Faster Temperature (& Humidity) Chamber

Similar documents
Faster Temperature (& Humidity) Chamber

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Bench-Top Type Temperature (& Humidity) Chamber

Environmental Stress Chamber AR series

Compact Ultra Low Temperature Chamber

Thermal Shock Chamber TSE 11

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Compact design for personal use Ready to network with your computer.

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

Bench-Top Type Temperature (& Humidity) Chamber

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Thermal Shock Chambers

Thermal Shock Chambers TSA Series

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Environmental Stress Chamber

Thermal Shock Chambers

Temperature Chamber Series

Environmental Chambers

Temperature Chamber Series

Platinous J Series CAT.NO.E15110-Y1612

Environmental Stress Chamber

Walk-In Type Temperature (& Humidity) Chamber E Series

Highly Accelerated Stress Test System (HAST Chamber)

Benchtop Test Chambers. Temperature and Humidity

Environmental Chambers

Battery Charge/Discharge Test System Integrated with Temperature Chamber

Temperature Cycling Chambers Global-N Series

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Walk-In Type Temperature (& Humidity) Chamber E Series

Benchtop Test Chambers Temperature and Humidity

Technical Specification of High and Low Temperature Altitude Test Chamber

The best test chambers...

Customized Industrial Products

Chapter 8 Troubleshooting

Chapter 5 Inspection and maintenance

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Chapter 8 Troubleshooting

Chapter 7 Troubleshooting

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

The best test chambers...

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Daily maintenance and checks

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Pioneer in HAST Technology HIRAYAMA MANUFACTURING CORPORATION

UV Weather Resistance Test Chamber Technical Data

Dehumidifying Dryers DP DP 615 Series

Chapter 5 Inspection and maintenance

SN210/310/510, SQ510/810C

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

GCS-300 No.GCS31E

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

TCC-34. Features: TISSUE CULTURE

DESIGN & TECHNICAL MANUAL

DAIKIN Modular Inverter Air Cooled Chiller

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Chapter 7 Checks and Maintenance

Walk-in Test Chambers. Panelized & Solid Construction

Reproducible Climate...

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Refrigerated Incubators / Environmental Testing Chambers

Dehumidifying Dryers DP DP 615 Series

TCR. Features: TISSUE CULTURE

Products for Secondary Battery Market

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

SPC-56 SHORT PLANT.

CO₂ incubators. C CB series

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

Temperature Controllers TW, TO, TP Series

Temperature Control Systems

incubator, the best in its class

Constant climate chamber with humidity

Constant climate chambers

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

MD-S7000. All Electric Injection Molding Machine NIIGATA MACHINE TECHNO CO.,LTD.

Open Refrigerated Showcase. Instruction Manual

MDF-U333 MDF-U537 MDF-U537D

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

DESIGN & TECHNICAL MANUAL

Constant climate chamber with ICH-compliant illumination

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

HPLC Column Ovens and Temperature Controllers

Installation & Operation Manual

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Transcription:

Faster Temperature (& Humidity) Chamber SML2SMU2 SMS2SMG2 CAT.No.E04129-V1209

Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800 L capacity has been developed for reliability testing of increasingly large display devices to be used in automotive components, in car electronics systems, and more. This marks the arrival of a long-awaited large-capacity temperature and humidity chamber capable of providing a temperature change rate of 5/min. or more. The chamber is packed with numerous features, including a shorter time of delivery, thanks to its standardized component units. Lower power consumption, proper height for specimen setting, and other features. 1

2

Characteristics Temperature & Humidity Control Range 100 90 80 Relative 70 Humidity 60 (rh) 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 Temperature () 85 *When the chamber is operated below 30 to 40, continuous operation is restricted due to the dew condensation in the cooler (also functions as a dehumidifier). 98 Application of high stress of 5/ min. or more now possible This faster temperature (& humidity) chamber enables the application of high stress to the specimen at a steep temperature rate of change of 5/min. or more based on IEC60068-3-5, IEC60068-3-6 (without specimens loaded), thanks to the larger refrigeration systems installed in this series. The chamber features operation within wide temperature ranges: 70 to 180 and 40 to 180. Power consumption cut An improvement in the refrigeration system has resulted in lower power consumption in the large-capacity model temperature and humidity chamber. Simple replacement of wick The wick located at the upper rear of the test area must be replaced periodically in order to maintain high precision of humidity measurement at all times. To this end, the wick has been designed for easy replacement from the exterior. Wick installation (Test area) External view of wick (Right side) Free access of the chamber Since the machinery compartment is located in the back of the test area, virtually no maintenance space is required on either side of the equipment, enabling access either from the right or the left. Door unlocking system inside the chamber A door unlocking handle is installed inside the chamber, so that the door can be opened from inside, should someone be locked in by mistake. Right side 3

