ENTHALPY HERMETIC CONDENSING UNITS Enthalpy Hermetic Flat Base Condensing Units Standard Fitted Features: Copeland CS Compressors with Oil Sight Glass Crankcase Heater Rotalock Valves HP/LP Control Gomax Flexible Control Hoses Liquid Line Drier & Sight Glass Oil Separator (Pre-charged with POE Oil) Liquid Receiver Galvanised Black Powder Coated Unit Base Supercoat Condenser Treatment (5000 Hour Salt Spray Test) ebmpapst Condenser Fans Saginomiya Condenser Fan Speed Controller (Not available on CS10100A1 Units) 3PH Contactor & Electronic Motor Protection Relay Phase Loss & Phase Imbalance Protection Pre - Wired Back to Junction Box 1.22mm (18G) Interconnecting Copper Pipe Work Nitrogen Holding Charge Options Suction Accumulator (Not available on CS10100A1 Units) Unit Weather Cover (knockdown form) A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 32
ENTHALPY HERMETIC CONDENSING UNITS R404a (R507) Hermetic Flat Base Condensing Units H/P (Nominal) Displ cm³/r Ambient Temp ºC Refrigeration Capacity Watts Evaporating Temperature ºC -30-25 -20-15 -10-5 0 CS10100A1 (Single Phase) CS14260A1 (Single Phase) CS14260A3 CS18260A1 (Single Phase) CS18260A3 CS20260A4503 CS2736053 1.30 38.1 2.00 48.6 2.50 61.4 3.00 74.3 3.50 92.4 32 - - - 2275 2843 3470 4142 38 - - - 1897 2402 2932 3503 43 - - - 1588 2046 2523 3033 32 1418 1951 2601 3320 4115 4931 5761 38 1171 1648 2230 2873 3562 4279 4987 43 969 1399 1921 2498 3114 3744 4360 32 1606 2277 3086 3984 4967 5977 7003 38 1325 1885 2588 3377 4258 5170 6098 43 1124 1590 2197 2897 3681 4503 5336 32 1939 2757 3291 4530 5622 6904 8050 38 1475 2233 2997 3847 4777 5879 6881 43 1088 1803 2501 3246 4111 5107 5996 32 2500 3447 4587 5862 7273 8770 10294 38 2005 2837 3848 4982 6238 7570 8935 43 1629 2367 3268 4274 5403 6594 7814 CS3336053 4.00 106.2 32 3054 4159 5360 6713 8227 9955 11815 38 2517 3466 4507 5697 7052 8597 10299 43 2088 2907 3813 4865 6082 7459 9048 Nominal ratings should be used as a guide, based on 18 degree Celsius return vapour and inherent liquid subcooling. Note: Note: Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing. Standard Fitted Features: Copeland Compressor with Oil Sight Glass Crankcase Heater Rotalock Valves HP/LP Control Gomax Flexible Control Hoses Liquid Line Drier & Sight Glass Oil Separator (Pre-charged with POE Oil) Liquid Receiver Galvanised Black Powder Coated Unit Base Supercoat Condenser Treatment (5000 Hour Salt Spray Test) ebmpapst Condenser Fan - Single Phase Saginomiya Condenser Fan Speed Controller (Not available on CS10100A1 Units) 3PH Contactor & Electronic Motor Protection Relay Phase Loss & Phase Imbalance Protection Pre - Wired Back to Junction Box Nitrogen Holding Charge Options: Suction Accumulator (factory fitted) (Not available on CS10100A1 Units) Unit Weatherproof Cover (knockdown form) Unit Prices without Suction Accumulator CS10100A1 $3,984.90 CS14260A1 $4,686.21 CS14260A3 $4,811.61 CS18260A1 $4,795.53 CS18260A3 $5,133.36 CS20260A4503 $5,268.75 CS2736053 $6,325.26 CS3336053 $6,589.86 Unit Prices with Suction Accumulator Fitted CS14260A1ACC $4,948.82 CS14260A3ACC $5,110.42 CS18260A1ACC $5,093.93 CS18260A3ACC $5,542.55 CS20260A4503ACC $5,677.97 CS2736053ACC $6,734.47 CS3336053ACC $6,999.07 A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 33
