Viewguard Motion detctors PIR and DUAL detectors

Similar documents
561-MB256 plus. Intruder alarm control panel. Performance features

561-MB48. Intruder Alarm Control Panel

IDENTLOC. Intrusion Detection Systems. Performance Features

Description. Optex Incorporated

IDENTLOC. Intrusion Detection Systems. Performance Features

Integrated security systems. The security spectrum Systems for comprehensive building security

Advanced DIGITAL Wired PIR Motion Detector

English. Italiano. Português. Françias. Español

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

Line Smoke Detector LRMX

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

SECURITY PRODUCTS CATALOGUE

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Infrared Ceiling Mount Sensor

HX-80NRAM. High Mount Outdoor Detector

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

D-TECT Dual Tech. GJD360 Triple Technology External Detector

International Customer Edition Date: June 2014

Intrusion Outdoor Protection Perimeter

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Extended Range DUAL TEC Motion Sensor

Motion sensor technologies. Leading by technology

Intrusion sensors. We listened to you

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Leading by technology

D-TECT 3 IP. GJD260 IP Motion Detector

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

>WIRELESS> ALARM SYSTEM CR200

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

KwêBeams Effective wire free outdoor early warning system

DD205RF/TX Detector Installation Sheet

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Movement Detector GJD 300

1125 PIR Motion Detector

D-Tect 2 GJD300 Quad PIR Movement Detector

Made possible by an innovative licensing scheme, which allows individual hardware configuration, up to the maximum configuration:

Infrared Ceiling Mount Sensor

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

Open-area Smoke Imaging Detection (OSID)

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

IP65 High Bay Dual Sense Sensor

Bosch Smart Home. Motion Detector Instruction Manual

FCS-320-TM Series Conventional Aspirating Smoke Detectors

FR-A180 FR-A360. Occupancy detector. Use

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Quick Selection Guide Intrusion Detectors

Sensors and Detectors

Open-area Smoke Imaging Detection (OSID)

D-TECT 2 IP. GJD230 IP Motion Detector

Table of Contents. Intrusion Detectors... I-1. Intrusion Panels... II-1. Type Index... III-1

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Knürr RMS Compact II. Knürr RMS Compact II 2.81

DI601AM Outdoor PIR/AM Detector Installation Sheet

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Internal motion detectors by Siemens Range and application overview Building Technologies

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Flash 3 times per 3 seconds: Under voltage indication, please

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Detector Application Notes

COMPACT FLAME CONTROLLER CFC 2000

Devices for Special Applications

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

DS7400Xi Addressable Control/ Communicator

IP65 High Bay Dual Sense Sensor

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

ABB STOTZ-KONTAKT GmbH Webinar ABB i-bus KNX Security Module SCM/S

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Increased safety and reducing energy consumption with the motion control RPI 01

MKTCTBLEFURTINC R001. Catalogue nd Edition

COMPACT FLAME CONTROLLER CFC 1000

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

Infrared Single Light Barrier. Mounting Instructions DO560

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

SYSTEMS GROUP. May Zilog and EE-SGI Present. epir TM. The Next Generation of PIR Motion Detector Technology. (Over View)

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

Motion Detectors. Whatever the application, there s a Paradox motion detector that will suit your needs and surpass your expectations.

Passive Infrared Motion Detector 5420/90P. Installation Instructions

LPCMPIRM65 & LPCMPIRDSI65

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

OH110, OP110, HI110 Automatic fire detectors

Intrusion. Outdoor protection perimeter

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Alarm System SECURE AS 302

Infrared Wall Mount Occupancy Sensor

esserbus -PLus maximum security, minimum costs

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Motion Detectors for Larger Rooms and Areas

WHAT S IN THE BOX? The IQ Panel also includes a snap on table stand and power supply with cable.

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Parameterisable compact fault annunciator with permanent display

Transcription:

