SERVICE MANUAL. Room Air Conditioner

Similar documents
Room Air Conditioner Service and Parts Manual

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Room Air Conditioner Service and Parts Manual

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

Window Y9USC/E 09 / 12 / 18 B5R

Room Air Conditioner Service and Parts Manual

Thru-the-Wall Series

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

SERVICE MANUAL CAUTION

Product Information and Technical Guide

Thru-the-Wall Series

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual

FLOOR CONSOLE / UNDER CEILING DUAL type

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation

YDT1/T (0) SERVICE MANUAL MIDEA DEHUMIDIFIER T1 SERIES T2 SERIES

Room Air Conditioner SERVICE MANUAL MODELS: LW website CAUTION

LG Room Air Conditioner

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

HEAT CONTROLLER, INC.

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

LG Room Air Conditioner

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

TECHNICAL DATA & SERVICE MANUAL

The school s metal push-out windows were assessed and nothing of concern was noted.

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CASSETTE type INVERTER MULTI AIR CONDITIONER

Product Information and Technical Guide

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

WALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )

Service Manual & Installation Manual

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

PBS observed paint chips in the garden, which is located approximately six to 10 feet from painted surfaces that were in intact condition.

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E

HEAT CONTROLLER, INC.

TECHNICAL DATA & SERVICE MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

SERVICE MANUAL OFFICE PRO 18 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00014EB

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

Display Cases Deli Cases Service Manual

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Mobile Type Air Conditioner

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

EVAPORATIVE AIR COOLER SERVICE MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WineZone Ceiling Mount Ductless Split 15

AC-12200E Portable Air Conditioner

Portable Air Conditioner

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT. DocID: 00G00025E

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

10,000 BTU PORTABLE ROOM AIR CONDITIONER

Thank you for selecting LENNOX air conditioners.

Installation Instructions

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

- 1 - Updated on 18 March, 2010

TECHNICAL DATA & SERVICE MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TABLE OF CONTENTS FOR YOUR SAFETY

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

P MODEL AIR CONDITIONER

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Transcription:

SERVICE MANUAL Room Air Conditioner MODELS AF-S60FX AF-R80FX AF-S80FX AF-S85FX AF-R100FX AF-S100FX AF-R120FX AF-S120FX AF-S125FX In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used. PREFACE SAFETY PRECAUTIONS...i INSULATION RESISTANCE TEST...i CONTENTS CHAPTER 3. TROUBLESHOOTING GUIDE [1] REFRIGERATION CYCLE DIAGRAM...3-1 [2] TROUBLESHOOTING GUIDE...3-1 CHAPTER 1. PRODUCT SPECIFICATION [1] SPECIFICATION... 1-1 [2] WIRING DIAGRAM... 1-10 [3] EXTERNAL DIMENSION... 1-10 REPLACEMENT PARTS LIST CHAPTER 2. MICROCOMPUTER CONTROL SYS- TEM [1] ELECTRONIC CONTROL CIRCUIT DIA- GRAM... 2-1 [2] PRINTED WIRING BOARD... 2-2 Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set. SHARP CORPORATION This document has been published to be used for after sales service only. The contents are subject to change without notice.

AFS120FX PREFACE Service Manual This SERVICE MANUAL provides various servicing information, including the mechanical and electrical parts, etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. SAFETY PRECAUTIONS 1) When servicing the unit, set the POWER SWITCH to OFF and unplug the power cord. 2) Inspect the service cord for damage or wear. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 3) After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards. INSULATION RESISTANCE TEST 1) Unplug the power cord and connect a jumper lead between the two (2) live pins. 2) The grounding conductor (yellow/green) is to be open. 3) Measure the resistance value with an ohm meter between the jumped lead and each exposed metallic part on the equipment at all the positions (except OFF) of the ROTARY SWITCH or POWER SWITCH. 4) The value should be over 1MΩ. i

CHAPTER 1. PRODUCT SPECIFICATION Service Manual AFS120FX [1] SPECIFICATION 1. AF-S60FX Cooling Capacity BTU/h 6000 Moisture Removal Pint/h 1.9 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 4.9 Rated input Watts 560 Power factor % 96 EER BTU/Wh 10.7 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 39R141BD-04P, 570 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5 x 1.3 x 1000 x 1 Tube Refrigerant Volume R-22 (OZ) Factory Charge 12.7 NET DIMENSIONS Width Height Depth Inch (mm) 18.5" (470) x 12.6" (320) x 16.3" (415) Net Weight Lbs 46.3 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.0" (560) x 14.8" (375) x 18.7" (472) Gross Weight Lbs 57.3 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 500/440/386 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 1

2. AF-R80FX Cooling Capacity BTU/h 8000 Moisture Removal Pint/h 2.1 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 7.6 Rated input Watts 820 Power factor % 96 EER BTU/Wh 9.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 39R191CD-05s, 760 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5 x 1.1 x 1000 x 2 Tube Refrigerant Volume R-22 (OZ) Factory Charge 16.9 NET DIMENSIONS Width Height Depth Inch (mm) 18.5" (470) x 12.6" (320) x 16.3" (415) Net Weight Lbs 46.3 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.0" (560) x 14.8" (375) x 18.7" (472) Gross Weight Lbs 50.7 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 700/630/560 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 2

