Input/Output Modules Data Sheet

Similar documents
Interface Modules for SENTRI

Air Sampling Smoke Detection

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

INPUT / OUTPUT MINI MODULES

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

D7053. Installation Instructions Multiplex Input/Output Module

Excel-EN Conventional Fire Control Panel

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

SOUNDER CONTROL MODULE SCM-AS4

Application Guide 001

AU MX Digital Loop Card Installation Instructions

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

EXTINGUISHING AGENT RELEASE MODULE

Interface and EOL Modules 8

intelligent fire alarm ID60series panels

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Installation, Operating and Maintenance Manual

Opal TM AV Devices. Data Sheet. Benefits

ID50series. intelligent fire alarm panels

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

DS7465i. Installation Instructions. Input/Output Module

FEC403EN Installation Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Touch Screen 1 loop Addressable Fire Alarm Panel

ECO N DATE DESCRIPTION OF CHANGE CHG

Power Supply Display Module PSDM. Installation and Operation Manual

Booster Power Supply Manual

PSN-1000 & PSN 1000(E) Installation Manual

MINERVA MX. 800 Series Ancillary Equipment

Honeywell Air Sampling Devices Data Sheet

2000 Series Sensors Installation Guide

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Opal TM AV Devices. Data Sheet. Benefits

INSTALLATION INSTRUCTIONS

General Routing Interface

ID3000 intelligent. fire alarm panel

ID2000. intelligent fire alarm panel

System 800 Addressable Fire Detection & Alarm System

OPERATION AND INSTALLATION MANUAL

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

ZXSe Range Data Sheet

Heat Sensor Cable Alarm Units DT650L / DT950L

AL600ULADA. NAC Power Extender. Installation Guide

IGD.CO.UK

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Solution F2. Fire Alarm Control Panels one step ahead.

Addressable Loop Modules

FireNET Plus Wiring Instructions

Model 17A00 Expansion Enclosure

TrueAlarm Analog Sensing

Conventional Fire Alarm System 2014 V1.2

Multiplex Eight Input Remote Modules

DCP-FRCME - FAST RESPONSE CONTACT MODULE

An introduction to... Sigma

D7052. Installation Instructions Multiplex Dual Input Module

Door Release Power Supply

TECHNICAL DATA OBSOLETE

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Using Non-Twisted Flat Cable in Analogue Addressable Retrofits

D250A/D253/D261AW/D280A/D290 Series

Multiple Input and Output Modules

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

XP95 Sounder VAD Base

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

AP200 SERIES INTELLIGENT ALARM DEVICES

Remote NAC Power Supply D7038

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Application, Installation, Operation & Maintenance Manual

Electric Release Panel Wiring Tips

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Intelligent addressable fire alarm control panel

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Consultant Specification AGILE Wireless Fire Detection System

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

For Complete Fire and Gas Solutions

FL2011EI-HS FL2012EI-HS FL2022EI-HS

Fire Alarm Panels. Product Manual.

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

FEC400 Series. Installation Manual

30.45 Electric Release PDRP-2001

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Honeywell Air Sampling Devices Data Sheet

Addressable NAC Output Module D327A

OPERATION / INSTALLATION

SIGA-CC1 Single Input Signal Module Installation Sheet

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

Conventional Fire Detection

AL800ULADA. NAC Power Extender. Installation Guide

AP200 SERIES INTELLIGENT ALARM DEVICES

SINGLE MONITORED INPUT UNIT BN-303

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

Transcription:

Input/Output Modules Data Sheet The wide range of input and output modules available from NOTIFIER delivers exceptional flexibility to a NOTIFIER fire detection and alarm system. Using these modules enables integration with a host of other building management and emergency systems, including access control systems, lifts, fire shutters and emergency lighting. Features Analogue addressable communications Builtin type identification automatically identifies these devices to the control panel (not MX) Stable communication technique with high noise immunity Rotary DECADE to address switches (not MX) Common mounting options including Surface Mount, Panel Mount and DIN Rail Mount. Tricolour LED s Powered directly by wire loop. No additional power required Plugin terminal connections for ease of field wiring Approved to CEA GEI AND CEA GEI 4 CPD approval to EN54 and EN54, LPCB and VdS Installation The M series modules can be mounted either surface, panel mounted in other equipment housings or DIN rail mounted in other equipment housings. Surface mounting is achieved by using the MESMB surface mount box which accepts a single module. This box has a frosted plastic lid with viewing windows for the product identification label, LED s and address switches. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH5 UF. United Kingdom Phone: 44 () 444 3 3 Fax: 44 () 444 3 Page of 53_4 ISO Design, Manufacture and Supply to Quality Management Systems Certified to ISO:4

