Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

Similar documents
High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Application Note. Authors. Abstract

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

On Line SPE LC/MS/MS Applications

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Agilent InfinityLab Online SPE Solution

Agilent 1290 Infinity II Vialsampler Data Sheet

Agilent 1290 Infinity II Online SPE Solution

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

An Introduction to Mass Spectrometry

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

CALIDUS tm the Modular micro Gas Chromatograph

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Customised HPLC Systems for Highest Performance

This document is a preview generated by EVS

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

300 series HPLC autosamplers

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

Systems. Visit us at

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A)

Spark Holland introduces

HPLC Column Ovens and Temperature Controllers

get mass. without massive work. [ 3100 MASS DETECTOR ]

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Agilent 6400 Series. Maintenance Guide. Agilent Technologies

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

detectors UltiMate 3000 Variable Wavelength Detectors

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

SCION 436-GC. Dimensions and Weights

How Important is Performance to your SPE Method Development?

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Customers should provide all necessary operating supplies upon request of the engineer.

Agilent 1290 Infinity II LC

MultiPurpose Sampler MPS robotic series

Improved HPLC Separations at Elevated Temperatures Using a New Stand-alone Preheater

Technical specifications of FT-IR Spectrometer

SEC-MALS Noise Assessment and Cleaning Guide

Agilent 1100 Series Refractive Index Detector. Reference Manual

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Apex E Quick Installation Guide

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

FIXED GAS ANALYZER (FGA)

Agilent 1200 Series Variable Wavelength Detector

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Tool-free LC connections for HPLC, UHPLC and nano LC systems

PURITY GRADES OF LAB REAGENTS

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

ice 3000 Series Atomic Absorption Spectrometers

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

CyTOF Autosampler 5 User Manual

TYPES AND APPROPRIATE INJECTORS

API LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

BenchTOF. The next generation of time-of-flight mass spectrometers for GC and GC GC

Gas Chromatography (GC-342)

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

The Complete and Easy Guide to Configuring Your Specific Thermo NanoLC for Mass Spec Analysis

GC Injectors. GC Injectors

Thermo Scientific Dionex Integrion HPIC System

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Chromatography. Research Supplies. 2014/2015 Catalog

Recent Improvements in Process GC Instrumentation

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

[ ACQUITY QDa DETECTOR ] SEPARATING BEYOND QUESTION BRINGING THE POWER OF MASS DETECTION TO YOU

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Nexera-i Specifications Prominence-i Specifications

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

GC DETECTORS Reduction Gas Detector - RGD. Overview

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

Transcription:

Comparison of Online SPE Analysis and Direct Injection of Trace Level Estrogens in Drinking Water with the Agilent 646 and Agilent 649 Triple Quadrupole s The Agilent 1 Infinity Series Online SPE Solution for the Highest Sensitivity Application Note Environmental Author Bettina Schuhn Agilent Technologies Inc., Waldbronn, Germany Abstract This Application Note demonstrates the enhanced sensitivity of the Agilent 1 Infinity Series Online SPE Solution compared to direct inject methods on a routine and a high end mass spectrometer. The sensitive analysis of estrogens in drinking water is shown with four different methods performed on an Agilent 646 Triple Quadrupole and an Agilent 649 Triple Quadrupole, both coupled to a 1 Infinity Series Online SPE Solution. The Agilent 19 Infinity Flexible Cube, which is the heart of the 1 Infinity Series Online SPE Solution, offers a highly flexible setup and supports direct injection and online SPE all in one module. With the option of a high volume injection kit (4.5 ml), it is possible to be sensitive as low as sub-1 ng/l with a routine mass spectrometer. With a high end mass spectrometer, detection limits of. ng/l were observed.

