TECHNICAL MANUAL *MSS92, *CSS " SINGLE STAGE MULTI-SPEED GAS FURNACE UP TO 92% AFUE

Similar documents
GAS-FIRED WARM AIR FURNACE USER S INFORMATION MANUAL

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

*MEC96 UPFLOW / HORIZONTAL TWO-STAGE GAS FURNACE

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GAS-FIRED WARM AIR FURNACE USER S INFORMATION MANUAL

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GMS9/GCS9 SERIES 93% AFUE

PACKAGE GAS-ELECTRIC USER S INFORMATION MANUAL

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GKS9 40" 90% Gas Furnaces

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

AE/AH R410A Window Air Conditioners & Heat Pumps

DAT SERIES COMMERCIAL AIR HANDLERS INSTALLATION INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

TECHNICAL MANUAL. PBC/PBE/PBH Through-The-Wall R-410A Air Conditioners & Heat Pumps

Service Instructions

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

INSTALLATION INSTRUCTIONS *PD 14 SEER M SERIES - SINGLE PACKAGE

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

INSTALLATION INSTRUCTIONS GPG 16 SEER M SERIES SINGLE PACKAGE GAS-ELECTRIC HEATING & COOLING UNITS

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

INSTALLATION INSTRUCTIONS FOR *CVC96 & *MVC96 TWO-STAGE GAS FURNACE (Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace)

VERTICAL MOUNT AIR HANDLERS

*MEC96 UPFLOW / HORIZONTAL TWO-STAGE GAS FURNACE

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Wt. Lbs Model Number (BTUH) Hz

INSTALLATION INSTRUCTIONS FOR *MSS9* & *CSS9* SINGLE-STAGE GAS FURNACE

AVPTC**14** AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TSTAT0201CW Recommended (sold separately)

AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

MBR BLOWER CABINET INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR *M(H,S)8 / GD(H,S)8 / GHS8 / GME8 ADS(H,S)8 / AMEH8 GAS FURNACE

TSTAT0101SC Recommended (order separately)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Cooling Capacity CFM range

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Cooling Capacity CFM in. w.c. (125 Pa)

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

T9MPV SmartComfort VS90 Product Specifications

AMVM97 (B) / ACVM97 (B)

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TECHNICAL INFORMATION MANUAL

RG7D 1-Stage Heat Series

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

Multi-Position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

13 GEP A L P - 1 A

Bosch BVA Series Air Handler

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

INSTALLATION INSTRUCTIONS

MULTI POSITION GAS FURNACE

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

RGE 13 A T - 1 A

Rheem Classic Series Multi-position Gas Furnaces

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

G6RC Series TECHNICAL SPECIFICATIONS

Transcription:

TECHNICAL MANUAL AL, 34.5" SINGLE STAGE MULTI-SPEED GAS FURNACE UP TO 92% AFUE Refer to Service Manual RS6612012 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual. Refer to the appropriate Parts Catalog for part number information. Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person. RT6612029 August 2014 is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved. Copyright 2014 Goodman Company, L.P.

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. * M S S 9 2 0 6 0 3 B N A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Brand Minor Revision A- Amana Brand G- Goodman Brand A - Initial Release B - 1st Revision Configuration M - Upflow/Horizontal Major Revision C - Downflow/Horizontal A - Initial Release K - Dedicated Upflow B - 1st Revision D - Dedicated Downflow Nox Airflow N - Natural Gas C - Variable Speed/ComfortNet X - Low Nox E - High Efficiency S - Single Speed Cabinet Width A - 14" Gas Valve Stages B - 17.5" M - Modulating C - 21" V - 2 Stage D - 24.5" H - Convertible 2 Stage S - Single Stage Maximum CFM 3-1200 CFM AFUE 4-1600 CFM 92-92% AFUE 5-2000 CFM MBTU/h 040-40,000 060-60,000 080-80,000 100-100,000 120-120,000 HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. 2

