WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

Similar documents
COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Environmental Health & Safety

MONTECITO FIRE PROTECTION DISTRICT

Gas Station & C Store SECTION CWM Job No

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE SUPPRESSION SPRINKLER SYSTEM

FIRE SPRINKLER SYSTEMS POLICY

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

New Construction Fire Inspection Process

SECTION WET-PIPE SPRINKLER SYSTEMS

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

DIVISION 21 - FIRE SUPPRESSION

FIRE SPRINKLER SYSTEMS POLICY

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

SECTION SPRINKLER SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

2. Welding Materials and Procedures shall conform to the ASME Code.

Port of St Helens SIA Aircraft Hanger Scappoose, OR

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

CITY OF PASADENA FIRE DEPARTMENT

NFPA Edition Update

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

B. Section Identification for Fire Suppression Piping and Equipment.

DIVISION 21 - FIRE SUPPRESSION

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION WET-PIPE SPRINKLER SYSTEMS

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

McMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION

Design & Construction Standards, Revised January

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

SPRINKLERS TABLE OF CONTENTS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

DESIGN & CONSTRUCTION GUIDELINES

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

SECTION WET-PIPE SPRINKLER SYSTEMS

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

SECTION WET FIRE SPRINKLER SYSTEMS

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

Sprinkler Permit Applications

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

standard/quick response extended coverage light and ordinary hazard elo sprinklers

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

PLAN REVIEW CHECKLIST

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

A. This section includes design and performance information for fire protection and suppression systems.

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

SECTION FIRE-SUPPRESSION STANDPIPES

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

B. Related Sections: The following Sections contain requirements that relate to this Section.

State Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors. Residential Fire Sprinkler Inspections

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

SECTION FIRE SUPPRESSION SYSTEMS

DIVISION 21: FIRE SUPPRESSION WATER BASED FIRE SUPRESSION SYSTEMS

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

standard response dry horizontal sidewall sprinklers

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

AUTOMATIC FIRE SPRINKLER SYSTEMS

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

WET AUTOMATIC FIRE SPRINKLER SYSTEMS

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

Transcription:

SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: WALL ESCUTCHEON PACK ANNULAR SPACE WITH MINERAL WOOL GENERAL NOTES. THIS PROJECT INCLUDES THE DESIGN AND PROVISION OF A NEW WET SPRINKLER SYSTEM THROUGHOUT THE UNSPRINKLERED PORTIONS OF THE BUILDING INDICATED ON THE FOLLOWING DRAWINGS.. THE ARCHITECTURAL BACKGROUND PROVIDED ON THESE SHEETS IS FOR GENERAL REFERENCE ONLY. CONTRACTOR SHALL VERIFY ALL BACKGROUNDS WITH ARCHITECTURAL SHEETS AND SITE VISIT.. SYSTEM DESIGN TO BE PER NFPA, 00 EDITION AND THESE DRAWINGS AND SPECIFICATIONS. SKYLIGHT 0" GYP BOARD " ROOF STEEL STUD SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) WALL ESCUTCHEON HOLES THROUGH WALLS SHALL BE A MINIMUM OF IN. LARGER, AND MAXIMUM OF IN. LARGER IN DIAMETER THAN THE OUTSIDE DIAMETER OF THE PASSING THRU THE RATED WALL. THIS SPACE SHALL BE FILLED WITH MINERAL WOOL AND SEALED WITH AN APPROVED LISTED FIRE CAULK OR SEALANT. ALL PENETRATIONS OF FIRE RATED WALLS AND ASSEMBLIES SHALL BE UL LISTED FOR THAT PURPOSE, FOR BOTH THE TYPE OF MATERIAL AND WALL OR CEILING/FLOOR CONSTRUCTION. LISTED ALTERNATE METHODS WILL BE ACCEPTED.. CONTRACTOR SHALL OBTAIN SIGNED OWNER S CERTIFICATE AS PER NFPA AND SPECIFICATIONS.. REFER TO SPECIFICATIONS SECTION 00 FOR ADDITIONAL INFORMATION REGARDING THE FIRE PROTECTION SYSTEM.. SEE PROJECT SPECIFICATIONS FOR SYSTEM TESTING REQUIREMENTS (HYDROSTATIC, TRIP TESTING ETC.).. PIPING:.. SPRINKLER CONTRACTOR SHALL COORDINATE LOCATION OF ALL PIPING AND SPRINKLERS WITH OTHER TRADES, HVAC SYSTEMS IN PARTICULAR. COORDINATION SHALL OCCUR DURING DESIGN AND LAYOUT, AS WELL AS IN THE FIELD... SPRINKLER PIPING SHALL BE ROUGHED IN PRIOR TO OR CONCURRENTLY WITH THE INSTALLATION OF MAJOR DUCTWORK. INSTALLATION OF SPRINKLERS BELOW OBSTRUCTING DUCTWORK MAY OCCUR LATER... SIZING AND ACTUAL ROUTING OF ALL NEW SPRINKLER SYSTEM PIPING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBJECT TO APPROVAL BY THE ENGINEER... WET SYSTEM PIPING AND FITTINGS SHALL MEET THE REQUIREMENTS OF NFPA, EXCEPT THAT PRESS FIT AND POZ LOK SYSTEMS ARE NOT APPROVED FOR THIS PROJECT... ALL PIPING INCH AND LARGER TO BE SCHEDULE 0 STEEL; ALL PIPING INCH AND SMALLER TO BE CPVC EXCEPT AS NOTED BELOW:... ALL EXPOSED PIPING TO BE SCHEDULE 0 STEEL.... ALL LOCATIONS NOT LISTED FOR CPVC SHALL BE SCHEDULE 0 STEEL.... WHERE SUNLIGHT, CHEMICALS, OR PHYSICAL ABUSE COULD BE EXPECTED, ONLY SCHEDULE 0 STEEL SHALL BE USED... PIPING PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED IN ACCORDANCE WITH SPECIFICATIONS (SEE ALSO DETAIL /F00)... PAINTING OF TO BE BY DIVISION. Pyramid Court, Suite 00 Englewood, CO 0 Phone: 0..00 Fax: 0..0 LIGHT COVE CEILING SPACE CEILING SPACE GRID CEILING. HANGERS:.. HANGERS, HANGER RODS, CLAMPS, AND INSERTS SHALL BE IN ACCORDANCE WITH NFPA, 00 EDITION... CPVC HANGERS SHALL BE IN ACCORDANCE WITH MANUFACTURER S GUIDELINES. SEE DETAIL /F00... TRAPEZE STYLE HANGING ASSEMBLIES MAY BE USED, BUT ONLY WITH DOCUMENTATION ON THE SHOP DRAWINGS VALIDATING THE SIZING OF THE TRAPEZE MEMBERS. WHEN A TRAPEZE MEMBER IS NOT EXPLICITLY LISTED IN NFPA (E.G. UNISTRUT), DOCUMENTATION MUST BE PROVIDED THAT INDICATES ADEQUATE SECTION MODULUS AND OTHER PERTINENT PARAMETERS ARE BEING MET.. SPRINKLERS:.. PROTECTION OF SPRINKLERS DURING PAINTING, AND REMOVAL THEREAFTER, SHALL BE