HART XL High Sensitivity Smoke Detection

Similar documents
HART XL High Sensitivity Smoke Detection

Why Hart XL Aspirating Smoke Detection?

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FAAST. Fire Alarm Aspirating Sensing Technology

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

Aspir A ation spir P R O D U C T S

Aspirating smoke detection

FAAST. Fire Alarm Aspirating Sensing Technology

Aspiration Detection.

Flexible Air-sampling Smoke Detection

Reliably Advanced Extinguishing Control

Aspirated Smoke Detectors

Reliably Advanced Extinguishing Control

ID50series. intelligent fire alarm panels

Open-area Smoke Imaging Detection (OSID)

Buys Time. Aspirating Smoke Detection

LaserFOCUS VLF-250 Engineering Specification

intelligent fire alarm ID60series panels

Buys Time. Aspirating Smoke Detection

The World's No. 1 Brand of Air-sampling Smoke Detector

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Earliest Warning Aspirating Fire Detector

Advanced FireAlarm Panel 1-4Loop

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Intelligent 2 & 4 Loop Fire Alarm Control Panels

FAAST PRODUCT RANGE Aspirating Smoke Detection

FAAST. Fire Alarm Aspiration Sensing Technology

The World s No. 1 Brand of Aspirating Smoke Detection

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

The World's No. 1 Brand of Aspirating Smoke Detector

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Open-area Smoke Imaging Detection (OSID)

The new detector from Rafiki

VESDA VLP. Engineering Specification

Open-area Smoke Imaging Detection (OSID)

The EN54 Part 2 and 4 Fire System

Honeywell Air Sampling Devices Data Sheet

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

The World's No. 1 Brand of Aspirating Smoke Detector

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

ID2000. intelligent fire alarm panel

Solution F2. Fire Alarm Control Panels one step ahead.

Range brochure. Beam detection. others look up to.

Aspirating Smoke Detection

High-precision aspirating smoke detectors for every requirement.

and Aspirating Smoke Detection

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

FDA241, FDA221 Siemens ASD

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

The EN54 Part 2, 4 and 13 Fire System

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

General Routing Interface

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

ID3000 intelligent. fire alarm panel

FDA241, FDA221 Siemens ASD

The EN54 Part 2 & 4 Fire System

Consultant Specification AGILE Wireless Fire Detection System

Aspiration Systems for Smoke Detection

Sita200plus. 200detectors. Single loop analogue addressable System

Parker icount Oil Sampler (IOS)

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Different types of Fire Alarm System

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

System 800 Addressable Fire Detection & Alarm System

Evolution Analogue Addressable Fire System

ALARMLINE ANALOGUE Linear Heat Detection System

ID3000 intelligent. fire alarm panel

Air Sampling Smoke Detection

Aspirating Smoke Detection for Large Area Coverage Applications

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

The Next Generation of VESDA Aspirating Smoke Detection Technology

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

MINERVA MZX125 Digital Addressable Fire Detection System

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Conventional & Twin-wire Fire System

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Honeywell Air Sampling Devices Data Sheet

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Intelligent addressable fire alarm control panel

icount Oil Sampler (IOS)

For Complete Fire and Gas Solutions

Product Data Sheet. Remote Terminals. Features:

Optical Beam Smoke Detector RK90R - RK90RS

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Engineer Paging. Staff Paging. Deaf Alert.

Monitoring Solutions

HRX Technical Manual. Version 1.2

Laser Technology Smoke Detector

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Open-area Smoke Imaging Detection (OSID)

Transcription:

High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in terms of performance. It is designed to give very early indication of an incipient fire condition. This swift notification before the transition into the flaming and heat stages provides the time necessary to take corrective action and avoid the danger, damage and disruption of fire. Features Laser based particle counting the superior technology Elegant, compact, lightweight design No particle filters required No recalibration during lifetime of detector Complete flexibility four basic sub units provide installation options On site sensitivity selection 0.005%/m to 1%/m LaserNet networking options Modular design for fast and easy servicing Configurable for integral or remote display options Attachable power supply and battery back up unit Individual pre-alarm and alarm levels Protecting assets worldwide Developed in 1988, Hart was the world s first laser-based detector. Using patented particle counting technology, over 30,000 Hart detectors are in use worldwide, protecting valuable assets for institutions and companies such as Royal Palaces, London Underground, BP and HSBC. Protecting your investment There are major benefits from a very early indication of incipient fire, which can be dealt with by local corrective measures, i.e. removal of power from equipment or by portable extinguishers. However Hart XL can also provide a first stage signal to initiate suppression system release at a higher alarm level. Hart XL is not dependent upon a particular brand of control panel, which reduces new equipment costs and business disruption.

