Operation Manual. ParaBeam 400/200 Series. ParaBeam 400 Center Mount. ParaBeam 400 Pole-Op

Similar documents
54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Ceiling Fan Installation Instructions

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

Ceiling Fan Installation Instructions

Aurora. MODERN FAN COMPANY Customer Service M-F 8am - 4pm (PST) (ph)

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

LYRA DMX Lyra Bi-Color DMX Flat Panel Light

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

Ceiling Fan Installation Instructions

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

installation and operation manual for Hunter Ceiling Fans

Ceiling Fan Installation Instructions

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

THE CAPRI VII CEILING FAN INSTALLATION INSTRUCTIONS

LYRA DMX Lyra Bi-Color Studio Light with DMX Control

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

USER MANUAL Table of Contents

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

GRANDE OWNER S MANUAL

CEILING FAN OWNER'S MANUAL

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.


SUPRA 52. U.S. Patents: D450,830 INSTRUCTION MANUAL WARRANTY CERTIFICATE

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

LPCMPIRM65 & LPCMPIRDSI65

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

SPECTRE BY. D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

CEILING FAN OWNER'S MANUAL

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling Fan Installation Instructions

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Owner s Guide and Installation Manual

Integrated PIR detectors

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

FerronTM. Instruction Manual A Kichler Decor ceiling fan

CEILING FAN OWNER'S MANUAL

USER MANUAL Table of Contents

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

Burgess 54" Ceiling Fan with Remote Control Owner s Manual

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

, ,

48 TAYLOR CEILING FAN

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

Manuel Guide Lighting Fixtures

Instruction Manual for Electric Ovens OO757X OO986X

JAVA BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

ST. KITTS CEILING FAN

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

Tommy Bahama INDOOR/OUTDOOR 52 in. / 132 cm. CABRILLO COVE CEILING FAN

GROTON. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

CEILING FAN OWNER'S MANUAL

STRATA BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

LPC3BSP65 & LPC3BDP65

ALUMA WET BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

SUPRA 44 WITH LIGHT KIT BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

Hanson LED C e i l i n g F a n

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Ceiling Fan Installation Instructions

TOUCHDOWN 48 CEILING FAN

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

Owner s Guide and Installation Manual

To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

To register your fixture, please visit our website: MonteCarloFans.com NEED HELP? NECESITA AYUDA? AVEZ-VOUS BESOIN D AIDE?

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

LED RETROFIT CONVERSION KITS

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

LUCCI AIRFUSION RESORT DC CEILING FAN

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

WAILEA OWNER S MANUAL

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

Transcription:

Operation Manual ParaBeam 400/200 Series ParaBeam 400 Center Mount ParaBeam 400 Pole-Op Part No. 3100026 Rev D 01-04-2010

x ParaBeam Fixture Styles and Features ParaBeam Center Mount PAR-400S-120 ParaBeam 400 Select DMX Center Mount, 120VAC PAR-400S-230 ParaBeam 400 Select DMX Center Mount, 230VAC PAR-200-120 ParaBeam 200 DMX Center Mount, 120VAC PAR-200-230 ParaBeam 200 DMX Center Mount, 230VAC ParaBeam Yoke Mount PAR-400Y-120 ParaBeam 400 Select DMX Yoke Mount, 120VAC PAR-400Y-230 ParaBeam 400 Select DMX Yoke Mount, 230VAC PAR-200Y-120 ParaBeam 200 DMX Yoke Mount, 120VAC PAR-200Y-230 ParaBeam 200 DMX Yoke Mount, 230VAC 2 2

ParaBeam Pole-Op Mount PAR-400P-120 ParaBeam 400 Select DMX Pole-Op Mount, 120VAC PAR-400P-230 ParaBeam 400 Select DMX Pole-Op Mount, 230VAC PAR-200P-120 ParaBeam 200 DMX Pole-Op Mount, 120VAC PAR-200P-230 ParaBeam 200 DMX Pole-Op Mount, 230VAC Included w/ All ParaBeam Models GFR-P4 ParaBeam 400 Gel Frame (Included) GFR-P2 ParaBeam 200 Gel Frame (Included) LVR-P4-S ParaBeam 400 Silver Louver (Included) LVR-P2-S ParaBeam 200 Silver Louver (Included) True Match Lamps 55C-K29 55W Kino KF29 Compact 55C-K32 55W Kino KF32 Compact 55C-K55 55W Kino KF55 Compact 3

