Breaker of 2 poles NAME 1 2 XT2 TC TCt XT XT XT 21

Power cabinet wiring: POWER W1 L1 L2 L3 N XT1 FS E KM1 XT2 Oil pump W2 W3 WT3 7 W221 1 W12 L1 W11 L2 W10 L3 W23 L4 8 22 6 W27W 24 W13W 18 13 13 5 W4 W5 W6 13 5 24 6 W7 W8 W9 L1 L2 L3 W36 W37 W38 U V M2 W W28 HL1 HL2 W19 E W25 HL3 W26 QF2 24 W14 1 KM2 26 W16 W29 5 A B W15 XT2 W20 W21 U W Oil heater W17 XT3 W39 W30 E E 1 Door of the cabinet XT3 W31 Control cabinet XT PM2 2 W32 3 FS QF2K M1 KM2 PM2 XT1 KM2 W33 4 XT2 W34 5 XT3 FS W35 Oil pump Oil heater Oil pump controlling controlling overload Note:the wire connection between power and control cabinet shows below. stand for the sequences in the terminal board, power cabinet. 1 2 3 4 5 L1 13 15 16 17 18 25 26 34 33 QF1 6 7 8 N 6 E E 22

Digital Multi VRF Technical Sales Guide Typical wiring (10kV) Startup Cabinet Centrifugal Chiller Main Power Cable from the Local Distribution Box Note: Wire 1 :Main power cable. Wire :Power Cable between Freestanding Compressor Motor Starter and Compressor Motor. Wire 3 :Power Cable between Low Voltage Power (380V 3N~) and Power Box. Wire 4 :Signal Cable between Freestanding Compressor Motor Starter and Control Box. Wire 5 :Signal Cable between Control Box and other equipment (Pump. Fan ) Main Power Freestanding Compressor Motor Starter Chilled Pump Contactor(220V~) Cooling Pump/Fan Contactor(220V~) Remote Switch Low Voltage Power 380V 3N~ Compressor Motor Control Box Power Box 23

Typical wiring(380v) Startup Cabinet Centrifugal Chiller Main Power Cable from the Local Distribution Box Note: Wire 1 :Main power cable. Wire :Power Cable between Freestanding Compressor Motor Starter and Compressor Motor. Wire 3 :Power Cable between Low Voltage Power (380V 3N~) and Power Box. Wire 4 :Signal Cable between Freestanding Compressor Motor Starter and Control Box. Wire 5 :Signal Cable between Control Box and other equipment (Pump. Fan ) Main Power Startup Cabinet Chilled Pump Contactor(220V~) Cooling Pump/Fan Contactor(220V~) Remote Switch M Compressor Motor Oil Pump Cabinet Control Cabinet 24

Digital Multi VRF Technical Sales Guide 10 MICROPROCESSOR CONTROL SYSTEM 10.1 General Control Design The chiller is allowed to be turned on only after the controller detects that all input signals goes normal: the start/stop of the compressor and the position of the preroation vane are dependent on the leaving chilled temperature and amperage of the motor; if anti-freezing measures should be taken for the evaporator is dependent on the leaving water temperature and the evaporating pressure; if the cooling water in the condenser is overheated is controlled by the condensing pressure; the opening angle of the electronic expansion valve automatically varies as the change of the temperature of the motor winding; the oil temperature is controlled and adjusted also by the electronic expansion valve; the compressor can be restarted only after it has turned off for at least 20 minutes; the oil heater acts depending on the oil sump temperature. 10.2 Controller 10.2.1 Outline Drawing of the Touch Screen 1 2 3 4 Fig.1 Outline 1.Power LED (PWR): Yellow; when the touch screen is powered on, the LED lights up. 2.CPU LED (CPU): Green; when the touch screen is working normally, the LED lights up. 3.Communication LED (COM): Red; when the touch screen is communicating with other devices, the LED blinks. 4.LCD: Touch Screen and Color Liquid Crystal Display 25