2 Stages of fire Most fires start with some form of overheating. In this incipient stage, invisible particles are released as the combustion process begins. The particles released at the incipient stage of a fire may not be detected by conventional smoke or heat detectors. In fact, smouldering can continue for minutes, hours or even days before activating conventional detectors. The incipient stage of smouldering fires provides the widest window of opportunity to detect and control the spread of fire. As smoke is formed, it will begin to fog the atmosphere with particles. Conventional point detectors are designed to detect smoke at approximately 3% to 5% obscuration per metre at the detector. This will normally allow sufficient time for occupants to evacuate the area or building, although possibly not enough time to prevent damage to equipment. At this level there may also be an increased risk to anyone attempting to extinguish the fire. Aspirating detection As opposed to point type smoke detectors mounted at regular intervals throughout the area of protection, an aspirating detector is installed one per area of protection (depending on size of area). A pipe network is spread across the area of protection and transports air from the protected area back to the detection unit. Hart XL can be programmed to be up to 1000 times more sensitive than conventional point detectors. Alarm levels can be set as low as 0.005% obscuration per metre for clean areas and up to 1% obscuration per metre for less controlled environments. This increased sensitivity allows Hart XL to detect and report an incident at the earliest possible stage, providing the time needed to help minimise or prevent fire damage, avoid system down time and provide business continuity. INCIPIENT STAGES (no visible signs) POINT DETECTORS FLAME DETECTORS INTENSE HEAT obscuration PRE-ALARM 1 PRE-ALARM 2 ALARM 1 time ALARM 2

3 SAMPLING PIPE SAMPLING POINTS The unit is mounted either inside or outside the area and draws air from the protected area using a fan contained in the detection unit. The pipe network contains sampling holes at predetermined locations along the pipe network through which the air is drawn. Individual particle counting Hart XL is a laser-based particle counter designed to detect very small levels of particulate. The intensity of the laser light source is carefully monitored, maintained and controlled. The laser is focused into a high intensity beam of light in the centre of the sampling chamber. This beam forms the sensing area for the smoke particles. Light scattered by each smoke particle is detected by very sensitive receive optics. The output signal is processed and presented on the LED or LCD display module. Hart XL communicates this data back to the fire alarm control panel or building management system. SOLID STATE LASER AIR FLOW SENSORS COLLIMATING LENS CONTROL PCB RECEIVE OPTICS OPTICAL SENSOR DETECTOR TEST LED Detection takes place in the centre of the sample chamber which ensures a high level of immunity to particulate build up on the chamber walls. Only particulate within the centre of the focussed laser light is measured by the receive optics. As the smoke particulate passes into the sampling chamber, the sensor electronically counts each particle. Particle counting HSSD devices are thus much more sensitive to the prevailing concentration of small particulate.

4 10 micron 0.1 micron REJECT REJECT Particle discrimination Hart XL can intelligently discriminate between smoke particles and other foreign matter by individual setting of the upper and lower detection threshold. Dust, for example, would register as a larger particulate than smoke, break the upper threshold level, and therefore be rejected. This ability allows Hart XL to be set up for various applications without compromising the effectiveness of the detector. Where to use Hart XL Hart XL provides total protection in mission critical facilities: When downtime must be minimised with high cost equipment: Clean rooms Computer rooms Telecommunications Broadcast facilities Server farms, Telco hotels Where smoke is difficult to detect in areas with high ceilings or high air flow: Atria Warehouses Cold storage Indoor stadiums In extreme environments that pose a problem to conventional smoke detection: Power stations Mines Offshore Where appearances are important and preservation of priceless objects is a priority: Modern offices Heritage buildings Cathedrals Museums Libraries When extra time is necessary to effect safe and orderly evacuation: Airports Underground railway systems Hospitals Theatres Cinemas