Motion detctors and DUAL detectors Passive infrared sensor Passive infrared and microwave sensor AM DUAL AM DUAL Variations detectors: - AM /BUS-1 VdS Class C EN 5131-1 and EN 5131-2-2, grade 3 - /BUS-1 VdS Class B EN 5131-1 and EN 5131-2-2, grade 2 - AM VdS Class C EN 5131-1 and EN 5131-2-2, grade 3 - VdS Class B EN 5131-1 and EN 5131-2-2, grade 2 VdS approval no. see page 7. Variations DUAL detectors: - DUAL AM /BUS-1 VdS Class C EN 5131-1 and EN 5131-2-4, grade 3 - DUAL /BUS-1 VdS Class B EN 5131-1 and EN 5131-2-4, grade 2 - DUAL AM VdS Class C EN 5131-1 and EN 5131-2-4, grade 3 - DUAL VdS Class B EN 5131-1 and EN 5131-2-4, grade 2 The detectors are suitable for intrusion alarm panels with /BUS-1- or conventional connection technology and are available with or without Anti-Mask function (monitoring against covering). To ensure optimum detection, detectors are equipped with high-quality mirror optics. Standard equipment includes a mirror for area optics. The detectors are motion detectors based on the passive infrared principle. If required, the detectors can be retrofitted on site to long-range optics or curtain optics with accessories that are available separately. The DUAL motion detectors comprise two sensor systems that operate independently: Passive infrared sensor and microwave sensor. The functioning principle of the detector is based on an intelligent linking of the two sensor systems. This type of linking renders the detectors particularly insensitive to air and thermal turbulences. Their distinguishing features being optimum alarm detection and extremely high false alarm security.

Features Anti-Mask function (only AM detectors) Detects covering, spraying or taping of the foil. LED indication Clearly arranged indication of operating state via two LEDs. Walktest indication. -logic (First alarm indication, all types) The detector that is triggered first, can be identified with the aid of the LED indication. Walk test function Easy way to check function and detection area. Detector zone input (only BUS detectors) Integration of contacts/potential-free detectors in the / BUS-1 system (zone not erasable). Microwave sensor (only DUAL detectors) Can be deactivated in the "disarmed" state. Function overview detectors motion detectors Function overview AM Type / BUS-1 / BUS-1 Item no. 3333.1 33332.21 3343.1 33432.21 VdS approval As per EN 5131-2-2 Functions Operating mode Class B Grade 2 EL Class B Grade 2 BUS-1 Class C Grade 3 EL Class C Grade 3 Area optics (state of delivery) Convertible to long-range or curtain optics Anti Mask uo to approx.ca.3 cm (AM) X X X X X X Anti Mask active or inactive in armed state X X Anti Masc automaticallyinactive in armed state X X X Anti Mask allways ative X Alarm indication after disarming X X X X X X X X X X First alarm indication via interval LED indication X X X X X X Alarm memory X X X X X X X X X X sensitivityprogrammable in 2 stages range programmable in 4 stages Detector group input (without clear function) X 2) X 2) Temperature alarm, alarm thresholds can be programmed X X Walk test function (with LED indication) Walk test activation directlythrough the panel X X X X Walk test activation via "clear detector group" X X X X X X Walk test automaticallyactive after initialising is completed X X Cyclical self-test ( function) X X X X X X Monitoring of operating voltage Fault message to the panel X X 3) X X X X X 3) X X X Fault/cover signal: save or don't save X X X X X X X X X Fault/cover signal: onlydon't save X X X Cover contact/tear-off protection X X X X X X EL 2) 3) EasyLogic mode. Onlyoperating voltage and alarm output used (not as per VdS) mode on is supported from panel software V7 (HB/MB24, HB/MB48, MB1). Operation on BUS-1: The detector group is connected in an "OR" function with the alarm message The "Alarm" and "Fault" outputs can be connected in series. BUS-1

Detection range Range programmable in four stages. Detection sensitivity Sensitivity programmable in two stages. Save fault / do not save fault Save: Fault is saved until it is cleared. Do not save: Fault signal is reset automatically after eliminating the fault. Self-test (only AM detectors) Correct functioning of the detector is monitored in cycles. Monitoring of operating voltage Fault message if the operating voltage drops to low. Temperature measurement (only application) Temperature alarm if ambient temperature is too high/too low. Programmable alarm thresholds. Tear-off protection/cover contact Function overview DUAL detectors DUAL motion detectors Function overview V iewguard DUAL V iewguard DUAL AM T ype Item no. VdS approval As per EN 5131-2-4 Functions Area optics Anti M ask uo to approx. ca. 3 cm (AM ) Anti M ask active or inactive in armed state Anti M asc automatically inactive in armed state Anti M ask allways ative Alarm indication after disarming First alarm indication via interval LED indication Alarm memory sensitivity programmable in 2 stages M W sensitivity programmable in 2 stages M W sensitivity automatically as sensitivity range programmable in 4 stages M W range O perating mode F A I 33441.1 Class B Grade 2 Grade 2 EL B US-2/ B US-1 33443.21 BUS-1 Class C EL X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X BUS-1 and M W operate automatically with the same range M W active or inactive in disarmed state X X M W automatically inactive in disarmed state X X X X X X X X M W allways ative X X Detector group input (without clear function) X 2) X 2) Temperature alarm, alarm thresholds can be programmed X X Walk test function (with LED indication) Walk test activation directly through the panel X X X X Walk test activation via "clear detector group" X X X X X X Walk test automatically active after initialising is completed X X Cyclical self-test ( function) X X X X X X Cyclical self-test (M W function) X X X in preparation M onitoring of operating voltage Fault message to the panel X X 3) X X X X X 3) X X X Fault/cover signal: save or don't save X X X X X X X X X Fault/cover signal: only don't save X X X Cover contact X X X X X X Tear-off protection X X X X X EL 2) 3) Easy Logic mode. Only operating voltage and alarm output used (not as per VdS) mode on is supported from panel software V7 (HB/M B24, HB/M B48, M B1). Operation on BUS-1: The detector group is connected in an "OR" function with the alarm message The "Alarm" and "Fault" outputs can be connected in series. Class B F A I 3344.1 Grade 3 B US-2/ B US-1 33442.21 Class C Grade 3

