YAH SERIES FAN COIL UNITS

Similar documents
YAH Series Air Handling Units

YAH Series Air Handling Units

On the cover Integrated professional services designed for your unique business need.

EHH SERIES DRAW THROUGH FAN COILS CFM

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

C13-Series Engineering Guide

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

LOW STATIC HYDRONIC DUCTED UNIT

Concealed Ducted Split Series R-407C MBH

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Cooling/Heat Pump Convertible Air Handlers

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

VertiCool Aurora Engineering Guide

Cooling/Heat Pump Convertible Air Handlers

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

VERTICAL FAN COIL UNITS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Cooling/Heat Pump Convertible Air Handlers

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW

EC Motor Fan Coil Units. IMD-Y Series l/s

FCC Fan-Coil Units High-Performance, Vertical

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Highly Efficient,Powerful Heating and Cooling.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MHW Air Handling Unit (50/60Hz)

COMMERCIAL AIR HANDLER

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

FAN COIL UNITS. The optimal solution for limited space

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

technical guide Water-Cooled Self-Contained Units

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

SKYPAK II, 3 Ton Series, gives you a

SECTION FAN COIL UNITS

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

COMMERCIAL AIR HANDLER

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Evaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series

Product Specifications. Vertical Floor Consoles By First Co.

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

ED-FUW-2014 (50 Hz/60 Hz) Catalogue/Engineering Data. Large-Sized Chilled Water Fan Coil Unit (50/60 Hz) FUW040A DAIKIN INDUSTRIES, LTD.

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Advance Release September 2009

VariCool VAV Engineering Guide

Commercial High-Efficiency Condensing Units

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

40 RM/RMS Packaged Air-Handling Units

Water-Cooled Self-Contained Units

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

technical data Fan coil unit FWB small duct unit

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

PACKAGE AIR CONDITIONER

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

KAP Horizontal Product Coolers

ELECTRICAL QUANTITY WEIGHT (LB)

Vertical Upflow Horizontal Left Air Handlers

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

Transcription:

YAH Series Fan Coil Units Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central air-conditioning systems. They are designed for fresh air units or to cool, heat, humidify and de-humidify, filter and clean the air, etc. The conditioned air can be delivered to locations across various distances via specially designed ducts. The units are especially suitable for the air-conditioning of commercial buildings and industry applications. YORK YAH series fan coil units have 10 different models. The cooling capacity ranges from 7.8kW to 240.4kW, and air flow from 1500m 3 /h to 15000m 3 /h. Rated external total pressure ranges from 180 to 340 Pa. More external total pressure can be provided for flexible application. Each unit is made from galvanized steel with 10mm thick polyethylene inner insulation. It contains a built-in cooling coil and fan, and externally mounted nylon air filters. Cooling and heating coil use copper tubes with corrugated fins. The fan, motor and belt pulley are all high-quality products producing stable and efficient performance. The fan is a forward curved centrifugal model that works on double air inlets. The motor features IP55 and a type F insulation with self-lubricating bearings, and standard motor efficiency reaches to IE3 class(iec60034-30). The externally mounted filter can be withdrawn from side or bottom. Features Nomenclature & Features Easy installation Lower unit height for low floor ceiling application Low noise Filter can be withdrawn from side or bottom Johnson Controls YORK YAH Ceiling Mounted Cabinet Fan Coil Unit YAH: YORK Ceiling Mounted Air Handling Unit Nominal airflow: model code X 10 3 m 3 /h Design serial number: D External total pressure code: 1-Nominal external total pressure Fan drive type: B-Belt-driver fan YAH 04 B 4 1 0 0 0 0 0 0 L 1 D Pipe Connection: L - Left Handling R - Right Handling Cooling coil: 4-4 Rows coil 6-6 Rows coil Air condition: 0-Return air condition X-Fresh air condition Heating coil: 0- Without heating coil 1-1 Row heating coil 2-2 Rows heating coil Evaporative humidifier: 0-Without humidifier Power supply: C-380-415V/3N~/50Hz D-460V/3N~/60Hz E-380V/3N~/60Hz F-230V/3N~/60Hz Filter: 0-G1(Nylon) filter A-G1(Aluminium mesh) filter B-G3 Plate filter C-G4 Plate filter Fin type: 0-Common fin H-Hydrophilic fin TiO2: 0-Without TiO2 2

