High-precision aspirating smoke detectors for every requirement.

Similar documents
High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

ASD 535 Aspirating smoke detector

SecuriRAS ASD 535 Product Catalogue 2015

SecuriRAS ASD 531/532/535

SecuriRAS ASD 535 Product Catalogue 2014

Aspirating Smoke Detection (ASD) Systems Fire Detection

Aspirated Smoke Detectors

Honeywell Air Sampling Devices Data Sheet

HART XL High Sensitivity Smoke Detection

Flexible Air-sampling Smoke Detection

HART XL High Sensitivity Smoke Detection

ADW 535 Line type heat detector

Aspirating smoke detection

Honeywell Air Sampling Devices Data Sheet

Buys Time. Aspirating Smoke Detection

LaserFOCUS VLF-250 Engineering Specification

FAAST PRODUCT RANGE Aspirating Smoke Detection

The World's No. 1 Brand of Air-sampling Smoke Detector

Buys Time. Aspirating Smoke Detection

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

ASD 531 Aspirating Smoke Detector

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

ASD 531 Aspirating Smoke Detector

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

The World's No. 1 Brand of Aspirating Smoke Detector

ASD 535 Aspirating Smoke Detector

ASD 535 Aspirating Smoke Detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

ASD 532 Aspirating Smoke Detector

The World s No. 1 Brand of Aspirating Smoke Detection

The World's No. 1 Brand of Aspirating Smoke Detector

FAAST. Fire Alarm Aspirating Sensing Technology

Aspiration Detection.

FAAST. Fire Alarm Aspiration Sensing Technology

ASD 533 Aspirating Smoke Detector

Intelligent Earliest Warning Aspirating Fire Detector

ASD 535 Aspirating Smoke Detector

VESDA VLP. Engineering Specification

ASD 531 Aspirating Smoke Detector

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

FAAST. Fire Alarm Aspirating Sensing Technology

FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R. Operation Guide

intelligent fire alarm ID60series panels

FDA241, FDA221 Siemens ASD

Data Centers. ASD 535 Application Report

Why Hart XL Aspirating Smoke Detection?

Aspiration Systems for Smoke Detection

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

Air Sampling Smoke Detection System TITANUS MICRO SENS Rev.a

FAS-420-TM Aspirating Smoke Detector FAS-420-TM. Operation Guide

SIHI dry Dry running vacuum pumps

Aspir A ation spir P R O D U C T S

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

All the security you need in one housing

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Desigo Fire Safety intelligent detectors for complete safety

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

SecuriFire SecuriLine extended board B5-DXI2

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

FCS-320-TM Series Conventional Aspirating Smoke Detectors

Evolution Analogue Addressable Fire System

Range brochure. Beam detection. others look up to.

Air Sampling Smoke Detection

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

Aspirating Smoke Detection

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

Engineering Specification Guide VESDA-E VEP

How can you minimize consequential damages in case of a fire?

MHD 535. General functions and specific requirements

Intelligent Detection Devices

FG Wilson Control Systems

OH720, OP720, HI720, HI722

Mounting Instructions for Genius Hx

PERFORMANCE SPECTRUM FIRE DETECTORS

BX-MDI8 Input module for SecuriLine extended

Aspirating Smoke Detection for Large Area Coverage Applications

Trimless In-Ceiling & In-Wall

and Aspirating Smoke Detection

48239 Bar Aid Booklet:Layout 1 05/03/ :52 Page 1 BarAid by

Dräger Flame 2350 (UV&IR) Flame Detection

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Cerberus FIT conventional system

Conventional Detectors

Condition monitoring using FAG products. Technical Product Information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

FAAST Beyond Standard Methods of Detection

SPC-56 SHORT PLANT.