ENTHALPY HERMETIC CONDENSING UNITS R134a Hermetic Flat Base Condensing Units H/P (Nominal) Displ cm³/r Ambient Temp ºC Refrigeration Capacity Watts Evaporating Temperature ºC -15-10 -5 0 +5 +10 CS10100A1 (Single Phase) CS14260A1 (Single Phase) CS14260A3 CS18260A1 (Single Phase) CS18260A3 CS20260A4503 CS2736053 1.30 38.1 2.00 48.6 2.50 61.4 3.00 74.3 3.50 92.4 32 1322 1763 2187 2734 3309 4037 38 1103 1493 1851 2315 2804 3421 43 924 1270 1591 2002 2423 2956 32 1926 2551 3106 4032 4878 5951 38 1666 2208 2979 3291 3982 4858 43 1449 1930 2358 2877 3482 4248 32 2310 3078 3765 4622 5592 6822 38 1958 2639 3257 4024 4869 5941 43 1680 2282 2836 3521 4261 5198 32 2627 3485 4349 5313 6431 7846 38 2231 2961 3703 4541 5495 6703 43 1882 2548 3217 3957 4788 5841 32 3399 4509 5525 6794 8220 10029 38 2889 3867 4769 5897 7135 8705 43 2478 3349 4154 5157 6240 7613 CS3336053 4.00 106.2 32 3893 5100 6271 7797 9435 11510 38 3304 4372 5416 6797 8224 10024 43 2821 3770 4699 5971 7225 8815 Nominal ratings should be used as a guide, based on 18 degree Celsius return vapour and inherent liquid subcooling. Fan speed controller will require to be adjusted to suit R134a refrigerant at time of commissioning. Note: Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing. Standard Fitted Features: Copeland Compressor with Oil Sight Glass Crankcase Heater Rotalock Valves HP/LP Control Gomax Flexible Control Hoses Liquid Line Drier & Sight Glass Oil Separator (Pre-charged with POE Oil) Liquid Receiver Galvanised Black Powder Coated Unit Base Supercoat Condenser Treatment (5000 Hour Salt Spray Test) ebmpapst Condenser Fan - Single Phase Saginomiya Condenser Fan Speed Controller (Not available on CS10100A1 Units) 3PH Contactor & Electronic Motor Protection Relay Phase Loss & Phase Imbalance Protection Pre - Wired Back to Junction Box Nitrogen Holding Charge Options: Suction Accumulator (factory fitted) (Not available on CS10100A1 Units) Unit Weatherproof Cover (knockdown form) Unit Prices without Suction Accumulator CS10100A1 $3,984.90 CS14260A1 $4,686.21 CS14260A3 $4,811.61 CS18260A1 $4,795.53 CS18260A3 $5,133.36 CS20260A4503 $5,268.75 CS2736053 $6,325.26 CS3336053 $6,589.86 Unit Prices with Suction Accumulator Fitted CS14260A1ACC $4,948.82 CS14260A3ACC $5,110.42 CS18260A1ACC $5,093.93 CS18260A3ACC $5,542.55 CS20260A4503ACC $5,677.97 CS2736053ACC $6,734.47 CS3336053ACC $6,999.07 A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 34