Detection coverage Area optics Optics Area optics with sneak-by guard (state of delivery) Lens splitting 22 zones at 5 levels Opening angle 8 hor., 64 vert. Range 8 / 11 / 13 / 15 m ( and MW operate automatically with the same range) Mounting height Recommended: Permitted: 9m MW 2.5 m for optimal operating sensitivity. ATTENTION! Important note for mounting heights of more than 3. m: In case of mounting heights of 3. to 3.4 m, the close range between - 1.5 m cannot be monitored completely despite the requirements for VdS systems of class C (see detection coverage diagram on right side). As the case may be, the respective areas must be monitored separately by appropriate means (such as a second detector). Detection diagrams 2.2 m to 3.4 m detectors 2.2 m to 4. m DUALdetectors The following diagrams refer to a range setting of 15 m. Note: The detectors have a high immunity against false alarms without reference surface 1. Mounting height 2.5 m ( 2.2 to 3. m) 4 2. Mounting height 3.2 (3. m to 3.4 m Vertical detection coverage Vertical inclination 3 downward 3.2m 9m 12m 3. Mounting height 3.7 (3.4 m to 4. m) (only DUAL detectors) MW MW Expected direction of motion 4 4 4 9m 12m 9m 9m 12m 15m Due to the additional microwave, the dual detector has a very high detection capacity even with diagonal movement. Vertical detection coverage Vertical inclination 2.5m Expected direction of motion 4 Vertical detection coverage, vertical inclination 7 downward 3.7m Expected direction of motion 4 9m 1m m 9m 12m 15m 9m 1m

Detection coverage Replacement Mirror sets The Replacement Mirror sets are not suitable for DUAL detectors. approval in combination with all VdS approved detectors (approval no. see page 7). - Class B - AM Class C Curtain optics 33434 mirror, Curtain optics (PU = 3 piece) The curtain mirror is suitable for monitoring possible intrusion locations. mirror distribution 11 zones on 11 levels acceptance angle 7.5 hor., 85 vert. range 17 / 21 / 25 / 3 m Mounting height: - Recommended: 2.5 m - Permitted: 2.2 m to 3. m.5m.5m Vertical detection coverage, Mounting height 2.5 m 2.5m 5m 1m 15m 2m 25m 3m Vertical inclination 5m 1m 15m 2m 25m 3m Long-range optics 33435 mirror, Long-range optics (PU = 3 piece) The long-range mirror is suitable for monitoring corridors. mirror distribution 8 zones on 6 levels acceptance angle hor., 78 vert. range 29 / 35 / 42 / 5 m 1.5m 1.5m Vertical detection coverage, Mounting height 2.5 m. Vertical inclination 2.5m 1m 2m 3m 4m 5m Mounting height: - Recommended: 2.5 m - Permitted: 2.2 m to 3. m 1m 2m 3m 4m 5m Retrofitting of the mirror optics Easy retrofitting of the mirror optics on site: 1. Remove screw 2. Fold up mirror 3. Remove mirror Installation: Insert the new mirror in reverse order. Insert the screw and tighten slightly. Close housing.