YAH Series Fan Coil Units - Main Technical Data MODEL YAH 1.5 02 03 04 05 06 08 10 12 15 COIL DEPTH Row 4 6 4 6 4 6 4 6 4 6 4 6 4 6 4 6 4 6 4 6 "Return Air Condition Nominal Cooling Capacity" "Return Air Condition Nominal Heating Capacity" "Fresh Air Condition Nominal Cooling Capacity" "Fresh Air Condition Nominal Heating Capacity" ton 2.2 3.2 3.2 4.2 4.9 6.3 6.3 8.7 7.7 10.9 9.6 12.3 13.1 17.0 16.5 22.0 20.4 24.9 26.4 32.2 MBH 26.5 38.6 38.2 50.2 58.2 75.4 75.3 103.9 92.0 131.0 114.9 147.2 157.5 203.8 197.7 263.7 244.4 299.0 316.9 386.3 kw 7.8 11.3 11.2 14.7 17.1 22.1 22.1 30.5 27.0 38.4 33.7 43.1 46.2 59.7 57.9 77.3 71.6 87.6 92.9 113.2 ton 3.8 4.7 5.0 6.1 7.8 9.5 10.6 13.1 13.3 16.4 16.5 18.0 23.5 26.9 28.9 33.8 35.6 40.0 44.9 50.4 MBH 46.1 56.6 60.4 73.0 93.5 113.6 127.6 157.0 160.0 197.2 198.2 215.7 281.5 322.8 346.3 405.1 426.9 480.1 538.4 604.7 kw 13.5 16.6 17.7 21.4 27.4 33.3 37.4 46.0 46.9 57.8 58.1 63.2 82.5 94.6 101.5 118.7 125.1 140.7 157.8 177.2 ton 5.3 7.0 7.0 9.2 10.4 13.7 14.6 18.9 18.2 23.3 19.8 28.9 27.8 39.1 35.6 49.3 42.2 57.7 55.1 73.4 MBH 64.2 83.9 84.3 109.9 124.9 164.1 175.7 226.9 218.7 279.1 237.8 347.4 334.0 468.9 427.2 591.4 506.4 692.4 661.3 880.4 kw 18.8 24.6 24.7 32.2 36.6 48.1 51.5 66.5 64.1 81.8 69.7 101.8 97.9 137.4 125.2 173.3 148.4 202.9 193.8 258.0 ton 5.5 6.5 7.1 8.5 11.7 13.3 14.1 16.2 17.2 19.8 19.6 24.3 30.3 37.0 39.6 46.0 46.5 54.4 58.9 68.4 MBH 65.9 78.5 85.0 101.7 139.9 159.7 168.9 194.5 206.4 237.5 235.8 291.4 363.0 444.0 475.3 552.5 557.9 652.8 706.3 820.4 kw 19.3 23.0 24.9 29.8 41.0 46.8 49.5 57.0 60.5 69.6 69.1 85.4 106.4 130.1 139.3 161.9 163.5 191.3 207.0 240.4 FAN MOTOR Type / Drive Centrifugal DWDI Forward Curve / Belt Driven Size 7/7 (1) 7/7 (1) 7/7 (2) 7/7 (2) 9/7 (2) 9/7 (2) 9/9 (2) 15/15 (1) 15/11 (2) 15/11 (2) Nominal Airflow CFM (m3/h) 883(1500) 1177(2000) 1766(3000) 2354(4000) 2943(5000) 3531(6000) 4709(8000) 5886(10000) 7063(12000) 8829(15000) Design Ext. Static Pressure in.wg (Pa) 0.4(100) Designed Nominal Fan Speed RPM 1324 1469 1369 1487 1419 1568 1450 1597 1192 1267 1294 1364 1240 1304 791 849 708 772 747 809 Design Motor Size HP (kw) 0.75(0.55) 0.75(0.55) 0.75(0.55) 0.75(0.55) 1(0.75) 1(0.75) 1.5(1.1) 1.5(1.1) 2(1.5) 2(1.5) 3(2.2) 3(2.2) 3(2.2) 4(3) 3(2.2) 4(3) 3(2.2) 4(3) 4(3) 5.5(4) Max. Running Amp for Operating Motor @ 50Hz, 415V A 1.26 1.26 1.69 2.39 3.18 4.36 4.36 5.80 4.36 5.80 4.36 5.80 5.80 7.66 MAXIMUM OPERATING @ NOMINAL AIR FLOW Max. Ext. Static Pressure in.wg (Pa) 2.07(516) 1.85(461) 1.49(372) 1.29(322) 1.86(463) 1.64(408) 0.60 (150) 0.40 (100) 0.70 (175) 0.50 (125) 0.70 (175) 0.50 (125) 0.70 (175) 0.50 (125) 1.70 (425) 1.60 (400) 0.70 (175) 0.50 (125) 1.70 (425) 1.60 (400) Max. Operating Fan Speed RPM 2160 1952 2199 1980 1713 1816 1799 1183 1112 1124 Max. Operating Motor Size HP (kw) 1.00 (0.75) 1.00 (0.75) 2.00 (1.50) 2.00 (1.50) 3.00 (2.20) 4.00 (3.00) 5.50 (4.00) 5.50 (4.00) 5.50 (4.00) 7.50 (5.50) Max. Running Amp for Operating Motor @ 50Hz, 415V A 1.69 1.69 3.18 3.18 4.36 5.80 7.66 7.66 7.66 10.3 COIL 3/8" 1/2" Type Seamless Copper Tube / Corrugated Aluminum Fin Tube Thickness / Fin Thickness mm / mm 0.30 / 0.115 0.34/0.115 Face Area ft2 (m2) 1.64(0.15) 2.25(0.21) 3.28(0.3) 4.43(0.41) 5.47(0.51) 6.56(0.61) 8.75(0.81) 10.77(1) 12.82(1.19) 16.06(1.49) Coil Static Resistance in.wg (Pa) 0.54 (135) 0.76 (190) 0.56 (140) 0.76 (190) 0.58 (145) 0.8 (200) 0.58 (145) 0.8 (200) 0.6 (150) 0.82 (205) 0.6 (150) 0.82 (205) 0.6 (150) 0.84 (210) 0.56 (140) 0.8 (200) 0.58 (145) 0.8 (200) 0.58 (145) 0.82 (205) Return Condition Fin Per Inch FPI 13 12 13 12 Fresh Air Condition Fin Per Inch FPI 10 USgpm 5.30 7.70 7.50 10.00 11.60 14.90 15.10 20.80 18.40 26.30 23.10 29.20 31.10 40.90 39.00 52.70 48.60 60.10 62.70 76.20 Return Condition Water Flow Rate l/s 0.33 0.49 0.48 0.63 0.73 0.94 0.95 1.31 1.16 1.66 1.46 1.84 1.97 2.58 2.46 3.33 3.07 3.79 3.96 4.81 USgpm 12.80 16.50 16.70 21.90 24.70 32.60 35.30 45.50 43.40 56.00 47.10 69.30 66.30 93.60 85.50 117.90 101.10 137.90 130.80 176.60 Fresh Air Condition Water Flow Rate l/s 0.81 1.04 1.05 1.38 1.56 2.06 2.22 2.87 2.74 3.53 2.97 4.37 4.18 5.90 5.39 7.44 6.38 8.70 8.26 11.14 ft.wg 4.50 12.70 8.90 7.50 22.70 16.10 8.60 20.50 7.80 20.20 12.30 10.70 23.90 17.00 13.10 10.40 7.20 5.30 13.40 9.30 Return Condition Water Pressure Drop kpa 13.50 38.00 26.70 22.30 67.90 48.20 25.70 61.40 23.20 60.50 36.70 31.90 71.40 50.70 39.10 31.20 21.60 15.70 40.10 27.70 ft.wg 14.80 12.90 17.90 12.70 22.30 18.80 31.20 26.50 39.10 29.50 7.40 40.90 12.20 63.10 3.60 15.50 5.30 23.70 9.70 43.80 Fresh Air condition Water Pressure Drop kpa 44.20 38.60 53.50 37.90 66.60 56.20 93.10 79.20 117.00 88.10 22.10 122.40 36.60 188.60 10.90 46.20 15.80 70.70 29.00 130.80 Header Type Black Steel Pipe (BSPT Male Threaded) Return Condition Nominal Header Size in 1" 1" 1" 1" 1" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2" 1-1/2" 2" 2" 2-1/2" 2" 2-1/2" 2" 2-1/2" Fresh Air Condition Nominal Header Size in 1" 1" 1" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 2" 2" 2" 2" 2" 2-1/2" 3" 2-1/2" 3" 2-1/2" 3" CASING Casing and Insulation Galvanized Steel c/w 10mm Polyethylene (PE) Foam DRAIN PAN