M Single input module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M module monitors a single input device circuit of normally open dry contact alarm activation devices. These modules use one of available module addresses on a loop and respond to regular polls from the control panel reporting its type and the status (open/normal/short) of its supervised device circuit. M Single input module Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. 3 µa @ 4 VDC; 5 µa @ 4 VDC Maximum Alarm Current: 5 ma @ 4 VDC (per LED with LED enabled) Operating Voltage: 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page of 53_4

Non Addressable Zone Monitor Module MCZR The MCZR nonaddressable zone monitor module allows a zone of nonaddressable detectors to communicate with a Notifier analogue addressable system. As a result existing nonaddressable loops can be integrated into a Notifier addressable system The module monitors a zone of twowire nonaddressable smoke detectors. Each MCZR uses one of available module addresses on a loop. The nonaddressable zone can be powered from the analogue communication line or from an external power supply. Where the nonaddressable zone is powered from an external power supply, the communication line is fully isolated from the nonaddressable zone and from the power supply. This MCZR nonaddressable Zone Monitor module fits into MESMB, MEDIN or MEPMB. These may then be installed in a Rack Assembly using Notifier Rack mounting adapters. Non Addressable Zone Monitor Module MCZR Weight: 3 mm 3 mm 3 mm g Operating Voltage Range: to.5vdc Max. Standby Current: μa maximum (conventional zone connected to external supply) LED Current Red:.μA @ 4Vdc Green: 6.6μA @ 4Vdc Yellow:.μA @ 4Vdc End of Line Resistor Value: 3.k Temperature Range: Humidity: C to 6 C 5% to 5% relative humidity (noncondensing) 3mm MEDIN MESMB 3mm 3mm MEPMB 3mm 4mm 34mm Page 3 of 53_4

M Single output module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M control module provides a monitored single output circuit for use with polarised loads (sounder circuit) which requires a suitable power source (Vdc 3Vdc) for the connected load. Alternatively the same device may be placed in to an unsupervised mode which can then be used to control any switched load up to A @ 3Vdc. In addition the M4 and the M4DIN provide two ( x N.O. x N.C.) 5Vac (nominal 3Vac), 5Amp contact outputs. The M4 is provided complete with a surface mounting back box and the M 4DIN is supplied in a DIN rail mounting package. These modules use one of available module addresses on a loop and respond to regular polls from the control panel reporting its type and the status (open/normal/short) of its supervised device circuit. M single output module mm mm 3 mm Weight: M g M4 g M4DIN 5g Current Consumption (Without communication) M 3 µa @ 4 VDC M4 & M4DIN 5 µa @ 4 VDC Current Consumption (Communication every 5 sec. with LED blink enabled) M 5 µa @ 4 VDC M4 & M4DIN 445 µa @ 4 VDC Maximum Alarm Current: Operating Voltage: 5 ma @ 4 VDC (per LED with LED enabled) 5 to 3 VDC peak C to 6 C % to 5%, noncondensing M mm M4DIN M4 5mm 3mm 3mm mm 4mm 6mm 4mm 34mm Page 4 of 53_4

M Dual Input Module The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M dual monitor module provides two supervised input device circuits of normally open dry contact alarm activation devices. The M module uses two addresses of available module addresses on a loop and responds to regular polls from the control panel reporting its type and the status (open/normal/short) of their supervised device circuits. M Dual Input Module Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. 34 µa @ 4 VDC; 6 µa @ 4 VDC Maximum Alarm Current: 5 ma @ 4 VDC (per LED with LED enabled) Operating Voltage: 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page 5 of 53_4

M Dual Input Module with Output The M series modules are designed for use with any NOTIFIER protocol fire alarm control panel and include selectable loop isolation in every device. The M dual input, single relay output module, as well as providing two supervised inputs also provides a single change over relay output rated at A @3Vdc. The M uses three addresses of available module addresses on a loop and responds to regular polls from the control panel reporting its type and the status (open/normal/short) of their supervised device circuits. M Dual Input Module with Output Weight: mm mm 3 mm g Current Consumption Without communication Communication every 5 sec. with LED blink enabled. Maximum Alarm Current: Operating Voltage: 34 µa @ 4 VDC; 66 µa @ 4 VDC 5 ma @ 4 VDC (per LED with LED enabled) 5 to 3 VDC peak C to 6 C % to 5%, noncondensing mm MEDIN MESMB 3mm mm MEPMB 3mm 4mm 34mm Page 6 of 53_4

Way Output Module CMXRM Each output is individually addressed and controlled by the control equipment. This provides a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Each output consists of a form C (change over) relay contact providing both normally open and normally closed contacts rated A at 3Vdc. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. Way Output Module CMXRM 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 5mA @ 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4

Way Input Module MMXM Each input is individually addressed and controlled by the control equipment. This provides a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Inputs may be configured to monitor for open circuit, short circuit and active (fire) conditions. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. Way Input Module MMXM 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 5mA @ 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4