3. AF-S80FX AFS120FX Cooling Capacity BTU/h 8000 Moisture Removal Pint/h 2.1 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 6.8 Rated input Watts 740 Power factor % 94 EER BTU/Wh 10.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 2R11S3R126A6B, 665 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5 x 1.1 x 1000 x 2 Tube Refrigerant Volume R-22 (OZ) Factory Charge 16.9 NET DIMENSIONS Width Height Depth Inch (mm) 18.5" (470) x 12.6" (320) x 16.3" (415) Net Weight Lbs 54.0 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.0" (560) x 14.8" (375) x 18.7" (472) Gross Weight Lbs 61.7 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 700/630/560 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 3

4. AF-S85FX Cooling Capacity BTU/h 8000 Moisture Removal Pint/h 2.1 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 6.8 Rated input Watts 740 Power factor % 94 EER BTU/Wh 10.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 2R11S3R126A6B, 665 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5 x 1.1 x 1000 x 2 Tube Refrigerant Volume R-22 (OZ) Factory Charge 16.9 NET DIMENSIONS Width Height Depth Inch (mm) 18.5" (470) x 12.6" (320) x 16.3" (415) Net Weight Lbs 54.0 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.0" (560) x 14.8" (375) x 18.7" (472) Gross Weight Lbs 61.7 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 700/630/560 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 4

5. AF-R100FX AFS120FX Cooling Capacity BTU/h 10000 Moisture Removal Pint/h 2.5 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 9.3 Rated input Watts 1020 Power factor % 96 EER BTU/Wh 9.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 44R241AG-FES, 950 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5 x 1.3 x 1150 x 2 Tube Refrigerant Volume R-22 (OZ) Factory Charge 19.4 NET DIMENSIONS Width Height Depth Inch (mm) 18.9" (480) x 14.4" (365) x 22.6" (575) Net Weight Lbs 72.7 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.1" (560) x 17.1" (435) x 24.6" (625) Gross Weight Lbs 83.7 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 820/710/610 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 5

6. AF-S100FX Cooling Capacity BTU/h 10000 Moisture Removal Pint/h 2.5 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 8.4 Rated input Watts 920 Power factor % 94 EER BTU/Wh 10.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 2P14S126B1G, 855 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5 x 1.3 x 1150 x 2 Tube Refrigerant Volume R-22 (OZ) Factory Charge 19.4 NET DIMENSIONS Width Height Depth Inch (mm) 18.9" (480) x 14.4" (365) x 22.6" (575) Net Weight Lbs 77.1 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.1" (560) x 17.1" (435) x 24.6" (625) Gross Weight Lbs 88.1 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 820/710/610 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 6

7. AF-R120FX AFS120FX Cooling Capacity BTU/h 12000 Moisture Removal Pint/h 3.4 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 11.1 Rated input Watts 1230 Power factor % 95 EER BTU/Wh 9.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output 44R291AG-FES, 1075 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5x1.1x800x1+2.5x1.1x1000x1+2.5x1.1x1050x2 Tube Refrigerant Volume R-22 (OZ) Factory Charge 26.8 NET DIMENSIONS Width Height Depth Inch (mm) 18.9" (480) x 14.4" (365) x 22.6" (575) Net Weight Lbs 74.9 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.1" (560) x 17.1" (435) x 24.6" (625) Gross Weight Lbs 85.9 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 820/710/610 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 7

8. AF-S120FX Cooling Capacity BTU/h 12000 Moisture Removal Pint/h 3.4 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 10.1 Rated input Watts 1110 Power factor % 93 EER BTU/Wh 10.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output QK164CDB, 1054 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5x1.1x800x1+2.5x1.1x1000x1+2.5x1.1x1050x3 Tube Refrigerant Volume R-22 (OZ) Factory Charge 26.8 NET DIMENSIONS Width Height Depth Inch (mm) 18.9" (480) x 14.4" (365) x 22.6" (575) Net Weight Lbs 77.2 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.1" (560) x 17.1" (435) x 24.6" (625) Gross Weight Lbs 88.2 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 820/710/610 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 8

