Product Tests Report

Similar documents
Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ANSI-ASQ National Accreditation Board/ACLASS

CERTIFICATE OF ACCREDITATION

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

COMITÉ EUROPÉEN DES ASSURANCES

STS Directory Accreditation number: STS 0009

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Vibration tests on a TNAML Luminaire

INTERNATIONAL STANDARD

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

This annex is valid from: to Replaces annex dated: Prolonged until

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

LOVAG TEST INSTRUCTION IEC/EN

S R 8 Circular LED Engine Product Specification

To Whom it May Concern;

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

M7100 Pressure Transducer

Audible warning devices for external alarm

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

3kW 6kW, QUBE Fiber Lasers

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

CERTIFICATE OF ACCREDITATION

EU Declaration of Conformity

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

E-17 Flammable Gas Detection and Alarm System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

DRAFT TANZANIA STANDARD

ETSI TS V1.2.1 ( )

Rules for Classification and Construction Additional Rules and Guidelines

CERTIFICATE OF ACCREDITATION

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

This document is a preview generated by EVS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ENVIRONMENTAL TEST REPORT

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

CERTIFICATE of QUALITY TEST

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Tekniske Data. GreenMatic har svaret. GreenMatic har her samlet nogle tekniske data finder du ikke det du søger så ring og vi skaffer det til dig.

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Thermo-Sealer. Manual Heat Sealer. User Manual

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES

This is a preview - click here to buy the full publication

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

EMC Bayswater Pty Ltd

CERTIFICATE OF ACCREDITATION

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

RE-PR3-E-27 3-Phase Panel Mount 27kW

PROFESSIONAL TESTING (EMI), INC. TESTING CAPABILITIES N. A.W. Grimes Blvd, Suite B, Round Rock, TX

INTERNATIONAL STANDARD

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

Guide Specification Model CTG Automatic Transfer Switch

APR 17 Rev A

Type approval testing of miscellaneous smoke and heat detectors for marine applications

I/A Series 716C 1/16 DIN Temperature Controller

64 Max IR Thermometer

4 & 8-POINT ANNUNCIATORS Instruction Manual

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Transcription:

TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera 2MP HDR 30x IP68 IK10, white MIC-7502-Z30G, PTZ camera 2MP HDR 30x IP68 IK10, gray MIC-ILB-300, Illuminator white-ir light 450m, black MIC-ILW-300, Illuminator white-ir light 450m, white MIC-ILG-300, Illuminator white-ir light 450m, gray MIC-67SUNSHLD, Sunshield for MIC7000 cameras The above-mentioned Bosch product has been tested in accordance and was found to comply with the tests listed below which were carried out during the development phase of the product. Please note that for some tests, test conditions exceed the range that Bosch recommends for effective continuous operation of the camera. Data subject to change without notice. ENVIRONMENTAL TEST BS EN 50130-5:1999 Alarm systems Part 5: Environmental test methods Dry heat Operational IEC 60068-2-2:1974 +A1:1993+ A2:1994 Dry heat Storage IEC 60068-2-2:1974 +A1:1993+ A2:1994 Specific Test Description (Temperatures stated are outside of the camera housing) Temp. +65 C, duration 48 hours Temp. +75 C, duration 4 hours Temp. -45 C, duration 48 hours Cold operational IEC 60068-2-1:1990 +A1:1993+ A2:1994 Cold start test Power off, soak overnight (8 hours) @ -45 C, power up unit, unit must power up & function normally within < 30 minutes. Cold Endurance IEC 60068-2-1:1990 +A1:1993+ A2:1994 Humidity, operational Damp heat, steady state operational IEC 60068-2-30:1988 IEC 60529 Ingress Protection Rating (IPxx) Degrees of protection provided by enclosures (IP Code) [Dust, water ingress (operational)] IEC 60529 Ingress Protection Rating (IPxx) Degrees of protection provided by enclosures (IP Code) [Dust, water ingress (operational)] UL Type rating (similar to NEMA XX) Salt Spray ASTM B117 standard for corrosion resistance External Mechanical Impact (IK Code or Impact rating) Temp -45 C, Duration 4 hours 65 C / 95 %RH for 6 hours, 35 ⁰C/85% RH for 16 hours. Repeat for 5 cycles total. (Camera with mounting adaptor) Dust tight (no dust ingress; complete protection against contact). Water immersion: 24 hours Water depth: 1.8 meters (Camera with MIC-IP67-5PK kit) Dust tight (no dust ingress; complete protection against contact). Water immersion: 30 minutes Water depth: 1 meter Water immersion: 24 hours Water depth: 1.8 meters IP68 IP67 Type 6P (UL) 2000 hrs at 35 C, 95%RH, 5% NaCl IK10- Energy 20J, 5.05 kg steel mass test slug, 50 mm striking radius, drop height Fully functional after all impacts and cycling Page 1 of 5

