OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Similar documents
LaserPlus Model LP-OA EDFA OPERATING MANUAL

Product Specification

Product Specification

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Set-Up Procedures. Before You Start

Product Specification

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

The User Manual. 1550nm CATV ERBIUM-DOPED FIBER AMPLIFIER

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PONA 3000 Series High Power EDFA User s Guide

Cooled Butterfly 980nm Pump Laser Module

Features

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

T3/E3 Fiber Optic Line Drivers

CATALOGUE LASER POINTERS

VIEW500 USER-FRIENDLY STANDARD OTDR

Clearlite Photonic Fibers

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

G4 Pulsed Fiber Laser

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

FIRERAY 5000 range USER GUIDE

VIEW500 FASTEST STANDARD OTDR

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

OPTICAL FIBER SOLUTIONS

OPTICAL AMPLIFIERS SELECTION GUIDE

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Recommended Work Area Controls

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

G4 Pulsed Fiber Laser

MINI2 MOST ACCURATE COMPACT OTDR

Wideband Optical Couplers

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

MicrOTDR. Optical Fault Locator. User Manual

Apollo Intelligent Auto Aligning Beam Detector. User Guide

FHO5000 Series Triple-Proof OTDR

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Fiber Optics and Liquid Level Sensors Line Guide

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Instruments Designed for POF & Fibre Optic Cable Testing

Advantages / Characteristics

palmotdr Series Handheld OTDR

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Motorised Infrared Optical Beam Smoke Detector. User Guide


CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Fiber Optical Multiplexer

Four channel video link For low cost video transmission

Noyes OFL 250B Specs Provided by

Motorised Infrared Optical Beam Smoke Detector. User Guide

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

palmotdr Series Handheld OTDR


On-chip optical detectors in Standard CMOS SOI

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

LASER SAFETY BARRIER

More Precision. thicknesssensor // The sensor for precise thickness measurements

Medical Lasers and Laser Safety

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

3kW 6kW, QUBE Fiber Lasers

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Fibre Specification Standards

Field Test Procedure for Optical Fibre Link Measurements

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Rack Mount High-Power EDFA Installation Guide

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Intelligent addressable fire alarm control panel

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

Indium Gallium Arsenide Detectors

TFS-FS1 Optical Leakage Detector. Operation Manual

XPIN -XT X-ray Detector Operation Manual

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Nardalert S3 TM Non-Ionizing Radiation Monitor

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

Diode-Pumped Solid-State Blue Lasers

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

FLX380-30x FlexTester OTDR

Fiber Optic Cable Fence Disturbance Sensor

OWNERS MANUAL OPERATION GUIDE

Transcription:

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL Phone: (209) 586-022 (800) 545-022 Fax: (209) 586-026 E-Mail: salessupport@olsontech.com www.olsontech.com OTEB-CO-B (No SNMP) Rev. X7 /7/200

SAFETY WARNINGS LASER RADIATION The OTEA-CO-B EDFA emits invisible radiation that can cause permanent eye damage. AVOID DIRECT EXPOSURE TO BEAM. Operate the EDFA only with the proper optical fiber installed in the optical connector. Power to the OTEA-CO-B EDFA should be turned off or preferably, disconnected whenever the optical connector cover is opened and there is no installed fiber (as when the fiber connector is being installed or removed from the optical connector). When the amplifier is working in normal state, the output power of light with wavelengths in the invisible range ( infrared light) may exceed +26dBm (400mW). Therefore, to avoid damaging your eyes, do not look into the output port of the EDFAdirectly. NEVER look at the end of the fiber to see if light is coming out. NEVER! Most fiber optic laser wavelengths (30nm and 550nm) are totally invisible to the unaided eye and will cause permanent damage. Always use instruments, such as an optical power meter, to verify light output. Use extreme care with magnifying glasses, microscopes, etc. NEVER look into the output of the EDFA or a fiber connected to an EDFA. NEVER clean an optical connector with optical power present. NEVER look into or use any optical instrument to view the distant end of a fiber that may be connected directly or via an optical splitter, to a transmitter or EDFA that may be operating. This specifically applies to fibers that are to be connected to receivers (such as the OTPN-2000C) or other devices at any distance from the laser transmitter or EDFA. ALWAYS read the product data sheet and the laser safety label before powering the product. Note the operation wavelength, optical output power and safety classifications. If safety goggles or other eye protection are used, be certain that the protection is effective at the wavelength emitted by the device under test BEFORE applying power. ALWAYS connect a fiber to the output of the device BEFORE power is applied. Power should never be applied without an attached fiber. If the device has a connector output, a connector should be attached that is connected to a fiber. This will ensure that all light is confined within the fiber waveguide, virtually eliminating all potential hazard. HIGH VOLTAGE The OTEA-CO-B EDFA contains no user serviceable parts. There is exposed high voltage inside this unit. Only authorized factory service technicians should open the unit with power applied. SHOCK HAZARD The OTEA-CO-B EDFA is designed for indoor use only. Direct exposure to moisture must be avoided. If you have questions about laser safety procedures, please call Olson Technology before powering your product. The fiber amplifier is sensitive equipment. Do not open the case of the amplifier to avoid damaging the internal component devices. Opening the case of the amplifier without the written permission of OlsonTechnology, Inc., will void the warranty.