9. AF-S125FX AFS120FX Cooling Capacity BTU/h 12000 Moisture Removal Pint/h 3.4 Electrical Data Phase Single Rared frequency Hz 60 Rated voltage Volts 115 Rated current Amps 10.1 Rated input Watts 1110 Power factor % 93 EER BTU/Wh 10.8 Compressor Type (Hermetically sealed rotary type) Model, Motor Output QK164CDB, 1054 REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D x Length x Q'ty(mm) Capillary 2.5x1.1x800x1+2.5x1.1x1000x1+2.5x1.1x1050x3 Tube Refrigerant Volume R-22 (OZ) Factory Charge 26.8 NET DIMENSIONS Width Height Depth Inch (mm) 18.9" (480) x 14.4" (365) x 22.6" (575) Net Weight Lbs 77.2 GROSS DIMENSIONS Width Height Depth Inch (mm) 22.1" (560) x 17.1" (435) x 24.6" (625) Gross Weight Lbs 88.2 FAN SYSTEM Indoor side (Evaporator) Centrifugal fan Outdoor side (Condenser) Propeller fan Air Flow rate (Indoor side) CFM High / Med / Low 820/710/610 OTHERS Safety devices Compressor: Over load Fan motor: Internal thermal protector Air filter Polypropylene net Power cord length ft 6.0 Power plug type 125V, 15A 1 9

[2] WIRING DIAGRAM EVAPORATOR SENSOR AMBIENT SENSOR CONTROL BOARD CN1 CN3 CN7 DISPLAY BOARD BLACK CAPACITOR FAN MOTOR BLUE WHITE YELLOW P1 P2 BLUE Y/G RED P3 COMP BLUE BLACK P4 P5 WHITE GREEN L RED COMPRESSOR BLACK OVERLOAD RELAY POWER SUPPLY [3] EXTERNAL DIMENSION Model A (mm) B (mm) C (mm) AF-S60FX AF-S80FX AF-R80FX 470 415 320 AF-S100FX AF-R100FX AF-S120FX AF-R120FX 485 585 365 C A B 1 10

CHAPTER 2. MICROCOMPUTER CONTROL SYSTEM Service Manual AFS120FX [1] ELECTRONIC CONTROL CIRCUIT DIAGRAM 2 1

[2] PRINTED WIRING BOARD 1. Main control PWB 2 2

2. Display control PWB AFS120FX 2 3

AFS120FX CHAPTER 3. TROUBLESHOOTING GUIDE [1] REFRIGERATION CYCLE DIAGRAM Service Manual The figure below is a brief description of the important components and their function in what is called the refrigeration system. This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle. [2] TROUBLESHOOTING GUIDE In general, possible trouble is classified in three kinds. One is called Starting Failure which is caused from an electrical defect, another is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application, and the other is called the Structure Damage. ROOM AIRCONDITIONER VOLTAGE LIMITS: NAMEPLATE RATING MINIMUM MAXIMUM 115V 103V 122V 3 1

1. Fail to start, Fail to start motor AFS120FX Press the POWER button, then thefanbuttononthecontrol panel. Do the lamps light? No Yes Check wiring. Yes Replace the display board. When turning the power on. Is there a beep sound from theunit? No Check circuit breaker and fuse. Check thepowercord. Check the fan capacitor. Check the transform er. Check whether the fan is blocked. Check whether the blower is blocked. Replace the fuse on mainp CB. Replace the main PCB. Check the voltage between P1, P2, P3 on main PCB and N on powercord. Any one of threenovoltage Replace the motor. 2. Abnormal noise Check whether the air-out frame is vibrating or there is something bloc king swing. Yes When operating in FAN ONLY, is therestillsame noise? No Check whether the pipes are vibrating or coming into contact with other pipes or compressor Check thepipe. Rechargerefrigerant. Yes Check whether the noise is from inside t he pipe. Check whether the fan is blocked. Check whether the blower is blocked. Replace the capillary tube. No Check therubberisolator under the compressor. Replace the compressor. Replace the motor. 3 2

3. No/ineffective cooling Wheth er the display panel display oneof the following signal? " " No Yes indicates room temp sensor failure. indicates indoor pipe sensor failure. Indicates the air filter needs to cleaning. Check whether the indoor outlet/inlet of the unit is blocked or the vent. door is open. Yes Wheth er the compressor can st art in cooling mode even if it soonstops? Check whether the outdoor outlet or inlet of the unit is blocked. No Check temperature setting. Check wiring. Check whether the air filter or Evap. or Cond. is dirty. Check compressor capacitor. Check whether the Evap. is frosting andthecompressor stops frequently. Yes Check leakage. Recyc le refrigerant and braze the leakage point. No No voltage Replace the main PCB. Check the speed of motor. Check soft start module (if fitted). Check the voltage between Compressorrelay onmain PCBand N on power cord. Vacuum and recharge. Check thefancapacitor. Replace the compressor. Replace the motor. PROBLEM POSSIBLE CAUSE REMEDY No display on panel or any one of the buttons Transformer (Discharge transformer before testing) Check resistance between the two input/output lines on transformer. Replace the transformer if either of the input/output is open or the transformer is damaged. failure. Remote control failure. Display board or main PCB failure Check the voltage of display board. Replace the display board if it is +5V else replace the main PCB. Battery failure Check the voltage of battery. Replace batteries if the voltage is lower than 2.3V. Stop instantly after startup. Refrigerant The amount of the refrigerant is too much, making the compressor load too big. Recycle and recharge the refrigerant after checking for the reason. Compressor The compressor is seized. Replace after checking for the reason. Fan motor will not run. Transformer (Discharge transformer before testing) Check resistance between the two input/output lines on transformer. Replace the transformer if either of the input/output is open or the transformer is damaged. No power Check voltage at electrical outlet. Correct if none. Power supply cord Check voltage at the power cord terminal on Main PCB. Replace the power cord if none. Wire disconnected or connection loose Connect wire. Refer to wiring diagram for terminal identification. Repair or replace loose terminal. Main PCB failure Select fan speed and Check the voltage on main PCB. Replace the main PCB if no voltage in all three. Capacitor (Discharge capacitor before testing) Test capacitor. Replace if not within +/-10% of manufacture's rating. Replace if shorted, open or damaged. Will not rotate Fan blade hitting shroud or blower hitting scroll. Realign assembly. Check fan motor bearings. Replace the motor if motor shaft do not rotate. 3 3

