Kirby Commander Condensing Unit

Similar documents
Kirby Drop-In Packaged Refrigeration Units

Kirby CO 2 Evaporators

500 EX Fusion Compressor Series

ENTHALPY TD SERIES CONDENSING UNITS. Enthalpy. Semi Hermetic TD Series Condensing Units (Medium / Low Temperature)

ENTHALPY TD SERIES CONDENSING UNITS

Air-Cooled Condensing Units with Compact Screw Compressors

ENTHALPY HERMETIC CONDENSING UNITS

AIR COOLED CONDENSING UNIT

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Condensing Units CUS 15-60

NATURAL REFRIGERANT SYSTEMS

Technical Data Ducted Three Phase Split System Air Conditioner

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

PACKAGED REFRIGERATION CONDENSING UNITS

Optyma Slim Pack Condensing Units

PACKAGED REFRIGERATION CONDENSING UNITS

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Kramersaver Air Cooled Condensing Units

Air Cooled Scroll Chiller / Heat Pump

SUBCRITICAL & TRANSCRITICAL SYSTEMS

WCH5**4. Product Specifications

Commercial High-Efficiency Condensing Units

DROP-IN + PLUG-IN UNITS

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

N4H4. Product Specifications

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

R4H4. Product Specifications

R4H4. Product Specifications

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Call us today! (800)

PattonPak Stream Condensing Units

Remote Air Cooled Condensers C2 Series

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Call us today! (800)

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Evaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series

Call us today! (800)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

horizontal air discharge outdoor discus condensing unit

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

MAC N-407 Air-Cooled Chiller

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

30GN FLOTRONIC II AIR-COOLED CHILLERS

MACH N-407 Heat Pump Air-Cooled Chiller

DANFOSS OPTYMA PLUS INVERTER UNITS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Air-Cooled Condensing Units with Bitzer Compressors

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Danfoss Scroll for Refrigeration MLM / MLZ

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Compact and silent Scroll compressors All-season operation

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Scroll Water Cooled Chiller

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

Screw Water Cooled Chiller SCW210

2-STAGE SEMI-HERMETIC

PAJ3. Product Specifications

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

30GT FLOTRONIC AIR-COOLED CHILLERS

MAC-120HE-03 Air-Cooled Chiller

y Small dimensions. Easy to install in refrigerated counters or cold rooms

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Accumulators - Suction Line

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

LOW PROFILE EVAPORATORS

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Danfoss scroll for refrigeration LLZ013 to low temperature

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Refrigerants and lubricants

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

3-22 HP CONDENSING UNITS Technical Guide

Split System Heat Pump Product Data

R407C. WCS Series 50Hz. Water Cooled Scroll Direct Expansion Chillers Cooling Capacity: 12 to 53 TR (42 to 186 kw)

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Transcription:

Kirby Commander Condensing Unit Quieter, more powerful and with greater endurance 14kW 36kW

Kirby Commander Condensing Unit Front Cover Navy Submarine The stealth submarines of the world have long been potent symbols of naval strike capability, continually evolving to incorporate technological advances to maintain their edge. Incorporating the latest technology, the Kirby Commander Condensing Unit is built smart to deliver superior performance from a compact platform. Innovations such as the latest Dorin H Series compressors ensure ultra-quiet operation and efficiency positioning the Commander ahead of its field. Built smart, compact and tough the Kirby Commander range offers leading performance and efficiency without making a lot of noise. External rotor fan motors and Dorin H series compressors set the standard for smooth quiet operation across a wide application range. Ultimate reliability comes standard when you combine Kirby and Dorin trusted to handle the extremes of our climate. Features Compressors Dorin H34 and H4 compressors from 5.5 to 22HP Reduced Operating noise levels set a new standard Optimised for R404A and R134a with high COP and efficiency 50% capacity control available as an option on all models Suitable for inverter operation from 25 to 65Hz Condenser Optimised Coil Design incorporating Inner Grooved Tube for enhanced heat transfer Proven Ziehl / EBM external rotor fan motors for long life and increased efficiency Fan speed control (standard) Construction Powder coated Galvabond base and condenser casing High efficiency oil separator with Internal float Dual pressure control Liquid line drier and sight glass Separate electrical box Suction and Liquid line connection points located together Operation Ease of installation and service Reduced noise levels Wide operational envelope at high ambient conditions Two year limited warranty Kirby Commander Condensing Units Nomenclature Data Unit Type PC = Indoor Condensing Unit Compressor Type S = Semi-Hermetic Reciprocating PC S XXX LMH A1-2 Power Supply to Compressor Odd Number = Single Phase Even Number = Three Phase Rated Capacity (kw) x 10 R404A at -5ºC SST for LMH Range R134a at -5ºC SST for LM & MH Range eg. 100 = 10 (kw) x 10 Operating Range for Refrigerants L (Low), M (Med), H (High) and Combinations Condenser Type & Variant A = Air-Cooled Number = Sequential for Different Available Condensers 2

