Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Similar documents
Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

CONDENSERS AND CONDENSING UNITS

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

ALL PRODUCTS BROCHURE

Innovative Design, Performance, & Serviceability

Water-Source Heat Pumps

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

THE ULTIMATE ROOFTOP SOLUTION

RoofPak Applied Rooftop Systems

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Commercial Packaged Rooftop Systems

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Trailblazer air cooled scroll chillers

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

Water-cooled chillers with High Speed Centrifugal Compressors

The ultimate fresh air solution.

48TM GAS HEATING/ELECTRIC COOLING UNITS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

OACS Outdoor Air-Cooled Central Chillers

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Direct Fired Heater Model AD Specification

GP SERIES Packaged Chillers

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

Flexible & Innovative. Cooling Solutions

Tulsa, OK Longview, TX

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

RT-OA TM Rooftop Outdoor-Air (DOAS)

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Reinventing Energy Efficiency

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Maverick II Commercial Rooftop Systems 15 to 75 tons

Engineered for flexibility and performance

Direct Gas-Fired Make-Up Air Models DG and DGX

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

GARCIA GALUSKA DESOUSA Consulting Engineers

Cultivator & Hybrid Cultivator

50 Series AQUAZONE Water Source Heat Pumps

MAC N-407 Air-Cooled Chiller

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

VariCool VAV Engineering Guide

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

30GN FLOTRONIC II AIR-COOLED CHILLERS

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

RGE 13 A T - 1 A

HVAC Water chiller selection and optimisation of operation

MAC-120HE-03 Air-Cooled Chiller

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Manufacturer Update 2014 IGSHPA

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

LZ Series. Installation, Operation, & Maintenance. Chillers and Outdoor Mechanical Rooms

MEDICAL CHILLER SYSTEMS

30GT FLOTRONIC AIR-COOLED CHILLERS

LL Series. Installation, Operation & Maintenance. Chillers and Outdoor Mechanical Rooms

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Method to test HVAC equipment at part load conditions

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

LF Series. Installation, Operation, & Maintenance. Air-Cooled Chillers WARNING WARNING WARNING

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

sm All Product Catalog

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Trailblazer Air-Cooled Scroll Compressor Chillers. Model AGZ, E Vintage 030 to 180 Tons (100 to 630 kw) HFC-410A Refrigerant 60/50 Hz.

NQ Series Portable Chillers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

MODELS LIST. Nominal Capacity RT

LF Series. Installation, Operation, & Maintenance. Air-Cooled Condenser Chillers WARNING WARNING WARNING

Modular Air-cooled Chillers

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Transcription:

LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable capacity R-410A scroll compressors Variable capacity magnetic bearing R-134a centrifugal compressors High efficiency shell and tube evaporators Factory installed standard efficiency (88 % ) and high efficiency (98 % ) boilers with input capacities from MBtu/h Factory engineered and installed pumping packages Double wall rigid polyurethane foam panel construction Service access doors with full length stainless steel piano hinges and zinc cast lockable handles Factory installed DDC controller compatible with BACnet, Modbus, Johnson N2 and LonTalk protocols Evaporative-Cooled Application Flexibility Minimizes Installation Time and Reduces Cost Factory Installed Pumping Packages Variable Capacity Compressors Easy to Install and Service Factory Installed Boilers