PROBLEM POSSIBLE CAUSE REMEDY Fan motor noise. Fan Replace the fan if cracked, out of balance, or partially missing. Blower Replace the blower if cracked, out of balance, or partially missing. Loose screws Tighten them. Worn bearings Replace the motor if knocking sounds continue when running or loose, or the motor hums or noise appears to be internal while running. The compressor not to Room temperature sensor Check and replace if the temperature is open or damaged. stop even the room temperature Main PCB Check and replace the main PCB if the relay on PCB is shorted or damaged. has got to the setting temperature. Compressor will not run Voltage Check voltage. Call Supply Authority if not within limits. while fan motor runs. Wiring Check the wire connections, if loose, repair or replace the terminal. If wires are off, refer to wiring diagram for identification, and replace. Check wire locations. If not per wiring diagram, correct. Main PCB failure Check voltage of main PCB. Replace the main PCB if open. Capacitor (Discharge capacitor before testing) Check the capacitor. Replace if not within +/-10% of manufacturers rating. Replace if shorted, open, or damaged. Room temp sensor Check the temperature setting if not at the coolest (in cooling mode) or the warmest (in heating mode). Set it if not. Compressor Check the compressor for open circuit or ground. If open or grounded, replace the compressor. Insufficient cooling. Air filter Clean or replace if restricted. Vent. Door Close if open. Unit undersized Determine if the unit is properly sized for the area to be cooled or heated. Condenser and Evaporator Clean or replace if restricted. Fan motor Check the fan capacitor and replace if not within +/-10% of manufactures rating. Room structure Take proper measures to make the door and windows sealed well if gap is found. Air flow Clean or remove if any barrier is found to block the inlet/outlet wind flow of the unit. Sunlight Add a awning if the condenser is exposed to the sunlight. Less refrigerant Check the tubes for reasons of leakage. Recycle the refrigerant, correct the leakage points and recharge. Capillary tube Regulate the flow if capillary tube and make the evaporating temperature appropriate if the evaporator is frosted. Replace if blocked. Repair joint if leaking. Compressor The inlet and outlet valve of the compressor is damaged, making the low pressure connected with the high pressure. The refrigerating system can not produce high pressure and low pressure. Replace the compressor after checking for the reason. Heat sources Reduce if too many. Excessive noise. Copper tubing Remove the cabinet and carefully rearrange tubing not to contact cabinet, compressor, shroud and barrier. The unit starts and stops Power supply The input power supply voltage is too low. Call an electrician if not within limits. frequently. Main PCB Check and replace the main PCB if the relay on PCB is shorted or damaged. Outdoor temperature When the outdoor temperature is too high, the compressor will protect. No cooling. No power Check the voltage. Call an electrician if no within the limit. Wiring Check the terminals. Repair and correct if loose. Temperature setting Check and adjust the temperature setting. Mode setting Check and adjust the mode setting. Main PCB Check the voltage of main PCB. Replace the main PCB when the unit failure in heating mode. 3 4

MEMO 3 5

REPLACEMENT PARTS LIST AFS120FX MODELS Room Air Conditioner AF-S60FX AF-R100FX AF-R80FX AF-S100FX AF-S80FX AF-R120FX AF-S85FX AF-S120FX AF-S125FX CONTENTS [1] Chassis Lower shutter frame (Small) [2] Electric control system Cabinet and shutter Front panel ass'y (Small) [3] Airflow system Refrigerant system (Small) [4] Accessories (Small) [5] Others (Small) [7] Electric control system Cabinet and shutter Front panel ass'y (Medium) [8] Airflow system Refrigerant system (Medium) [9] Accessories (Medium) [10] Others (Medium) INDEX [6] Chassis Lower shutter frame (Medium) HOW TO ORDER REPLACEMENT PARTS To have your order filled promptly and correctly, please furnish the following information. 1. MODEL NUMBER 2. REF. No. 3. PART NO. 4. DESCRIPTION MARK: SPARE PARTS-DELIVERY SECTION For U.S.A. only Contact your nearest SHARP Parts Distributor to order. For location of SHARP Parts Distributor, Please call Toll-Free; 1-800-BE-SHARP Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for SHARP CORPORATION This document has been published to be used for after sales service only. The contents are subject to change without notice.