10.3 Basic Screens and Operations 10.3.1 Menu Bar Fig.2 Menu Bar Menu bar is on the bottom of the screen and the function of each touch button is described below: 1). CURVE : Touch it to enter the CURVE screen to review the current and history curves of pressure, temp, etc. 2). EVENT : Touch it to enter the EVENT screen to review the event record, such as error record and compressor record. 3). SET : Touch it to enter the SET screen to set user parameters or factory parameters. 4). VIEW : Touch it to enter the VIEW screen to check the current running status of the unit, version information. etc. 5). HOME : Touch it to return to HOME screen. 10.3.2 Popped-up Window Smaller than the full screen, the popped-up window is attached to the current screen and is used for information prompt, data input, password input and modification, function setting, etc. The popped-up window can be moved correspondingly by touching and moving the control strip on the trop of the popped-up window. 10.3.3 Numerical Value Input Fig.3 Popped-up Window There are generally two ways to input the numerals. One is touching the key INC / DEC to increase/decrease the original value; the other is to directly input the numerals through the small keyboard, as shown below. Input by INC and DEC Fig. 4 Input by INC / DEC Input Input by small keyboard Fig.5 Input by Small Keyboard 26

Digital Multi VRF Technical Sales Guide By slightly touching the number input part, the small keyboard will appear along with the blinking cursor, which indicates values can be input herein. Then, touch the number on small keyboard to input the expected value. Finally, touch ENT to confirm the input and meanwhile the small keyboard disappear to end this input. Introduction to Buttons on the Small Keyboard 1 ). Number Button: they are used to input numbers 0~9. 2).. : it is used to input the decimal point. 3). ES : it is used to close the small keyboard and cancel the input. 4). CR : It is used to clear the currently input values and then input again. 5). ENT : it is used to confirm the input. After that, the small keypad will disappear and the input is ended. 10.3.4 Welcome Screen When the touch screen is powered on, what firstly emerges is the welcome screen as shown below and five seconds later it will switch to the HOME screen. 10.3.5 HOME Screen Fig.6 Welcome Screen HOME Screen 27

HOME screen is the main control screen and any other screen will be returned to the HOME screen if there is no any operation on the touch screen for 10min. HOME screen displays basic system information and control information such as system time, running status (OFF/ ON), chilled water-in/out temperature, cooling water-in/out temperature and compressor status. Additionally, it can also show if the unit is networked properly and if any error occurs. 1.This black part represents ON/OFF status of the compressor 1. When the compressor 1 starts up, black is changed to green; when the unit is turned off, it turns back to black. 2.Entering Chilled Water Temperature 3.Leaving Chilled Water Temperature 4.Entering Cooling Water Temperature 5.Leaving Water Temperature 10.3.6 SET Screen Touch SET on the menu bar and then a password input dialog box will pop up as shown below: Only after the correct password has been input (default:101010) is it available to go to the parameter setting screen though which the user can configure various parameters, including LCHW Temp Setting (Leaving Chilled Water Temperature), Oil Pump Control, Manual Oil-return, Water Storage, Timing Setting, Clocking Setting, Modbus Address, Control Mode, Remote Switch, Touch Sound, User Password, and Save to U Disk etc. as shown below. Fig.9 User Setting Screen The function of each touch button is described below: 1). INC : Slightly touch it to increase the set temperature. 2). DEC : Slightly touch it to decrease the set temperature. 3). Oil Pump Control : slightly touch it to select the desired option, Manual or Auto. Under 28