ENTHALPY HERMETIC CONDENSING UNITS Hermetic Flat Base Unit Optional Extras CS Unit Series Optional Extras Weatherproof Cover only Suit Unit Model Cover Part No Weights (kg) WCAR22 18.0 CS10100A1 $537.08 WCAR26 28.0 CS14260A1 $724.50 WCAR26 28.0 CS14260A3 $724.50 WCAR26 28.0 CS18260A1 $724.50 WCAR26 28.0 CS18260A3 $724.50 WCAR26 28.0 CS20260A4503 $724.50 WCAR36 36.0 CS2736053 $734.58 WCAR36 36.0 CS3336053 $734.58 Weatherproof Cover (Knockdown Form) Hermetic Flat Base Unit Specifications & Dimensions CS Unit Series R134a, R404a (R507) Model Dimensions Connections mm Weight Inches Kg Depth Width Height Suction Liquid CS10100A1 770 600 475 75 14.2 1Phase CS14260A1 770 820 675 98 17.5 CS14260A3 770 820 675 98 3Phase 6.6 1/2 CS18260A1 770 820 675 98 3/4 1Phase 19.1 CS18260A3 770 820 675 98 CS20260A4503 770 820 675 98 7.1 3Phase CS2736053 850 1075 725 133 11.8 5/8 CS3336053 850 1075 725 135 7/8 13.8 Compressor Fan Motor Receiver *MCC @ 90% FLA Voltage (Max. Voltage (R404a) Amps Amps) KG 230v 1 Phase 50Hz Note: Internal crankcase heaters 240/480/600volts 40 watts. *MCC = maximum continuous current, RLA = MCC 1.4 (Copeland advises use RLA for contactor selection) 6.6 0.58 0.73 1.55 4.29 Dimension Drawing C A 8.10 B A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 35
ENTHALPY HERMETIC CONDENSING UNITS Hermetic Flat Base Units Dimensions Drawing A Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Fan Speed Controller 5 Electrical Box 6 HP/LP (mounted on top of elect. box) 7 Condenser 8 Condenser Fan Assy. Drawing B Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Fan Speed Controller 5 Electrical Box 6 HP/LP (mounted on top of elect. box) 7 Condenser 8 Condenser Fan Assy. A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 36
ENTHALPY HERMETIC CONDENSING UNITS Hermetic Flat Base Units Dimensions Drawing C 425 Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Electrical Box 5 HP/LP (mounted on top of elect box) 6 Condenser 7 Condenser Fan Assy. CS10100A1 Wiring Diagram A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 37
ENTHALPY HERMETIC CONDENSING UNITS Hermetic Flat Base Unit Wiring Diagrams A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 38
ENTHALPY HERMETIC CONDENSING UNITS CS Unit Series R134a, R404a (R507) Part Description Hermetic Flat Base Units Spare Parts Model CS10100A1 CS14260A1 CS14260A3 CS18260A1 Compressor CS10K6EPFJ595 CS14K6EPFJ595 CS14K6ETFD595 CS18K6EPFJ595 Fan Motor S4E350AP0648 S4E400AP0244 S4E400AP0244 S4E400AP0244 Speed Controller N/A RGEZ1N45MF RGEZ1N45MF RGEZ1N45MF HP/LP DNSD306X DNSD306X DNSD306X DNSD306X Compressor Contactor N/A N/A MC12B240V N/A Thermal Overload Block N/A N/A GMP223P22A N/A Control Fuse Holder N/A N/A CMS101 N/A Fuse N/A N/A 10G10 N/A Oil Separator NS1004 NS1004L NS1004L NS1004L Liquid Receiver 1300134B 1300134B 1300134B 1300134B Suction Service Valve 2605122030 2605122030 2605122030 2605122030 Suction Valve Gasket 020002802 020002802 020002802 020002802 Discharge Service Valve N/A 2605081620 2605081620 2605081620 Discharge Valve Gasket N/A 020002800 020002800 020002800 Receiver Outlet Valve 2605081620 2605081620 2605081620 2605081620 Receiver Valve Gasket 020002800 020002800 020002800 020002800 Liquid Drier & Sight glass