[1] Chassis Lower shutter frame (Small) Cabinet and shutter Air flow system Electric control system for manual model for electric model Refrigerant system Front panel assy 1 2 NO. PARTS CODE PRICE NEW MARK PART [1] Chassis Lower shutter frame (Small) 1 LCHS-A487JBTA AZ Chassis[S60FX] 1 LCHS-A494JBTA AZ Chassis[R80FX] 1 LCHS-A496JBTA AZ Chassis[S80FX][S85FX] 2 LANGKA196JBTA AM Lower shutter frame DESCRIPTION 2

[2] Electric control system Cabinet and shutter Front panel ass'y (Small) Electric control system 6 7e 4 3 for electric model 16 17 Cabinet and shutter 8 16 9e 11 10 6 4 12 3 for manual model 24 8 10 23 22 21 20 Front panel assy NO. PARTS CODE PRICE NEW MARK PART DESCRIPTION [2] Electric control system Cabinet and shutter Front panel ass'y (Small) 3 LPLTMA213JBPZ AK Electric part box 4 RC-HZA525JBEZ BA Capacitor[S60FX] 4 RC-HZA540JBZZ BB Capacitor[R80FX][S80FX][S85FX] 6 LBNDKA134JBPZ AD Capacitor clamp! 7e DPWBFA420JBKZ BM Main control board 8 LPLTMA214JBPZ BR Installation board for e-parts! 9e DPWBFA421JBKZ BA Display board 10 HPNLCA879JBFA AM Control box 10 HPNLCA880JBEA AD display panel 11 RH-HXA050JBZZ AM Evaporator temp sensor 12 RH-HXA049JBZZ AM Indoor temp sensor 16 LANGKA195JBFA AD Connection bar to cabinet 17 GCAB-A300JBTA BC Cabinet 20 GWAKPA171JBFA BA Front panel (included in 44) 21 PFILMA207JBEA AG Air filter (included in 44) 22 GWAK-A320JBFA AV Panel frame (included in 44) 23 MLOV-A405JBFA AM Horizontal louver (included in 44) 24 MLOV-A406JBFA AD Vertical louver (included in 44) 24 MLOV-A421JBFA AD Vertical louver B (included in 44) 24 MJNTPA121JBFA AD Louver link (included in 44) 3

[3] Airflow system Refrigerant system (Small) 31 40 39 30 29 27 26 28 36 33 34 25 32 Air flow system Refrigerant system NO. PARTS CODE PRICE NEW MARK PART [3] Airflow system Refrigerant system (Small) DESCRIPTION 25 PKESSA098JBFZ AM Lower fan shell 26 NFANSA047JBFA AY Centrifugal fan 27 PKESSA099JBFZ AN Med fan shell! 28 CMOTLB183JBEZ BQ Fan motor[s60fx]! 28 CMOTLB197JBEZ BR Fan motor[r80fx][s80fx][s85fx] 29 PKESPA110JBFZ AY Rear separating board 30 NFANPA125JBFA AP Propeller fan 31 PKESSA100JBFZ AK Upper fan shell 32 PEVA-A559JBEZ BM Evaporator[S60FX] 32 PEVA-A570JBEZ BN Evaporator[R80FX][S80FX][S85FX] 33 PPIPCH321JB1Z AM Suction pipe[s60fx] 33 PPIPCH394JB1Z AM Suction pipe[r80fx] 33 PPIPCH395JB1Z AL Suction pipe[s80fx][s85fx] 34 PCON-A549JBEZ BN Condenser[S60FX] 34 PCON-A555JBEZ BS Condenser[R80FX] 34 PCON-A559JBEZ BR Condenser[S80FX][S85FX]! 36 PCMPRA476JBEZ BZ Compressor[S60FX]! 36 PCMPRA488JBEZ CB Compressor[R80FX]! 36 PCMPRA489JBEZ CB Compressor[S80FX][S85FX] 39 PPIPCH320JB1Z AN Discharge pipe[s60fx] 39 PPIPCH401JB1Z AP Discharge pipe[r80fx] 39 PPIPCH402JB1Z AM Discharge pipe[s80fx][s85fx] 40 DCPY-A344JBKZ AR Capillary assembly[s60fx] 40 DCPY-A350JBKZ AU Capillary assembly[r80fx][s80fx][s85fx] 4