Digital Multi VRF Technical Sales Guide the Manual mode, it has two sub-options, On and Off. 4). Manual Oil-return : slightly touch it to select the desired option, Forbid, or Allow. 5). Control Mode : touch the option Manual or Timing of the Control Mode to select the desired one. Note: Under the Timing mode, the unit can also be turned on/off manually. Only when the timing setting is done and activated can Timing functions. However, when Remote Switch is set to Allow, Control Mode will be deactivated just with R. M. displayed where Manual or Timing once was. 6). Water Storage : Slightly touch it and then a dialogue box will pop up where parameters related to this function can be set. 7).Note: under this mode, the LCHW Temp Setting will be replaced by the Water Storage temperature setting which is un-adjustable. 8). Timing Setting : Touch it to go the Timer Set screen as shown below: Fig. 10 Time Setting Screen There are three timing modes: Mode 1, Mode 2, and Mode 3, each has 6 setting period. Each period include when to start the unit, when to stop the unit as well as if the timer setting is activated. Once the timer setting is done, by touching Mon./Tue./Wed/Thu./Fri./Sat./Sun., four mode options -- / 1 (Mode 1)/ 2 (Mode 2)/ 3 (Mode 3) will be available to be selected circularly. Notes: a.after the timing setting is done, only Control Mode is set to Timing can this setting work. b.if the timing ON and/or timing OFF in the same day is set to be the same, the latter period setting will always be given the priority to be executed. 8). Clock Setting : Touch Enter on the menu bar and then a dialog box will pop up where the year, month, day, hour, minute and second can be set. When setting, touch the part for inputting numeric value and then the small keyboard will pop up. After the desired values are input, touch Enter on the small keyboard to confirm and finish this operation. 9). Modbus Address : It is used to set the address of the touch screen for Modbus communication which will realize the long-distance monitoring to the air conditioning unit. However, this setting does work for the unit without this function. 10). Remote Switch : Touch the option Allow or Forbid of Remote ON/OFF to select the desired option. When Allow is selected, ON/OFF operation on the HOME screen and Timing do not work. 11). Touch Sound : By touching it two options ON / OFF of the Touch Sound are available to be selected alternately 12). User Password : It is intended for modifying user passwords, which is used to enter the User Setting screen as well as execute the ON/OFF operation on the HOME screen. 13). Save to U Disc : It is for the EVENT and CURVE download as for backup. Thus, data can be opened and viewed in the file format of txt through a computer. 14).Factory Parameter : slight touch Parameter and then a dialogue box will pop up which prompts to input the correct password. Factory parameters are mainly intended for 29

commissioning but not for the user. Modification to any parameter is password protected. Note: Haphazard modification to the factory parameters would cause serious impacts on the unit, so only professional personnel are allowed to take this operation. 15). English / 中文 : slightly touch English to go to the screen in English and 中文 to go to the screens in Chinese. 10.3.7 VIEW Screen Touch VIEW on the menu bar to enter the VIEW screen which provides detailed information for the running of the unit. There are totally 3 pages, first page: basic temperature and pressure data; second page: unit parameters, switching values of the water system, running information of the unit, etc; third page: switching value of the compressor. Fig.11 Page One Fig.11 Page Two Fig. 12 Page Three 30

Digital Multi VRF Technical Sales Guide 10.3.8 EVENT Screen 1). Touch EVENT on the menu bar to enter EVENT screen which provides users with specific running errors of the unit and information of other events, such as startup of the compressor. 2). Event records are classified into Current Event and History Event. Current Event displays the events after energization of the touch screen and they can only be found in the History Event after the touch screen is restarted. 3). Touch HISOTRY on the Current Event screen to enter the History Event screen. History Event is intended to record the events which have happened and would also be saved even if power failure occurs. In the History Event screen, touch PREV or NEXT to switch to the previous or next page which is listed in the date order. 4). CLEAR: touch it to clear the current error and take the error check again. Note: this function only enables the system to detect the error again after the error is manually cleared. However, the error has not been eliminated actually. Fig. 16 Current Event 10.3.9 CURVE Screen Fig. 17 History Event 1). Curve records are intended to display visually the status of key parameters of the unit (including both the temperature and pressure curves). 2). Curve records are classified into Current Curve and History Curve. Current Curve is used to record the curve data after the touch screen is energized and they can only be found in the History Curve after the touch screen is restarted. History Curve is used to record the events which have happened and would also be saved even if power failure occurs. 31

