Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Similar documents
Range brochure. Beam detection. others look up to.

talentum Flame detection across the spectrum Range Brochure

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

FIRERAY 5000 range USER GUIDE

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Reflective Optical Beam Smoke Detector User Guide

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Line Smoke Detector LRMX

Beam Detectors. The 6500 Series

This training course discusses the correct use of Infrared (IR) Optical Beam Smoke Detectors for the protection of lives, equipment and property.

End To End Optical Beam Smoke Detector. Additional Information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

Open-area Smoke Imaging Detector. Engineering Specification

this is by far the best beam money can buy

Motorised Infrared Optical Beam Smoke Detector. User Guide

Fireray 2000 Linear Smoke Detector

Motorised Infrared Optical Beam Smoke Detector. User Guide

Talentum - Why use our Flame Detectors?

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Installation and Operation Manual

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Apollo Intelligent Auto Aligning Beam Detector. User Guide

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006)

Sensors and Detectors

Reliably Advanced Extinguishing Control

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Open-area Smoke Imaging Detection (OSID)

Aspirating smoke detection

Open-area Smoke Imaging Detection (OSID)

Dräger Polytron 5720 IR Toxic Gas Detection

Reliably Advanced Extinguishing Control

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron 5720 IR Detection of carbon dioxide

Optical Beam Smoke Detector RK90R - RK90RS

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Consultant Specification AGILE Wireless Fire Detection System

Fact File 66. Guide to Beam Smoke Detectors

D-TECT Dual Tech. GJD360 Triple Technology External Detector

D7024 Fire Alarm Control Panel

Sieger fixed gas detection. Fixed protection from hazardous gas

Dräger Polytron 8700 IR Detection of flammable gases and vapors

LEARNING SPECIAL HAZARD DETECTION TYPES

Movement Detector GJD 300

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Table of Contents. 1. Mounting Tips... 2

Analogue Detectors. Series 200 plus

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

FAAST. Fire Alarm Aspirating Sensing Technology

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8720 IR Detection of carbon dioxide

D-Tect 2 GJD300 Quad PIR Movement Detector

Cerberus FIT conventional system

FIRElux Emergency Lighting

2G & 3G GSM Wireless Beam Alarm

Dräger Flame 5000 Flame Detection

Dräger REGARD -1 Control System

Guidance on Video Smoke Detection Technology (VSD)

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Intrusion Outdoor Protection Perimeter

Touchpoint Pro Flexible Gas Control System

RS Pro Infrared Temperature Sensor

FAAST. Fire Alarm Aspirating Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Dräger Polytron 8310 IR Detection of flammable gases and vapour

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

CCTV, HOW DOES IT WORK?

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Conventional & Twin-wire Fire System

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Reflective Beam Smoke Detector

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

SIMRAD GD10 IR GAS DETECTOR

Dräger Flame 3000 Visual Flame Detector Instructions for Use

Evolution Analogue Addressable Fire System

LPCMPIRM65 & LPCMPIRDSI65

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Flexible Air-sampling Smoke Detection

incontrol Systems Inc. Flame and Gas Detection

SUPREMATouch. Modular Fire & Gas Detection System

Twin Photobeam Detectors Manual

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

intelligent fire alarm ID60series panels

ID50series. intelligent fire alarm panels

Transcription:

Range Brochure

Why use a? Beam smoke detectors are the wide area smoke detection technology of choice, offering both excellent detection and value for money. With a high area of coverage per unit (as high as 1800 m 2 for some units), beam smoke detectors offer more simplified wiring, installation and maintenance than other detection types. As a result, beam smoke detectors are the best fire technology for wide area coverage. How does a beam smoke detector work? A beam smoke detector works on the principle of obscuration. The beam detector sends out an invisible infra-red (IR) beam of light that the receiver measures. If smoke is present in the air then this obscures, or blocks, the light received by the receiver, lowering the amount of light. When enough smoke is in the air, the IR light level will drop below a set level, which then triggers an alarm signal. Why choose Fireray? Cost, accuracy and reliability are considerations that are crucial to making the right product choice. Our commitment to these factors drives customer decisions to choose Fireray. Customers consistently find that Fireray is more cost effective than other products on the market. You can be certain of our accuracy and reliability. All of our products are manufactured in the UK. As a result, we have a better depth of knowledge about the products we are selling and the insight to answer questions knowledgeably to help in selecting the appropriate Fireray to meet your needs. Customers across numerous industries rely on Fireray for their accuracy and ease of use and the end user trusts the Fireray name when choosing a beam smoke detector. Choose Fireray to take advantage of an accurate and reliable product, at the right price, backed by 40 years of experience. Installations Fireray products have been installed in many different buildings and establishments. Examples of the different applications that our products have been installed include: Derby Velodrome Doha Airport Neuschwanstein Castle Benefits Product Range Our Fireray range is the perfect solution for areas that you want to protect that are open and have high ceilings such as auditoriums, warehouses, airports and historical buildings. With its easy first fix system, and knockout features, it allows for both ease of wiring and quick alignment. Reflective: Most widely used and requires less wiring, which offers reduced installation cost and time. Automatic alignment Building movement and contamination compensation Light Cancellation Technology (LCT) Fast automatic beam alignment from ground level Compensates for building movement by realigning or lens contamination by readjusting the beam to achieve the correct received signal during its installed lifetime Minimises false alarms in applications where reflective surfaces or direct sunlight are present Fireray 5000: Motorised Reflective Auto-Aligning Fireray 50R/100R: Reflective Fireray 3000: End-to-End Fireray 3000 Exd: End-to-End Explosive Proof End-to-End: Should typically be considered where there are reflective surfaces close to the beam s path, or where the beam path would be restricted due to fixed obstructions. Condensation Heater 2 Wire cable from system controller to detector Allows for 2 detectors per system controller Working path for detector alignment Raises the ambient temperature of a detector lens, making it hard for condensation to form Considerable savings in installation and cost Lowers installation costs Ensures precise alignment of the detector and the reflector in the optical path www.ffeuk.com