Material and Finishing Galvanized Steel c/w Epoxy Polyester Powder Coating Connection 1-1/4" O.D. Steel Pipe (BSPT Male Threaded) FILTER Filter Type Nominal 1" Washable Nylon Filter Qty / Unit 1 1 2 2 2 2 3 2 3 3 Nominal Size in 12*28 12*31 12*24 12*29 16*27 16*32 16*28 24*34 24*26 24*33 Actual Size mm 303*707 303*792 303*608 303*728 394*678 394*803 394*701 622*853 622*668 622*826 OVERALL DIMENSION Height in (mm) 16.4(417) 16.4(417) 16.4(417) 16.4(417) 20(508) 20(508) 20(508) 29(736) 29(736) 29(736) Width in (mm) 33.5(850) 36.8(935) 53.5(1360) 63(1600) 59.1(1500) 68.9(1750) 88.6(2250) 72.8(1850) 84.6(2150) 103.3(2625) Depth in (mm) 33.9(860) 33.9(860) 33.9(860) 33.9(860) 37(940) 37(940) 38.6(980) 43.3(1100) 45.3(1150) 46.1(1170) PACKING DIMENSION Height in (mm) 24.7(627) 24.7(627) 24.7(627) 24.7(627) 28.3(718) 28.3(718) 28.3(718) 37.2(946) 37.2(946) 37.2(946) Width in (mm) 42.1(1070) 45.5(1155) 62.2(1580) 71.7(1820) 67.7(1720) 77.6(1970) 97.2(2470) 81.5(2070) 93.3(2370) 112(2845) Depth in (mm) 44.5(1130) 44.5(1130) 44.5(1130) 44.5(1130) 47.6(1210) 47.6(1210) 49.2(1250) 53.9(1370) 55.9(1420) 58.7(1490) Estimated Shipping Weight kg 90 94 97 103 132 140 155 165 171 183 193 208 237 256 264 292 321 355 377 419 1. The weight listed in the table is the shipping weight. The operation weight of unit is about 20% more than the shipping weight. 2. Standard return air cooling conditions: air inlet at 80 F (26.7 ) DB / 67 F (19.4 C) WB; chilled water inlet/outlet at 44 F (6.7 C) / 54 F (12.2 C). 3. Standard return air heating conditions:air inlet at 21 CDB; hot water inlet/outlet at 60 C/50 C. 4. Cooling conditions of fresh air unit: air inlet at 95 F (35 C) DB/ 83 F (28.3 C) WB; chilled water inlet/outlet at 44 F (6.7 C) / 54 F (12.2 C). 5. Heating conditions of fresh air unit: air inlet at 7 C DB; hot water inlet/outlet at 60 C/50 C. 6. External total pressure: the sum of velocity pressure and static pressure at the air discharge outlet (exclude the pressure drop across the unit) 7. For four-piped unit, heating coil is in the front of the cooling coil in the direction of air flow. 8. If the unit has split coil (cooling+heating) option, the external total pressure should be deducted by the responding air drop pressure * The unit performance is based on 5m altitude, the variance of altitude will affect the unit performance Altitude Correction Factors Altitude(m) 300 900 1200 1500 1800 Total heat 0.99 0.97 0.96 0.94 0.93 Sensible heat 0.96 0.90 0.96 0.83 0.80 Note: The above is only for reference. Please contact our local office for detailed data. 4