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. ACSS920402BN** ACSS920603BN** ACSS920804CN** ACSS921005CN** AMSS920402BN** AMSS920603BN** AMSS920803BN** AMSS920804CN** AMSS920805CN** AMSS921004CN** AMSS921005CN** AMSS921205DN** GCSS920402BN** GCSS920603BN** GCSS920804CN** GCSS921005CN** GMSS920402BN** GMSS920603BN** GMSS920803BN** GMSS920804CN** GMSS920805CN** GMSS921004CN** GMSS921005CN** GMSS921205DN** DANGER CARBON MONOXIDE POISONING HAZARD Special warning for installation of furnaces or air handling units in enclosed area such as garages, utility rooms or parking areas. Carbon monoxide producing devices (such as automobile, space heater, gas water heater, etc.) Should not be operated in enclosed areas such as unventilated garages or utility rooms because of the danger of carbon monoxide (CO) poisoning resulting from the exhaust emissions. If a furnace or air handler is installed in an enclosed area and a carbon monoxide producing device is operated therein, there must be adequate direct outside ventilation. Carbon monoxide emissions can be (re)circulated throughout the structure if the furnace or air handler is operating in any mode. CO can cause serious illness including permanent brain damage or death. DANGER RISQUE D'EMPOISONNEMENT AU MONOXYDE DE CARBONE Avertissement special au sujet de l'installation d'appareils de chauffage ou de traitement d'air dans des endroits clos, tets les garages, les locaux d'entretien et les stationnements. Evitez de mettre en marche les appareils produisant du monoxyde de carbone (tels que les automobile, les appareils de chauffage autonome,etc.) dans des endroits non ventilés tels que les d'empoisonnement au monoxyde de carbone. Si vous devez faire fonctionner ces appareils dans un endroit clos, assures-vous qu'il y ait une ventilation directe provenant de l'exterie. Les émissions de monoxyde de carbone peuvent etre recircules dans les endroits clos, si l'appareil de chauffage ou de traitement d'air sont en marche. Le monoxyde de carbone peut causer des maladies graves telles que des dommages permanents au cerveau et meme la mort. PELIGRO RIESGO DE INTOXICACIÓN POR MONÓXIDO DE CARBONO Advertencia especial para la instalación de calentadores ó maneja oras de aire en áreas cerradas como estacionamientos ó cuartos de servicio. Los equipos ó aparatos que producen monóxido de carbono (tal como automóvil, calentador de gas, calentador de agua por medio de gas, etc) no deben ser operados en áreas cerradas debido al riesgo de envenenamiento por monóxido de carbono (CO) que resulta de las emisiones de gases de combustión. Si el equipo ó aparato se opera en dichas áreas, debe existir una adecuada ventilac ón directa al exterior. Las emisiones de monóxido de carbono pueden circular a través del aparato cuando se opera en cualquier modo. El monóxido de carbono puede causar enfermedades severas como daño cerebral permanente ó muerte. 0140M00020-D The United States Environmental Protection Agency ( EPA ) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. 3

PRODUCT DIMENSIONS AIR DISCHARGE AIR DISCHARG E 28 ¾ AIR INTAKE 2" PIPE LEFT SIDE DRAIN TRAP EXTERIOR HOLES 6½ 2¾ 2 ⅝ 2 CENTER DIMPLE FOR ALTERNATE AIR INTAKE PIPE 3" OD HOLE HIGH VOLTAGE ELECTRICAL OUTLET STANDARD GAS SUPPLY LOCATION A DIMB DISCHARGE C 1⅞ ¾ ¾ 6½ 2 19½ VENT/FLUE PIPE 2" PVC ALTERNATE VENT/FLUE LOCATION RIGHT SIDE DRAIN TRAP EXTERIOR HOLES HIGH VOLTAGE ELECTRICAL OUTLET ALTERNATE GAS SUPPLY ¾ 34 ½ 14 1½ SIDE CUT-OUT 5 9¼ 19 ⅝ 23 24 ⅞ 31 ⅞ 26 ½ 23 21 ⅛ 19 ⅝ 9¼ 5 SIDE CUT-OUT 1⅜ LEFT SIDE VIEW LOW VOLTAGE ELECTRICAL OUTLET 23 1⅞ 2⅜ 2½ CONDENSATE DRAI N TRAP EXTERIOR CONNECTION (RIGHT OR LEFT SIDE) ¾ PVC FRONT VIEW D FOLDED FLANGES E UNFOLDED FLANGES ⅞ LOW VOLTAGE ELECTRICAL OUTLET 1⅞ 2⅜ 2½ RIGHT SIDE VIEW 22 FOLDED FLANGES 23 ½ UNFOLDED FLANGES Model A B C D E 0402BN** 17-1/2" 16" 13-7/8" 12-1/8" 13-5/8" 0603BN** 17-1/2" 16" 13-7/8" 12-1/8" 13-5/8" 0803BN** 17-1/2" 16" 13-7/8" 12-1/8" 13-5/8" 0804CN** 21" 19-1/2" 17-3/8" 16" 17-1/2" 0805CN** 21" 19-1/2" 17-3/8" 16" 17-1/2" 1004CN** 21" 19-1/2" 17-3/8" 16" 17-1/2" 1005CN** 21" 19-1/2" 17-3/8" 16" 17-1/2" 1205DN** 24-1/2" 23" 20-3/8" 10-3/8" 20-7/8" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL Position Sides Rear Front Bottom Flue Top Upflow 0" 0" 3" C 0" 1" Horizonta l 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. 4