ParaBeam Center Mount Kits KIT-P4-S120 ParaBeam 400 DMX Kit, 120VAC KIT-P4-S230 ParaBeam 400 DMX Kit, 230VAC Kit Contents: 1 ParaBeam 400 DMX Center Mount 1 Lamp Case 1 Ship Case Dimensions 30 29.5 x 12.5 x 11 x 29.5" 30.5" (76 (75 x 32 28 x 77.5cm) 75cm) Weight 61lb (27.5kg) KIT-P2-120 ParaBeam 200 DMX Kit, 120VAC KIT-P2-230 ParaBeam 200 DMX Kit, 230VAC Kit Contents: 1 ParaBeam 200 DMX Center Mount 1 Lamp Case 1 Ship Case Dimensions 21.5 35.5 x 12 11.5 x x 23" 29" (54.6 (90 x 30.5 x 29.2 x 58.5cm) x 73.6cm) Weight 45lb (20.3kg) 4

Inserting Lamps Open hinged reflector door. Insert lamp end first. Snap lamp pins into Close reflector door. To release lamps, press Lamp holder. Red button and lift lamp out. Inserting Louvers, Diffusers or Gel Frame Push tab down and forward to lock into open position. Insert gel frame and diffuser (optional accessory) into channel closest to lamps. 5 5

Silver Louver fits into front channel. All 4 retaining tabs must be extended to lock accessories in place. ParaBeam Center Mount The ParaBeam 400 Center Mount can hangs hang from from a grid a grid by a by Junior a Junior pipe pipe hanger hanger or mounts on on a a Junior Stand. Note: Loop the safety chain through the handle on the ParaBeam 400. The ParaBeam 200 Center Mount can hangs hang from from a grid a grid by a by baby a baby pipe pipe hanger hanger or mounts on on a a baby stand. 6

A 180 degree turn is all that is required to loosen the mount for orientation. To adjust the tension on the lock lever, pull handle away from mount. This disengages the handle from the screw mechanism and allows the lever to be reoriented. You can also use a screwdriver to adjust the tension. Pull back on handle and adjust screw. Beam Angle Orientation Vertical beam angle Horizontal beam angle 7

Correct Lamp Orientation VERTICAL MODE: Follow the principle of lamp base up and lamp tip down. This orientation keeps the mercury away from the cathodes and provides best color temperature stability and best color rendering. DO NOT operate fixtures with lamp base in the down position. Color can diverge up to 400K and will get very green. HORIZONTAL MODE: Even in the horizontal position a slight rotation favoring the lamp tips (lamp base higher than the lamp tip) will allow for better color temperature stability. Note: When looking at the back of the fixture the Kino Flo Logo should read: If the Logo is upside down, the fixture does not have the correct orientation. 8

ParaBeam Yoke and Pole-Op Mount The Yoke has a ½ hole to accept industry standard mounting hardware. The ParaBeam 400 Yoke Mount can hang from a grid by a junior pipe hanger using a Junior Pin Assembly (MTP-I80) sold separately. The ParaBeam 200 Yoke Mount can also hang from a grid by a junior pipe hanger using a Junior Pin Yoke Assembly (MTP-I80) or a baby pipe hanger using a Baby Receiver Yoke Assembly (MTP-I40) also sold separately. The MTP-I80 includes a long bolt for the ParaBeam 400 Yoke Fixture and a short bolt for the ParaBeam 200 Yoke Fixture. Note: Because of weight capacity, the MTP-I40 can only be used on the ParaBeam 200 Yoke Fixture. The ParaBeam 400 and 200 Pole-Op Mount include a yoke with an attached junior pin. They can be hung from a grid with a Junior pipe hanger. Junior pin attached to Pole-Op Yoke 9

Pole Operation The Blue cup alters the Pan (left or right). right.) The White cup alters the Tilt (up or down.) down). Mounting Barn Doors SIDE DOORS First apply Side Doors by inserting the hinge bracket into the extruded edge. Lock the bracket by turning the silver thumbscrew. TOP & BOTTOM DOORS Position the Top and Bottom Doors to allow for sufficient movement. movement. HINGE TENSION ADJUSTMENT Hinge tension on Top & Bottom Doors is adjusted by tightening the nut. Top & Bottom Door 10 Side Door Use a screwdriver to adjust the Side Doors 10