5 There s complete flexibility just four sub units provide all the configuration options: Product range The Hart XL High Sensitivity Smoke Detection (HSSD) system from Kidde Fire Protection represents a major, intensive two-year development programme. The result is a product optimised in terms of performance, capability, reliability and serviceability. Featuring simplicity in both system configuration and operation, Hart XL has a clean, aesthetic design and is compact and lightweight. Configuration options Hart XL Unilaser single station detection unit The Hart XL Unilaser features the display module as an integral part of the detection unit. The Hart XL detection unit can be wall or flush mounted and allows for top or bottom pipe entry and side or rear air exhaust. Hart XL Unilaser with self-contained power supply The self-contained power supply and battery back up can be attached to the detection unit or located remotely. Hart XL detection unit with remote display module The display module can be integrated as part of the detection unit or located remotely. No separate cabinet is required. The detection unit retains a local status LED. Hart XL detection unit with system status LED Hart XL can be configured to provide a simple three-colour LED status indicator green for normal, yellow for fault, flashing red for pre-alarm and continuous red for alarm. Hart XL network system When used with the Intelligent Interface Module (IIM) and LaserNet software, up to 127 Hart XL detection units can be networked and displayed on a PC monitor.

6 Display module The graphical LCD on the display module provides information including system status, real time smoke levels and other operational parameters. The unit is operated by means of simple pushbutton controls. Password protection is used to restrict higher levels of access to authorised users. LaserNet Programming and diagnostics All Hart XL detection units are programmed using a standard PC connection via a service port and the LaserNet software. The software enables the user to monitor, interrogate, configure and download system data. No programmers or interfaces are required. ADDRESSABLE MODULE ADDRESSABLE MODULE FIRST DETECTOR UP TO 127 DETECTORS LAST DETECTOR NETWORK LOOP IIM FIRE ALARM CONTROL PANEL REMOTE PC WITH MODEM LOCAL PC

7 SNIFF System Design Software The easy-to-use pipework design software, SNIFF, has been upgraded to be Windows compatible and includes new features such as isometric system design drawings from different angles, easy operation and clear displays. Maintenance Hart XL has been designed to facilitate servicing and maintenance. The modular design reduces servicing time and minimises downtime. The detection unit comprises only three main parts the termination board, the detector head and the fan module DETECTOR HEAD Each can be installed and removed quickly and easily. Routine maintenance and cleaning of the laser sensor unit is a simple process. TERMINATION BOARD Modular design concept Clip-on modules for quick and easy installation and removal Quick release interconnecting cables Easy access external cable connectors No filter - lower servicing cost FAN MODULE

8 Specification Hart XL Detection Unit Physical Specification Overall dimensions 320mm x 228mm x 108mm Weight 3.4kg Enclosure IP31 Operating temperature 0 to 52 C Hart XL Detection Unit Power Requirements Voltage 18 to 30 vdc (24 vdc nominal) Current Consumption: Quiescent 315 ma Alarm 380 ma Fault 365 ma Hart XL Display Control Unit Physical Specification Overall dimensions 122mm x 145mm x 38mm Weight 0.5kg Enclosure IP31 Operating temperature 0 to 52 C Displays Operator controls Outputs Programmable time delays History buffer Event log Signal averaging Referencing Factory presets Programming Large format graphical LCD 4 cursor controls (up, down, left, right) and Enter key Relay outputs Alarm 1, Alarm 2, Pre-alarm 1, Pre-alarm 2, Fault, Isolate Volt free change over relay outputs rated at 2 amps 30 vdc, providing common and normally open, contacts Power out two sets of auxiliary outputs 0 to 24 vdc rated at 0.5 amps Remote display control unit connection 4 core connection providing 0v, 24v, and RS485 communication Service port RS232 connection to PC Network connection RS485 to LaserNet network (127 Hart XL detection units max) Delay before alarm registration 0 to 60 seconds 40320 entries 28 days 128 event capacity 2, 4 or 8 second averaging Controlled by LaserNet software Sensitivity default to 0.2%/m full scale on bar graph (adjustable with LaserNet) Direct connection to PC (D-type-RJ12) provided by LaserNet software E9832-327A01/02 Kidde Fire Protection UK Sales Office Head Office Thame Park Road, Thame, Oxfordshire OX9 3RT, UK. Tel: +44 (0)1844 265003. Fax: +44 (0)1844 256156. E-mail: info@kfp.co.uk Web: www.kfp.co.uk UK Sales Office Unit 12, Atley Way, North Nelson Industrial Estate, Cramlington, Northumberland NE23 1WA UK Tel: +44 (0)1670 713455. Fax: +44 (0)1670 735553 International Offices Dubai: Tel: +971 4 337 2498. Fax: +971 4 337 5088 Hong Kong: Tel: +852 2195 3688. Fax: +852 2743 7477 Singapore: Tel: +65 424 7979. Fax: +65 424 7978 Australia: Tel: +61 3 9765 3850. Fax: +61 3 9765 3800