Introduction Worldwide natural and synthetic estrogens can be found in environmental water due to high pharmaceutical consumption and excretion. Estrogens, such as estrone (E1), 17-b-estradiol (E), estriol (E3) and the synthetic 17-a-ethinylestradiol (EE) are believed to play a major role in the interference with the hormonal system of exposed water organisms, such as fish. The potential consequences to humans remain still uncertain 1,. In Europe, the Water Framework Directive (WFD, /6/EC) 3 has defined a list of priority pollutants that have damaging effects on the environment. Two estrogens proposed to be included in this list of priority substances are: 17-b-estradiol and 17-a-ethinylestradiol. The proposed annual average concentrations in surface waters are.8 (E) and.7 ng/l (EE). If these estrogens are included in this list, very sensitive methods are needed for the analysis and detection of hormones, especially estrogens, in environmental water. For the sensitive analysis of estrogens in environmental matrixes, an extraction and purification step is often necessary 1. In most cases, an online solid phase extraction (SPE) method is the simplest approach to achieve this goal. The 1 Infinity Series Online SPE Solution reduces time and labor and enhances sample throughput because the whole analysis can be done with one HPLC instrument without offline sample preparation. Even with a routine mass spectrometer, high sensitivity can be achieved, as low as sub-1 ng/l, with a high volume injection (4.5 ml) coupling with different mass spectrometer. In this Application Note, estrogen related compounds (natural and synthetic) are analyzed and quantified with an online solid-phase extraction enrichment process on two different sensitive triple quadrupole mass spectrometers, a 646 and a 649 Triple Quadrupole LC/MS System. The results were compared to the direct inject methods. Experimental and Instrumentation All experiments were carried out on an Agilent 1 Infinity Online SPE Solution comprising: Agilent 16 Infinity Binary Pump G131B and LAN card G1369C Agilent 16 Infinity Standard Autosampler G139B with 9 µl head (G1313-67) and an Agilent 19 Infinity Thermostat G133B Agilent 19 Infinity Flexible Cube G47A with two -position/1 port valves Agilent 1 Infinity Online SPE starter kit: G474A (one -position/1-port valve, 6 bar) Agilent 1 Infinity Online SPE direct injection kit: G4744A (one -position/1- port valve, 6 bar) External valve drive G117A with -position/6-port valve G431A and a 5-mL loop (p/n G6-68711) Agilent 19 Infinity Thermostatted Column Compartment G1316C Agilent G646A Triple Quadrupole with Agilent Jet Stream Technology Agilent G649A Triple Quadrupole with Agilent Jet Stream Technology and ifunnel Technology Trapping columns Guard Column Hardware Kit (p/n 8999-91) (as part of G474A) Agilent ZORBAX Eclipse Plus C18, 4.6 1.5 mm, 5 µm (p/n 895 936) Software Agilent MassHunter data acquisition for triple quadruple mass spectrometer, Version 6. Agilent MassHunter Optimizer Software, Version 6. Agilent MassHunter Source and ifunnel Optimizer Software, Version 6. Agilent MassHunter Qualitative Software, Version 6. Agilent MassHunter Quantitative Software, Version 6. The LC/MS method was developed based on the Application Note 5991-473EN 6.