Characteristics Easy to set specimens For cases in which specimens are set in the chamber using a hand-lift, an insertion hole has been provided at the bottom of the chamber, and the test area has also been lowered, so that large-sized specimens and heavy articles can easily be inserted or withdrawn. New shelves structure (Japanese patent no.4418691) Due to the large size (1200mm wide 1500mm deep) of the test area, shelves are relatively heavy. With this in mind, shelves have been designed in a twopiece structure. Moreover, storage space is provided at the bottom of the device to hold the shelves. Test area (one set of shelves and shelf supports equipped as standard) Pocket for printed material A pocket is provided at the lower front of the chamber to store printed material such as the operation manual. Four models with 1800L capacity Two models are available for each of the temperature ranges from 40 to 180 /70 to 180, with a humidity model (from 20 to 98%rh) also available for each type. Thus, a chamber model can be selected from four models to suit the intended application at best. Paperless recorder (Optional) The paperless recorder makes it easy to record the temperatures of different components, such as the chamber temperature, on a memory card (Compact Flash or USB). *Outside dimensions change when attaching the paperless recorder. (see p.9) Shelves storage space Pocket 4

Control operation Instrumentation integrated into the door To minimize the required installation space for the device, the instrumentation section has been integrated into the door. The instrumentation produces indications on a bright, easy-to-view color LCD, which features an interactive touch-screen system. Remote control from your PC Please contact us for details on using a PC to monitor and remotely control the equipment. Program monitoring Alarm Program setting Service guide Instrumentation panel Temp. & Humid. controller Operating mode Display Setting Program capacity Setting ranges Setting resolution Input Control Interface Accessory functions Program operation, Constant operation TFT Color LCD (6.5in.) Interactive key input by touch panel User's patterns: 20 program patterns 99 steps per one pattern pattern linking possible ROM patterns: 10 program patterns Temp. : 75 to 185 Humid. : 0 to 100rh Time : 0 to 999 hours 59 minutes Temp. : 0.1 Humid. : 1rh Time : 1 minute Thermocouple type T (Copper/ Copper-Nickel) PID control RS-485 Time signal Input burn-out detection Upper and lower temperature & humidity limit alarm Self-diagnostic Alarm indication Power shut-off Timer preset (automatic start/stop) Refrigerator control mode Trend graph display Help 5

DIMENSIONS 100 (3.9) 1200 (47.2) 100 (3.9) unit : mm (inch) 1225 (48.2) 1900 (74.8) 450 (17.7) 50 (1.9) 1200(47.2) 1000 (39.3) 200 (7.8) 200 (7.8) 2726 (107.3) 1064 (41.8) top 1400 (55.1) 50 (1.9) 1200 (47.2) 2726 (107.3) 300 1500 (59.0) (11.8) 100 (3.9) 800 (31.5) front side 6

SPECIFICATIONS Model SML-2 SMU-2 SMS-2 SMG-2 System Balanced Temperature (& Humidity) Control system (BT(H)C system) Temperature range 40 to 180 (40 to 356) 70 to 180 (94 to 356) Humidity range 20 to 98rh 20 to 98rh Performance *1 Temperature fl uctuation 0.5 (40 to 100) 1.0 (101 to 180) 0.5 (70 to 100) 1.0 (101 to 180) Humidity fl uctuation 5rh 5rh Temperature gradient Temperature variation in space 3 3 Temperature rate of change 5/min. no specimen (Average) 5/min. no specimen (Average) Lowest attainable temperature 40 70 Exterior material Test area material Insulation Heater Cold-rolled rust-proofed treated steel plate 18-8 Cr-Ni stainless steel plate (2B polish) Glass wool Fin-type sheathed heater Construction Humidifying boiler Cooler Refrigeration unit 18-12-2.5 Cr-Ni-Mo stainless steal sheathed heater 18-12-2.5 Cr-Ni-Mo stainless steal sheathed heater Plate fi n cooler (Also works as a dehumidifi er) System Mechanical single stage refrigeration system Mechanical cascade refrigeration system Refrigerator capacity 7.5 kw 7.5 kw7.5 kw Refrigerator Scroll-type compressor, Water-cooled condenser, Cascade condenser (SMS, SMG only), Electronic expansion valve system, Refrigerant (R404A, R23 SMS, SMG only) Air circulator Sirocco fan (Direct-coupled electric motor type, 100 W4) Humidifying water supply Electrical conductivity Electrical conductivity water quality 0.1 to 10s/cm 0.1 to 10s/cm Supply water pressure 0.07 to 0.5MPa 0.07 to 0.5MPa Fittings Chamber total load resistance Inside dimensions (mm) *2 Outside dimensions (mm) *2 Capacity Viewing window (W340H440 mm), Chamber lamp, Integrating hour meter, Cable port2 (50 mm, each side) 100 kg W1200H1000D1500 (W47.2H39.3D59.0 inch) W1400H1900D2726 (W55.1H74.8D107.3 inch) 1800 L Weight 1250 kg 1400 kg Allowable ambient conditions Ambient temperature range: 0 to 40 (32 to 104) Cooling water temperature range: 5 to 32 (41 to 89.6) Utility requirements Power supply *3 200V AC 3 3W 50/60Hz 109 A 86 A 120 A 220V AC 3 3W 60Hz 97 A 75 A 109 A 380V AC 3 4W 50Hz 56 A 45 A 63 A 400V AC 3 4W 50Hz 57 A 45 A 64 A Cooling water supply pressure Cooling water supply rate 0.2 to 0.5MPa 2350 L/h (Reference temperature 25), 4400 L/h (Reference temperature 32) Piping connection size Noise level *4 32 A Max. 65dB *1 The performance values are based on IEC 60068-3-5:2001, JTM K07:2007, and IEC 60068-3-6:2001, JTM K09:2009. Performance figures are given for a 23 ambient temperature, a 25 refrigerator cooling water temperature, no specimens inside the test area and refrigerator capacity set to auto. *2 Excluding protrusions *3 Voltage fluctuation: 10% of rated value. *4 Noise level was measured in an anechoic room at a height of 1.2 m from the floor and a distance of 1 m from the chamber front panel (ISO 1996-1:2003 A-weighted sound pressure level). 7

