OPTA-PERIPH 8 Av. de Bretteville Neuilly - France 33(0) Fax : 33(0) Document: IM By PB Date: 18/11/2005

Similar documents
Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Roof top SPACE RPC 450Z R407C M011

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Main switch current K: with main switch (optional)

MACH N-407 Heat Pump Air-Cooled Chiller

Call us today! (800)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Roof top SPACE RPC 315Z R407C MA00

Exp, pressurized systems

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Call us today! (800)

Call us today! (800)

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Concealed Ducted Split Series R-407C MBH

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

General Description. Operation

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

air systems Roomtop RTC-RTH 15 to 30 - L

MODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS

30GN FLOTRONIC II AIR-COOLED CHILLERS

AIR COOLED PACKAGED CHILLER

Comfort. Description. Applications

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Commercial High-Efficiency Condensing Units

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30GT FLOTRONIC AIR-COOLED CHILLERS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MAC N-407 Air-Cooled Chiller

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Trouble Shooting Guide PAA, 1-phase (D3731)

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

.2 Section Waste Management and Disposal.

Trouble Shooting Guide RAA, 1-phase (D3627)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Trouble Shooting Guide FAA, 3-phase (D3631)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Indoor Air Handlers with Compressors MVS and MVW

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

CF1 ProVector Explosion-Proof Heaters

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

CX1 ProVector Explosion-Proof Heaters

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CENTRAL SPLIT UNIT UNIC

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Vortex Enclosure Coolers A/C ATEX

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

PACKAGE AIR CONDITIONER

E U R O V E N T CERTIFIED PERFORMANCE

CALOREX TECHNICAL GUIDE PRO-PAC H HY. Air/water heat pumps

SET-2000 Hi Level/Oil

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Commercial High-Efficiency Condensing Units

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

OilSET-1000 (12 VDC)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Capacity: 1.5 to 6.0 Ton

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Capacity: 1.5 to 6.0 Ton

Snifter ATEX22 VERSION. User Manual. Distributor

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

FE1 Explosion-Proof Electric Air Heaters

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).


Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CommStat 4 Controller

LZT High efficiency air to water heat pumps with E.V.I. compressors

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

SET Installation and Operating Instructions. Level switch for one sensor

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CENTRIFUGAL AIR CONDENSERS

KELVIN Clim F497. Kelvin air conditioning

Transcription:

OPTA-PERIPH 8 Av. de Bretteville 92 200 Neuilly - France 33(0)6 85 43 82 78 - Fax : 33(0)6 07 18 28 07 User: AIR CONDITIONER ATEX CE II 3G Supplier : OPTA-PERIF Ref : Q/N 0510278 Rev.: 0 Document: IM 050312 Issued By PB Date: 18/11/2005 : AIR CONDITIONER ATEX CE II 3G Model SAR VAC 15000 TECHNICAL BROCHURE WATER CHILLER VENTILATION UNIT HVAC ATEX Zones 1 and 2

for analyser shelters 1-PRESENTATION: Refinery analyser shelters HVAC are typically zone 2 classified for the chiller/heater with ventilation system classification for zone 1 as in case of LEL detection ventilation system is kept running. Main part of ventilation systems are unable to control a 2.5 mmwg minimum pressure indoor and a water chiller is often required as addition for sample cooling or analyser utility. The SAR VAC 15000 is a split system involving the ventilation unit / water-air exchanger model AEIB HCAS 740-4-0.37 LG and the recirculating water chiller model SAR 15000 AS 300F 3G. This system has been designed to comply with the following specifications: -Effective air conditioner cooling/heating capacity: 15 Kw (51 000 Btu/hr). -Chilled water supply: 10 C - 3 bars -Ventilation: 1 000 m3/h - static pressure: 15 mm WG -A motor speed variator is proposed as option for adjustement of the ventilation flowrate to the required site experimental value. Classification: Recirculating water chiller: CE EEx II 3G IIC T4 (ATEX Zone 2) Ventilation unit:ce EEx II 2G IIC T4 (ATEX Zone 1) or CE EEx II 3G IIC T4 (ATEX Zone 2) Ventilation Unit Water Chiller Control Unit Enclosure Air Purge Unit LCS

2- MATERIAL DESCRIPIVE: Recirculating water chiller model SAR AS 300F 3G has been designed for Cooling output of 15 000 W This system certified CE Ex II 3G IIC T4 (ATEX Zone 2) integrates ATEX II 2 G EExd IIB T4 fan condenser; ATEX II 2G EExp IIB T4 control unit air purging; ATEX II 2 G EExd IIB high pressure alarm switch; pneumatic water pump ATEX 94/9/EC and hermetically sealed compressor. Ventilation unit / water-air exchanger model AEIB HCAS 740-4-0.37 LG: consists of motor direct drive blower and water/air heat exchanger. The cooling is operated by the 1 000 m3/h ventilation flow rate. Blower is realised in galvanized steel; exchanger in copper with aluminium fins anticorrosion coated and enclosure in galvanized steel; condensates collector is in stainless steel This system certified CE Ex II 2G IIC T4 (ATEX Zone 1) integrates ATEX II 2 G EExd IIB T4 motor blower and high temperature alarm switch 3-TECHNICAL SPECIFICATIONS: 3-1 Recirculating water chiller Model:: SAR 15000 AS 300F 3G Cooling output: 15 300 W / 13.16 Kcal( @ 10 C water set point and 32 C ambient) Electrical consumption power : 5.3 kw Max. current : 14.1 / 66.3 A Electrical supply: : 380 V -3 Ph- 50 Hz Temperature controller : Electronic with digital read-out Compressor type : hermetically sealed Coolant : R407 Air condenser cooler : on top Water pump : pneumatic Water flow : up to 3.80 m3/h Maximum water output pressure : 2.6 barg Water tank : 60 l. Enclosure size : 615 (W) x 1265 (H) x 1160 (D) mm Materials: condenser / evaporator: copper anti-corrosion coated; enclosure: carbon steel painted grey RAL 7032; water tank: stainless steel