Performance Rating Basis 1. CONDENSING UNIT RATINGS ARE AT THE FOLLOWING CONDITIONS Ambient temperature of 30, 35, 40, 43 or 46 C. Liquid entering temperature with inherent subcooling averaging 2 to 3 K. Return vapour temperature of 20 C. Return vapour temperature should never exceed 20 C for any refrigerant. Low temperature applications should be restricted to maximum 20K return vapour superheat. All capacity data based on continuous condenser fan operation without the consideration of fan speed control. 2. THE FOLLOWING FACTORS MAY BE USED WITH SUFFICIENT ACCURACY FOR CAPACITY CORRECTION AS REQUIRED For changed ambient temperature: interpolate as necessary. For changed liquid entering temperature: increase capacity 1% for each 1 C lower liquid temperature. Vice versa for each 1 C higher liquid temperature. For lower return vapour temperature: R22: Disregard - generally marginal. R404A: Use factors below for 10K return vapour superheat. SST -40-30 -20-10 0 10 R404A 0.88 0.89 0.91 0.94 0.97 1 Multiply rated capacity by factor to get capacity at 10K superheat. 3. LIQUID RECEIVER CAPACITY Refrigerant factor for liquid receiver capacity R507: multiply R404A liquid receiver capacity by 1.02. R407C: multiply R22 liquid receiver capacity by 0.96. 4. UNIT INPUT WATTS, MCC (MAXIMUM CONTINUOUS CURRENT) AND RLA (RATED LOAD AMPS) RLA and input watts values are given for the stated load condition based on calorimeter data where possible. Actual values may vary with varying conditions. RLA and input watts are intended as a guide for comparison purposes with other equipment. MCC is intended to be used as a guide for power supply rating, protection setting, and functional settings such as CPR valve. Unit RLA = Compressor RLA + Condenser Fan RLA. Unit MCC = Compressor MCC + Condenser Fan RLA. Unit Input Watts = Compressor Input Watts + Condenser Fan Input Watts. 5. SOUND POWER LEVEL RATINGS SOUND LEVEL DATA MODEL 100% FAN SPEED 60% FAN SPEED LwA LpA 3m LwA LpA 3m PCS146LMHA1-2 81 60.5 75 54.5 PCS158LMA1-2 80.5 60 74 53.5 PCS174LMHA1-2 81 60.5 75.5 55 PCS194LMA2-2 81.5 61 76.5 56 PCS214LMHA1-4 85 64.5 77 56.5 PCS228LMA1-4 85 64.5 77.5 57 PCS258LMHA1-4 85 64.5 77.5 57 PCS273MHA2-4 86.5 66 82 61.5 PCS318LMA1-4 85.5 65 79 58.5 PCS324LMHA1-4 85.5 65 79 58.5 PCS360LMA1-4 86 65.5 80 59.5 PCS391LMHA2-4 86 65.5 80 59.5 Values given are provisional based on compressor manufacturer s data and tested fan data, and are subject to change. Actual levels may vary according to the unit loading and condenser fan speed. Sound Power - Tests were done with a sound intensity meter generally in accordance with the methods of ISO9614.2 at approximately -10 C sst and +45 C sct compressor operating conditions. SOUND PRESSURE AT 3m USING 20.5dB DEDUCTION FROM SOUND POWER - That is at Location 1. Sound Pressure levels in other application environments at a 3 metre distance from the unit can be estimated using the various deductions below. Unit Locations Location 1 Location 2 Location 3 Location 4 Lw - Lp (db(a)) (3m) 20.5 17.5 14.5 11.5 Location 1: Location 2: Location 3: Location 4: LwA: LpA: Unit located with no hard surfaces to reflect the sound (Free field). Unit located with 1 hard surface to reflect the sound. Unit located with 2 hard surfaces to reflect the sound. Unit located with 3 hard surfaces to reflect the sound. Sound power level, db(a). Sound pressure level, db(a). 6. REFRIGERANT CAPACITY OF CONDENSING UNITS Refrigerant capacity correction data is based on compressor capacity data from the manufacturer, and published thermodynamic data from the refrigerant manufacturers. Figures are an average of data for all models, and are given at 32 C ambient condition. Values can be used with sufficient accuracy over a wide range of ambient temperature without further correction. R507: multiply R404A capacity by 1.03 to find R507 capacity data. R507: application limits are the same as for R404A. R407C: the capacity and application limits are the same as for R22. 3