Fireray 5000 Motorised Reflective Auto-Aligning Fireray 3000 End-to-End The Fireray 5000 is one of the most advanced fire detection products in the world, combining a transmitter/receiver in the same detector head with an automatic alignment motor. This combination allows for quick, simple installation and requires wiring and power at only one side (the opposite side is covered by a reflector). The Fireray 5000 beam automatically compensates for environmental effects on the beam signal, keeping the unit in the best possible working order. This is achieved through the combination of software (automatic gain control) and motorised realignment of the beam. Other installation aids include the detector and controller First- Fix systems, as well as a visible laser to aid the user in alignment which allows the reflective prism to be positioned quickly and with confidence. This device can be installed by a single engineer, thus offering further saving on installation and commissioning costs. The system is fully customisable with both the alarm thresholds (sensitivity) and delay to Alarm/Fault being controlled from the ground level System Controller. The low level controller incorporates a LCD display, which offers a full icon-based, easy-to-use interface unit. Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Programmable Sensitivity and Fire Thresholds 20mm Cable Gland Knockouts on System Controller 2-wire interface from System Controller to Detector The Fireray 3000 is our solution to the most technical and challenging of installation environments. The system uses a paired set of transmitter/receiver heads to cover the protected area. The unit emits a narrow beam of infra-red (IR) light in order to monitor for smoke and is controlled using a compact low level controller. Both detector heads (transmitter and receiver) have integral thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. This model has been designed so that it can be installed by a single engineer. It also incorporates a visible laser as an alignment aid, with alignment LEDs offering a visual feedback. The system is fully customisable, with both the alarm thresholds (sensitivity) and delay to Alarm/Fault being controlled from the low level controller. This controller incorporates a LCD display, which offers a full icon-based, easy-to-use interface unit. This controller enables ease of commissioning, testing and maintenance of the beam detection system. Range 5 to 120 metres, configurable per set of Detectors Light Cancellation Technology (LCT) Integral laser alignment in receiver 2-wire interface between controller and receiver Single and twin detector options Separate fire and fault relays per detector Low level controller with LCD display Programmable sensitivity and fire threshold Contamination Compensation First-Fix design for transmitter, receiver and controller Multiple cable gland knockouts for ease of wiring Optional transmitter powering from controller F Fireray 5000 Accessories Fireray 3000 Accessories

Fireray 50R/100R Fireray 3000 Exd Reflective End-To-End Explosive Proof The Fireray 50R/100R beam smoke detector series provides economical and effective protection of large open spaces. It comprises of a single unit incorporating an infra-red (IR) transmitter and receiver, with a reflective prism. The system can be connected to a zone of a conventional fire alarm control panel, or interfaced to an analogue addressable system via an interface module. The Fireray 50R/100R offers three selectable Alarm Thresholds settings of 25%, 35% and 50%, which can be chosen to suit the environment. The Fireray 50R/100R beam smoke detector can monitor longterm degradation of beam signal strength caused by the build-up of dirt on its optical surfaces; this operates by regularly comparing the received infrared signal against a reference voltage. To aid installations, a full range of accessories are available, for further details visit www.ffeuk.com. Single compact housing Two models available, a 50m and 100m version 12-24 Vdc Operation Low current consumption Robust construction Approved to EN54:12 and UL268 The Fireray 3000 Exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. Fireray 3000 Exd comprises an infra-red transmitter and a receiver, both of which are ATEX-certified for use in Group 2 hazardous areas. There is a separate, safe area, wall-mounted remote/low level control unit to allow adjustment and testing from a convenient non-hazardous location. The product is designed for large enclosures within oil rigs, refineries, ordnance stores and similar premises. It provides an early warning of smouldering or strongly smoke-generative fires, which may not be picked up by flame detectors installed in many hazardous areas. Separate transmitter and receiver unit certified to Exd Allows for 2 Detectors per System Controller Separate Fire and Fault Relays per Detector Range 5 to 100 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Remote/low Level Controller with LCD display (Safe Area) Programmable Sensitivity and Fire/Fault delay Contamination Compensation for dust and building movement Multiple cable gland knockouts for ease of wiring Transmitter can be powered from Controller Complies with ATEX and EN54:12 Light Cancellation Technology Fireray 50R/100R Accessories Fireray 3000 Exd Accessories

US Sales and Distribution FFE Limited 1455 Jamike Ave Ste 200 Erlanger KY 41018-3147 USA t +1 859 957 1570 f +1 972 534 1526 e america@ffeuk.com Head Office HQ FFE Limited 9 Hunting Gate Hitchin, Hertfordshire SG4 0TJ England t +44 (0) 1462 444 740 f +44 (0) 1462 444 789 e sales@ffeuk.com Worldwide Offices Worldwide Technical Support t +44 (0) 1462 444 740 f +44 (0) 1462 444 789 Middle East Sales Office Dubai UAE India Sales Office Bangalore India China Sales Office Shanghai China e technical@ffeuk.com e middleeast@ffeuk.com e india@ffeuk.com e china@ffeuk.com w www.ffechina.com Formerly known as Fire Fighting Enterprises Ltd Document Part No: 24-0096-02 0651_1016