[4] Accessories (Small) AFS120FX A A-4 A-4 B-1 A-3 A-5 A-5 A-2 B-2 A-8 A-9 A-10 A-6 A-7 A-11 A-1 A-13 A-12 NO. PARTS CODE [4] Accessories (Small) PRICE NEW MARK PART A CFZK-C576JBKZ AZ Accessory part A-1 CRMC-A671JBEZ AU Remote controller A-2 LANGAA042JBFA AK Right shutter frame A-3 LANGAA043JBFA AK Left shutter frame A-4 LANGKA193JBFA AF Shutter locking bar A-5 PPLTPA021JBFA AP Shutter A-6 TCAD-A659JBTZ AD Consummer card A-7 TINSEA412JBTZ AG Operation manual A-8 PSEL-C969JBEZ AF Window sash seal A-9 PSEL-C970JBEZ AF Window sash seal A-10 LX-BZA410JBEZ AD Screw A A-11 LSTP-A032JBTA AD Closure lock A-12 LSTP-A031JBTA AD Window lock A-13 UBATUA027JBE0 AE Battery B-1 LANGKA194JBTA AN Upper shutter frame B-2 LX-BZA409JBEZ AD Screw B [5] Others (Small) 41 SPAKCB855JBEZ AR Package[S60FX] 41 SPAKCB925JBEZ AR Package[R80FX] 41 SPAKCB926JBEZ AR Package[S80FX] 41 SPAKCB927JBEZ AW Package[S85FX] 44 DWAK-A923JBKA BA Front panel ass'y (include20 21 22 23 24)! 47 QACC-A306JBZZ BP Power supply cord DESCRIPTION 5

[6] Chassis Lower shutter frame (Medium) Cabinet and shutter Air flow system Electric control system Refrigerant system Front panel assy 1 2 NO. PARTS CODE PRICE NEW MARK PART [6] Chassis Lower shutter frame (Medium) 1 LCHS-A488JBTA BD Chassis[S100FX][R120FX] 1 LCHS-A492JBTA BC Chassis[R100FX] 1 LCHS-A495JBTA BC Chassis[S120FX][S125FX] 2 LANGKA200JBTA AM Lower shutter frame DESCRIPTION 6

[7] Electric control system Cabinet and shutter Front panel ass'y (Medium) Electric control system 4 6 7 8 9 10 12 3 11 24 13 14 15 16 17 Cabinet and shutter 18 16 15 14 19 23 22 21 Front panel assy 20 NO. PARTS CODE PRICE NEW MARK PART DESCRIPTION [7] Electric control system Cabinet and shutter Front panel ass'y (Medium) 3 LPLTMA215JBPZ AN Electric part box 4 RC-HZA526JBEZ BD Capacitor[S100FX][R120FX] 4 RC-HZA539JBZZ BD Capacitor[R100FX] 6 LBNDKA134JBPZ AD Capacitor clamp[s100fx][r120fx][s120fx][s125fx] 6 LBNDKA138JBPZ AD Capacitor clamp[r100fx]! 7 DPWBFA420JBKZ BM Main control board 8 LPLTMA216JBPZ BR Installation board for e-parts! 9 DPWBFA421JBKZ BA Display board 10 HPNLCA881JBFA AM Control box 10 HPNLCA880JBEA AD display panel 11 RH-HXA050JBZZ AM Evaporator temp sensor 12 RH-HXA049JBZZ AM Indoor temp sensor 16 LANGKA199JBFA AD Connection bar to cabinet 17 GCAB-A301JBTA BF Cabinet 18 LANGKA198JBTA AN Upper shutter frame 20 GWAKPA174JBFA BC Front panel (included in 47) 21 PFILMA213JBEA AG Air filter (included in 47) 22 GWAK-A325JBFA AX Panel frame (included in 47) 23 MLOV-A422JBFA AQ Horizontal louver (included in 47) 24 MLOV-A423JBFA AD Vertical louver A (included in 47) 24 MLOV-A424JBFA AD Vertical louver B (included in 47) 24 MJNTPA123JBFA AD Louver link 7

[8] Airflow system Refrigerant system (Medium) 34 42 33 32 43 31 27 28 26 29 30 39 36 37 25 35 Air flow system Refrigerant system NO. PARTS CODE PRICE NEW MARK PART [8] Airflow system Refrigerant system (Medium) 25 PKESSA101JBFZ AR Lower fan shell 26 NFANSA048JBFA AR Centrifugal fan 27 MLEVPA022JBFA AD Fresh air door 28 PKESSA102JBFZ AP Med fan shell 29 PSEL-C855JBEZ AD Water proof rubberring! 30 CMOTLB184JBEZ BW Fan motor 31 PKESPA111JBFZ AX Rear separating board 32 NFANPA126JBFA AP Propeller fan 33 PGIDMA051JBFA AF Guide for fresh air door 34 PKESSA103JBFZ AN Up fan shell 35 PEVA-A560JBEZ BS Evaporator[S100FX] 35 PEVA-A571JBEZ BS Evaporator[R100FX] 35 PEVA-A572JBEZ BV Evaporator[R120FX] 35 PEVA-A573JBEZ BU Evaporator[S120FX][S125FX] 36 PPIPCH323JB1Z AK Suction pipe[s100fx][r120fx] 36 PPIPCH397JB1Z AP Suction pipe[r100fx] 36 PPIPCH400JB1Z AQ Suction pipe[s120fx][s125fx] 37 PCON-A550JBEZ BX Condenser[S100FX] 37 PCON-A556JBEZ BU Condenser[R100FX] 37 PCON-A557JBEZ BX Condenser[R120FX] 37 PCON-A558JBEZ BX Condenser[S120FX][S125FX]! 39 PCMPRA477JBEZ CA Compressor[S100FX]! 39 PCMPRA490JBEZ CC Compressor[R100FX]! 39 PCMPRA491JBEZ CD Compressor[R120FX]! 39 PCMPRA492JBEZ CC Compressor[S120FX][S125FX] 42 PPIPCH322JB1Z AN Discharge pipe[s100fx] 42 PPIPCH396JB1Z AN Discharge pipe[r100fx] 42 PPIPCH398JB1Z AN Discharge pipe[r120fx] 42 PPIPCH399JB1Z AM Discharge pipe[s120fx][s125fx] 43 DCPY-A345JBKZ AY Capillary assembly[s100fx] 43 DCPY-A351JBKZ AX Capillary assembly[r100fx] 43 DCPY-A352JBKZ AY Capillary assembly[r120fx] 43 DCPY-A353JBKZ AY Capillary assembly[s120fx][s125fx] DESCRIPTION 8