Fixture Operation Warning! To Ensure Proper Operation ALWAYS TURN OFF THE FIXTURE BEFORE connecting or disconnecting lamps. After the lamps are properly installed, the Ballast can be turned on. Avoid operating in temperatures above 125 F (51 C) or below 60 F (15 C). In temperatures below 60 F or 15 C the ballast may take longer to strike. If lamp does not strike within 5 seconds, switch the ballast to OFF, and try again. Check that the lamps are properly seated and the dimmer is up full, then restrike. If temperatures are too low, try to warm up the fixture to at least 60 F. Lamps will turn on at preset dimmer settings as long as the temperature is above 60 F or 15 C. ParaBeam 400 Select Control Panel DMX / MANUAL Lamp Select: Sets the fixture for 2 or 4 lamp operation. DMX Address: Sets DMX address of Fixture. DMX Indicator: Lights if valid DMX signal is present. Remote Dimmer Jack: Hand held dimmer control input jack DMX-In & DMX-Out: DMX-in receives DMX signals from Dimmer Board. DMX-Out relays DMX signal through to other fixtures or Instruments. End of Line: Terminates DMX signal at the end of Fixture series. Dimmer Control: Rotary dimming control Power Switch: Turns fixture on and off. 11

Manual Operation The on-board dimmer dial can manually dim lamps. The REMOTE DIM jack enables the use of a handheld remote control dimmer (Part # DIM-5, Hand Held Dimmer). The MANUAL DIM LAMPS switch selects 2 or 4 lamp operation. In the 2 setting the center two lamps are dimmed. In the 4 setting all four lamps are dimmed. Note: All manual controls are disabled as soon as the DMX cable is applied. For Manual control with DMX cables plugged in, sett address to 000. There is a 5 second delay when switching between DMX and Manual control. DMX Operation DMX Addressing Prior to hanging any instruments set the DMX address of each Fixture. Push the tabs above or below the number window to set the address. (Valid addresses range from 001 to 512.) The light above the address block will illuminate if a DMX signal is present. The DMX DIM CHANNELS feature allows user to select two sets of lamps for DMX dimming control. The ParaBeam 400 Select operates on one or two DMX addresses. Position 1 requires one DMX address and renders control of all four lamps on one dimmer channel. Position 2 requires two DMX addresses to control 4 lamps on two addresses and two dimmer channels. The 1 st address controls the inner two lamps. The 2 nd address controls the outer two lamps. 12 12

Tip: Position 2 allows for a greater degree of control. The board operator can turn two lamps off (1 f-stop drop in exposure) without shifting the color temperature. The ParaBeam 200 operates on one address per fixture. Two lamps are dimmed on one dimmer channel. The END OF LINE switch must be set to open ( O ) on Fixtures within the DMX chain. Set to END OF LINE when the Fixture is the last DMX control device in the chain. Note: When the last Fixture's DMX Term is set to END OF LINE, it will absorb all energy in the DMX line, ensuring DMX signals are transmitted correctly. If a signal is not terminated, it is called a Reflected Wave, and may create transmission errors by causing valid DMX signals to be canceled. ParaBeam Fixtures can be jumpered using the IN and OUT ports. As many as 100 Fixtures can be jumpered on one chain as long as the DMX cable run remains under 1000 feet or 40 x 25ft DMX cables. Note: When operating Fixtures at great distances from the dimmer board, it is recommended to use Opto-Isolators to provide DMX signal amplification. NOTE: If a Fixture or Ballast loses its DMX signal it will hold its last DMX command. For this reason it is important to turn a Fixture or Ballast off using the DMX commands. For example, if you try to turn off the lights by turning off the dimmer board the lights will remember their last DMX command and stay on. The Fixtures or Ballasts require a DMX Off or Black-out command in order to turn off. 13

Trouble Shooting LAMPS FAIL TO LIGHT: With the power switch in the ON position, the red light should be on. If it is not, Voltage is not present. Check your power feed. Check the fuse on the fixture and replace if necessary (5 x 20mm, T3.15AH/250V, Time Delay Type) Replace lamp or lamps. Check ballast contact. Make sure ballast is properly seated; lock tab must be locked in place (see checking ballast notes). After having checked that lamps and ballasts are correctly seated, turn off power to the fixture for 60 seconds and restart. Replace ballast card with one that is known to work. With DMX cable connected, if yellow light is off, there is no DMX signal. Establish a valid DMX signal. With DMX cable plugged in and yellow indicator on: 1. Address must be between 001 and 512. Addresses above 512 are invalid. 2. The dimmer setting on the lighting board must be in the full up mode. 3. The last fixture must have the DMX termination switch set to END of LINE. Numerous terminated fixtures on a DMX run will result in DMX signal corruption. CHECKING BALLAST: Pull out 3 white push-pins. Remove end cover with white push-pins. Push up lock tab and pull out ballast card. The ballast is mounted to a circuit board with end contacts to allow for rapid ballast replacement without the use of additional tools. Lock tab must be locked for proper ballast contact. Note: On ParaBeam 200 Yoke and ParaBeam 200 Pole-Op, the Yoke will need to be removed to access ballasts. 14