Apollo Accreditation. Need further information? Visit

Dräger Flame 2370 (UV&IR) Flame Detection

Laser Technology Smoke Detector

Line Smoke Detector LRMX

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Transcription:

High-precision aspirating smoke detectors for every requirement. SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors Securiton AG Alarm and Security Systems Alpenstrasse 20, 3052 Zollikofen, Switzerland Tel. +41 31 910 11 22, Fax +41 31 911 25 32 www.securiton.com, info@securiton.com A company of the Swiss Securitas Group 816698 01.18

ASD 535-1 ASD 535-2 Two channels ASD 535-3 Smoke level indicator ASD 535-4 Two channels Smoke level indicator ASD 532 Smoke level indicator ASD 531 The complete model range for any application. The right device for every requirement. A combination of sensitivity and speed. Aspirating smoke detectors from Securiton are among the most precise and most reliable early warning systems against fires. The SecuriRAS ASD detector series impresses by virtue of its unrivalled capabilities. Developed in Switzerland and manufactured in Germany, the detectors are particularly reliable and robust. Thanks to their sophisticated detection technology, they can detect incipient fires immediately. Whether in IT racks, production halls or large deepfreeze areas, Securiton has the perfect fire protection solution for all safety requirements. SecuriRAS ASD detectors are available in three models, with the main difference between them being the maximum possible monitoring area. This means that protection without compromise is now even more cost-effective in small premises. All detectors can be seamlessly integrated into the SecuriFire fire detection system and are extremely durable thanks to their robust design. In terms of smoke concentration, the alarm sensitivity of the HD (high-dynamic) smoke sensor ranges from 0.002%/m to 10%/m. This is equivalent to the sensitivity spectrum of a laser-based detector. In the extra-large LVSC (large-volume smoke chamber), the sensor permanently analyses the airflow with a high-power LED using tried-and-tested scattered light technology. It meticulously detects even the slightest increases in smoke concentration. With its patented lint filter, it suppresses even the finest dust particles that would otherwise falsify the detection process. Thanks to its optimised aerodynamic measuring chamber, the smoke sensor is also immune to dust deposits. This means that there is little chance of false alarms. Up to five alarm levels can be programmed within the sensitivity range of 0.002%/m to 10%/m. You can then rest assured that individual measures can be taken for each monitored zone. With dangers and hazards detected this precisely, any necessary alarm response is focused and extremely swift. SecuriRAS ASD because performance counts: SecuriRAS ASD because sensitivity counts: Split-second, highly sensitive reaction to incipient fires Lightning-fast fire detection and alarm response Simple handling Three different models for scalable, cost-effective operation Monitoring areas ranging from single facilities up to areas measuring 5760 m 2 Developed in Switzerland, made in Germany Robust and with a very long service life Alarm sensitivity from 0.002%/m (measurement resolution < 0.001%/m) Scattered light technology with high-power LED As sensitive as a laser but with a longer service life and a greater temperature range Up to five alarm levels for environment-based detection Maximum protection against false alarms

Extremely durable even in the toughest environments. ASD 535 perfect for large-scale applications. Extremely robust and discreet in operation. The ASD 535 is the flagship model of the SecuriRAS ASD detector range. It can monitor an area of up to 5760 square metres. Available as a single-sensor and two-sensor device, the detector analyses the airflow from one or two sampling pipes independently. The aspirating smoke detector thus reliably spots any deviation in the airflow and detects any breakages or blockages in the sampling pipes. Up to 400 metres of sampling pipe with a maximum of 120 sampling holes can be connected to each smoke sensor. More than 400 Pa of aspirating underpressure generates the necessary power, which means the ASD 535 has one of the most powerful fans on the market. Frosty conditions? The SecuriRAS ASD 535 won t even sneeze. Hot conditions? No sweat the ASD 535 carries on working without complaining. These robust aspirating smoke detectors can be deployed at temperatures ranging between 30 C and + 60 C retaining their full functionality at all times. In deep-freeze applications, the evaluation unit is installed directly in the deep-freeze area and the sampling holes are heated automatically when needed to prevent them from freezing. Using the Config over Line function, you can carry out configuration and maintenance comfortably on the fire alarm control panel having to personally access zones with extremely high or low temperatures is now a thing of the past. Further possibilities for accessing the aspirating smoke detector remotely are provided by RS-485 networking. Dusty, steamy or dirty conditions? It makes no difference to the ASD 535. The extensive range of accessories includes various dust filters, water retaining boxes and other tools. The Autolearning function allows for automatic adaptation of the sensitivity according to the ambient conditions, which means the ASD 535 operates with optimum sensitivity at all times while also being protected against false alarms. It is also immune to dust deposits thanks to its optimised aerodynamic measuring chamber. It cleans its sampling pipes and holes itself using the automatic blow-out device. The choice of sampling pipe material is determined by the individual requirements on site. When it comes to the quality of the ASD 535, Securiton is uncompromising: the aspirating smoke detector is designed for a very long service life. Although the ASD 535 is equipped with a high-performance fan, it is whisper-quiet. In fact, it s one of the quietest aspirating smoke detectors on the market. It stands out by virtue of its extremely low noise levels (34 dba), making it compliant with ISO standard 11690-1 for the design of low-noise workplaces containing machinery. ASD 535 perfect for large monitoring areas: ASD 535 immune to disturbances: Applications: high-bay and deep-freeze warehouses, Ex zones, large data centres, historic buildings, large halls etc. Permissible temperature range: 30 C to + 60 C Immune to disturbances such as dust, dirt, moisture and steam Reliable detection in difficult environments Protection against false alarms 34 dba: extremely low noise levels No soundproofing measures required Practically invisible installation Simple to integrate into existing architecture Approvals: VdS, DIBt, UL, FM, ActivFire, CCCF