[9] Accessories (Medium) AFS120FX A A-4 A-4 A-3 A-5 A-5 A-2 A-8 A-9 A-11 A-6 A-7 A-12 A-1 A-13 A-10 NO. PARTS CODE [9] Accessories (Medium) PRICE NEW MARK PART A CFZK-C578JBKZ BA Accessory part A-1 CRMC-A671JBEZ AU Remote controller A-2 LANGAA044JBFA AL Right shutter frame A-3 LANGAA045JBFA AL Left shutter frame A-4 LANGKA197JBFA AE Shutter locking bar A-5 PPLTPA022JBFA AQ Shutter A-6 TCAD-A659JBTZ AD Consummer card A-7 TINSEA413JBTZ AG Operation manual A-8 PSEL-C967JBEZ AG Window sash seal A-9 PSEL-C968JBEZ AG Window sash seal A-10 LSTP-A030JBTA AD Window lock A-11 LX-BZA410JBEZ AD Screw A-12 LSTP-A033JBTA AD Closure lock A-13 UBATUA027JBE0 AE Battery [10] Others (Medium) 44 SPAKCB856JBEZ AU Package[S100FX] 44 SPAKCB928JBEZ AU Package[R100FX] 44 SPAKCB929JBEZ AU Package[R120FX] 44 SPAKCB930JBEZ AU Package[S120FX] 44 SPAKCB931JBEZ AY Package[S125FX] 47 DWAK-A924JBKA BC Front panel ass'y (include20 21 22 23 24)! 50 QACC-A306JBZZ BP Power supply cord DESCRIPTION 9