TO WHOM IT MAY CONCERN Page: 2 of 5 BS EN 50130-5:1999 Alarm systems Part 5: Environmental test methods IEC 62262:2002-02 Vibration sinusoidal operational IEC 60068-2-6:1995 Test Fc: Vibration (sinusoidal), 10m/s² (1.0G) Sinusoidal vibration test IAW MIL-STD-167-1A Specific Test Description (Temperatures stated are outside of the camera housing) 0.4037 m 5 drops per side, impact 5 sides, 25 total impacts. Excludes window. Freq. Range 10-150Hz, 10m/s², 3 axes, sweep rate 1 octave/m 20 sweeps/axis, (1.0g) Exploratory Test 4Hz 25Hz @.01-in single amplitude (.02-in DAD) 1Hz frequency intervals for (15) second dwells. power Variable Frequency Test 4Hz 15Hz @.03- in single amplitude (.06-in DAD) 16Hz 25Hz @.02-in single amplitude (.04- in DAD) 1Hz frequency intervals for (5) minute dwells. Shock operational IEC 60068-2-27:1987 Medium weight Hammer Shock IAW MIL-S-901D Endurance Testing 25Hz @.02-in single amplitude (.04-in DAD) The duration of Endurance Testing is to be 2 hours total, and should be performed at each frequency of prominence identified in the Exploratory and Variable Freq Tests previously performed Shock, Half Sine Impulse, 6ms, 40G Equipment class I, Shock test type A, grade A & B Wind speed (150mph wind tunnel test) (MIC7000 camera only, MIC sunshield, Illuminator and MIC7000 illuminator) Sustained 120-150 mph winds for a 40 minute period without structural damage or loss of video or PTZ function. Sound level (audible noise) < 65 db Transportation Tests (ISTA Procedure 1A) Transportation Tests (ISTA Procedure 1A) ISTA Vibration 14,200 vibratory shocks 2 axis ISTA 36 inches (0.9 m) free fall drop 6 faces of box ADDITIONAL CERTIFICATIONS Functional tests description Description SMPTE 274M-2008 Standard Resolution: 1920x1080 For HD cameras Scan: Progressive 1920 x 1080 Image Sample Structure, Digital Color representation: Representation and Digital Timing Reference complies with ITU-R BT.709 Sequences for Multiple Picture Rates Aspect ratio: 16:9 SMPTE 296M-2001 Standard 1280 x 720 Progressive Image Sample Structure Analogue and Digital Representation and Analogue Interface Conformant with NTCIP protocols 1205, 2301, 1101:1996, 2202:2001, 2101:2001, 2102:2003 Conformant with Open Network Video Interface Forum (ONVIF) Frame rate: 25, 30, 50 and 60 frames/ Resolution: 1280x720 Scan: Progressive Color representation: complies with ITU-R BT.709 Aspect ratio: 16:9 Frame rate: 25, 30, 50 and 60 frames/s Interoperability between network video products, regardless of manufacturer Profile S, Profile G For HD cameras Page 2 of 5

TO WHOM IT MAY CONCERN Page: 3 of 5 ADDITIONAL ENVIRONMENTAL FUNCTIONAL BOSCH TESTS Environmental test methods Specific Test Description MTBF calculation of used components MIC7000 camera only: MTBF 100,000 hours Camera + illuminator: MTBF 80,000 hours Based on: for electronics, MIL-HDBK-217FN1, GB, GC, 25C. HALT (Highly Accelerated Life Test) Ambient Operational Test: +25 C Completed: 11/26/2013 HALT LOL/UOL Voltage Test: 1 - Step mains voltage down from nominal 24VAC by 2 volts every 5 minutes until operational failure and/or destruct failure. Completed: 01/22/2014* 2 - Step mains voltage up from nominal 24 VAC by 2 volts every 5 minutes until operational failure and/or destruct failure. Completed: 01/24/2014* HALT LOL/UOL Temperature Test: 1 - Step temperature down from -40 C by 5 C every 4 hours (minimum) until operational failure and/or destruct failure. Completed: 01/16/2014* 2 - Step temperature up from +40 C by 5 C every 4 hours (minimum) until operational failure and/or destruct failure. Completed: 01/23/2014* HALT Vibration Test: 1 - The DUT is initially vibrated at acceleration level of 5g (rms) for minimum period of at least 10 minutes. After 10 minutes exposure, the DUT is tested operationally and results are recorded. The operating vibration level is then increased by 5g (rms) and the process is repeated for the next step in the test. This sequence is repeated until the DUT fails operational testing or the test level reaches 50g (rms). COLD Start Test: 1 - Set chamber temperature at -45 C. Power removed from test unit for minimum period of 5 hours, then operate the test switch to restore power. The test unit shall complete its start-up sequence and then resume operation. Completed: 11/27/2013 TS 2 Section 2.2.7 Transients, Temperature, Voltage, and Humidity Tests (74 C) TS 2 Section 2.2.8 Vibration 5-30 Hz, 0.5g, Resonant Frequency Search 1 hour endurance test TS 2 Section 2.2.9 Shock (Impact) Test Half Sine Impulse, 11ms, 10g Mil-Std-810-G, 510.5 Sand and Dust Mil-Std-810-G, 506.5 Rain Mil-Std-810-G, 505.5 Solar Radiation Mil-Std-810-G, 501.5 High Temperature Page 3 of 5