Table 1. HPLC Method for direct injection and online SPE. Direct inject Online SPE Injection volume 5 µl 4,5 µl Enrichment cartridges Agilent ZORBAX Eclipse Plus C18, 4.6 1.5 mm, 5 µm (p/n 895-936) 1.5 mm, 5 µm (p/n 895-936) Column temperature 3 C 3 C Column Mobile Phase Agilent Poroshell 1 Phenyl Hexyl.1 5 mm,.7 µm (p/n 699775-91) A: water + 1 mm ammonium fluoride B: methanol : acetonitrile (65:35) Gradient.5 minutes 1 % B,.5 5.5 minutes 1 1 % B, 5.5 11 minutes 1 % B Flow rate.6 ml/min.6 ml/min Agilent Poroshell 1 Phenyl Hexyl 3. 5 mm,.7 µm (p/n 699975-31) A: water + 1 mm ammonium fluoride B: methanol : acetonitrile (65:35) 1.6 minutes 1 % B, 1.6 minutes 1 1 % B, 4 minutes 1 % B System configuration and principle of operation This Application Note describes the Agilent 1 Infinity Series Online SPE Solution, which is based on the 19 Infinity Flexible Cube with an additional external valve drive next to the 19 Infinity Flexible Cube for the use of a high volume injection loop (5 ml). For more information about the plumbing and flow profile, see the Technical Overview 5991 3173EN 4. The Flexible Cube itself hosts two -position/1-port valves for the opportunity of direct injection methods and online SPE methods with alternate use of two trapping columns 5. Additionally, with the solvent selection valve in the 19 Infinity Flexible Cube, up to three solvents can be used to load and clean the SPE cartridges. For the analysis of estrogens, a RP C-18 guard column is perfectly suited as a SPE phase and is useable for a wide range of concentration, repeatability, and accuracy 1. Figure 1 presents a schematic overview of the HPLC and online SPE method. Finally, the system was coupled to an Agilent 646 and 649 Triple Quadrupole for detection and enhanced sensitivity measurements. Agilent 16 Infinity Binary Pump gradient Agilent 19 Infinity Flexible Cube and 5-mL loop 1 % B Step 1 Loading SPE 1 with 4.5 ml of sample and 15 ml of Solvent A1 The online SPE procedure consisted of three steps (Figure 1): 1. Loading and enriching the sample on the SPE cartridge (SPE 1). Elution of SPE 1 with the gradient flow 3. Rinsing and reconditioning SPE (from the previous run) Right valve switches (1.5 minutes) Step 1 % 1 % B Figure 1. Schematic of the online SPE method which includes the Agilent 19 Infinity Flexible Cube as a loading pump and an Agilent 16 Infinity Binary Pump to run the gradient and elute the analytes from the cartridges. 1.5 Step 3 SPE 1 is in front of analytical column and eluting SPE 1 while SPE is rinsed with A (8 ml) and A1 (1 ml) Time (min) 4. 3

Agilent 19 Infinity Flexible Cube Right and left valve: -position/1 port QuickChange valve head Solvent selection valve: solvent A1: water, solvent A: acetonitrile To draw 4.5 ml into the 5-mL loop, an injector program has to be defined (Table 3) 4. Samples were measured with 646 and 649 Triple Quadrupole s in negative mode. The source parameters for the Agilent Jet Stream were optimized with the Agilent MassHunter Source and ifunnel Optimizer (Table 4). The Multiple Reaction Monitoring (MRM) triple quadrupole MS method was developed with Agilent MassHunter Optimizer Software. Direct injections were used for all estrogens standards (1 ng/µl). For every compound, two MRM transitions were optimized regarding fragmentor voltage, cell accelerator voltage, and collision energy. Table 5 shows the suite of five estrogens. Table. Piston pump timetable in the Agilent 19 Infinity Flexible Cube for the online SPE method. Time Function Parameter Pump for volume Pump 15 ml, flow: 1.5 ml/min Channel A1 (water) 1.5 Right valve change position Increase valve position (switch valve) 1.6 Pump for time Pump 8 ml, flow: 1.5 ml/min Channel A (ACN) 16 Pump for time Pump 1 ml, flow: 1.5 ml/min Channel A1 (water) Table 3. Injector program. Injector program to load 4.5 ml Repeat four times: 1. Draw 9 µl (draw speed 9 µl/min, eject speed 9 µl/min). Needlewash 3. Eject to seat 4. End repeat 5. Draw 9 µl 6. Inject Table 4. Ion source parameters for Agilent Jet Stream negative ionization for the Agilent 646 Triple Quadrupole and Agilent 649 Triple Quadrupole. Parameters Agilent 646 Triple Quadrupole Nozzle 5 V V Capillary 3, V 3,5 V Sheath gas temperature 4 C 375 C Sheath gas flow 1 L/min 1 L/min Drying gas temperature 35 C 15 C Drying gas flow 1 L/min 16 L/min Nebulizer 45 psi 4 psi D EMV 6 V 3 V Agilent 649 Triple Quadrupole Table 5. Five estrogens are listed with their mass, formula, precursors and adducts, product ions, and polarity. Steroid Mass (g/mol) Formula Precursor ion ( m/z) Product ion 1 and (m/z) Polarity Estrone (natural estrogen) 7.3 C 18 H O 69.1 145./14.9 negative 17-b-Estradiol (natural estrogen) 73.3 C 18 H 4 O 71. 183./145.1 negative 17-a-Ethinylestradiol (synthetic estrogen) 96.4 C H 4 O 95.4 145/143 negative Estriol (natural estrogen) 88.3 C 18 H 4 O 3 87.3 143/171. negative Hexoestrol (synthetic estrogen) 7 C 18 H O 69.15 134/119. negative 4