Performance Rating Basis 1. OIL TYPES USED IN KIRBY COMMANDER CONDENSING UNITS All compressors used in Kirby Commander condensing units are charged with PolyolEster (POE) oil. POE oil can be used with HCFC refrigerants, such as R22, and HFC refrigerants, such as R404A, R507, R407C and R134a. Use ONLY POE oil, do NOT mix POE with other oils, when using HFC refrigerants. Use RL32HTOil if the exact oil listed on the compressor is not available 2. RECOMMENDED HIGH/LOW PRESSURE SWITCH SETTING HIGH PRESSURE LIMIT SETTING Kirby Commander condensing units have a maximum operating pressure of 32 Bar(a) set by pressure vessels codes which apply to items such as the liquid receiver. Pressure limiting device can have a maximum setting of 29 Bar(a), = 0.9x32. Lower values are also acceptable in accordance with AS/NZS1677.2:1998. Kirby Commander condensing units have a maximum design condensing temperature of 58 C. When setting the HP control, consideration must be given to the type of refrigerant used and the maximum ambient temperature to ensure compliance with AS/ NZS1677.2 and avoiding nuisance tripping. LOW PRESSURE SAFETY The cut-out points shall be 3-5 K below the minimum design evaporating temperature, the differential shall be no more than 2 Bar depending on the application and compressor. When the units are installed in a very cold ambient, the cut-out pressure shall be lower than the pressure corresponding to the ambient temperature. The cut-out pressure shall be in the positive pressure region. Do not operate compressors in deep vacuum conditions as this can cause electrical failure. Compressors should never be used to evacuate refrigeration or air conditioning systems. 3. REFER TO THE SECTION OF STANDARD & OPTIONAL CONFIGURATIONS FOR INFORMATION ON OPTIONS STANDARD CONFIGURATIONS Crankcase heater Oil separator, liquid receiver, liquid line dryer, sight glass, dual pressure control, motor protection and fan speed control for all units. All electrical controls are wired to terminal strip in electrical enclosure. Note: Fitting the suction accumulator option is recommended for the units in low temperature application. 4. FAN SPEED CONTROL RGE-Z1N4-5 (4A, 1Ph), RGE-Z1Q4-5 (8A, 1Ph) The controller varies the supply voltage to the fan motor from 45% to at least 95% over the proportional condensing pressure band which is factory fixed at 4 bar. The full voltage set point (FVS) is adjustable from 8-28bar, and is set by Heatcraft at 19 Bar for R404A medium temp. By turning the setting screw clockwise, the pressure setting increases. Turn anti-clockwise to decrease the pressure setting. The set point can be seen on the range setting pointer. The cut-off point is defined at 45% supply voltage to the fan motor, at factory setting this is 15±1 Bar depending on actual load and / or power supply. When the condensing pressure reduces to the minimum speed condition, the factory setting of Min Speed on the change-over switch ensures that the fans continue to run at this speed regardless of how low the pressure goes below the minimum. Alternatively, the change-over switch can be set in the field to Cut-Off, in which case the controller will cut power to the fans and the fans will stop. The fans will then restart at low speed when the pressure rises. For details, please refer to the manufacturers product specification. Heatcraft factory setpoint for primary refrigerant R404A is 19 Bar(g) for M/T & 14 Bar(g) for L/T units. Heatcraft Australia recommends 16 Bar(g) for R22, 10 Bar(g) for R134a units. 4

