Rapidrop Global Ltd. Product Range. British Manufacturer and Supplier of Fire Sprinkler and Fire Suppression Equipment.

Similar documents
Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Fire Protection Products Technical Data Book Table of Contents, August 2017

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SPRINKLERS TABLE OF CONTENTS

WORLDWIDE VENTILATION SOLUTIONS

Gas Station & C Store SECTION CWM Job No

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Simple On The Outside...

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

A. This section includes design and performance information for fire protection and suppression systems.

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Residential Fire Protection Sprinklers & Systems

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Simple On The Outside...

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION SPRINKLER SYSTEMS

OPEN SPRINKLER SYSTEM

ADDENDUM NO. 3 March 19, 2018

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

VicFlex TM Stainless Steel Sprinkler Fittings

B. Related Sections: The following Sections contain requirements that relate to this Section.

YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS CORPORATE PROFILE

ADDITIONAL PRODUCTS 65

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

North Hanover Township School District North Hanover Township, New Jersey

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

A. This Section includes the following fire-suppression piping inside the building:

SECTION AUTOMATIC SPRINKLER PIPING

WET-PIPE SPRINKLER SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

THE FIRE PROTECTION SPECIALISTS

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

SECTION SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS

Installation and Maintenance Requirements

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION FIRE-SUPPRESSION STANDPIPES

PROFESSIONAL SUPPLIER

AESTHETIC SPRINKLERS.

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

INTRODUCTION SALAM/ATELIER21

Kitemark Certificate No. KM

DIVISION 21 - FIRE SUPPRESSION

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

Flow Control for Fire Protection

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

Flow Control for Fire Protection

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

DIVISION 21 - FIRE SUPPRESSION

SECTION DRY-PIPE FIRE-SUPPRESSION SPRINKLERS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Foam Systems U.S. Quick Reference Guide

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

M A D E I N G R E E C E

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

FIRE PROTECTION SYSTEMS FULL RANGE EXPERTISE. Vertical Turbine Fire Pumps UL and FM approved GRUNDFOS FIRE PROTECTION SYSTEMS

Tyco Fire Valves Pure Performance

Etihad Towers Abu Dhabi

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Metal Woodprint The natural look

Global innovation in fire fighting

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

SECTION PREACTION SPRINKLER SYSTEMS

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Wet Systems Quick Reference Guide. Trusted above all.

Capital Projects Group Fire Protection Sprinkler System Specification

Model F1FR Series Quick Response Standard Spray

Fire Resistant Cables

SECTION FIRE PROTECTION

B. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

SECTION FIRE-SUPPRESSION PIPING

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

Transcription:

Rapidrop Global Ltd British Manufacturer and Supplier of Fire Sprinkler and Fire Suppression Equipment Product Range

About Rapidrop About Rapidrop Global Limited is the leading UK manufacturer of fire sprinkler system products serving the needs of the fire detection and suppression industry. With a comprehensive product range Rapidrop has established a world-class reputation for quality and innovation delivering solutions in fire protection, safety systems and control solutions. The Rapidrop range includes products which have internationally recognised approvals and listings from /UL/VDS and LPCB. Rapidrop s global reach provides a wealth of knowledge and experience in a range of international environments enabling us to provide tailored solutions and meet project requirements on time and on budget. Rapidrop sprinkler equipment has been installed all around the world from London to New York to Paris, from South Africa to Dubai to Rio de Janeiro. Rapidrop have worldwide sales supported by a worldwide sales and distribution network. As part of Rapidrop s commitment to fire safety and protecting lives, Rapidrop invests in research and development conducted at its own state of the art test facilities, one of its kind in the UK. Dedicated to innovation, and reinforcing its position in the market place Rapidrop is focused on bringing new products to the market that makes our customers lives easier, safer and better. 2