1 1 3 Highest possible sensitivity for demanding applications. 2 ASD 532 powerful and compact. ASD 531 small and simple. The SecuriRAS ASD 532 is used for reliable monitoring of small and medium-sized areas and premises. It has the same technical specifications as the ASD 535, but with just one sampling pipe and a more compact fan. Anyone familiar with the ASD 535 will find added monitoring using the ASD 532 a breeze. Configuration and maintenance of the detector are made in the same simple way. Aesthetically, the ASD 532 is very subtle and discreet just like all devices in the SecuriRAS ASD range. Once installed in hollow spaces, the sampling pipes are completely invisible, while the flush-mounted sampling holes are often imperceptible. The installation is carried out with the highest possible level of adaptation to the surroundings in question. The sampling pipe can be laid out asymmetrically, which means it blends seamlessly into the structure of the building. This eliminates the need for long sampling pipes and thus reduces costs. The ASD 531 is small, yet extremely powerful. As with the two larger models in the SecuriRAS ASD range, it is also equipped with the tried-and-tested HD detector with LVSC (large-volume smoke chamber). Its outstanding sensitivity ensures high levels of safety, combined with an impressively long service life. The ASD 531 ignores individual disruptive factors effectively thanks to its patented lint filter. The ASD 531 is the perfect choice for anyone wanting to put a smaller system into operation quickly and easily without the need for extra training. Configuration is made directly on the device using BasiConfig in just three simple steps without the need for a PC. Operation of the compact device is just as easy. With the ASD 531, you can monitor your rooms and premises reliably and precisely with a minimum of effort and exceptional cost efficiency. ASD 532 for medium-sized premises: ASD 531 for small premises: Applications: elevator shafts, prison cells, clean rooms, laboratories, IT racks, telecommunications facilities etc. Compact design Permissible temperature range: 20 C to + 60 C Maximum sampling pipe length: 120 m Ethernet or RS-485 networking Approvals: VdS, UL, FM Applications: elevator shafts, electric distribution cabinets, false ceilings, small telecommunications containers, clean rooms, ventilation ducts, IT racks etc. Compact design Permissible temperature range: 10 C to + 55 C Maximum sampling pipe length: 75 m Approvals: VdS, UL, FM