BY DIVISION... UNLESS INDICATED OTHERWISE, ALL AUTOMATIC SPRINKLERS LOCATED WITHIN SUSPENDED TILE CEILINGS SHALL BE, RECESSED TO MATCH EXISTING SPRINKLERS. UNLESS OTHERWISE NOTED, REMAINING EXPOSED SPRINKLERS SHALL BE. SEE SPRINKLER LEGEND FOR SPRINKLER TYPE DETAILS... SPRINKLERS SHALL BE LOCATED IN THE CENTER OF TILE. SEE DETAIL /F00... HEAD GUARDS LISTED FOR USE WITH THE RESPECTIVE SPRINKLERS SHALL BE INSTALLED ANYWHERE EXPOSED SPRINKLERS ARE LOCATED BELOW 0" AFF... ELECTRICAL AND MECHANICAL ROOMS SHALL UTILIZE INTERMEDIATE TEMPERATURE RATED SPRINKLERS. " " 0. WATER SUPPLY DATA: CONTRACTOR SHALL BASE HYDRAULIC CALCULATIONS ON THE FOLLOWING WATER SUPPLY INFORMATION: 0.. STATIC: 0 PSI RESIDUAL: 0 PSI FLOWING: GPM 0.. TEST CONDUCTED BY : WESTERN STATES FIRE PROTECTION : 0/0/0 0.. EFFECTIVE POINT: WHERE INCH UNDERGROUND CONNECTS TO INCH UNDERGROUND MAIN. SEE SITE PLAN /F00. 0.. HOSE ALLOWANCES SHALL BE TAKEN AT THIS SAME EFFECTIVE POINT. " USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F00.DWG FEB 0 - :PM XREFS: POST- INSTALLED ANCHOR ALL THREAD ROD HANGER RING SIZE inches " ¼" ½" " ½" " SEE TABLE BELOW FOR NUMBER Hanger 0 0" TO 0" 0 0" TO " 0 0" TO 0" 0 0" TO 0" 0 0" TO 0" 0 0" TO 0 0" CONCRETE FLOOR SLAB CONCRETE TEE POST- INSTALLED ANCHOR ALL ANCHORS AND HANGERS TO BE LISTED FOR USE IN CONCRETE IN ACCORDANCE WITH NFPA, 00 EDITION. OF HANGERS REQUIRED ASTM F CPVC BRANCHLINE * Pipe Length Hangers " TO 0" " TO 0" " TO 0" " TO 0" " TO 0" 0 " TO 0 0" HANGER RING MINIMUM ALLOWABLE HANGERS PER LENGTH OF CPVC * NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER Hangers CLIP ANGLE " TO 0" " TO " " TO 0" " TO 0" " TO 0" 0 " TO 0 0" THE MAXIMUM DISTANCE BETWEEN HANGERS FOR LISTED NONMETALLIC SHALL BE MODIFIED AS SPECIFIED IN THE INDIVIDUAL PRODUCT LISTINGS. ALL THREAD ROD " " " " x BLANK TILES " x TILES LOCATE SPRINKLER AT CENTER OR INCHES FROM THE TWO ADJACENT GRID LINES LOCATE SPRINKLER AT CENTER OF TILE " 0 0 00 " " " " " x SCORED TILES LOCATE SPRINKLER INCHES FROM TWO GRID LINES " EXISTING IN. UG FLOW TEST INFO: STATIC: 0 PSI RESIDUAL: 0 PSI FLOWING: GPM EXISTING HYDRANT EFFECTIVE POINT EXISTING GATE VALVE APPROX. 0 FT OF EXISTING IN. UG EXISTING HYDRANT ELEVATION = 0" FLOOR ELEVATION @ SPRINKLER CONTROLS = 0" EXISTING GATE VALVE EXISTING REMOTE YARD FDC FIRE PROTECTION SYMBOLS LEGEND OH RISER VERTICAL EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING UNDERGROUND PIPING CAP BREAK ORDINARY HAZARD GROUP I AREA ORDINARY HAZARD GROUP II AREA PLAN NOTE FIRE DEPARTMENT CONNECTION (FLUSH TYPE) FIRE DEPARTMENT CONNECTION (SIAMESE TYPE) BACKFLOW TEST OUTLET UNDERGROUND GATE VALVE HYDRANT EXISTING REMOTE YARD FDC CHECK VALVE BUTTERFLY CONTROL VALVE CEILING HEIGHT ABOVE ED FLOOR. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. SP. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED TO FLOW 0 SPRINKLERS OR ENTIRE ROOM WITH MINIMUM END HEAD PRESSURE OF PSI. SPRINKLERS TO BE.K.. ALL REMAINING AREAS TO BE DESIGNED TO LIGHT HAZARD PARAMETERS PER NFPA.. ALL HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM 0 PSI SAFETY FACTOR.. IN ACCORDANCE WITH FM GLOBAL GUIDELINES, AREA REDUCTIONS FOR RESPONSE SPRINKLERS, AND 000.00 0-- SITE PLAN F00 CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 DETAILS FIRE PRO 0.0

