Beam Detectors. The 6500 Series

Similar documents
Analogue Detectors. Series 200 plus

Conventional Detectors

FAAST. Fire Alarm Aspiration Sensing Technology

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Reflective Optical Beam Smoke Detector User Guide

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Corporate Expertise. From the global experts in quality, technology and total cost of ownership of fire detectors.

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Aspirating Systems. Ducts. System Sensor Design Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Optical Beam Smoke Detector RK90R - RK90RS

Motorised Infrared Optical Beam Smoke Detector. User Guide

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Range brochure. Beam detection. others look up to.

FIRERAY 5000 range USER GUIDE

BEAM355A, BEAM355SA Single-ended Reflected Type Projected Beam Smoke Detector

BEAM355, BEAM355S Single-ended Reflected Type Projected Beam Smoke Detector

Open-area Smoke Imaging Detector. Engineering Specification

BEAM200, BEAM200S Single-ended Reflected Type Projected Beam Smoke Detector

SK-Beam, SK-Beam-T Single-ended Reflected Type Projected Beam Smoke Detector

BEAM200, BEAM200S Single-ended Reflected Type Projected Beam Smoke Detector

TECHNICAL SPECIFICATIONS BUTTONS

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

BEAM200A, BEAM200SA Single-ended Reflected Type Projected Beam Smoke Detector

BEAM200, BEAM200S Single-ended Reflected Type Projected Beam Smoke Detector

Touchpoint Pro Flexible Gas Control System

intelligent fire alarm ID60series panels

Open-area Smoke Imaging Detection (OSID)

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

HART XL High Sensitivity Smoke Detection

CO2 Carbon Dioxide Sensor

Fact File 66. Guide to Beam Smoke Detectors

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

BEAM1224A, BEAM1224SA Single-ended Reflected Type Projected Beam Smoke Detector

Touch Screen 1 loop Addressable Fire Alarm Panel

D296/D297. Application Guide. Projected Beam Smoke Detectors

ID50series. intelligent fire alarm panels

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

FireClass. Introducing a new class of fire detection

End To End Optical Beam Smoke Detector. Additional Information

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

ALK-V PHOTOELECTRIC SMOKE SENSOR

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Cerberus FIT conventional system

Dräger REGARD 3900 Series Control System

INTREPID Perimeter Intrusion Detection System

Intelligent addressable fire alarm control panel

Installation and Operation Manual

Controllers, Indicators & Set Point Programmers

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

HART XL High Sensitivity Smoke Detection

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Reflective Beam Smoke Detector

Pedestrian Swing and sliding doors. Accessories

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Sieger fixed gas detection. Fixed protection from hazardous gas

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

this is by far the best beam money can buy

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

Line Smoke Detector LRMX

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

ADPRO PRO Series by Xtralis

Laser Technology Smoke Detector

Open-area Smoke Imaging Detection (OSID)

Evolution Analogue Addressable Fire System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Photoelectric laser sensors E3C-LDA SERIES. l o n g - d i s t a n c e, a d j u s t a b l e l a s e r b e a m. Advanced Industrial Automation

designed for rail 5000 Series

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

SecuriBeam Optical Beam Fire Detectors

Dräger REGARD -1 Control System

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

Intelligent Signature Series Analog Detection

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Laptop / PC Programming Manual

Key Features. General Description

Flexible Air-sampling Smoke Detection

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Dräger REGARD -1 Control System

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

FL2011EI-HS FL2012EI-HS FL2022EI-HS

Intrusion Outdoor Protection Perimeter

Dräger REGARD -1 Control System

Return loss measurement of fiber optic components

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Open-area Smoke Imaging Detection (OSID)

Transcription:

Beam Detectors The 6500 Series

The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m 2 state-ofthe-art facility in Trieste, Italy. Quite simply, it s the best of its kind. Advanced technology and manufacturing processes coupled with dedicated staff ensure precision manufacturing and incomparable quality control. And 100% testing ensures that nothing leaves our doors unless it s in perfect working order and capable of providing years of trouble-free protection. We complement this unique offering with a global network of fire systems integration and distribution partners who serve end-users, consulting engineers and specifiers in more than forty countries. All share in our business expertise and, of course, our passion for perfection.