CSG084S (combo) CSG084S (combo) CSG084S (combo) CSG084S (combo) Electrical Box 861656 861656 861656 861656 Optional Fitted Item: Suction Accumulator N/A PA5083157C PA5083157C PA5083157C CS Unit Series R134a, R404a (R507) cont d Part Description Model CS18260A3 CS20260A4503 CS2736053 CS3336053 Compressor CS18K6ETFD595 CS20K6ETFD595 CS27K6ETFD595 CS33K6ETFD595 Fan Motor S4E400AP0244 S4E450AU0337 S4E450AU0337 S4E450AU0337 Speed Controller RGEZ1N45MF RGEZ1N45MF RGEZ1N45MF RGEZ1N45MF HP/LP DNSD306X DNSD306X DNSD306X DNSD306X Compressor Contactor MC12B240V MC12B240V MC12B240V MC12B240V Thermal Overload Block GMP223P22A GMP223P22A GMP223P22A GMP223P22A Control Fuse Holder CMS101 CMS101 CMS101 CMS101 Fuse 10G10 10G10 10G10 10G10 Oil Separator NS1004L NS1004L NS1005 NS1005 Liquid Receiver 1300134B 1300134B 1320315A 1320315A Suction Service Valve 2605122030 2605122030 2605122030 2605142030 Suction Valve Gasket 020002802 020002802 020002802 020002802 Discharge Service Valve 2605081620 2605081620 2605101620 2605101620 Discharge Valve Gasket 020002800 020002800 020002800 020002800 Receiver Outlet Valve 2605081620 2605081620 2605101620 2605101620 Receiver Valve Gasket 020002800 020002800 020002800 020002800 Liquid Drier & Sight glass CSG084S (combo) CSG084S (combo) CSG165S (combo) CSG165S (combo) Electrical Box 861656 861656 861656 861656 Optional Fitted Item: Suction Accumulator PA5083157C PA5083157C PA5083157C PA5083157C A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 39
Enthalpy Semi Hermetic Flat Base Condensing Units Standard Features Bitzer Ecoline Compressor with Oil Sight Glass Crankcase Heater Service Shut Off Valves HP/LP Control Gomax Flexible Control Hoses Liquid Line Drier & Sight Glass Oil Separator (Pre-charged with POE Oil) Liquid Receiver Galvanised Black Powder Coated Unit Base Supercoat Condenser Treatment (5000 Hour Salt Spray Test) Discharge Vibration Eliminator ebmpapst Condenser Fans Single Phase Saginomiya Condenser Fan Speed Controller 3PH Contactor & Electronic Motor Protection Relay Phase Loss & Phase Imbalance Protection Pre - Wired Back to Junction Box Nitrogen Holding Charge Options: Suction Accumulator (factory fitted) (Not available on 2JES07Y1003) Unit Weatherproof Cover (knockdown form) A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 40
R404a (R507) Semi Hermetic Flat Base Condensing Units H/P (Nominal) Displ m³/h Ambient Temp ºC Refrigeration Capacity Watts Evaporating Temperature ºC -40-35 -30-25 -20-15 -10-5 0 +5 32 560 809 1097 1427 1799 2217 2682 3191 3745 4342 2JES07Y1003 3/4 5.21 38 452 681 945 1246 1588 1970 2393 2857 3360 3901 43 367 578 822 1101 1415 1768 2158 2583 3043-32 954 1318 1740 2224 2775 3395 4088 4855 5697 6613 2GES2Y2603 1.5 7.58 38 809 1141 1528 1970 2474 3041 3673 4371 5135 5965 43 691 999 1356 1765 2229 2752 3334 3975 4674 5430 32 1145 1596 2116 2711 3383 4136 4971 5884 6876 7946 2FES3Y260453 1.8 9.54 38 966 1377 1852 2394 3004 3686 4440 5263 6155 7111 43 823 1202 1640 2137 2696 