PRODUCT DIMENSIONS 1⅜ TOP VIEW 23 2⅝ 1⅞ FRONT VIEW A C 1⅝ 2½ 1⅞ 6½ RIGHT SIDE VIEW ALTERNATE VENT/ FLUE LOCATION 1½ LOW VOLTAGE ELECTRICAL OUTLET 14 SIDE CUT-OU T LOW VOLTAGE ELECTRICAL OUTLET ALTERNATE GAS SUPPLY LOCATION HIGH VOLTAG E ELECTRICAL OUTLET 34 ½ 25⅛ ALTERNATE GAS SUPPLY LOCATIO N SIDE CUT-OU T 14¾ 25⅛ 14⅞ 14¾ 4⅛ 6⅞ 11⅜ 11⅜ 6⅞ LEFT SIDE EXTERIOR DRAIN TRAP HOLE S STANDARD DRAIN TRAP CONNECTION ¾ PVC 28¾ LEFT SIDE VIEW AIR DISCHARGE 2 2½ 3½ D FOLDED FLANGES E UNFOLDED FLANGES FRONT VIEW HIGH VOLTAGE ELECTRICAL OUTLET 2 2⅝ RIGHT SIDE EXTERIO R DRAIN TRAP HOLES 18 ⅛ FOLDED FLANGES 20 ⅛ UNFOLDED FLANGS RIGHT SIDE VIEW AIR DISCHARGE Model A B C D E 0402BN** 17-1/2" 14-5/8" 14" 14-1/2" 16" 0603BN** 17-1/2" 14-5/8" 14" 14-1/2" 16" 0804CN** 21" 18-1/8" 17-1/2" 18" 19-1/2" 1005CN** 21" 18-1/8" 17-1/2" 18" 19-1/2" MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 3" NC 0" 1" Horizonta l 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. 5

FURNACE SPECIFICATIONS 0402BNA 0603BNA 0803BNA 0804CNA 0805CNA 1004CNA 1005CNA 1205DNA Heating Data High Fire Input¹ 40,000 60,000 80,000 80,000 80,000 100,000 100,000 120,000 High Fire Output¹ 36,840 55,260 73,680 73,680 73,680 92,100 92,100 110,520 AFUE² 92 92 92 92 92 92 92 92 Temperature Rise Range ( F) 30-60 35-65 35-65 35-65 25-55 35-65 35-65 35-65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3" No. of Burners 2 3 4 4 4 5 5 6 Circulator Blower Available AC @ 0.5" ESP 1.5-3 1.5-3 1.5-3 3-5 3-5 3-5 3-5 3-5 Size (D x W) 10" x 8" 10" x 8" 10" x 8" 10" x 10" 11" x 10" 10" x 10" 11" x 10" 11" x 11" Horsepower @ 1075 RPM 1/3 1/3 1/3 1/2 3/4 1/2 3/4 3/4 Speed 4 4 4 4 4 4 4 4 Filter Size (in²) Permanent 363 491 654 654 818 818 818 981 Disposable 182 245 327 327 409 409 409 491 Electrical Data Min. Circuit Ampacity 9.6 9.6 9.6 11.7 13.7 11.7 13.7 13.7 Max. Overcurrent Device (amps) 15 15 15 15 15 15 15 15 Shipping Weight (lbs) 109 112 115 137 138 139 140 152 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or tw o PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbow s, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blow er Amps) + ID Blow er amps. Wire size should be determined in accordance w ith National Electrical Codes. Extensive w ire runs w ill require larger w ire sizes.? Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.? Note s All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT Important: Size fuses and w ires properly and make electrical connection in accordance w ith the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedencee over clearances from the enclosure w here accessibility clearances are greater. 6