SPRINKLER LEGEND SYMB. MFR. PLAN NOTES THD TEMP. SZ RTG. TYPE ESCUT. VK0. RECESSED PENDANT " VK0. RECESSED PENDANT " 00 VK. FLAT CONCEALED PENDANT "MIRAGE" " 00 BRUSHED VK00. UPRIGHT " 00 VK. UPRIGHT VK0. HORIZONTAL SIDEWALL " " VK0. RECESSED HORIZONTAL SIDEWALL " VK0. RECESSED HORIZONTAL SIDEWALL " 00 VK0.0 EXTENDED COVERAGE REC. HORIZ. SIDEWALL " #. PROVIDE AND INSTALL HORIZONTAL SIDEWALL SPRINKLER UNDER OPEN GARAGE DOOR.. PROVIDE INTERMEDIATE OR HIGH TEMPERATURE RATED SPRINKLERS NEAR UNIT HEATER BASED ON NFPA GUIDELINES.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED UPRIGHT SPRINKLERS IN SKYLIGHTS. SEE /F00 FOR DETAILS.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE HORIZONTAL SIDEWALL SPRINKLER POINTING DOWN THE SLOPE IN THE APPROXIMATE LOCATION SHOWN. PIPING TO BE ROUTED AS HIGH AND TIGHT TO WALL AS POSSIBLE. ALL EXPOSED PIPING TO BE SCHEDULE 0 STEEL IN THIS AREA.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED CONCEALED SPRINKLER WITH BRUSHED COVER PLATE IN DISPLAY CASE AS SHOWN.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED RECESSED PENDANT SPRINKLER IN APPROXIMATE LOCATION SHOWN. SPRINKLER PROTECTION NOT REQUIRED IN SKYLIGHT.. PROVIDE AND INSTALL EXTENDED COVERAGE RECESSED HORIZONTAL SIDEWALL SPRINKLER IN APPROXIMATE LOCATION SHOWN. AND ESCUTCHEON TO BE.. NO WORK IN THIS AREA. EXISTING SPRINKLERS.. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE HORIZONTAL SIDEWALL SPRINKLER POINTING DOWN THE SLOPE IN THE APPROXIMATE LOCATION SHOWN. ALL EXPOSED PIPING TO BE SCHEDULE 0 STEEL IN THIS AREA. 0. ROUTE LEVEL DOWN IN CHASE IN THIS APPROXIMATE LOCATION. SP SP SPRNK K S.I.N. RSPNS NO. FCTR INSPECTOR S TEST OUTLET. NOT USED.. NO SPRINKLER PROTECTION REQUIRED BELOW NON COMBUSTIBLE EXTERIOR OVERHANG. SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: Pyramid Court, Suite 00 Englewood, CO 0 Phone: 0..00 Fax: 0..0. CPVC PIPING NOT ALLOWED IN OR ABOVE THIS ROOM.. COORDINATE CROSS MAIN ROUTING WITH EXISTING CONDITIONS.. PROVIDE AND INSTALL CONCEALED SPRINKLER WITH BRUSHED COVER PLATE AS SHOWN.. NO SPRINKLER PROTECTION REQUIRED WITHIN CEILING POCKET. SP OH OH SP OH OH OH OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. EXISTING HOSE CONNECTION OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. OH. ALL AREAS WITH THIS SYMBOL: SP SHALL BE DESIGNED TO FLOW 0 SPRINKLERS OR ENTIRE ROOM WITH MINIMUM END HEAD PRESSURE OF PSI. SPRINKLERS TO BE.K.. ALL REMAINING AREAS TO BE DESIGNED TO LIGHT HAZARD PARAMETERS PER NFPA.. ALL HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM 0 PSI SAFETY FACTOR. USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F0.DWG FEB 0 - :PM XREFS:. IN ACCORDANCE WITH FM GLOBAL GUIDELINES, AREA REDUCTIONS FOR RESPONSE SPRINKLERS, AND remove head?? CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 OH THIS LEVEL LEVEL LEVEL LEVEL 0 PARTIAL MAIN LEVEL DN TO LEVEL FLOOR PLAN FIRE PROTECTION 000.00 0.0 0-- LEVEL UNIVERSITY HALL BUILDING 0 KEY PLAN N.T.S. NORTH SEE /F0 FOR CONTINUATION F0