3320 4007 4756 5562-32 1834 2519 3308 4208 5225 6357 7608 8979 10459 12046 2DES3Y3603 3.0 13.4 38 1575 2202 2921 3742 4665 5692 6824 8059 9388 10805 43 1352 1929 2591 3344 4189 5128 6160 7281 8485-32 2366 3204 4169 5267 6508 7890 9418 11092 12904 14847 2CES4Y5203 4.0 16.2 38 2059 2826 3708 4710 5837 7090 8473 9982 11607 13343 43 1793 2500 3311 4231 5264 6410 7670 9040 10513-32 3196 4270 5548 7043 8767 10729 12931 15375 18057 20960 4EES6Y8603* 5.5 22.7 38 2816 3795 4958 6317 7881 9658 11647 13848 16253 18846 43 2495 3393 4460 5705 7136 8757 10567 12565 14739-32 3968 5268 6809 8608 10685 13051 15715 18686 21965 25541 4DES7Y11003* 7.5 26.8 38 3518 4702 6107 7748 9642 11797 14221 16918 19885 23108 43 3142 4228 5520 7028 8767 10744 12965 15429 18133-32 4622 6174 7999 10118 12547 15305 18393 21816 25568 29635 4CES9Y11003* 9.0 32.5 38 4058 5470 7136 9075 11301 13826 16650 19775 23184 26862 43 3607 4902 6436 8223 10275 12601 15199 18067 - - Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling. Shaded areas require additional cooling &/or return vapour limitations contact Australia for further information. * 4 Cylinder Compressors are supplied with one head prepared for capacity control contact Australia for further information. Note: Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing (do not use this option if unit is operating in the shaded area envelope which requires additional cooling) Unit Prices without Suction Accumulator Unit Prices with Suction Accumulator Fitted 2JES07Y1003 $5,952.57 Not available for 2JES07Y1003 unit N/A 2GES2Y2603 $6446.85 2GES2Y2603ACC $6839.25 2FES3Y260453 $6,704.70 2FES3Y260453ACC $6918.48 2DES3Y3603 $8,627.13 2DES3Y3603ACC $8,971.80 2CES4Y5203 $8,987.73 2CES4Y5203ACC $10,470.78 4EES6Y8603 $12,568.44 4EES6Y8603ACC $13,382.40 4DES7Y11003 $13,416.51 4DES7Y11003ACC $13,834.77 4CES9Y11003 $13,861.65 4CES9Y11003ACC $14,980.98 A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 41
R134a - Semi Hermetic Flat Base Condensing Units H/P (Nominal) Displ m³/h Ambient Temp ºC Refrigeration Capacity Watts Evaporating Temperature ºC -25-20 -15-10 -5 0 +5 +10 32 577 839 1144 1498 1904 2369 2892 3477 2JES07Y1003 3/4 5.21 38 500 748 1038 1373 1758 2197 2690 3241 43 443 680 956 1276 1643 2060 2529 3050 32 1142 1527 1976 2497 3096 3780 4556 5429 2GES2Y2603 1.5 7.58 38 1031 1395 1819 2311 2876 3521 4252 5073 43 940 1286 1689 2157 2695 3307 4000 4779 32 1427 1906 2465 3109 3846 4684 5625 6671 2FES3Y260453 1.8 9.54 38 1267 1714 2236 2837 3526 4307 5184 6160 43 1141 1563 2054 2621 3269 4005 4830 5747 32 2067 2773 3603 4569 5679 6940 8361 9943 2DES3Y3603 3.0 13.4 38 1869 2528 3303 4205 5241 6417 7740 9212 43 1706 2327 3057 3906 4879 5984 7226 8607 32 2605 3467 4480 5658 7010 8551 10284 12216 2CES4Y5203 4.0 16.2 38 2375 3180 4127 5227 6490 7927 9541 11339 43 2187 2946 3838 4873 6062 7411 8928 10614 32 3743 4889 6246 7835 9672 11774 14154 16822 4EES6Y8603* 5.5 22.7 38 3394 4465 5732 7215 8928 10886 13101 15580 43 3105 4113 5307 