TO WHOM IT MAY CONCERN Page: 4 of 5 Environmental test methods Specific Test Description Mil-Std-810-G, 502.5 Low Temperature Mil-Std-810-G, 503.5 Temperature Shock Mil-Std-810-G, 509.5 Salt Fog Mil-Std-810-G, 509.5 Ice/Freezing Rain Approvals Safety, EMC and Environmental Specific Approval Description EMC Europe Directive 2014/30/EU EMC Directive- Electromagnetic compatibility (recast) Text with EEA relevance EN 50130-4:2011 Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder and social alarm systems. EN 61000-3-2:2006 + A2:2009 Mains harmonics Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) EN 61000-3-3:2008 Voltage fluctuations Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection. EN 50121-4:2006 Railway applications EN 55032 Radiated and Conducted Emissions EN 61000-4-2 ESD Susceptibility EN 61000-4-3 Radiated electromagnetic fields EN 61000-4-4 Electrical Fast Transient (EFT) Burst EN 61000-4-5 Levels ±0.5, 1 and 2kV common mode. ± 0.5, 1 and 2kV differential mode. To ALL input / output - and supply-wiring. EN 61000-4-6 Conducted Immunity EN 61000-4-11 Voltage Dip and Short Interruption EMC USA CFR 47 FCC part 15 Class A Mains Voltage Tolerance Test (Brown out supply voltage test) Safety Europe Directive 2014/35/EU Conducted + Radiated Emission based on VERIFICATION procedure Camera fully operational down to 105V (230 V PSU) and 55V (120V PSU). Below this voltage, the camera is not operational. Camera must be power- cycled for the camera block to reset. Low Voltage Directive (LVD) - Electrical equipment designed for use within certain voltage limits Text with EEA relevance IEC 60950-1:2005 (2nd Edition) + A1:2009 EN 60950-1:2006/A11:2009/A1:2010/A12:2011 IEC 62368-1 Safety USA + Canada Information technology equipment Safety Part 1: General requirements Safety standard for Information Technology Equipment and Audio/Video Equipment. Illuminator included Page 4 of 5

TO WHOM IT MAY CONCERN Page: 5 of 5 Specific Approval Description UL 60950-1 (2nd edition dated March 27, 2007; UL listing + cul listing. Information technology equipment Safety revised December 19, 2011) Part 1: General requirements CAN/CSA-C22.2 No.E60950-1 (CSA C22.2 No. 60950-1-07, R2012) Australian AS/NZS CISPR 32 Product market with BOSCH supplier code N663 Illuminator included Environmental Restriction of Hazardous Substances ROHS complaint Illuminator and Prohibited and declarable substances in Manufacturer s declaration database based Illuminator and on N 2580-1 products, components, materials and preparations. IEC 60950-22 Part 1: General requirements Report for camera: US-23589-A2-UL Report for illuminator: US-23566-UL UL 60950-22 EN 60950-22 UL 50E Report for camera: E183863-A34-CB-1 Report for illuminator: E183863-A40-CB-1 Miscellaneous specifications Description Pan and tilt drive output torque Pan = 8.5 N m (6.72 ft lb) Tilt = 15.84 N m (11.62 ft lb) Functional and specification test Functional tests description Camera Performance Illuminator Performance Refer to MIC IP starlight 7000i datasheet. Refer to MIC IP starlight 7000i Illuminator datasheet. The product is produced by a manufacturing organization which is certified on ISO9001 and ISO14001 standards. Page 5 of 5