INDEX PARTS CODE No. PRICE [ C ] CFZK-C576JBKZ 4-A AZ CFZK-C578JBKZ 9-A BA CMOTLB183JBEZ 3-28 BQ CMOTLB184JBEZ 8-30 BW CMOTLB197JBEZ 3-28 BR CRMC-A671JBEZ 4-A-1 AU " 9-A-1 AU [ D ] DCPY-A344JBKZ 3-40 AR DCPY-A345JBKZ 8-43 AY DCPY-A350JBKZ 3-40 AU DCPY-A351JBKZ 8-43 AX DCPY-A352JBKZ 8-43 AY DCPY-A353JBKZ 8-43 AY DPWBFA420JBKZ 2-7e BM " 7-7 BM DPWBFA421JBKZ 2-9e BA " 7-9 BA DWAK-A923JBKA 5-44 BA DWAK-A924JBKA 10-47 BC [ G ] GCAB-A300JBTA 2-17 BC GCAB-A301JBTA 7-17 BF GWAK-A320JBFA 2-22 AV GWAK-A325JBFA 7-22 AX GWAKPA171JBFA 2-20 BA GWAKPA174JBFA 7-20 BC [ H ] HPNLCA879JBFA 2-10 AM HPNLCA880JBEA 2-10 AD " 7-10 AD HPNLCA881JBFA 7-10 AM [ L ] LANGAA042JBFA 4-A-2 AK LANGAA043JBFA 4-A-3 AK LANGAA044JBFA 9-A-2 AL LANGAA045JBFA 9-A-3 AL LANGKA193JBFA 4-A-4 AF LANGKA194JBTA 4-B-1 AN LANGKA195JBFA 2-16 AD LANGKA196JBTA 1-2 AM LANGKA197JBFA 9-A-4 AE LANGKA198JBTA 7-18 AN LANGKA199JBFA 7-16 AD LANGKA200JBTA 6-2 AM LBNDKA134JBPZ 2-6 AD " 7-6 AD LBNDKA138JBPZ 7-6 AD LCHS-A487JBTA 1-1 AZ LCHS-A488JBTA 6-1 BD LCHS-A492JBTA 6-1 BC LCHS-A494JBTA 1-1 AZ LCHS-A495JBTA 6-1 BC LCHS-A496JBTA 1-1 AZ LPLTMA213JBPZ 2-3 AK LPLTMA214JBPZ 2-8 BR LPLTMA215JBPZ 7-3 AN LPLTMA216JBPZ 7-8 BR LSTP-A030JBTA 9-A-10 AD LSTP-A031JBTA 4-A-12 AD LSTP-A032JBTA 4-A-11 AD LSTP-A033JBTA 9-A-12 AD LX-BZA409JBEZ 4-B-2 AD LX-BZA410JBEZ 4-A-10 AD " 9-A-11 AD [ M ] MJNTPA121JBFA 2-24 AD MJNTPA123JBFA 7-24 AD MLEVPA022JBFA 8-27 AD MLOV-A405JBFA 2-23 AM MLOV-A406JBFA 2-24 AD MLOV-A421JBFA 2-24 AD MLOV-A422JBFA 7-23 AQ MLOV-A423JBFA 7-24 AD MLOV-A424JBFA 7-24 AD [ N ] NFANPA125JBFA 3-30 AP NFANPA126JBFA 8-32 AP NEW MARK PART PARTS CODE NFANSA047JBFA 3-26 AY NFANSA048JBFA 8-26 AR [ P ] PCMPRA476JBEZ 3-36 BZ PCMPRA477JBEZ 8-39 CA PCMPRA488JBEZ 3-36 CB PCMPRA489JBEZ 3-36 CB PCMPRA490JBEZ 8-39 CC PCMPRA491JBEZ 8-39 CD PCMPRA492JBEZ 8-39 CC PCON-A549JBEZ 3-34 BN PCON-A550JBEZ 8-37 BX PCON-A555JBEZ 3-34 BS PCON-A556JBEZ 8-37 BU PCON-A557JBEZ 8-37 BX PCON-A558JBEZ 8-37 BX PCON-A559JBEZ 3-34 BR PEVA-A559JBEZ 3-32 BM PEVA-A560JBEZ 8-35 BS PEVA-A570JBEZ 3-32 BN PEVA-A571JBEZ 8-35 BS PEVA-A572JBEZ 8-35 BV PEVA-A573JBEZ 8-35 BU PFILMA207JBEA 2-21 AG PFILMA213JBEA 7-21 AG PGIDMA051JBFA 8-33 AF PKESPA110JBFZ 3-29 AY PKESPA111JBFZ 8-31 AX PKESSA098JBFZ 3-25 AM PKESSA099JBFZ 3-27 AN PKESSA100JBFZ 3-31 AK PKESSA101JBFZ 8-25 AR PKESSA102JBFZ 8-28 AP PKESSA103JBFZ 8-34 AN PPIPCH320JB1Z 3-39 AN PPIPCH321JB1Z 3-33 AM PPIPCH322JB1Z 8-42 AN PPIPCH323JB1Z 8-36 AK PPIPCH394JB1Z 3-33 AM PPIPCH395JB1Z 3-33 AL PPIPCH396JB1Z 8-42 AN PPIPCH397JB1Z 8-36 AP PPIPCH398JB1Z 8-42 AN PPIPCH399JB1Z 8-42 AM PPIPCH400JB1Z 8-36 AQ PPIPCH401JB1Z 3-39 AP PPIPCH402JB1Z 3-39 AM PPLTPA021JBFA 4-A-5 AP PPLTPA022JBFA 9-A-5 AQ PSEL-C855JBEZ 8-29 AD PSEL-C967JBEZ 9-A-8 AG PSEL-C968JBEZ 9-A-9 AG PSEL-C969JBEZ 4-A-8 AF PSEL-C970JBEZ 4-A-9 AF [ Q ] QACC-A306JBZZ 5-47 BP " 10-50 BP [ R ] RC-HZA525JBEZ 2-4 BA RC-HZA526JBEZ 7-4 BD RC-HZA539JBZZ 7-4 BD RC-HZA540JBZZ 2-4 BB RH-HXA049JBZZ 2-12 AM " 7-12 AM RH-HXA050JBZZ 2-11 AM " 7-11 AM [ S ] SPAKCB855JBEZ 5-41 AR SPAKCB856JBEZ 10-44 AU SPAKCB925JBEZ 5-41 AR SPAKCB926JBEZ 5-41 AR SPAKCB927JBEZ 5-41 AW SPAKCB928JBEZ 10-44 AU SPAKCB929JBEZ 10-44 AU SPAKCB930JBEZ 10-44 AU SPAKCB931JBEZ 10-44 AY [ T ] TCAD-A659JBTZ 4-A-6 AD " 9-A-6 AD No. PRICE NEW MARK PART 10

PARTS CODE TINSEA412JBTZ 4-A-7 AG TINSEA413JBTZ 9-A-7 AG [ U ] UBATUA027JBE0 4-A-13 AE " 9-A-13 AE No. PRICE NEW MARK PART 11

COPYRIGHT 2005 BY SHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced, stored in retrieval systems, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher. SHARP CORPORATION Appliance Systems Group Quality Assurance Department