Samples Tap water was spiked in different calibration levels with estrogens. Seven calibration standards of estrogens for the direct injection on the 646 Triple Quadrupole, ranging from.5 to ng/l (.5, 5, 1, 5, 5, 1, and ng/l) each, were prepared by appropriate dilution of the stock solution ( ng/l). A seven level calibration curve for the online SPE method on the 646 Triple Quadrupole was prepared in the range of.1 5 ng/l (.1,.5, 1,, 5, 1, 5, and 5 ng/l). Results and Discussion Linearity, limit of detection (LOD), and limit of quantification (LOQ) The online SPE as well as the direct inject methods show excellent linearity for all estrogens in different concentration ranges with the 646 and 649 Triple Quadrupole. For the 646 Triple Quadrupole LC/MS System, the linearity was measured in spiked drinking water for the direct inject method in the range of.5 to ng/l and for the online SPE method in the range of.1 to 5 ng/l. In Figure, the calibration curves of 17-b-estradiol and 17-a-ethinylestradiol are shown for the online SPE method. The direct inject and online SPE methods were transferred from a 646 Triple Quadrupole to a higher sensitive triple quadrupole. The 649 Triple Quadrupole LC/MS System includes ifunnel technology for ultra trace analysis and highest sensitivity. A seven-level calibration curve was done for the high sensitivity 649 Triple Quadrupole and direct injection, which was in the range from.5 5 ng/l (.5, 1,.5, 5, 1, 5, and 5 ng/l). For the online SPE method, the calibration curve was in the range of.5 5 ng/l (.5,.1,.5, 1,.5, 5, 1, and 5 ng/l). Chemicals All solvents used were LC/MS grade. Acetonitrile and methanol were purchased from Merck, Germany. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with LC-Pak Polisher and a.-μm membrane point-of-use cartridge (Millipak). Ammonium fluoride was purchased from Sigma Aldrich, St. Louis, USA. All estrogen standards were purchased from Dr. Ehrenstorfer GmbH, Germany at a concentration of 1 ng/µl in acetonitrile. 1 4 A 3.6 17-b-Estradiol 3. y =.347*x + 714.983389*x + 8.533453.8 R =.9997787.4 1.6 1..8.4 Responses Responses 4 8 1 16 4 8 3 36 4 44 48 5 Concentration (pg/ml) 1 4 B 17-a-Ethinylestradiol 1.8 y =.51857*x + 369.761439*x + 1539.19741 1.6 R =.99897365 1.4 1. 1.8.6.4. 4 8 1 16 4 8 3 36 4 44 48 5 Concentration (pg/ml) Figure. Calibration curve (1 5 ng/l) for 17-b-estradiol (A) and 17-a-ethinylestradiol (.1 5 ng/l) (B) with R.999, measured with an Agilent 646 Triple Quadrupole and online SPE. 5