6702 8313 10153 12231 14554 32 4188 5548 7182 9116 11376 13982 16955 20306 4DES7Y11003* 7.5 26.8 38 3794 5061 6581 8381 10482 12904 15661 18767 43 3461 4649 6077 7766 9736 12006 14588 17491 32 5229 6856 8800 11089 13744 16785 20223 24065 4CES9Y11003* 9.0 32.5 38 4772 6288 8097 10226 12695 15518 18706 22263 43 4384 5808 7508 9506 11820 14465 17447 20767 Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling Shaded areas require additional cooling &/or return vapour limitations contact Australia for further information. * 4 Cylinder Compressors are supplied with one head prepared for capacity control contact Australia for further information. Fan speed controller will require to be adjusted to suit R134a refrigerant at time of commissioning. Note: Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing (do not use this option if unit is operating in the shaded area envelope which requires additional cooling) Unit Prices without Suction Accumulator Unit Prices with Suction Accumulator Fitted 2JES07Y1003 $5,952.57 Not available for 2JES07Y1003 unit N/A 2GES2Y2603 $6446.85 2GES2Y2603ACC $6839.25 2FES3Y260453 $6,704.70 2FES3Y260453ACC $6918.48 2DES3Y3603 $8,627.13 2DES3Y3603ACC $8,971.80 2CES4Y5203 $8,987.73 2CES4Y5203ACC $10,470.78 4EES6Y8603 $12,568.44 4EES6Y8603ACC $13,382.40 4DES7Y11003 $13,416.51 4DES7Y11003ACC $13,834.77 4CES9Y11003 $13,861.65 4CES9Y11003ACC $14,980.98 A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 42
Semi-Hermetic Flat Base Units Optional Extras Optional Extras Weatherproof Covers Weatherproof Cover only Suit Unit Model Cover Part No Weights (kg) WCAR22 18.0 2JES07Y1003 $537.08 WCAR26 28.0 2GES2Y2603 $724.50 WCAR26 28.0 2FES3Y260453 $724.50 WCAR36 36.0 2DES3Y3603 $734.58 WCAR36 36.0 2CES4Y5203 $734.58 WCAR72 62.0 4EES6Y8603 $830.32 WCAR72 62.0 4DES7Y11003 $830.32 WCAR72 62.0 4CES9Y11003 $830.32 Semi-Hermetic Flat Base Unit Specifications & Dimensions Semi Hermetic Unit Series R404a (R507), R134a Model 2JES07Y1003 Dimensions Connections mm Weight Inches (mm) Kg Depth Width Height Suction Liquid 600 475 92 5/8 1/2 Compressor Fan Motor(s) Receiver MOC @ 90% FLA Voltage (Max. Voltage (R404a) Amps Amps) KG 2GES2Y2603 770 113 5/8 1/2 5.0 0.73 820 675 2FES3Y260453 114 5/8 1/2 D.O.L. 6.1 1.55 2DES3Y3603 175 7/8 5/8 380-8.6 230V 1.55 850 1075 725 400V 1Phase 2CES4Y5203 180 7/8 5/8 3Phase 10.0 50Hz 3.0 4EES6Y8603 315 1-1/8 5/8 50Hz 13.6 2x 1.55 4DES7Y11003 1100 1480 970 325 1-1/8 5/8 16.5 2x 3.0 4CES9Y11003 327 1-1/8 5/8 20.2 2x 3.0 Note: Crankcase Heaters are Internal PTC self-regulating 230 volts. MOC = maximum operating current 3.7 0.58 4.29 Dimension Drawing A B 8.10 C 12.0 D A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 43
Semi-Hermetic Flat Base Unit Dimensions Drawing A Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Fan Speed Controller 5 Electrical Box 6 HP/LP 7 Condenser 8 Condenser Fan Assembly Drawing B Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Fan Speed Controller 5 Electrical Box 6 HP/LP 7 Condenser 8 Condenser Fan Assembly 9 Suction Accumulator (Optional) A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 44