FURNACE SPECIFICATIONS 0402BNA 0603BNA 0804CNA 1005CNA Heating Data 40,000 60,000 80,000 100,000 High Fire Input¹ High Fire Output¹ 36,840 55,260 73,680 92,100 AFUE² 92 92 92 92 Temperature Rise Range ( F) 30-60 35-65 35-65 35-65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" No. of Burners 2 3 4 5 Circulator Blower 2.5-4 2.5-4 Available AC @ 0.5" ESP 1.5-3 1.5-3 Size (D x W) 10" x 8" 10" x 8" 10" x 10" 11" x 10" Horsepower @ 1075 RPM 1/3 1/3 1/2 ¾ Speed 4 4 4 4 Filter Size (in²) 363 491 654 818 Permanent Disposable 182 245 327 409 Electrical Data 9.6 9.6 11.7 13.7 Min. Circuit Ampacity Max. Overcurrent Device (amps) 15 15 15 15 Shipping Weight (lbs) 109 112 137 140 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or tw o PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbow s, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blow er Amps) + ID Blow er amps. Wire size should be determined in accordance w ith National Electrical Codes. Extensive w ire runs w ill require larger w ire sizes.? Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.? Note s All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT Important: Size fuses and w ires properly and make electrical connection in accordance w ith the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedencee over clearances from the enclosure w here accessibility clearances are greater. 7

AIRFLOW DATA Model 0402BNA 0603BNA 0803BNA 0804CNA 0805CNA 1004CNA 1005CNA 1205DNA Motor Speed (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) Tons AC¹ 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,498 N/A 1,446 N/A 1,368 N/A 1,302 N/A 1,227 N/A 1,145 1,059 954 Med 2.5 1,223 N/A 1,182 N/A 1,153 30 1,099 31 1,051 32 982 901 813 Med-Lo 2 983 35 971 35 945 36 919 37 878 39 813 746 659 Low 1.5 816 42 794 43 758 45 734 46 678 50 637 597 523 High 3 1,494 N/A 1,428 36 1,362 38 1,294 39 1,231 42 1,162 1,076 972 Med 2.5 1,203 42 1,178 43 1,147 45 1,101 46 1,045 49 986 927 831 Med-Lo 2 977 52 965 53 939 54 904 57 866 59 801 763 639 Low 1.5 801 64 786 65 751 N/A 714 N/A 714 N/A 680 635 596 High 3 1,459 47 1,397 49 1,339 51 1,270 54 1,202 57 1,107 1,049 952 Med 2.5 1,191 57 1,166 58 1,137 60 1,086 63 1,033 N/A 973 889 797 Med-Lo 2 985 N/A 967 N/A 932 N/A 900 N/A 859 N/A 805 731 620 Low 1.5 808 N/A 785 N/A 758 N/A 726 N/A 679 N/A 629 590 513 High 5 2,115 N/A 2,050 N/A 1,973 35 1,915 36 1,810 38 1,695 1,587 1,467 Med 4 1,802 38 1,739 39 1,725 40 1,665 41 1,612 42 1,532 1,443 1,320 Med-Lo 3.5 1,517 45 1,509 45 1,496 46 1,475 46 1,441 47 1,388 1,304 1,205 Low 3 1,213 56 1,225 56 1,216 56 1,194 57 1,179 58 1,135 1,084 1,005 High 5 2,284 30 2,231 31 2,170 31 2,103 32 2,037 33 1,945 1,836 1,750 Med 4 1,865 37 1,869 36 1,775 38 1,732 39 1,684 40 1,619 1,548 1,480 Med-Lo 3.5 1,594 43 1,571 43 1,530 45 1,492 46 1,454 47 1,414 1,355 1,293 Low 3 1,411 48 1,366 50 1,325 51 1,296 53 1,251 54 1,200 1,147 1,096 High 5 2,082 41 1,997 43 1,943 44 1,847 46 1,749 49 1,669 1,560 1,443 Med 4 1,823 47 1,782 48 1,711 50 1,659 51 1,574 54 1,513 1,402 1,305 Med-Lo 3.5 1,565 54 1,545 55 1,529 56 1,487 57 1,441 59 1,365 1,287 1,196 Low 3 1,261 N/A 1237 N/A 1,242 N/A 1,216 N/A 1,179 N/A 1,145 1,098 1,034 High 5 2,137 40 2,073 41 2,031 42 1,949 44 1,879 45 1,811 1,734 1,625 Med 4 1,793 48 1,754 49 1,704 50 1,648 52 1,590 54 1,534 1,451 1,371 Med-Lo 3.5 1,558 55 1,518 56 1,477 58 1,425 60 1,376 62 1,316 1,242 1,170 Low 3 1,370 62 1,325 64 1,288 N/A 1,237 N/A 1,191 N/A 1,134 1,086 1,024 High 5 2,256 45 2,192 47 2,133 48 2,054 50 1,986 51 1,907 1,834 1,718 Med 4 1,805 57 1,762 58 1,722 59 1,677 61 1,618 63 1,563 1,507 1,441 Med-Lo 3.5 1,565 65 1,513 N/A 1,480 N/A 1,415 N/A 1,392 N/A 1,346 1,269 1,198 Low 3 1,368 N/A 1,326 N/A 1,278 N/A 1,238 N/A 1,208 N/A 1,165 1,093 1,052 ¹ at 0.5" ESP Note s CFM in chart is w ithout filter(s). Filters do not ship w ith this furnace, but must be provided by the installer. If the All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blow er cooling & heating speed as needed. For most jobs, about 400 CFM per ton w hen cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value show n on the rating plate. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit w ill have approximately the same temperature rise at a particular CFM, w hile ESP at the CFM w ill be low er.