Performance Rating Basis 5. CAPACITY CONTROL FOR DORIN H34 & H4 SERIES COMPRESSORS Dorin H34 & H4 compressors are 4 cylinders with 2 discharge heads. When capacity control is in operation, one discharge head is disabled by blocking the suction gas from entering the cylinders. Due to less refrigerant flow, thus less cooling effect to the electric motor, the running discharge head becomes hotter and the inactive head continually has reciprocating mechanical motion, thus been heating up over time. Hence it is recommended to have the following protection features implemented during capacity control operation. Fit a head cooling fan to reduce the temperature of compressor heads. Limit compressor operating range. Limit compressor continuous operating time to 2-3 hours. Then a 3-5 minutes operation at full capacity is necessary to cool the compressor down before the next capacity control operation. 5

R404A/R507 Low/Medium/High Temperature Dorin Semi-Hermetic Reciprocating Compressors UNIT MODEL PCS146LMHA1-2 PCS158LMA1-2 PCS174LMHA1-2 PCS194LMA1-2 PCS214LMHA1-4 PCS228LMA1-4 PCS258LMHA1-4 PCS318LMA1-4 PCS324LMHA1-4 AMB LT MT HT REC'R CAP. ( C) -45-40 -35-30 -25-20 -15-10 -5 0 5 10 (L) (KG) 30 3170 4260 5440 6840 8500 10450 12660 15080 17660 20360 23190 35 2790 3810 4930 6240 7790 9580 11600 13810 16170 18610 21080 40 3360 4420 5640 7070 8700 10540 12540 14670 16860 18960 10.9 8.9 43 4110 5290 6640 8180 9900 11780 13780 15810 30 3700 4930 6350 7980 9810 11840 14050 16430 35 3300 4440 5750 7230 8910 10760 12770 14900 40 3950 5140 6490 8010 9680 11490 13380 10.9 8.9 43 3660 4780 6040 7470 9040 10720 12460 30 3950 5250 6660 8340 10330 12650 15250 18070 21030 24090 26690 35 3470 4690 6030 7590 9430 11540 13900 16460 19150 21890 24260 40 4140 5400 6850 8530 10430 12560 14850 17260 19690 21830 10.9 8.9 43 3800 5020 6400 7980 9770 11750 13890 16130 18370 30 4570 6040 7750 9710 11920 14380 17100 20110 35 4050 5420 7000 8820 10880 13170 15680 18410 40 4800 6260 7930 9830 11950 14260 16700 10.9 8.9 43 4420 5810 7400 9210 11230 13410 15680 30 4660 6250 8070 10210 12710 15570 18740 22180 25830 29630 32890 35 4120 5620 7310 9280 11560 14150 17030 20160 23490 26950 30000 40 4990 6560 8350 10410 12730 15320 18140 21150 24270 27110 14.5 11.9 43 6110 7800 9720 11880 14290 16930 19750 22650 30 5470 7150 9120 11410 14020 16940 20160 23650 35 4860 6430 8260 10360 12760 15440 18380 21550 40 5710 7390 9320 11500 13940 16600 19450 14.5 11.9 43 5280 6880 8700 10750 13040 15530 18190 30 5570 7520 9740 12300 15240 18610 22420 26680 31350 36340 41410 35 4980 6800 8870 11250 13990 17110 20620 24530 28780 33280 37780 40 6080 8000 10200 12730 15600 18820 22380 26210 30220 34150 24.5 20.0 43 7480 9570 11980 14700 17740 21090 24670 28380 30 7200 9930 13050 16380 19900 23720 28030 33020 35 6470 8900 11690 14720 17990 21570 25570 30060 40 7880 10320 13050 16080 19420 23100 27110 24.5 20.0 43 7260 9500 12060 14940 18130 21620 25330 30 7360 9890 12770 16050 19750 23880 28460 33530 39130 45330 51030 35 6560 8890 11520 14530 17940 21780 26060 30770 35900 41390 46460 40 7890 10270 13010 16140 19690 23660 28020 32670 37460 41880 24.5 20.0 PCS360LMA1-4 PCS361LMHA2-4 PCS391LMA2-4 30 8470 11230 14430 18100 22250 26850 31900 37370 35 7550 10130 13090 16480 20280 24510 29120 34080 40 9030 11750 14850 18320 22160 26340 30790 43 8370 10950 13870 17140 20760 24680 28820 30 8430 11230 14360 17920 22000 26620 31750 37370 43370 49660 56170 35 7530 10160 13080 16400 20180 24450 29180 34300 39690 45160 50400 40 6630 9090 11810 14880 18360 22280 26600 31230 36020 40660 30 9270 12280 15770 19760 24240 29200 34620 40500 35 8250 11060 14280 17960 22080 26640 31610 36930 40 9840 12800 16160 19920 24090 28600 33350 24.5 20.0 24.5 20.0 24.5 20.0 6