H LL Chillers AAON LL chillers and outdoor mechanical rooms are engineered for performance and serviceability. Variable capacity compressors and high efficiency air-cooled and evaporative-cooled condensing are available to maximize performance. All models feature double wall rigid polyurethane foam panel construction with walk-in service compartments which allow maximum accessibility while installing and maintaining the equipment. The chiller can also be provided with factory engineered and installed pumping packages and factory installed boilers, eliminating the need for an indoor mechanical room. Superior Features Variable capacity R-410A scroll compressors and variable capacity R-134a centrifugal compressors are available for load matching cooling capabilities and increased part load efficiency. Compressors are installed on structural decks and rubber isolation mounted for quiet and efficient operation. Factory installed and insulated shell and tube evaporators are reliable and energy efficient. High efficiency air-cooled condenser or evaporative-cooled condenser are designed to maximize the performance of the chiller. Factory installed, microprocessor controlled, three chemical, water treatment system is standard with an evaporative-cooled condenser saving installation and maintenance time and money. Two-inch double wall polyurethane foam panel construction provides R-13 thermal resistance, makes the cabinet more rigid and resistant to damage, and attenuates radiated compressor and pump noise. Controls, compressors, chiller and water system are accessed through a lighted walk-in cabinet which shields components and service personnel from weather and the outdoor elements year round. Service vestibule can be independently heated and/or cooled for comfort while maintenance is performed on the unit. Aluminum tread plate flooring is included in equipment access areas for improved durability and safety. Access doors with full length stainless steel hinges and zinc cast, lockable handles make the unit easily serviceable. Designed for outdoor operation, the LL includes corrosion resistant exterior paint which exceeds a 2,500 hour salt-spray test. Where possible, units are wired with a single point electrical connection to save installation costs. Factory provided and installed DDC controller is compatible with BACnet, Modbus, Johnson N2 and LonTalk protocols. Run test report, color-coded wiring diagram and Installation, Operation and Maintenance manual with startup form are included in the control compartment. W L L W H Premier Options Factory installed primary or primary/secondary pumping systems in either constant or variable flow configurations. VFD controlled pumps for precise control and reduced power consumption. Factory installed conventional and condensing boilers provide energy efficient heat and save valuable interior building space. Factory installed compressor isolation valves and water system thermometers and pressure gauges save installation time at the job site. Diaphragm expansion/compression tanks can be pre-engineered and factory installed in the water system of the LL mechanical room. Glycol chillers for refrigeration applications. Factory installed option boxes add space for field installed components or service access. Heat pump and waterside economizer configurations can meet difficult design applications while maintaining high unit efficiencies. 5 year non-prorated compressor warranty.

Comfort or Process Cooling LL Model Chiller Capacity (tons) 035 Condenser Type Compressor Type Boiler Input Capacity (MBtu/h) 050 055 060 067 NA** 075 085 090 092 NA** 104 105 115 Air-Cooled or R-410A 118 NA** Evaporative-Cooled Scroll 125 140 150 170 185 210 230 245 275 NA** 300 335 365 Width Height Length 100 142 102 *Length varies depending on options selected. 90 120 150 180 181 240 300 360 450 540 Evaporative-Cooled R-134a Centrifugal 100 142 All dimensions are in inches. ** Dual ended units are not available with boilers. LL 102 *Length varies depending on options selected. Chillers See AAON selection software for detailed, application specific, unit efficiencies.

Chiller + Boiler + Pumps = Variable Speed Direct Drive Condenser Fans Evaporative-Cooled Condenser Factory installed evaporative-cooled condenser is available for ambient wet bulb condensing. AAON engineered evaporative-cooled condenser, with air-cooled de-superheater and VFD controlled variable speed condenser fans, uses 22-100 % less water than a conventional evaporative-cooled condenser, and require 22-100 % less chemical usage than a conventional evaporative-cooled condenser. Interior of evaporative-cooled condenser is constructed of 304 stainless steel and other non-corrosive materials. De-superheater coils include polymer e-coating for corrosion protection. AAON evaporative-cooled condensing saves costs when compared with a water-cooled chiller system because the water treatment system is factory installed and evaporative-cooled condensing does not require field installation of a cooling tower or condenser water pumping. R-410A Scroll Compressors DualArm Primary Pumping Factory Installed Expansion/Compression Tank Stainless Steel Wetted Surfaces Three Chemical Water Treatment System Redundant Secondary Pumping Double Wall Rigid Polyurethane Foam Insulated Wall, Door, Roof and Floor Construction 335 ton Dual Ended Outdoor Mechanical Room Evaporative-Cooled Condenser with Air-Cooled De-Superheater Coil System

Variable Speed Direct Drive Condenser Fans 540 ton Outdoor Mechanical Room Control Compartment Chillers Variable Capacity R-134a Centrifugal Compressors Stainless Steel Wetted Surfaces Evaporative-Cooled Condenser with Air-Cooled De-Superheater Coil System Sloped Condenser Coils with Exterior Perforated Metal Screen Protection Factory Installed Shell and Tube Evaporator Direct Drive Condenser Fans Factory Installed Boiler Three Chemical Water Treatment System R-410A Scroll Compressors Factory Installed Expansion/Compression Tank 35 ton Single Ended Outdoor Mechanical Room Double Wall Rigid Polyurethane Foam Insulated Wall, Door, Roof and Floor Construction Replaceable Core Filter Driers with Isolation Valves Double Wall Rigid Polyurethane Foam Insulated Wall, Door, Roof and Floor Construction Grooved End Piping and Fittings Factory Installed Boiler Pumping Air-Cooled Condenser Air-cooled condenser is designed for quiet, energy efficient operation. Coils are sloped to prevent fin damage and coils facing outwards are protected by perforated metal screens. VFD controlled variable speed condenser fans are available for head pressure control at off-design ambient conditions. Flooded condenser low ambient option allows cooling operation at 0 F. Polymer e-coated air-cooled condenser coils are available to extend the life of the coils and protect them in corrosive environments.