Global Reach Etihad Towers Abu Dhabi, UAE Paradise Mall Sofia, Bulgaria Wembley Stadium London, UK Global Reach Rapidrop have supplied sprinklers and fire suppression systems to thousands of projects in hundreds of cities worldwide. We are able to provide fire suppression systems regardless of the size of the project, whether it is a domestic fire protection system or a project as large and iconic as London s Shard. Rapidrop have manufactured sprinkler products for international airports including Heathrow Terminals 2 and 5, London City, Denmark, Sweden and Spain as well as airport hangers and various RAF bases. Rapidrop sprinklers have been installed throughout the world in Hilton, Intercontinental, Sheraton and Novotel Hotels. Hospitals and medical centres worldwide have been fitted with Rapidrop sprinkler systems as well as primary schools, high schools, academies, technical colleges and universities. Offices include the iconic St Mary s Axe, (the Gherkin), Canary Warf and the Shard as well as the Bank of Tokyo, Barclays, HSBC and Dubai Bank amongst hundreds of other offices. Retail outlets range from Burberry to Ikea to Rolls Royce showrooms as well as shopping centres and malls in the UK, Turkey, Bulgaria and Greece to name a few. Rapidrop projects also extend to manufacturing facilities & warehouses worldwide. Entertainment and sporting venues include Wimbledon All England Tennis Club, Wembley Stadium and Arsenals Emirates Stadium, Centre Parcs, the Eden Project, Xscape snow dome, Legoland Denmark, the Reykjavik Opera House and Ferrari World in Abu Dhabi. Big or small, near or far, Rapidrop provides solutions to the fire detection and suppression industry regardless of size or location. Harpa Concert Hall Reykjavik, Iceland Ferrari World Abu Dhabi, UAE Onassis Cultural Centre Athens, Greece 3

COMMERCIAL SPRINKLER HEADS CE, LPCB, UL, & approved Standard Spray Upright, Standard Spray Pendent, Horizontal Sidewall, Conventional, Flush pendent and Concealed Brass, Chrome and paint finish Special RAL colours available on request Standard Response and Quick Response RESIDENTIAL SPRINKLER HEADS UL Listed Concealed type Flush pendent type Side wall White and chrome plated finish Special RAL colours available on request Standard Response and Quick Response SPRINKLERS ACCESSORIES Sprinkler spares cabinets Single escutcheons Two piece escutcheons Sprinkler guards Combined sprinkler guard and baffle plate Baffle plates 4

FLEXIBLE SPRINKLER CONNECTION Unbraided model LPCB approved & UL listed Braided model VDS approved Available in lengths from 780mm upto 3220mm Extensive range of brackets available to suit all ceiling types and sprinkler heads Extensive range of inlets and outlets to suit all applications WET ALARM VALVES CE, LPCB, UL, Available in sizes 80mm upto 200 mm Flanged or grooved connections Pre trimmed to or LPCB specification Alarm gongs Optional retard chamber BUTTERFLY VALVES CE, UL,, APSAD Grooved and Wafer type Working pressure 20 Bar Gearbox operated with factory installed tamper switches 5

GATE VALVES Handwheel operated non-rising stem BS5163 OS&Y type flanged and grooved connection 300 psi/20 bar rated, UL, Post indicator type, non-rising stem 300 psi/ 20 bar rated, UL, Small bore threaded gate valves INDICATOR POSTS Horizontal wall post indicator, UL, Vertical post indicator (adjustable) UL, CHECK VALVES Grooved swing check valve, 350 psi/24 bar rated, UL, Flanged swing check valve, 350 psi/24 bar rated, UL, Size range 50mm upto 300mm Double door swing check valves Small bore threaded check valves 6

FLOW METERS LPCB - Grooved and Wafer design Sizes 50mm upto 200mm - Grooved, butt weld, and Wafer design Sizes 80mm to 300mm ELECTRICAL SWITCHES Flow switches CE, LPCB, UL,, Pressure Switch approved Pressure Switch LPCB approved OSY Gate Valve limit Switch BS5163 gate valve limit switch FLOW TEST PRODUCTS Test and drain valves with sight glass, UL, Single handle operation Threaded or grooved options available Zone assembly arrangement Size range 65mm upto 150mm includes pre wired isolation valve and flow switch 50mm drain and test connection 7