Mounting 45 1. Mounting directly on the wall a) Mounting possibilities: - Vertical at a downward angle - 3 Vertical at a 3 downward angle - 45 Horizontal at a 45 angle to the left or right - Corner mounting +/- b) c) 45 Please note: When installed in accordance with VdS systems class B and C, the backtamper must be used. Backtampre is not possible when installing as per Fig. a) and c) ( detectors) or Fig. c) (DUAL detectors) The only exceptions are class B detectors without backtamper. 2. Mounting on Adjustable joint (Accessories, Item no. 3339.17) Should the mounting possibilities in accordance with Fig. above not suffice, the detector can be mounted on the "Adjustable joint". Swivel range: ± horizontal, +4 to -8 vertical. Detector on Adjustable joint as per EN grade 2. ±2 45 Mounting possibilities: - Mounting directly on the wall - 45 Horizontal at a 45 angle to the left or right - Corner mounting +4-8 Adjustable joint 45 The adjustable joint is not provided with a backtamper! For the installation in VdS systems of class B and C, a solid basis with the defined inclination is required on site to ensure proper functioning of the backtamper. The only exceptions are class B detectors without backtamper. 3. Mounting on Ball-and-socket set (Accessories, Item no. 33588.17) The Ball-and-socket set provides the most versatile adjustment possibilities. Swivel range: ±45 horizontal, ± vertical. Mounting on Ball-and-socket set not as per VdS and EN.

Technical Data Operating voltage U_b Operating voltge range Current consumption at U_b=12 V DC: detector: 1.6 ma ( and ), 3. ma (BUS- DUAL detector: 6.6 ma ( and ), 9. ma (BUS- LED 4 ma Detection range (programmable): Area optics 8 / 11 / 13 / 15 m Long-range optics (Item no. 33435) 29 / 35 / 42 / 5 m Curtain optics (Item no. 33434) 17 / 21 / 25 / 3 m Detection sensitivity (programmable): sensor Anti-Mask function (only AM detectors) Frequency microwave (only DUAL detectors) normal / high temperature compensated up to 3 cm 9.35 GHz (X band) Contacts: (only detectors) Alarm- and fault contact 15 V DC /.1 A, Internal resistance 25 Tamper contact 15 V DC /.1 A, Internal resistance 1 Protection category as per EN 6529 Environmental class as per VdS Operating temperature range Storage temperature range Dimensions W x H x D Colour 12 V DC 8. V to 15 V DC IP 3 II -1 C to +55 C -25 C to +7 C detector: 64 x 13 x 48 mm DUAL detector: 64 x 158 x 48 mm traffic white (similar to RAL 916) VdS approval no. Item no. 33432.21 Item no. 33332.21 Item no. 3343.1 Item no. 3333.1 AM /BUS-1 /BUS-1 AM G1836, IDS Class C, with area optics G1837, IDS Class C, retrofitted with curtain optics G1838, IDS Class C, retrofitted with long-range optics G1859, IDS Class B, with area optics G1851, IDS Class B, retrofitted with curtain optics G18511, IDS Class B, retrofitted with long-range optics G1787, IDS Class C, with area optics G1788, IDS Class C, retrofitted with curtain optics G1791, IDS Class C, retrofitted with long-range optics G1759, IDS Class B, with area optics G1751, IDS Class B, retrofitted with curtain optics G17513, IDS Class B, retrofitted with long-range optics Item no. 33442.21 Item no. 33443.21 Item no. 3344.1 Item no. 33441.1 DUAL AM /BUS-1 DUAL /BUS-1 DUAL AM DUAL G1839, EMT Class C G18512, EMT Class B G1878, EMT Class C G18518, EMT Class B

Ordering information Item no. Designation 33432.21 AM /BUS-1 33332.21 /BUS-1 3343.1 AM 3333.1 33442.21 DUAL AM /BUS-1 AM DUAL AM DUAL 33443.21 DUAL /BUS-1 3344.1 DUAL AM 33441.1 DUAL Accessories Item no. Designation Long range mirror Curtain mirror Mirrors sets: 33434 Replacement Mirrors Curtain mirror, (PU = 3 piece) 33435 Replacement Mirrors Long range mirror, (PU = 3 piece) Ball-and-socket set Adjustable joint Seal Mounting Accessories: 3339.17 Adjustable joint for motion detectors suitable for wall and corner mounting horizontal ±, vertical +4 to -8 as per EN grade 2 33588.17 Ball-and-socket set for wall and corner mounting horizontal ±45, vertical ± not as per VdS and EN 33391.17 Seal (PU = 2 piece) 33436 spare parts wall-tamper Honeywell Security Group Novar GmbH Johannes-Mauthe-Str. 14 72458 Albstadt Telefon +49() 74 31/81- Telefax +49() 74 31/81-12 2 www.honeywell.com/security/de info.security.de@honeywell.com P1543-22-G-3 4.215 Subject to change without notice 215 Honeywell International Inc.