Project planning in simple and logical steps. Efficient and optimised complete control over complexity. For complex installations in which, for example, asymmetrical sampling pipes are required, the ASD PipeFlow calculation software takes care of the layout. It lets you plan your system in simple and logical steps, offering maximum benefits while complying with the relevant norm-compliant response grade. With its practical optimisation function, the ASD PipeFlow software always looks for the ideal balancing of the sampling pipe so that each sampling hole has the same sensitivity. Furthermore, all accessories for the sampling pipe are integrated in the software. The SecuriRAS ASD aspirating smoke detector is configured using the ASD Config software or for even more convenience via the Config over Line function on the SecuriFire fire alarm control panel. The detect ors communicate directly with the control panel via the SecuriLine extended addressable loop including during commissioning and maintenance. This significantly reduces maintenance work trips to the individual devices are no longer necessary as everything can now be carried out efficiently on the fire alarm control panel. For application-specific adaptations, use the practical ASD Config software tool. Its extensive analysis functions and setting options provide you with valuable information for the safe, cost-effective operation of your system. On simple systems, EasyConfig is there to offer optimal support directly on the device (without the need for a PC). Config over Line: simple, centralised configuration and maintenance. Securiton is raising the bar in a big way in terms of convenience and efficiency when it comes to managing its ASD special fire detectors: the new Config over Line function allows the devices to be addressed directly from the fire alarm control panel. With technicians having to contend with large premises and scaffolding and ladders impeding work flows and production processes, the setting, commissioning and maintenance of SecuriRAS ASD aspirating smoke detectors has traditionally been accompanied by a great deal of extra effort. Technicians have had to physically connect their laptop to each detector in turn. This is now history: thanks to remote access via Config over Line, tasks can now be carried out on the fire alarm control panel. Config over Line has massively enhanced both convenience and efficiency. Once the update has been carried out to the SecuriFire Studio application and the device software, the user has access to almost every function of the ASD Config and ADW Config tools for controlling the detectors remotely. Just as conveniently, the update requires no additional wiring. Data exchange between the special fire detectors and fire alarm control panel is achieved by means of the existing SecuriLine extended addressable loop. SecuriRAS ASD making what is complex simple: Config over Line the benefits: ASD PipeFlow software for efficient planning VdS-approved software for optimised solutions Config over Line for central configuration, commissioning and maintenance No physical access to the device required ASD Config software for complete device setup and analysis functions EasyConfig for simple commissioning directly on the device Efficient, comfortable and reliable configuration and maintenance of special fire detectors via SecuriLine Simple maintenance, even in installation locations that are difficult to access No additional costs: software update is all that is needed No additional wiring No more service interruptions or faults Leading global solution from Securiton

1 265 mm 148 mm 195 mm 195 mm 195 195 mm mm 140 mm 2 5 348 mm 348 mm 3 ASD 535 ASD 532 / 531 4 6 7 Tried-and-tested and comprehensive the range of accessories. Overview of SecuriRAS ASD aspirating smoke detectors. The right equipment for any application. All items have VdS approval. Optional modules For long-term data logging (analogue values and expansion of the event memory) Direct connection on the SecuriLine extended addressable loop For RS-485 networking Additional relay outputs (up to 10 items) Various sampling pipes PVC, ABS, copper, stainless steel Flex hose (for laying in concrete and flexible installation) Capillary tubes (discreet sampling points in false ceilings) PVC (standard application) 2 ABS (halogen-free) 3 Stainless steel (for the food industry) 4 Copper (high temperatures and Ex applications) 5 Various dust filters and dirt trap boxes 6 Water retaining box 7 Flame arresters Application-specific sampling holes Suction clips of different diameters Ceiling duct for dropped ceilings Sampling funnel for property monitoring Sampling holes for laying in concrete Aids for use in dirty or damp environments Various dust filters and dirt trap boxes Water retaining box Manual and automatic blow-out devices Cleaning kit Air cooler/heater Accessories for Ex applications Flame arresters Auxiliary housing for personal protection Model ASD 535 ASD 532 ASD 531 Description Universal aspirating smoke detector with one or two sampling pipes for large monitoring areas Universal aspirating smoke detector for medium-sized and small monitoring areas Universal aspirating smoke detector for small monitoring areas and equipment monitoring Channels 1/2 1 1 Smoke sensor High-sensitivity smoke sensor with high-power LED, LVSC smoke chamber and patented lint filter Monitoring area 5760 m 2 1280 m 2 720 m 2 Direct integration in SecuriFire Yes, with XLM-35 module (alarm, pre-signal, faults, day/night sensitivity switching, reset etc.) fire detection system Smoke level indicator Optional (version -3 and -4) Series No Programming (PC tool) ASD Config ASD Config Not available Configuration EasyConfig EasyConfig BasiConfig Calculation of sampling pipes ASD PipeFlow ASD PipeFlow ASD PipeFlow Approvals VdS, DIBt, UL, FM, Activ-Fire, CCCF VdS, UL, FM VdS, UL, FM Applications High-bay and deep-freeze warehouses, large data centres, historic buildings, large/high halls etc. Elevator shafts, prison cells, clean rooms, laboratories, IT racks, telecommunications facilities etc. Single IT racks, small telecommunications containers, elevator shafts, clean rooms, false ceilings etc.