Calibration curves were prepared in drinking water in the range of.5 5 ng/l (8 level) for all estrogens. Figure 3 shows the calibration curves of estrone, hexoestrol, and estriol with a good linearity over a wide range of calibration. Table 6 summarizes R for both direct inject and online SPE methods performed on the 646 and 649 Triple Quadrupole in different concentration ranges. Responses Responses Responses 1 5 5 4.5 4 3.5 3.5 1.5 1.5 1 5 5 4.5 4 3.5 3.5 1.5 1.5 1 4 4.4 4 3.6 3..8.4 1.6 1..8.4 A Estrone y = 8.478176*x + 17658.34888*x 655.65785 R =.9997738 - -1 1 3 4 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 134567 Concentration (ng/l) B Hexoestrol y = 16.8819*x + 1535.9796*x + 114.518453 R =.998569 - -1 1 3 4 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 134567 Concentration (ng/l) C Estriol y = -.618848*x + 1684.61761*x + 1841.79945 R =.99714166 - -1 1 3 4 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 134567 Concentration (ng/l) Figure 3. Calibration curve (.5 5 ng/l) for estrone (A), hexoestrol (B), and estriol (C) (1 5 ng/l) with R <.997, measured with a Agilent 649 Triple Quadrupole and an Agilent 1 Infinity Online SPE. Table 6. R for direct inject and online SPE methods on two different triple quadrupoles. Agilent 646 Triple Quadrupole Agilent 649 Triple Quadrupole Direct inject Online SPE Direct inject Online SPE R (.5 ng/l) R (.1 5 ng/l) R (.5 5 ng/l) R (.5 5 ng/l) Estriol.999.999.998.996 17-a-Ethinylestradiol.999.998.997.998 17-b-Estradiol.999.999.998.999 Estrone.999.999.999.999 Hexoestrol.997.999.999.998 6

Table 7 shows a comparison and summary of direct injections and online SPE methods on two triple quadrupoles. For all methods, the LOD, signal-to-noise ratio (S/N) > 3 and LOQ, S/N > 1 were determined. Table 7 demonstrates a significant increase in sensitivity between direct inject methods and online SPE methods on both detectors. A further increase in sensitivity also could be observed between 646 and 649 Triple Quadrupole s. In general, a gain of sensitivity was determined with a factor of to 1 between the direct inject method compared to the online SPE method. The 17-a-ethinylestradiol particularly increased with the online SPE enrichment process. A factor of 5 for the LOD was determined with the 646 Triple Quadrupole, from 5 ng/l direct inject to.1 ng/l online SPE (Figure 4). The lowest detection limits were observed with the 649 Triple Quadrupole and online SPE enrichment. Up to. ng/l can be measured for estrone and hexoestrol in spiked drinking water. Figure 5 shows the LOQ for estrone. Generally, the difference in sensitivity between the 646 and 649 Triple Quadrupole s is approximately a factor of to 1. Table 7. LOD and LOQ for direct inject and online SPE methods on an Agilent 646 Triple Quadrupole and an Agilent 649 Triple Quadrupole. 646 Triple Quadrupole 649 Triple Quadrupole Direct inject Online SPE Direct inject Online SPE LOD (ng/l) LOQ (ng/l) LOD (ng/l) LOQ (ng/l) LOD (ng/l) LOQ (ng/l) LOD (ng/l) LOQ (ng/l) estriol 1 5 5 1 5 1 1.5 17-a-ethinylestradiol 5 1.1 1.5.1.5 17-b-estradiol 5 1.5 1.5..5 estrone 1.5. 1.1.5..5 hexoestrol 1.5..5.1.5..5 Counts 1 3. Noise (Peak-to-peak) =.5; SNR (16.37 minutes) = 11.6 1,61 3.8.6.4. 1.8 1.6 1.4 1. 1.8.6.4. 17 133 16 1 14 14.5 15 15.5 16 16.5 17 17.5 18 18.5 19 Acquisition time (min) Figure 4. 17-a-ethinylestradiol at a concentration of.1 ng/l with online SPE injection measured with an Agilent 646 Triple Quadrupole. 1.5.4.3..1 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1. 1.1 1.9.8.7.6.5.4.3 Counts Noise (Peak-to-peak) = 6.64; SNR (19.8 minutes) = 8.1 3,514 968 15 16 17 18 19 1 3 4 Acquisition time (min) Figure 5. Estrone at a concentration of.5 ng/l in drinking water with online SPE injection measured with an Agilent 649 Triple Quadrupole. 7