AIRFLOW DATA Model 0402BNA 0603BNA 0804CNA 1005CNA Motor Speed (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 Tons AC¹ 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,400 N/A 1,331 N/A 1,263 N/A 1,189 N/A 1,106 31 1,020 941 843 Med 2.5 1,204 N/A 1,176 N/A 1,121 30 1,072 32 1,002 34 927 853 740 Med-Lo 2 1020 33 998 34 968 35 923 37 880 39 820 739 652 Low 1.5 841 41 827 41 797 43 766 44 727 47 680 634 556 High 3 1,668 31 1,335 38 1,288 40 1,207 42 1,133 45 1,061 955 845 Med 2.5 1,224 42 1,182 43 1,139 45 1,088 47 1,015 50 948 859 759 Med-Lo 2 1030 50 1005 51 988 52 942 54 893 57 830 751 666 Low 1.5 859 60 830 62 815 63 789 65 751 N/A 693 629 556 High 4 1,770 39 1,645 41 1,610 42 1,528 45 1,437 47 1,340 1,251 1,141 Med 3.5 1,690 40 1,615 42 1,531 45 1,470 46 1,393 49 1,308 1,196 1,099 Med-Lo 3.0 1,612 42 1,540 44 1,472 46 1,398 49 1,306 52 1,223 1,132 1,010 Low 2.5 1,396 49 1,339 51 1,304 52 1,250 55 1,170 58 1,092 1,010 906 High 4 1,793 48 1,699 50 1,610 53 1,533 56 1,461 58 1,363 1,247 1,146 Med 3.5 1,693 50 1,622 53 1,552 55 1,467 58 1,390 61 1,320 1,205 1,083 Med-Lo 3.0 1,632 52 1,546 55 1,493 57 1,415 60 1,332 64 1,257 1,148 1,054 Low 2.5 1,429 60 1,380 62 1,334 64 1,258 N/A 1,199 N/A 1,136 1,041 942 ¹ at 0.5" ESP Note s CFM in chart is w ithout filter(s). Filters do not ship w ith this furnace, but must be provided by the installer. If the furnace requires tw o return filters, All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blow er cooling & heating speed as needed. For most jobs, about 400 CFM per ton w hen cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value show n on the The ti above l t chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit w ill have approximately the same temperature rise at a particular CFM, w hile ESP at the CFM w ill be low er. 9

WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. / 10 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.