Fig. 16 Current Curve Fig. 17 History Curve 10.3.10 Others For saving energy, if there is no operation to the touch screen for 30min, backlight will be turned off automatically and the screen becomes black until next touch operation occurs. This touch screen is universally designed based on the maximum capacity of the system, applicable to both the unit with a single compressor and the one with two compressors. Therefore, some contents and functions of the touch screen may only be intended for some specific units but invalid or meaningless for others. For instance, if the unit is only with a single compressor, the display and control for the compressor 2 are inapplicable. Note: the touch screen saves data every 3 min. That is, as soon as some parameter is set, it would fail to save the parameters successfully if power failure occurs in 3min. Please consult the manufacturer for specific configurations of the unit. 10.3.11 Quick Search for Common Operations ON/OFF On the HOME screen, touch ON or OFF to send the unit-on or unit-off command, which will also be reflected on the HOME screen. Startup of the unit is passwords protected and only correct password enables the unit to be started up (default passwords: 101010). Control Mode Setting On the User Setting screen, touch the option Manual or Timing of the Control Mode to select the desired mode. Manual: The unit can be turned on or off manually and Timing doesn t work. Timing: Timing works but the unit also can be turned on or off manually. Note: if Remote 32

Digital Multi VRF Technical Sales Guide ON/OFF is set to Allow, the setting of Control Mode won t work but with Remote ON/ OFF displayed instead of Manual or Timing. Note: Only after the Control Mode is set to Timing as well as Timing is set and activated on the Timing Set Screen can Timing works. Leaving Chilled Water Setting On the User Setting screen it is allowed to set the leaving chilled water temperature, which can be increased or decreased by 0.1 through each touch on INC / DEC. Temperature Range Normal-Temperature Centrifugal Chiller : 3 ~ 30 ; Default: 7 ; Hi-Temperature Centrifugal Chiller :12 ~ 20 ; Default: 16 System Temperature View There are leaving chilled water temperatures, entering/leaving cooling water temperatures on the HOME screen. Also more details are available on the VIEW screen by touching VIEW. Error Clearing On the menu bar, touch EVENT to enter the EVENT screen and then touch CLEAR to clear the current error and take the error check again. Note: this function only enables the system to detect the error again after the error is manually cleared. However, the error has not been eliminated actually. Curve View Touch CURVE on the menu bar to the CURVE screen, in which temperature, pressure, master motor amperage, and position of the prerotation vane curves can be viewed. Event View Touch EVENT to enter the EVENT screen which contains latest errors of the unit and the status of compressor. An event record includes the occurrence time, recovery time and type of the error. Remote Switch On the User Setting screen, touch Remote Switch and two options Allow and Forbid will be available to be selected alternately. When Remote ON/OFF is set to Allow, ON/OFF operation on the HOME screen and also Timing do not work. Note: this setting can be done only when the unit is turned off. 33

11 BMS 11.1 Description to BMS BMS interface of Gree Central AC is only for Gree central AC devices. There is BMS interface or multifunctional gateway in the hardware and standard communication protocol and BMS software plug-in in the software. Gree central AC can be centrally monitored and managed through BMS interface together with other devices in the building. 11.2 Picture of Fittings Long-distance monitoring BMS interface kit is mainly composed of a communication module and a power adapter. They are sold together. Pictures of the power adaptor and communication module 34

Digital Multi VRF Technical Sales Guide 11.3 Installation and Selection of Water cooled centrifugal chiller 11.3.1Scope of Supply S=Standard parts; O= User Optional; P= User Provided Parts Scope of Supply Type Selection Remarks File of protocol Communication module ME30-27/E(M) Long distance monitoring set FC30-23/A(M) optoelectronic isolated converter RS232- RS485 Optoelectronic isolated repeater RS485 4-core twisted pair wire 3-way phone connector S S O O O P P Modbus protocol is used for user to integrate with BMS system. Including communication module ZJ9012, power transformer and connecting wire Including CD and optoelectronic isolated converter RS232- RS485 It is needed when the interface protocol of BMS system is RS232 One every 800m of communication distance equipped with one and One every 30 communication modules equipped with one. 11.3.2 Confirmation of Quantity of Parts Types Qty of Communication Modules Optoelectronic isolated converter Optoelectronic Isolated Repeater All types One unit equipped with a communication module ZJ9012 One if BMS COM is RS232 One every 800m of communication distance equipped with one. One every 30 communication modules equipped with one 11.3.3 Selection Example BMS COM is RS232,one converter is needed.3 sets of units LSBLX2000-M, 3 communication modules are needed, the communication distance is above 800m and one repeater is necessary and the quantity of communication modules is below 30 repeater is unnecessary, as follow: Project Requirements Qty(set) Communication module Quantity 3(LSBLX2000-M) 3(ZJ9012) Repeater 1 Optoelectronic Isolated Converter 1 35