R134a Medium/High Temperature Dorin Semi-Hermetic Reciprocating Compressors UNIT MODEL PCS146LMHA1-2 PCS158LMA1-2 PCS174LMHA1-2 PCS194LMA1-2 PCS214LMHA1-4 PCS228LMA1-4 PCS258LMHA1-4 PCS318LMA1-4 PCS324LMHA1-4 PCS360LMA1-4 PCS361LMHA2-4 PCS391LMA2-4 PCS273MHA2-4 AMB LT MT HT REC'R CAP. ( C) -45-40 -35-30 -25-20 -15-10 -5 0 5 10 (L) (KG) 30 3890 5210 6680 8350 10240 12390 14800 17470 35 3580 4860 6270 7860 9680 11730 14020 16560 40 3270 4500 5850 7380 9110 11070 13240 15640 10.9 10.4 46 2910 4080 5360 6810 8450 10280 12320 14570 30 4700 6160 7820 9700 11830 14230 16890 19830 35 4330 5740 7320 9120 11150 13440 15980 18750 40 3960 5310 6830 8540 10470 12650 15070 17670 10.9 10.4 46 3540 4810 6240 7860 9680 11720 13990 16400 30 4740 6280 7990 9920 12110 14580 17330 20370 35 4390 5860 7500 9340 11430 13780 16390 19260 40 4030 5440 7000 8760 10740 12970 15440 18160 10.9 10.4 46 3620 4950 6420 8080 9940 12020 14330 16860 30 5530 7250 9220 11450 13970 16810 19990 23470 35 5090 6750 8640 10770 13190 15900 18920 22220 40 4660 6250 8050 10090 12400 14980 17850 20960 10.9 10.4 46 4160 5670 7370 9300 11470 13900 16590 19480 30 5710 7600 9690 12050 14730 17770 21180 24970 35 5260 7070 9070 11330 13900 16810 20070 23680 40 4820 6540 8450 10610 13070 15840 18950 22390 14.5 13.8 46 4300 5920 7730 9770 12090 14710 17630 20860 30 6860 9000 11420 14150 17230 20720 24640 28880 35 6320 8380 10690 13300 16250 19580 23290 27310 40 5790 7750 9960 12450 15260 18430 21950 25740 14.5 13.8 46 5170 7020 9100 11450 14100 17070 20370 23890 30 6720 9020 11590 14500 17830 21600 25830 30530 35 6200 8400 10850 13630 16800 20390 24410 28860 40 5670 7770 10110 12760 15770 19180 22990 27190 46 5060 7040 9240 11730 14570 17760 21320 25220 30 8920 11640 14710 18170 22060 26430 31270 36530 35 8200 10810 13740 17050 20760 24910 29500 34470 40 7480 9980 12780 15930 19450 23390 27730 32410 46 6650 9010 11650 14610 17920 21600 25640 29980 30 8660 11520 14700 18300 22410 27080 32310 38110 35 8020 10750 13790 17240 21160 25610 30580 36070 40 7370 9990 12890 16180 19910 24140 28850 34030 46 6620 9090 11830 14930 18450 22410 26810 31630 30 10470 13550 17030 20980 25430 30430 35990 42050 35 9670 12620 15950 19710 23940 28690 33950 39670 40 8860 11690 14870 18440 22450 26940 31910 37300 46 7930 10600 13600 16950 20700 24890 29510 34500 30 9830 13130 16830 20990 25720 31050 37020 43580 35 9070 12220 15740 19710 24200 29260 34920 41130 40 8310 11310 14660 18430 22680 27480 32830 38680 46 7420 10250 13390 16920 20900 25380 30360 35790 30 11320 14770 18660 23060 28030 33600 39760 46430 35 10410 13720 17440 21640 26370 31650 37490 43790 40 9510 12670 16220 20220 24700 29710 35220 41150 46 8450 11450 14800 18550 22750 27420 32550 38040 30 10950 14530 18490 22930 27960 33640 40000 46940 35 10160 13590 17370 21620 26420 31820 37830 44390 40 9370 12640 16250 20300 24870 29990 35660 41850 46 8450 11530 14930 18750 23050 27850 33110 38850 7