SPRINKLER LEGEND SYMB. MFR. S.I.N. NO. K FCTR RSPNS TYPE THD SZ TEMP. RTG. SPRNK ESCUT. VK0. RECESSED PENDANT " ROUTE UP TO LEVEL SEE SITE PLAN /F00 FOR CONTINUATION EXISTING IN. UG VK0. RECESSED PENDANT " 00 VK. FLAT CONCEALED PENDANT "MIRAGE" " 00 BRUSHED VK00. UPRIGHT " 00 VK. UPRIGHT " VK0. HORIZONTAL SIDEWALL " VK0. RECESSED HORIZONTAL SIDEWALL " VK0. RECESSED HORIZONTAL SIDEWALL " 00 VK0.0 EXTENDED COVERAGE REC. HORIZ. SIDEWALL " SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: PLAN NOTES #. SPRINKLER CONTROLS. SEE DETAIL /F00.. PROVIDE AND INSTALL () NEW SPARE HEAD CABINETS. ONE HEAD SPARE CABINET TO HOLD THE REQUIRED SPARE SPRINKLERS AND ONE () HEAD CABINET TO HOUSE SPARE COVER PLATES AS SPECIFIED.. PROVIDE HORIZONTAL SIDEWALL SPRINKLER IN ELEVATOR PIT LOCATED NO MORE THAN FT UP FROM PIT FLOOR. PROVIDE FLOW SWITCH WITH VALVE ABOVE CEILING, OUTSIDE ELEVATOR SHAFT. ROUTE TEST/DRAIN PIPING TO EXTERIOR WALL AND OUT. PROVIDE SPLASH BLOCK AT EXTERIOR.. NO SPRINKLERS OR SPRINKLER PIPING ALLOWED IN ELEVATOR EQUIPMENT ROOM. Pyramid Court, Suite 00 Englewood, CO 0 Phone: 0..00 Fax: 0..0. PROVIDE AND INSTALL INTERMEDIATE TEMPERATURE RATED CONCEALED SPRINKLER WITH BRUSHED COVER PLATE IN DISPLAY CASE AS SHOWN.. LEVEL FLOOR CONTROLS LOCATED ABOVE CEILING. SEE /F00 FOR DETAILS.. ROUTE DRAIN PIPING TO EXTERIOR WALL IN APPROXIMATE LOCATION SHOWN. PROVIDE SPLASH BLOCK AT EXTERIOR.. NO WORK IN THIS AREA. EXISTING SPRINKLERS.. FROM LEVEL. ROUTE MAIN ABOVE CEILING TO FLOOR CONTROLS LOCATION SHOWN. 0. UP FROM LEVEL. 0. LEVEL FLOOR CONTROLS. SEE /F00 FOR DETAILS.. NO SPRINKLER PROTECTION REQUIRED BELOW NON COMBUSTIBLE EXTERIOR OVERHANG.. CPVC PIPING NOT ALLOWED IN OR ABOVE THIS ROOM.. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. UP FROM LEVEL (LOWER LEVEL) OH. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED NFPA. SP. ALL AREAS WITH THIS SYMBOL: SHALL BE DESIGNED TO FLOW 0 SPRINKLERS OR ENTIRE ROOM WITH MINIMUM END HEAD PRESSURE OF PSI. SPRINKLERS TO BE.K. USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F0.DWG FEB 0 - :PM XREFS: KEY PLAN N.T.S. UNIVERSITY HALL BUILDING NORTH 0 0 DN FROM LEVEL OH OH SPRINKLERED FROM ABOVE UP TO LEVEL (MAIN/GARDEN LEVEL) SEE /F0 FOR CONTINUATION 0 LEVEL LEVEL. ALL REMAINING AREAS TO BE DESIGNED TO LIGHT HAZARD PARAMETERS PER NFPA.. ALL HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM 0 PSI SAFETY FACTOR.. IN ACCORDANCE WITH FM GLOBAL GUIDELINES, AREA REDUCTIONS FOR RESPONSE SPRINKLERS, AND LEVEL 0 000.00 0-- F0 CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 PARTIAL FLOOR PLANS FIRE PROTECTION 0.0

SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: Pyramid Court, Suite 00 Englewood, CO 0 Phone: 0..00 Fax: 0..0 0 0 USER\PW: REED.ROISUM\M00- O:\PROJECTS\00\0.0\.0 PROJECT EXECUTION\. DESIGN - ENGINEERING\DRAWINGS\0.0 F00.DWG FEB 0 - :PM XREFS: d d d d d a c BUTTERFLY VALVE WITH TAMPER SWITCH. CHECK VALVE b FLOOR CONTROL VALVE ASSEMBLY INCLUDING: a b c d FLOW SWITCH PRESSURE RELIEF VALVE PRESSURE GAUGE WITH WAY VALVE DRAIN TO OUTSIDE WALL TO LEVEL SPRINKLER SYSTEM TO LEVEL SPRINKLER SYSTEM FROM BELOW a c d b ABOVE CEILING SPACE LIGHT FIXTURE (TYP.) CEILING OFFICE 0 d BUTTERFLY VALVE WITH TAMPER SWITCH. CHECK VALVE FLOOR CONTROL VALVE ASSEMBLY INCLUDING: a FLOW SWITCH b PRESSURE RELIEF VALVE c PRESSURE GAUGE WITH WAY VALVE d DRAIN TO OUTSIDE WALL TO LEVEL SPRINKLER SYSTEM ABOVE CEILING SPACE LIGHT FIXTURE (TYP.) OFFICE 0 d d 0 0 0 EXISTING IN. UNDERGROUND WATER LEAD IN. 0 EXISTING IN. UNDERGROUND WATER LEAD IN. 0 EXISTING IN. MAIN. EXISTING IN. 000SS AMES BACKFLOW ASSEMBLY EXISTING MAIN DRAIN EXISTING FLOW SWITCH EXISTING PRESSURE GAUGE EXISTING SYSTEM BUTTERFLY CONTROL VALVE EXISTING WET SYSTEM EXISTING FDC PIPING EXISTING FDC CHECK VALVE EXISTING STAND PIPING NEW BUTTERFLY VALVE WITH TAMPER SWITCH NEW WET SYSTEM. PROVIDE AND INSTALL () NEW SPARE HEAD CABINETS ON WALL NEAR SPRINKLER CONTROLS. ONE HEAD SPARE CABINET TO HOLD THE REQUIRED SPARE SPRINKLERS AND ONE () HEAD CABINET TO HOUSE SPARE COVER PLATES AS SPECIFIED. EXISTING IN. MAIN. EXISTING IN. 000SS AMES BACKFLOW ASSEMBLY EXISTING MAIN DRAIN EXISTING FLOW SWITCH EXISTING PRESSURE GAUGE EXISTING SYSTEM BUTTERFLY CONTROL VALVE EXISTING WET SYSTEM EXISTING FDC PIPING EXISTING FDC CHECK VALVE EXISTING STAND PIPING 0 000.00 0-- F00 CRAGWOOD DRIVE, COLORADO SPRINGS, COLORADO 00 DETAILS FIRE PRO 0.0