Conventional & Analogue Beam Detectors The 6500 Series consists of a transmitter and a receiver contained in a single enclosure. The emitted infrared beam is returned to the detector from a reflector panel located between 5 and 100 metres away. Special setup mode makes alignment and setup a simple operation for one man; alignment of the detector is simplified with the aid of the detector s gun sight targeting device. Alignment of the detector with the reflector can be fine tuned with the aid of a numerical signal strength indicator. The unit can be adjusted by ±10 degrees in both the horizontal and vertical planes; where greater angular adjustment is required, the multimount accessory enables the detector to move through 180 degrees horizontally. Automatic drift compensation prevents the long-term build up of dust or dirt on the optical surfaces from making the detector more sensitive; the design of the enclosure also ensures that settling dust attenuates the optical path as little as possible. The sensitivity of the detector can be set to one of four levels between 25% and 50% obscuration, providing application flexibility to suit the environment in which the detector will be installed. Asuretest 6500 Series has a unique patented remote test capability that fully tests both the optics and the electronics of the device without having to physically access the unit. A servo operated filter is introduced into the optical path, attenuating the beam and causing the unit to go into alarm. Unlike other test methods, this test process provides a complete check of every component in the alarm path without the need for access at high level. In the conventional version, the filter is activated from ground level by a hard-wired connection; in the analogue addressable model it is initiated by a command from the fire control panel. Given that the majority of beam detectors are likely to be installed at a considerable height, the time saved during routine maintenance will be significant.

ANALOGUE 6500 AND 6500S CONVENTIONAL 6500 AND 6500S REMOTE TEST SWITCH RTS151KEY OPTIONS The analogue 6500 series beam detector is loop powered with operation from any control panel running the System Sensor Series 200 Advanced Protocol. The 6500S has traditional loop communications, but as it includes the Asuretest remote test option requires an external 15VDC power supply. The conventional 6500 series beam detectors are both externally powered. The 6500R can be operated from a 12VDC or 24VDC supply enabling its use in either a security or fire system. The Asuretest remote test option requires 15VDC power supply and can only operate in a 24VDC Fire System In the conventional version of the beam detector, an optical filter is activated from ground level by a hard-wired connection from the test switch. This test process provides a complete check of every component in the alarm path without the need for access at high level. A number of mounting options and range extensions are available to allow installation in any environment.

The unique auto-adjusting sensitivity algorithm automatically adjusts the alarm threshold to compensate for short-term changes in the environment which could otherwise result in unwanted alarms. Two alternative auto-adjusting sensitivity settings are available. These adjustments do not compromise the detector s ability to respond quickly to a fire incident. Asuretest is available on both addressable and conventional models so there s no need to hire a platform to give high level access to the device in testing Two automatically variable sensitivity modes compensate for short term environmental changes Automatic drift compensation compensates for long term sensitivity changes caused by environmental factors Four fixed sensitivity levels 5 100m operating range, designed for the protection of buildings such as shopping centres, heritage buildings, warehouses and other structures with large open spaces Easy set-up and calibration with visual aids for both coarse and fine adjustment Loop-powered addressable or externally powered conventional versions The 6500R operates from both 12 and 24VDC, enabling it to be used as part of either a fire or a security system Series 200 Advanced Protocol in the addressable models supporting up to 159 detectors and modules on the control panel loops Fully integrated and controllable isolation for system mapping in the addressable models Total electrical backwards compatibility with existing protocols Key Features & Benefits

European Head Office System Sensor Europe Javastrasse 2 8604 Hegnau Switzerland European Manufacturing Centre System Sensor Via Caboto 19/3 34147 Trieste Italy Tel: +39 040 949 0111 Fax: +39 040 382 137 Email: sse.sales@systemsensor.com www.systemsensoreurope.com Copyright 2012 System Sensor. All rights reserved. All technical data is correct at time of publication and is subject to change without notice. All trademarks acknowledged. Installation information: in order to ensure full functionality, refer to the installation instructions as supplied.