R22 Medium/High Temperature Dorin Semi-Hermetic Reciprocating Compressors UNIT MODEL PCS146LMHA1-2 PCS158LMA1-2 PCS174LMHA1-2 PCS194LMA1-2 PCS214LMHA1-4 PCS228LMA1-4 PCS258LMHA1-4 PCS318LMA1-4 PCS324LMHA1-4 AMB LT MT HT REC'R CAP. ( C) -45-40 -35-30 -25-20 -15-10 -5 0 5 10 (L) (KG) 30 6460 8100 10000 12210 14750 17620 20840 24410 35 5970 7530 9370 11510 13960 16740 19850 23280 40 5470 6970 8740 10810 13180 15860 18870 22160 10.9 10.3 43 5180 6640 8360 10380 12710 15340 18270 30 7530 9310 11350 13650 16240 35 6950 8650 10600 12820 15310 40 6360 7980 9850 11990 14380 10.9 10.3 43 6000 7580 9410 11490 13820 30 7800 9690 11890 14430 17330 20620 24300 28360 35 7210 9030 11160 13620 16430 19620 23170 27080 40 6620 8370 10430 12810 15540 18610 22040 25790 10.9 10.3 43 6270 7980 9990 12320 15000 18010 21360 30 9100 11270 13780 16670 19940 35 8400 10500 12930 15730 18900 40 7700 9730 12090 14790 17860 10.9 10.3 43 7290 9260 11580 14230 17230 30 9480 11810 14500 17590 21120 25120 29590 34490 35 8760 10990 13580 16560 19970 23830 28140 32860 40 8040 10170 12650 15520 18810 22530 26680 31220 14.5 13.7 43 7610 9680 12100 14900 18120 21760 25810 -- 30 10770 13290 16210 19550 23350 35 9940 12370 15200 18440 22120 40 9110 11450 14190 17330 20900 14.5 13.7 43 8610 10900 13580 16660 20160 30 11710 14600 17970 21880 26340 31370 36970 43120 35 10810 13580 16830 20590 24900 29760 35170 41110 40 9910 12560 15680 19300 23460 28150 33370 39090 24.5 23.2 43 9370 11950 14990 18530 22590 27180 32290 30 14980 18560 22660 27310 32510 35 13810 17230 21160 25630 30630 40 12640 15900 19670 23950 28750 24.5 23.2 43 11940 15100 18770 22940 27630 30 14940 18520 22680 27470 32960 39170 46120 53780 35 13780 17230 21250 25900 31220 37250 43990 51420 40 12610 15940 19820 24330 29490 35330 41860 49050 24.5 23.2 PCS360LMA1-4 PCS361LMHA2-4 PCS391LMA2-4 30 17200 21240 25840 31020 36780 35 15920 19800 24200 29160 34660 40 14650 18350 22560 27290 32550 43 13890 17490 21580 26170 31280 30 17360 21480 26190 31530 37510 44140 51400 59250 35 16080 20020 24530 29640 35360 41700 48650 56150 40 14800 18560 22870 27750 33210 39270 45900 30 18770 23160 28160 33770 39990 35 17360 21570 26350 31710 37660 40 15960 19970 24540 29650 35320 24.5 23.2 24.5 23.2 24.5 23.2 8