11.3.4 Wiring Diagram 1) The connection way of the whole system 2) The connection way in the electrical cabinet Description of above communication cables Cable D2 D3 H2 Description both crystal head crystal head and the other end connects of it connects with wiring terminal of converter. both 9-core head (Standard parts) 36

Digital Multi VRF Technical Sales Guide 12 LONG-DISTANCE MONITORING SYSTEM 12.1 Introduction to Long-distance Monitoring System As the development and improvement of manufacturing technology and in order to solve the problems of complex distribution of the central AC in the buildings and difficult control and maintenance of them, an platform easy and reliable to operate must be provided to the users for daily management and maintenance. So this long-distance monitoring system combining electronic communication and computer technologies is developed to collect the running state of the units and to monitor and control the units from a long distance. Its structure is as follow: 12.2 nstallation and Selection of Water cooled centrifugal chiller 12.2.1Scope of Supply S=Standard parts; O= User Optional; P= User Provided Parts Scope of Supply Type Selection Remarks PC Communication module set ME30-27/E(M) Water cooled centrifugal chiller Long-distance Monitoring System set FC30-23/A(M) Optoelectronic isolated repeater RS485 4-core twisted pair wire 3-way phone connector P S S O P P Including communication module ZJ9012, power transformer and connecting wire Including CD and optoelectronic isolated converter RS232- RS485 One every 800m of communication distance equipped with one and One every 30 communi cation modules equipped with one. 12.2.2 Scope of Supply Types All types Qty of Communication Modules One unit equipped with a communica tion module ZJ9012 Long-distance Monitoring System Water cooled centrifugal chiller Long-distance Monitoring System set FC30-23/A(M) Optoelectronic Isolated Repeater One every 800m of communication distance equipped with one. One every 30 communication modules equipped with one 12.2.3 Selection Example 3 sets of units LSBLX2000-M, 3 communication modules are needed, the communication distance is above 800m and one repeater is necessary and the quantity of communication modules is below 30 repeater is unnecessary, as follow: Project Requirements Quantity Qty(set) Water cooled centrifugal chiller Long-distance Monitoring System FC30-23/A(M) Communication module 3(LSBLX2000-M) 1 3(ZJ9012) Repeater 1 Optoelectronic Isolated Converter 1 37

12.2.4 Wiring Diagram 1) The connection way of the whole system 2) The connection way of the whole system Description of above communication cables Cable D2 D3 H2 Description both crystal head crystal head and the other end connects of it connects with wiring terminal of converter. both 9-core head (Standard parts) 38

Gree Electric Appliance, Inc. of Zhuhai, founded in 1991, is the world's largest air conditioner enterprise integrating R&D, manufacturing, marketing and services. Technology Innovation and quality are always our priority. With efforts of thousands of Gree's engineers, we own more than 3500 patents for our products. Nowadays, we have 7 production bases in Zhuhai, Chongqing, Hefei and Zhengzhou(China), as well as Brazil, Pakistan and Vietnam, with annual production capacity of 30 million sets of residential air conditioners and 4 million sets of commercial air conditioners. With the installation of Gree commercial air conditioners in important projects at home and abroad like Media Village for 2008 Beijing Olympic Games, Stadiums for 2010 World Cup in South Africa, as well as India Telecom base station, Gree commercial air conditioners are ready to develop steadily to every corner in the world, to present a more comfortable and harmonious working environment and family atmosphere. GREE MAKING BETTER CONDITINERS GREE MAKING BETTER CONDITINERS GREE MAKING BETTER CONDITINERS GREE MAKING B Add: West Jinji Rd,Qianshan Zhuhai,Guangdong,China519070 Tel: (+86-756)8614883 Fax: (+86-756)8614998 Http://www.gree.com Email: gree@gree.com.cn For continous improvement in the products, Gree reserves the right to modify the product specification and appearence in this manual withotu notice and without incurring and obligations. SN00300032