Accessories BRD-P4 ParaBeam 400 Barndoors (set of of 4) 4) BRD-P2 ParaBeam 200 Barndoors (set of of 4) 4) DFS-P4..ParaBeam 400 Diffuser DFS-P2..ParaBeam 200 Diffuser DIM-5 Remote Dimmer KAS-P41 ParaBeam 400 400 Center Ship Ship Case KAS-P21 ParaBeam 200 200 Center Ship Ship Case KAS-CL6 6-Lamp Carry Case (55W Compact) MTP-LMT.. Kino Kino 81 81 Lollipop w/ w/ Junior Junior Pin Pin Straight (for (for Center Mount Mount only) only) 15 15

MTP-I80. Junior Pin Yoke Assembly MTP-I40..Baby Receiver Yoke Assembly LVR-P445. ParaBeam 400 Louver 45 LVR-P460. ParaBeam 400 Louver 60 LVR-P490.. ParaBeam 400 Louver 90 LVR-P245. ParaBeam 200 Louver 45 LVR-P260. ParaBeam 200 Louver 60 LVR-P290.. ParaBeam 200 Louver 90 55C-K29 55W Kino KF29 Compact 55C-K32 55W Kino KF32 Compact 55C-K55 55W Kino KF55 Compact 16

Fixture Specifications PAR-400S ParaBeam 400 Select DMX Center Mount Power: 120VAC or 230VAC Amperage: 2 amps at 120VAC 1.1 amps at 230VAC ParaBeam 400400S Center Weight: with lamps and louver 24.2 lbs / 10.9kg Dimensions: 24.5 x 24 x 8 (62 x 61 x 20.5cm) Lamp types: 55 watt compact fluorescent lamps with 2G11 base Switching: 2 lamp and 4 lamp on/off Manual and DMX dimming PAR-200 ParaBeam 200 DMX Center Mount Power: 120VAC or 230VAC ParaBeam ParaBeam 200 Center 200 Amperage: 1.1 amps at 120VAC 0.6 amps at 230VAC Weight: with lamps and louver 16.5 lbs / 7.4kg Dimensions: 24.5 x 13.5 x 7.5 (62 x 34.5 x 19cm) Lamp types: 55 watt compact fluorescent lamps with 2G11 base Switching: 2 lamps on/off Manual and DMX dimming 17

PAR-400Y ParaBeam 400 Select DMX Yoke Power: 120VAC or 230VAC ParaBeam 400 400Y Yoke Amperage: 2 amps at 120VAC 1.1 amps at 230VAC Weight: with lamps and louver 24.2 lbs / 10.9kg Dimensions: 29.5 x 26.8 x 6 (75 x 68 x 15.2cm) Lamp types: 55 watt compact fluorescent lamps with 2G11 base Switching: 2 lamp and 4 lamp on/off Manual and DMX dimming PAR-200Y ParaBeam 200 DMX Yoke Power: 120VAC or 230VAC ParaBeam 200 200Y Yoke Amperage: 1.1 amps at 120VAC 0.6 amps at 230VAC Weight: with lamps and louver 16.5 lbs / 7.4kg Dimensions: 29.5 x 15.8 x 6 (75 x 40 x 15.2cm) Lamp types: 55 watt compact fluorescent lamps with 2G11 base Switching: 2 lamps on/off Manual and DMX dimming 18

PAR-400P ParaBeam 400 Select DMX Pole-Op Power: 120VAC or 230VAC ParaBeam 400400P Pole-Op Amperage: 2 amps at 120VAC 1.1 amps at 230VAC Weight: with lamps and louver 24.2 lbs / 10.9kg Dimensions: 30 x 26.3 x 6 (76.2 x 66.7 x 15.2cm) Lamp types: 55 watt compact fluorescent lamps with 2G11 base Switching: 2 lamp and 4 lamp on/off Manual and DMX dimming PAR-200P ParaBeam 200 DMX Pole-Op Power: 120VAC or 230VAC ParaBeam 200200P Pole-Op Amperage: 1.1 amps at 120VAC 0.6 amps at 230VAC Weight: with lamps and louver 16.5 lbs / 7.4kg Dimensions: 30 x 15.8 x 6 (76.2 x 40 x 15.2cm) Lamp types: 55 watt compact fluorescent lamps with 2G11 base Switching: 2 lamps on/off Manual and DMX dimming 19

For latest Warranty information and Certifications, see Kino Flo website at www.kinoflo.com. Environmental: Disposal of Old Electrical & Electronic Equipment. This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. This product is made of recyclable materials and should be disposed of in accordance with local and state regulations. Kino Flo, Inc. 2840 N. Hollywood Way, Burbank, CA 91505, USA Tel: 818 767-6528 website: www.kinoflo.com