Area precision data of LOD, LOQ, and RT For the online SPE method, replicative measurements were performed (n = 6) for the determination of LOD, S/N > 3 and LOQ, S/N > 1 regarding the area precision data on the 646 as well as the 649 Triple Quadrupole. Table 8 shows that the area RSD for all compounds and each Triple Quadrupole was usually < 15 % and the average area RSD was approximately 1 %. Table 8. Area precision data for LOD and LOQ for all compounds and online SPE methods on the Agilent 646 and Agilent 649 Triple Quadrupole s. Agilent 646 Triple Quadrupole Agilent 649 Triple Quadrupole % RSD LOD % RSD LOQ % RSD LOD % RSD LOQ Estriol 8.31 8.35 13.7 1.9 17-a-Ethinylestradiol.31 11.7 19.3 18.7 17-b-Estradiol 5.11 7.91 11.51 11.68 Estrone 1.1 6.4 9.7 9.91 Hexoestrol 14.86 11.61 1.36 11.1 The RSD for retention time (RT) precision for all online SPE runs and two alternatively used cartridges (n = 336) was.1 %. Carryover for online SPE For the 1 Infinity Series Online SPE coupled to the 646 Triple Quadrupole, carryover was observed only for 17-a-ethinylestradiol in the blank injection after the highest standard of 5 ng/l estrogens. The blank injection was determined to be 1 % with a S/N ratio of 1.6. For the 649 Triple Quadrupole LC/MS System, no carry over was determined for any compound. 8

Conclusion For the sensitive analysis of estrogens in water, the Agilent 1 Infinity Series Online SPE Solution offers a flexible and cost-effective solution. Direct injections, online SPE, and high volume injections (up to 5 ml) with the online SPE can be done with one instrument. Coupled to different detectors, such as an Agilent 646 Triple Quadrupole or an Agilent 649 Triple Quadrupole, improved sensitivity can be achieved. For the analysis of estrogens in drinking water, LOD down to. ng/l was determined. Excellent linearity was observed for all compounds for a wide range of concentrations on both MS detectors. It was observed that the 649 Triple Quadrupole compared to the 646 Triple Quadrupole was up to 1 times more sensitive. Carryover was determined only for 17-a-ethinylestradiol on the 646 Triple Quadrupole. The blank injection was determined to be 1 % with a S/N ratio of 1.6. The results of this work shows that the 1 Infinity Series Online SPE Solution is perfectly suited for the analysis of estrogens in water. Because of the high flexibility of the system, it is a good option for medium throughput laboratories that want more sensitive results for their water analysis and need a flexible solution for different applications. 9

References 1. M.J. López de Alda and D. Barceló Use of solid-phase extraction in various of its modalities for sample preparation in the determination of estrogenes and progesterones in sediment and water Journal of Chromatography A, 938 145 153 (1).. J.M. Ronan and B. McHugh A sensitive liquid chromatography/ tandem mass spectrometry method for the determination of natural and synthetic steroid estrogens in seawater and marine biota, with a focus on proposed Water Framework Directive Environmental Quality Standards Rapid Commun. Mass Spectrom 7, 738-746 (13). 3. Directive No. /6/EC of the European Parliament and of the Council of 3 October establishing a framework for Community action in the field of water policy, Official Journal of the European Communities (). 4. B. Schuhn High volume injection up to 5 ml with the Agilent 1 Infinity Series Online SPE Solution for highest sensitivity Technical Overview, Publication Number 5991-3173EN (13). 5. Edgar Naegele Comparison of Direct Injection and Online SPE for Quantifi cation by LC/MS of Trace Level Herbicides in Water Agilent Technologies Application Note, Publication Number 5991-14EN (13). 6. R. Hindle Improved Analysis of Trace Hormones in Drinking Water by LC/MS/MS (EPA 539) using the Agilent 646 Triple Quadrupole LC/MS Agilent Technologies Application Note, Publication Number 5991-473EN (13). www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 13 Published in the USA, December 1, 13 5991-344EN