Semi-Hermetic Flat Base Unit Dimensions (cont d) Drawing C Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Fan Speed Controller 5 Electrical Box 6 HP/LP 7 Condenser 8 Condenser Fan Assembly 9 Suction Accumulator (Optional) Drawing D Legend No Description 1 Oil Separator 2 Liquid Receiver 3 Compressor 4 Fan Speed Controller 5 Electrical Box 6 HP/LP 7 Condenser 8 Condenser Fan Assemblies 9 Suction Accumulator (Optional) A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 45
Semi-Hermetic Flat Base Unit Wiring Diagrams A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 46
Semi-Hermetic Flat Base Unit Wiring Diagrams (cont d) A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 47
Semi Hermetic Unit Series R404a (R507), R134a Part Description Semi-Hermetic Flat Base Units Spare Parts Model 2JES07Y1003 2GES2Y2603 2FES3Y260453 2DES3Y3603 Compressor - Bitzer 2JES07Y 2GES2Y 2FES3Y 2DES3Y ebm Fan Motor S4E350AP0648 (x1) S4E400AP0244 (x1) S4E450AU0337 (x1) S4E450AU0337 (x1) Speed Controller RGEZ1N45MF RGEZ1N45MF RGEZ1N45MF RGEZ1N45MF HP/LP DNSD306X DNSD306X DNSD306X DNSD306X Compressor Contactor MC12B240V MC12B240V MC12B240V MC12B240V Thermal Overload Block GMP223P5A GMP223P22A GMP223P22A GMP223P22A Control/Fan Fuse Holder CMS101 CMS101 CMS101 CMS101 Fuse 10G10 10G10 10G10 10G10 Oil Separator NS1004 NS1004L NS1004L NS1005 Liquid Receiver 1300134B 1300134B 1300134B 1320315A Receiver Outlet Valve 2605081620 2605081620 2605081620 2605101620 Receiver Valve Gasket 020002800 020002800 020002800 020002800 Liquid Drier & Sight Glass CSG084S (combo) CSG084S (combo) CSG084S (combo) CSG165S (combo) Electrical Box 861656 861656 861656 861656 Optional: Suction Accumulator Not Available PA5083116C PA5083116C PA5083157C Semi Hermetic Unit Series R404a (R507), R134a cont d Part Description Model 2CES4Y5203 4EES6Y8603 4DES7Y11003 4CES9Y11003 Compressor - Bitzer 2CES4Y 4EES6Y 4DES7Y 4CES9Y ebm Fan Motor S4E500AM0301 (x1) S4E450AU0337 (x2) S4E500AM0301 (x2) S4E500AM0301 (x2) Speed Controller RGEZ1Q45MF RGEZ1Q45MF RGEZ1Q45MF RGEZ1Q45MF HP/LP DNSD306X DNSD306X DNSD306X DNSD306X Compressor Contactor MC12B240V MC22B240V MC22B240V MC32A240V Thermal Overload Block GMP223P22A GMP223P22A GMP223P22A GMP403P40A Control Fuse Holder CMS101 CMS101 CMS101 CMS101 Control Fuse 10G10 10G10 10G10 10G10 Fan Fuse Holder N/A CMS101 CMS101 CMS101 Fan Fuse N/A 10G16 10G16 10G16 Oil Separator NS1005 NS1007 NS1007 NS1007 Liquid Receiver 1320315A 1320620A 1320620A 1320620A Receiver Outlet Valve 2605101620 2605101620 2605101620 2605101620 Receiver Valve Gasket 020002800 020002800 020002800 020002800 Liquid Drier & Sight Glass CSG165S (combo) CSG165S (combo) CSG165S (combo) CSG165S (combo) Electrical Box 861656 AIR50650 AIR50650 AIR50650 Optional: Suction Accumulator 1010853P 1010853P 1010854P 1010854P A.B.N. 95 008 761 573 EFFECTIVE MARCH 2014 48