YAH SERIES FAN COIL UNITS Specifications Electric Wiring Diagrams Electric Connection: 1. The direct start schematic diagram (Fig.1) is for motor up to 5.5kW. The Y- start schematic (Fig.2) for motors more than 7.5kW. 2. The dashed lines is provided by customer and it should be connected according to Fig.1 or Fig.2. Please ensure that all connections are tightened. 3. All electric connections should comply with local electric installation codes. 4. The ground terminal of the unit must be connected to the ground terminal in the control panel. 5. Customer should connect the power and control devices and supply short-circuit and over heat protection. Each unit is made from galvanized steel with 10mm thick polyethylene inner insulation. It contains a built-in cooling coil and fan, and externally mounted nylon air filters. Notes for Placing Orders 1. The motor power is 380-415V/3N-/50Hz, 460V/3N-/60Hz, 380V/3N-/60Hz or 230V/3N-/60Hz, 4 wires. 2. The unit is equipped with plate type pre-filters at the return air intake. 3. When placing an order, the pipe direction (left connection or right) should be noted (note: facing the return air intake, it is the right if the inlet/outlet water pipes are on the right side of unit and vice versa). 4. The airflow rate and total pressure should be noted when placing an order. 5. If starter is required, it should be noted when placing an order (an option). Physical Data Model Notes "Airflow m 3 /h" 1. When G is -, the unit has only one air supply duct connection. 2. The coil pipe connections use male threads(bspt) the corresponding imperial diameters are: 34mm---1 42mm---1-1/4 48mm---1-1/2 60mm---2 76mm---2-1/2 89mm---3 3. The condensate pipe connections use 34mm O.D. male threads(bspt). 4. All dimensions are SI unit(mm). Unit Drawings L W H Supply air flange size Piping position Return air flange size Coil piping (Connection diameter) K R A B C D E F G H J Return L M N P Q Return Return Fresh air Fresh air Fresh air air 4 6 Rows air 4 air 6 4 Rows 4 Rows 6 Rows Rows Rows Rows YAH1.5B 1500 860 850 417 410 259 228-73 53 66 66 110 400 144 319 710 320 Ø34 Ø34 Ø34 Ø34 YAH02B 2000 860 935 417 410 259 228-73 53 66 66 110 400 144 319 795 320 Ø34 Ø34 Ø34 Ø48 YAH03B 3000 860 1360 417 470 259 228 184 73 53 66 66 110 400 144 319 1220 320 Ø34 Ø48 Ø48 Ø48 YAH04B 4000 860 1600 417 520 259 228 184 73 53 66 66 110 400 144 319 1460 320 Ø48 Ø48 Ø48 Ø48 YAH05B 5000 940 1500 508 580 232 262 184 107 63 66 66 110 400 144 420 1360 411 Ø48 Ø48 Ø48 Ø60 YAH06B 6000 940 1750 508 551 232 262 184 107 63 66 88 110 400 144 420 1610 411 Ø48 Ø60 Ø60 Ø60 YAH08B 8000 980 2250 508 705 298 262 244 107 63 66 88 110 400 144 420 2110 411 Ø48 Ø60 Ø60 Ø60 YAH10B 10000 1100 1850 736 690 471 404-112 77 83 110 138 441 145 641 1710 639 Ø60 Ø76 Ø76 Ø89 YAH12B 12000 1150 2150 736 690 373 404 294 112 77 83 110 138 441 145 641 2010 639 Ø60 Ø76 Ø76 Ø89 YAH15B 15000 1170 2625 736 793 373 40 294 112 77 83 110 138 441 145 641 2485 639 Ø60 Ø76 Ø76 Ø89 Note: The above applies to left hand unit. 5 6

Office Locations Australia (Melbourne) tel: +61 (3) 9751 5000 Fax: +61 (3) 9755 7566 China (Shanghai) tel: +86 (21) 6276 6509 Fax: +86 (21) 6277 3543 Hong Kong tel: +852 2590 0012 Fax: +852 2516 5648 India (Mumbai) tel: +91 (22) 6683 7000 Fax: +91 (22) 6683 7002 Indonesia tel: +62 (21) 5366 8500 Fax: +61 (21) 5366 8300 Japan tel: +81 (3) 5738 6100 Fax: +81 (3) 5738 6298 Korea tel: +822 554 5935 Fax: +822 554 5739 Macau tel: +853 2875 1820 Fax: +853 2875 1825 Malaysia (Kuala Lumpur) tel: +60 (3) 7628 4300 Fax: +60 (3) 7874 1180 New Zealand tel: +64 (9) 444 6434 Fax: +64 (9) 444 2092 Singapore tel: +65 6748 0202 Fax: +65 6743 4420 Thailand (Bangkok) tel: +66 (2) 717 1260-80 Fax: +66 (2) 717 1325-8 Manufacturing/assembly: Guangzhou and Wuxi, China; Selangor, Malaysia PUBL-7893