INTRODUCTION Olson Technology, Inc. provides a wide range of Erbium Doped Fiber Amplifiers (EDFA s), for 550nm HFC networks that feature low noise figure, stable output power and excellent environmental stability. EDFA s are comprised of two main parts: the gain module and the external control system. The gain module amplifies the optical signal in 550nm wavelength band (540-560nm typically). It is made of high quality optical components, and carefully designed to maximize overall performance. Low power EDFA' s may only have a single pump, while high power units can have up to three pumps. The external control system allows the operator to ensure that the gain module is working optimally. Controlled by microprocessor, it monitors the states of the gain module and adjusts all the parameters to ensure a stabilized output power of the gain module. This system also provides warnings via the front panel indicator LED and a digital display. The LCD on the front panel shows the detailed working parameters of the EDFA. This information can also be accessed via the standard RS-232 interface via an external computer. OPERATION PANEL DESCRIPTION

STATUS DISPLAY PANEL OPERATION The microprocessor software monitors the function of a number of system parameters. Press the and buttons to display key working parameters sequentially. Optical Input Power - Input power: INPUT = display input power (dbm) Input power = +0dBm = >alarm Input power = -0dBm => display NO INPUT =>shut down the power supply of the laser. Input power = 0dBm => reach fixed output power. Optical Output Power - Output: OUTPUT = display output power (dbm) Tolerance = ±0.2dBm No input = power supply of the laser will be shut down automatically => display NO INPUT => NO OUTPUT Laser Temperature - Laser temperature: TEMP = laser temp is set to operate in the range of 20-30 C if exceeded => LCD will display READY => red LED indicator will light, and the power supply of the laser will shut down automatically. Laser Bias - Bias: BIAS = Bias is the key index of the laser, if it exceeds the fixed range power supply of the laser, the power supply will be shut down automatically to protect the laser. Laser Heating/Cooling - Cooling/heating: COOLING/HEATING = standard temperature for laser 25 C TEC - Thermoelectric cooler 25 C At high ambient temperatures, the LCD will display => COOLING At low ambient temperatures, the LCD will display =>HEATING Voltage +5V Voltage: +5V READS => ±0.5V alarm -5V Voltage: -5V READS => ±0.5V alarm Serial Number - Displays the serial number of the EDFA. IP Address for RS-232 Connector - The IP address code can be set by the operator via the RS-232 connector on the rear panel.

DESCRIPTION OF STATUS ALARM The front panel indicator LED indicator may be red, green, or off. When the LED is green the EDFA is operating properly. When the LED is off, the unit is off. A red LED indicates an alarm condition. The alarm condition will be displayed on the display panel. With proper power supply, if the EDFA is functioning normally and the LED indicator is red, the digital panel will display READY KEY OFF. Turn on with the key. The display shows KEYOFF for 0 seconds, then the LED indicator changes to green. Pressing the STATUS button displays the following parameters: Input power < -0 dbm, display => NO INPUT; the EDFA cannot be turned on and the LED is red. If any fault listed above has occurred, there will be an alarm. The microprocessor will shut down the laser automatically, and the digital panel will display the cause of the fault. In order to protect the laser, there is a time-delay function. After turning the laser on with the key, the laser will start to work after 0 seconds. NOTES ON OPERATION The EDFA should have good grounding and grounding resistance to 4 Ω. According to the international standard, on an AC three-wire plug, the middle wire is the grounding wire. The EDFAincorporates a high performance, high reliability, switching power supply with over-voltage protection. The microprocessor monitors the output DC voltage. If the fuse blows, the unit should be returned to Olson for service. In order to keep the reflection loss to <-55dB, the EDFA uses SC/APC optical connectors. Other connector types, such as FC/PC, cannot be used with the EDFA. Keep the connector clean when installing the optical cables. Clean it with lint-free tissue with anhydrous alcohol after several rounds of connection/disconnection from the unit. NEVER clean the optical connectors with the unit powered!

EDFA BLOCK DIAGRAM Input Optical Splitter Optical Isolator WDM 550/980 Erbium-Doped Fiber WDM 550/980-490 Optical Isolator Optical Splitter Output Input Power Detector PD Pump Laser 980nm Pump Laser 980/480nm PD Output Power Detector Thermoelectric Cooler Average Power Control Thermoelectric Cooler Front Panel Micro-Processor CPU Control Unit Status Alarm Status Monitor RS-232 Display LCD/VFD Typical Catv CNR Degradation 3.5 3.0 2.5 2.0.5.0 0.5 0.0 0 2 3 4 5 6 7 8 9 0 EDFA Optical Input (dbm)

MODELS AND OUTPUTS Typical Models 5 # of Outputs Output Power (dbm) 5 6 6 7 7 8 8 9 9 20 20 2 2 22 22 23 23 24 24 22 2 2 49 4 9 SPECIFICATIONS Optical Characteristics (with SM 9/25µm Fiber) Min Typ Max Units Operating Wavelength 540 560 nm Input Power Range -0 +0 dbm Max. Alarm 0 dbm Min. Alarm -0 dbm Output Stability -0.3 +0.3 db Noise Figure (0dBm In) < 4.5 < 5.0 < 5.3 db Noise Figure (6dBm In) < 5.5 < 6.0 < 6.5 db Polarization 0.2 db PMD 0.5 ps Reflection Loss 40 db Optical Connector SC/APC Network Interface RS-232/RJ45 NOTES: ) Non-condensing. Electrical & Environmental Characteristics Min Typ Max Units Operating Temp. Range +5 +45 C Storage Temp. Range 0 +55 C Relative Humidity 0 90 % P. S. Voltage +85 +264 VAC P. S. Voltage -48 VDC Power Consumption 50 W

[BLANK PAGE]