3-2 : Ventilation unit / water-air exchanger model AEIB HCAS 740-4-0.37 LG Water air exchanger: BSC 25 EC Exchange area: 15.5 m2 Cooling power: 15 000 W at 8 C water inlet and 13 C air outlet Water flow: 2.79 m3/h Temperature air inlet / relative humidity: 40 C / 50% RH Temperature air outlet / relative humidity: 18.4 C / 96,9% RH Blower flow: 1 000 m3/h at 150 Pa Pressure drop on water: 41 Pa Pressure drop on air: 3,6 mm CE (35.3 Pa) Air velocity: 1,37 m/s Water exchanger capacity: 7,25 l Condensates collector: stainless steel Water condensate rate: 0,000577 kg/s Tube Tube: copper anti-corrosion coated: 12,7 x 0,405 Fins BG 1232Q1 Aluminium Blower: HCAS 740 Turbine: galvanized steel Motor 0,37 kw- 4 poles-3 Ph 380V-50 Hz Enclosure : galvanized steel 4-FUNCTIONALITY: Material features the following main functions: 4-1 Recirculating water chiller 4-1-1: Compressor monoblock ref TAG 4528Y: Power: 400-440 V /50-60 Hz Expension device: Capillary/Expension valve Cooling: forced Windings resistances at 20 C: phase N 1,2,3 : 4.3 Ohms Current: rated current RLA : 4.3 /5.1 Max current: 14 A Start current LRA 66 A Compressor is delivered with oil sight glass and crankcase heater

4-1-2: Control unit enclosure: The control unit enclosure with air purge unit LCS box content the following components: main switch fault relay contactor transformer fan condenser+compressor breaker switch ventilation unit fan breaker switch ventilation unit fan speed controller bipolar fuse support unipolar fuse support tripolar fuse support terminal board temperature set point condensat pressostat level switch air bubbler pump flow-rate set valve Control Unit enclosure - Air inlet 1/2" NPTF General air valve General ON/OFF switch Purge flow valve Timer pallet Detector sensitivity (factory set)

Air purge unit LCS 1- General air valve: To be turned ON before of start-up 2-General ON/OFF (pneumatic switch): on air purge unit front door: For the general system start-up this switch is pushed ON for supplying the instrument air to the purging unit. At the end of the purging sequence (refer to annex) the 24 VAC transformer for control powering is energized and this control power supplies the relay of the breaker in the power supply control box, switching ON the compressor, chiller and ventilation unit blowers. As the ventilation unit features a thermoswitch, this contact NC is connected in serial with the power breaker relay for general switch -off in case of over-heating in ventilation enclosure. 3- Electrical control block unit: Referring to the upper part of control unit enclosure and drawing Power Supply pages 1 and 2 this unit involves the switching and protection of the compressor, chiller and ventilation unit blowers. 4- Ventilation.air blower motor speed variator: optional Purpose of this unit is to trim the ventilation air blower motor speed in order to control the ventilated air flow at the value required by application. 5- Pneumatic pump flowrate set valve: The air pressure has been adjusted at 4 bar-g corresponding to a flowrate of 1800 L/H of water. 4-1-2: Power supply junction box: This explosion proof box certified ATEX IIGD EEx d IIC T5/6 involves the main power supply terminal 380 V 50 Hz - 3Ph- 5.3 KW for 3 conductors 2.5 mm2 + ground. 4-1-3: Air purge unit monitor LCS: LCS System protects, by applying an internal over pressure inside of the Control Unit enclosure in which are installed the electrical components. LCS System incorporates a pneumatic logic assembly unit generating the different required functions of purging, leakage flow and pressurisation and the final function to switch ON the electrical power to the enclosure when these standard procedure has been correctly and fully operated.

For this small volume enclosure purging flow is maintained to low value (typically 4200 SL/H). 4-1-4: High pressure switch on coolant: This component, the model Georgin FP62RX is certified ATEX II 2G EExd IIC T6. 4-1-5: Condenser blower: This component, model AEIB EVXPIIB3554P is certified ATEX II 2G EExd IIC T6. 4-1-6: Water pneumatic pump: The pump model WILDEN PIPPPPPWF is air supplied at 4 bar-g pressure for processing the brine flow at the rate of 1,12 m3/h required by the ventilation unit exchanger, higher flow can be adjusted if required by user for sample cooling or analysers utilities. 4-2:Ventilation unit / water-air exchanger Ventilation unit / water-air exchanger model AEIB HCAS 740-4-0.37 LG: consists of motor direct drive blower and water/air heat exchanger. The cooling is operated by the 1 000 m3/h ventilation flow rate. The ventilation motor is powered and protected by the electrical power block unit in the control unit enclosure. A thermoswitch has been provided inside of enclosure to check that ambient temperature of air never exceeds 40 C, in case of detection the general power relay is switched-off as described in previous para. Operator has to clean all deposits of dust if the inside is too dirty On tank condensates, one high water level detector has be provided, this is a pneumatic bubble flow device located in the control unit enclosure and the low pressure switch associated is connected in serial with the power breaker relay for general switch -off