Technical Data Electrical Specifications Low/Medium/High Temperature COMPRESSOR CONDENSER UNIT UNIT MODEL DISPL. Volts / Ph MOTOR RLA* LRA MCC INPUT* Volts / Ph RLA MCC LRA RLA INPUT MODEL (m 3 /Hr) (50Hz) TYPE (Amps/Ph) (Watts) (50Hz) (Amps) (Amps/Ph) (Watts) PCS146LMHA1-2 H550CC 22.55 380-420 / 3 Y- DOL 8.1 63 13.5 5810 240/1/50 1.8 17.1 68.4 11.7 6610 PCS174LMHA1-2 H700CC 27.33 380-420 / 3 Y- DOL 10.5 86 17.5 8640 240/1/50 1.8 21.1 91.4 14.1 9440 PCS214LMHA1-4 H750CC 33.47 380-420 / 3 Y- DOL 10.5 86 17.5 8660 240/1/50 2.8 23.1 94.4 16.1 10000 PCS258LMHA1-4 H1000CC 38.65 380-420 / 3 YY- PWS 13.8 109 23 10120 240/1/50 2.8 28.6 117.4 19.4 11460 PCS324LMHA1-4 H1500CC 48.82 380-420 / 3 YY- PWS 20.4 171 34 13140 240/1/50 2.8 39.6 179.4 26 14480 PCS361LMHA2-4 H2000CC 56.95 380-420 / 3 YY- PWS 22.8 177 38 15390 240/1/50 2.8 43.6 185.4 28.4 16730 PCS273MHA2-4 H2200CC 61.9 380-420 / 3 YY- PWS 24 200 40 9280 240/1/50 2.8 43.6 185.4 29.6 10620 PCS158LMA1-2 H550CS 27.33 380-420 / 3 Y- DOL 8.1 63 13.5 4620 240/1/50 1.8 17.1 68.4 11.7 5420 PCS194LMA1-2 H700CS 31.88 380-420 / 3 Y- DOL 10.5 86 17.5 4570 240/1/50 1.8 21.1 91.4 14.1 5370 PCS228LMA1-4 H750CS 38.26 380-420 / 3 Y- DOL 10.5 86 17.5 6620 240/1/50 2.8 23.1 94.4 16.1 7960 PCS318LMA1-4 H1000CS 48.82 380-420 / 3 YY- PWS 15 135 25 8270 240/1/50 2.8 30.6 143.4 20.6 9610 PCS360LMA1-4 H1500CS 56.95 380-420 / 3 YY- PWS 20.4 171 34 9610 240/1/50 2.8 39.6 179.4 26 10950 PCS391LMA2-4 H1600CS 61.92 380-420 / 3 YY- PWS 22.8 177 38 10670 240/1/50 2.8 40.6 179.4 28.4 12010 * Compressor RLA and Input Watts data are taken at -5 C SST / +45 C SCT with nominal refrigerant. * Compressor LRA and MCC data are supplied by compressor manufacturer. Physical Specifications Low/Medium/High Temperature UNIT MODEL CONDENSER FAN QTY. x DIA. AIRFLOW (l/s) REFRIGERANT CONNECTIONS LIQUID (mm) SUCTION (mm) DIMENSIONS (Millimetres) H W D A B BASE TYPE UNIT WEIGHT (Approx. kg) UN- PACKED PCS146LMHA1-2 2 x 450 1940 15.9 28.6 845 1400 900 700 850 A 195 215 PCS174LMHA1-2 2 x 450 2190 15.9 34.9 882 1400 900 700 850 A 205 225 PCS214LMHA1-4 2 x 500 3120 15.9 34.9 981 1400 900 700 850 A 235 250 PCS258LMHA1-4 2 x 500 3400 22.2 34.9 1033 1650 900 580 / 480 850 B 325 345 PCS324LMHA1-4 2 x 500 3245 22.2 41.3 1033 1650 900 580 / 480 850 B 365 390 PCS361LMHA2-4 2 x 500 3245 22.2 41.3 1033 1650 900 580 / 480 850 B 370 395 PCS273MHA2-2 2 x 500 3245 22.2 41.3 1033 1650 900 580 / 480 850 B 370 395 PCS158LMA1-4 2 x 450 2130 15.9 34.9 845 1400 900 700 850 A 190 205 PCS194LMA1-4 2 x 450 2190 15.9 34.9 882 1400 900 700 850 A 205 225 PCS228LMA1-4 2 x 500 3350 15.9 34.9 981 1400 900 700 850 A 125 145 PCS318LMA1-4 2 x 500 3590 22.2 34.9 1033 1650 900 580 / 480 850 B 325 345 PCS360LMA1-4 2 x 500 3400 22.2 41.3 1033 1650 900 580 / 480 850 B 350 370 PCS391LMA2-4 2 x 500 3245 22.2 41.3 1033 1650 900 580 / 480 850 B 370 390 PACKED Ultimate reliability comes standard when you combine Kirby and Dorin trusted to handle the extremes of our climate. 9

Physical Dimensions Base Type A MIN DISTANCE TO WALLS = 600mm D 1400 H W 900 853 350 700 350 Base Type B MIN DISTANCE TO WALLS = 600mm D 1650 H W 900 860 CRS 288 580 CRS 480 CRS 300 10