Easy to Install, Service and Maintain Outdoor Mechanical Room LL packaged outdoor mechanical rooms are ideal for new construction, building retrofits, equipment expansion, system redundancy or temporary chilled water applications. Factory Installed Chiller and Pumping Package Factory Installed Conventional Boiler and Pumping Package Factory Installed Pumping Packages Factory engineered, installed and tested primary or primary/secondary pumping systems, in either constant or variable flow configurations, save field installation costs and valuable interior mechanical room building space. VFD controlled pumps provide precise control and reduced power consumption at part load. All pump packages include a factory installed in-line air separator, strainer, pump and combination valve (isolation, check and flow balancing) in the water system. Redundant and dualarm pumps are available for system for standby or parallel pump systems. Grooved end piping and fittings are standard with LL chillers. AAONEcat32 selection software allows quick and easy selection of proper pumping package components and includes pump performance curves and water piping diagram. Factory Installed Conventional Boilers Factory installed natural gas and propane boilers, with input capacities from MBtu/h, save interior mechanical room space and provide energy efficient heat. One to four boilers, in 500, 750, 1,000 and 1,500 MBtu/h input capacities, are available within a single LL outdoor mechanical room for extra capacity or redundancy. Both 20 F ΔT and 40 F ΔT boilers are available for application flexibility. Boiler heating modulation, from 10 to 100%, is achieved using a VFD to control combustion air and an air-fuel ratio modulating gas valve. Standard efficiency boilers are designed to operate at 88% thermal efficiency with NOx ratings less than 9.9 ppm. The boiler s design includes the very best of existing copper tube and copper-finned boiler technology. The combustion chamber is completely enclosed in a stainless steel compartment. For additional reliability, the boiler s electrical spark-to-pilot ignition utilizes a UV scanner to prove pilot before main gas valves open. Factory Installed Condensing Boilers Factory installed natural gas condensing boilers, with input capacities from MBtu/h, save interior mechanical room space and provide energy efficient heat. One to four boilers, in 500, 750, 1,000 and 1,500 MBtu/h input capacities, are available within a single LL outdoor mechanical room for extra capacity or redundancy. Both 20 F ΔT and 40 F ΔT boilers are available for application flexibility. The condensing boilers operate with up to a 98% thermal efficiency, a fully modulating burner and a low NOx rating. The boiler heat exchanger is constructed of stainless steel and the burner includes direct-spark ignition. These boilers also include factory provided controls with a built-in cascading sequencer to optimizer operation. Condensing Boiler

Variable Capacity Compressors LL chillers are available with variable capacity compressors which allow the chiller to be able to provide a consistent leaving water temperature at all operating conditions. Variable capacity R-410A scroll compressors are available for load matching cooling capabilities and increased part load efficiency. Variable capacity R-134a centrifugal compressors provide load matching cooling capabilities, with quiet energy efficient operation. During part load operation, reducing compressor capacity saves system operating costs. Low turndown capabilities minimize the water loop volume required to maintain a stable setpoint temperature. LL Chillers 10-100 % Variable Capacity Scroll Compressor Oil-Free Magnetic Bearing Variable Capacity Centrifugal Compressor AAON Chillers AAON LL chillers are available from 35-540 tons. AAON LC chillers are available from 5-54 tons. Both are available with variable capacity compressors and factory installed pumping packages.

AAON Environmentally Friendly HVAC Product Family Custom & Cataloged Air Handling Units (800-200,000+ cfm) Condensers & Condensing Units (2-230 tons) Chillers (Air-Cooled, Evaporative- Cooled, Heat Pump) (5-540 tons) Rooftop Units (2-230 tons) Outdoor Mechanical Rooms (Chillers, Boilers & Pumps) Self-Contained Units (2-70 tons) Heating and Cooling for... Auditoriums Convenience Stores Health Clubs Healthcare Facilities Homes Lodgings Manufacturing Museums & Libraries Natatoriums Office Buildings Restaurants Retail Stores Schools Supermarkets Residential Systems (2-5 tons) Geothermal & WSHP Units (2-230 tons) Air-Source Heat Pumps (2-230 tons) Defining Quality. Building Comfort. 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. LL R42980 110112