5 Way Input and 5 Way Output Module MCX55 Each input and output are individually addressed and controlled by the control equipment and provide a cost effective, compact solution for installations requiring multiple switching and / or monitoring at a single location. Inputs may be configured to monitor for open circuit, short circuit and active (fire) conditions. Each output consists of a form C (change over) relay contact providing both normally open and normally closed contacts rated A at 3Vdc. Each module card utilises up to consecutive addresses with the base address being set by DIP switch although any of the addresses may be individually disabled allowing the use of this address by other modules on that loop. M Dual Input Module with Output 33 mm mm 3 mm Current Consumption.mA with communication and LED blink enabled LED Current, 5mA @ 4Vdc (LED on) per module The modules are supplied as a P.C.B. allowing installation in to other equipment housings such as control cabinets. 5 x 3.5mm mounting holes provide suitable secure mounting for the P.C.B s as indicated overleaf. Each module occupies a single Notifier Loop Module address with the first address being set by DIP switch SW and subsequent address being base address n up to a maximium of. Individual modules may be disabled via a second DIP switch SW such that any module address in the range can be used for other module addresses on the loop. Connection Detail C to 55 C % to 3%, noncondensing Mounting Detail Page of 53_4

Connection Detail M / M Connection Detail Notes: (See notes ) 6 5 4 3 M / M A B If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. The dashed line circuit connected to terminals and should only be used with the M. There are no connections to these terminals on the M. 3 Provided the control panel is compatible, short circuit monitoring of the input circuit may be possible. An K Ohm resistor should be wired in series with each device switch being monitored. 3 6 3 6 A x B x C 4KΩ 4KΩ See Note M Connection Detail (See notes ) M A B 3 4 6 5 Notes: If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. Provided the control panel is compatible, short circuit fault monitoring of the input circuit may be possible. An K Ohm resistor should be wired in series with each device switch being monitored. 3 6 3 6 A x B x C 4KΩ 4KΩ NC C NO Relay Contact Rating: 3VDC, A resistive load MX Connection Detail 6 5 4 3 MX Page of 53_4

Connection Detail EOL (See notes ) External Power Supply Maximum 3VDC, Minimum VDC See Note 3 M Supervised Connection Detail 3 4 5 6 3 M 6 See Note 5 and Table 3 A x B x C 6 A B Table : EOL Monitoring Options Mode Switch A Switch B EOL Device Load Position Position Std 4KΩ Resistor See Note 4 VdS Polarised 4Ω See Note 5 RLY N/A Unsupervised Notes: If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. To enable output circuit supervision, the link supplied must be fitted across terminals 6 and, and the load must be polarised. 3 In supervised mode, the module monitors the power supply voltage across terminals and to ensure it does not drop below V, and also monitors for a switched negative fault signal from the power supply to terminal (optional). If a fault is seen the yellow LED will blink, and a fault may be indicated at the panel. The use of this fault warning is dependant upon panel software, please consult Notifier Technical support. 4 Up to.5a load can be driven subject to the supply capability, total cable resistance and minimum voltage required by the load. 5 An alternative end of line monitoring option is available for VdS 4 requirements see table. Maximum cable series resistance is R so max. load current is limited by permissible voltage drop along the cable, min. PSU voltage and min. load voltage requirement. eg: Min PSU voltage = V, min load voltage = V, max. series resistance = R, therefore max. current = 3mA [( )/ Amps.] M UnSupervised Connection Detail Notes: (See note ) { Relay Contact Rating: 3VDC, A resistive load N.C C N.O 6 5 4 3 3 6 M 3 6 A B If short circuit isolation is not required, loop output should be wired to terminal 5 and not. Terminal 5 is internally connected to terminal 4. A x B x C N/O Input N/C Input Ground Ground N/C Output N/O Output M4 / M4DIN Connection Detail 3 6 3 6 3 4 5 6 Loop, Out Loop, Out See Note Loop, In Loop, In Loop, Out See Note T6 Not Connected Notes:. If short circuit isolation is not required, then the loop output should be wired to terminal 5 rather than terminal. Terminal 5 is internally connected directly to terminal 4.. In order to meet the requirements of European Safety Standards, ensure that all cables carrying voltages in excess of 4V (Live and Neutral) are suitably fused. Page of 53_4

Product Range at a Glance Part Number Single isolation module. MX Single output module M Single input unit M Dual input unit M Dual input, single output module M Single 3Vac output unit inc. surface mount box M4 Single 3Vac output unit inc. DIN rail mounting enclosure M4DIN Surface Mount Box MESMB Surface Mount Box for 6 Mxx series modules SMB6V Panel Mount Bracket MEPMB DIN rail mounting clip MEDIN Way Relay Output Module CMXRM Way Input Module MMXM 5 Way Input & 5 Way Relay Output Module MCX55 Page of 53_4 Charles Avenue Burgess Hill W. Sussex RH5 UF T: 44 () 6 46 55 F: 44 () 6 46 E: sales@notifierfiresystems.co.uk