Configurations Standard Configurations - All Models Dorin H34 and H4 New Generation Semi Hermetic Compressors (13 Models) Inactive Capacity Control Function (50%) Compressor Sump Heater Electrical Motor Protection INT69 Universal - Multi Function Dual Pressure Control Liquid Receiver, Drier and Moisture Indicating Sight Glass Suction and Liquid Line Connections Located Together High Efficiency Oil Separator With Internal Float Latest Generation, Low Noise, External Rotor Fan Motors Pressure Actuated Condenser Fan Speed Control Powder Coated Galvabond Base and Condenser Casing Colorbond Electrical Enclosure with All Components Wired to Din Rail Mounted Cage Clamp Terminals Optional Configurations - By Unit Model Unit Model Full Wiring DOL.* Full Wiring PWS.* Trax Oil / Oil Watch Alarm Trax Oil / Level Control Capacity Control (50%) Head Cooling Fan Suction Accumulator PCS146LMHA1-2 KP529-1F KP529-1 - - KP531-1F KP531-1 KP524-1F KP524-1 KP533-1F KP533-1 KP528-1F KP528-1 KP523-1F KP523-1 PCS174LMHA1-2 KP529-2F KP529-2 - - KP531-1F KP531-1 KP524-2F KP524-2 KP533-1F KP533-1 KP528-1F KP528-1 KP523-2F KP523-2 PCS214LMHA1-2 KP529-3F KP529-3 - - KP531-1F KP531-1 KP524-2F KP524-2 KP533-1F KP533-1 KP528-1F KP528-1 KP523-2F KP523-2 PCS258LMHA1-2 KP529-4F KP529-4 KP530-1F + KP529-4F KP530-1 + KP529-4 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-3F KP523-3 PCS324LMHA1-2 KP529-5F KP529-5 KP530-2 F+ KP529-5F KP530-2 + KP529-5 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-3F KP523-3 PCS361LMHA2-2 KP529-6F KP529-6 KP530-3F + KP529-6F KP530-3 + KP529-6 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-5F KP523-5 PCS273MHA2-2 KP529-6F KP529-6 KP530-3F + KP529-6F KP530-3 + KP529-6 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-4F KP523-4 PCS158LMA1-2 KP529-1F KP529-1 - - KP531-1F KP531-1 KP524-1F KP524-1 KP533-1F KP533-1 KP528-1F KP528-1 KP523-1F KP523-1 PCS194LMA1-2 KP529-2F KP529-2 - - KP531-1F KP531-1 KP524-2F KP524-2 KP533-1F KP533-1 KP528-1F KP528-1 KP523-2F KP523-2 PCS228LMA1-2 KP529-3F KP529-3 - - KP531-1F KP531-1 KP524-2F KP524-2 KP533-1F KP533-1 KP528-1F KP528-1 KP523-2F KP523-2 PCS318LMA1-2 KP529-4F KP529-4 KP530-1F + KP529-4F KP530-1 + KP529-4 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-3F KP523-3 PCS360LMA1-2 KP529-5F KP529-5 KP530-2F + KP529-5F KP530-2 + KP529-5 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-3F KP523-3 PCS391LMA2-2 KP529-6F KP529-6 KP530-3F+ KP529-6F KP530-3 + KP529-6 KP531-1F KP531-1 KP524-3F KP524-3 KP533-1F KP533-1 KP528-2F KP528-2 KP523-6F KP523-6 * Full Wiring includes MP15D Motor Protection, Compressor Contactor and Overload, Circuit Breakers and Main Isolation Switch. 11

australia 13 23 50 heatcraft.com.au new zealand 0800 653 330 heatcraft.co.nz Australia Head Office Heatcraft Australia Pty Ltd, 286 Horsley Road, Milperra NSW 2214 Locked Bag 63, Wetherill Park NSW 1851 (+61) 2 9774 7155 New Zealand Head Office Heatcraft New Zealand Pty Ltd 12 George Bourke Drive, Mt Wellington PO Box 12371 Penrose, Auckland (+64) 9 276 4888 All trade marks and registered trade marks are the property of their respective owners and are used for identification purposes only. Copyright 2015 Heatcraft Australia Pty Limited. Heatcraft Australia continually strive to improve products and processes. We reserve the right to modify product features without notice. Information is correct at time of printing.