GROOVED COUPLINGS AND FITTINGS UL,, LPCB, Red Paint and galvanised finish Rigid and Flexible couplings Fittings include elbows, tees, mechanical tees, sprinkler tees, reducers, end caps, flange adaptors DRY RISER SYSTEMS Breeching Inlet valves, 2 and 4 way to BS5041 Landing Valve, flanged and threaded to BS5041 Air Release Valves Stainless steel & red finish inlet & outlet cabinets (bespoke cabinets on request) Galvanized pitcher tees, elbows, tees, couplings Support bracketry PRESSURE RELIEF / REDUCING VALVE Reducing valve - Globe or angle design available, UL Size range 40mm upto 200mm Threaded, grooved or flanged In line service Ductile iron special materials available Relief valve Globe or angle design, UL, Size range 50mm upto 250mm Flanged or grooved connections 8

FIRE HYDRANTS Dry barrel hydrant with duck foot bend Model RD-1510 - Size 51/4 - Approved Wet pillar hydrant available Y STRAINERS Flanged and grooved connections, UL listed Size range 65mm upto 300mm Maximum working pressure 12 Bar RESIDENTIAL SPRINKLER SYSTEMS Residential manifold Flow switches CE, LPCB, UL,, WRAS approved double check valve 9

CPVC CPVC fire sprinkler pipe and fittings for wet pipe systems Pipe sizes 20mm through to 80mm GEBERIT Zinc plated carbon steel plus stainless steel press fit pipe and fittings Pipe sizes 15mm through to 108mm MAINS WATER PUMPS SD80-100 l/min @ 2.4bar SD120-200 l/min @ 2 bar SD150 - OH1 15mt SD200 - OH3 15mt to OH3 45mt Sprinkler pump for tank system SD80T - 100 l/min @ 2 / 3 / 3 plus bar 10

DELUGE VALVES UL listed Sizes 80mm to 200mm Flanged connection, Globe or Angle Design Wet Pilot, Dry Pilot or Electric Actuation WATER SPRAY NOZZLES UL/ Approved Medium Velocity, High Velocity, Brass finish, stainless steel & aluminium bronze available Wide range of spray angle & K factors Water curtain nozzles Tank cooling nozzles FOAM EQUIPMENT Foam Bladder Tank Foam Chamber Foam proportioner/ratio controller Foam pourers Inline Foam inductor Ratio controller Foam concentrates 11

Rapidrop Global Ltd Rapidrop: A Global company, British manufactured British based manufacturer of fire sprinkler system products with international sales and distribution serving the needs of the fire detection and suppression industry worldwide. Europe Rapidrop Global Ltd Head Office Rutland Business Park Newark Road Peterborough PE1 5WA United Kingdom Telephone: +44 (0)1733 847 510 Facsimile: +44 (0)1733 553 958 E-mail: rapidrop@rapidrop.com Qatar Rapidrop Qatar LLC Salwa Road P.O.Box 17481 Doha Qatar Telephone: +974 4 0161 484/482 Fascimile: +974 4 0161 483 E-mail: uae@rapidrop.com South Africa Saudi Arabia Sales Office Imam Saud Road Cross Abu Berker Aj Siddiq PO BOX 54092 Riyadh 11514 Kingdom of Saudi Arabia Telephone: +966 (0) 114 549 255 E-mail: saudi@rapidrop.com India Rapidrop India Pvt Ltd Level 13, Office No. 1348 Platinum Techno Park Plot No.17/18, Sector -30A Vashi, Navi Mumbai, 400705 India Telephone: +91 22 6181 8348 Fascimile: +91 22 6121 4952 E-mail: rapidrop@rapidrop.com Approvals Middle East & North Africa Rapidrop Middle East Trading LLC P.O Box 232031 Dubai - UAE Telephone: +971 4 885 6671 Fascimile: +971 4 885 6672 Sharjah - Sales Office Telephone : +9716 556 2669 Abu Dhabi - Sales Office Telephone : + 971 2 5528228 E-mail: uae@rapidrop.com Asia Pacific Rapidrop International P.O Box 232031 Dubai - UAE Telephone: +971 6 566 2773 Fascimile: +971 4 885 6672 E-mail: rdi@rapidrop.com Social Media Rapidrop Global Ltd Talanalaan 281 Villieria Pretoria 0186 South-Africa The Rapidrop range includes products which have internationally recognised approvals and listings from /UL/VDS and LPCB. Telephone: +27(0)727601627 E-mail: rapidrop@rapidrop.com Assessed to ISO 9001-2008 Cert/LPCB ref. 556 201708