MODEL SM- 2 ACCESSORIES Temperature & humidity range L : 40 20 to 98rh U : 40 S : 70 20 to 98rh G : 70 Cable port rubber plug (Silicone sponge rubber, 50mm) 2 Shelf brackets, 18-8 Cr-Ni stainless steel (Class CP) 1 set Shelf, 18-8 Cr-Ni stainless steel plate (front: 1160700mm) 1 (back: 1160700mm) 1 Cartridge fuse, Class A, 250V For SML, SMS, SMG 200, 380, 400V AC spec 5 220V AC spec 6 For SMU 200, 380, 400V AC spec 4 220V AC spec 5 Wet-bulb wick (For SML, SMS) 1 box Operation Manual 1 set SAFETY DEVICES Leakage breaker for power supply (200 to 380V AC spec.) Circuit breaker for power supply (400V AC spec.) Circuit breaker for refrigerator Boil dry protector (SML, SMS only) SSR overload and short circuit protecting circuit breaker Temperature switch for air circulator Control circuit overload and short circuit protection fuse Electrical compartment door switch Refrigerator high /low pressure switch Thermal fuse Temperature switch for compressor Specimen power supply control terminal Reverse-prevention relay Upper and lower temperature (& humidity) limit alarms (built-in temperature (& humidity) controller) Burn-out circuit (built-in temperature (& humidity) controller) Watchdog timer (built-in temperature (& humidity) controller) Overheat protector (independent type) Water suspension relay Circuit breaker for heater Circuit breaker for humidifying heater (SML, SMS only) Switch for humidifying boiler waterlevel detection (SML, SMS only) Wick insertion port switch (SML, SMS only) Safety precautions Do not use specimens which are explosive or inflammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or explosion. Do not place corrosive materials in the chamber. If corrosive substances or liquid is used, the life of the unit may be significantly shortened specifically because of the corrosion of stainless steel, resin and silicone materials. Be sure to read the operation manual before operation. 8

OPTIONS Paperless recorder Records temperature of each section such as the temperature inside the chamber. Recorder location: Top or Left side Size: 220210 mm *External dimensions change when attaching the recorder. (Please refer to the recorder location.) Data saving cycle: 5 sec. External recording media: CF memory card (256MB) USB port Language support: ENG, JPN [Temperature type] Temperature range: 100 to 200 Number of inputs (Initial setting): Temperature 1 (5 more channels can be turned ON) Temperature and humidity recorder (digital) [RJ15] 100 to 200 0 to 100%rh 6 dots Recorder location: Top or Left side Size: 220210 mm *External dimensions change when attaching the recorder. (Please refer to the recorder location.) Thermocouple Attached to specimen to measure specimen temperature. *Thermocouple type T (Copper/ Copper-Nickel) 2m 4m 6m Connecting terminal for temp. and humid. recorder Output terminals for chamber temperature and humidity. *Cannot be installed in conjunction with a recorder [Temperature and humidity type] Temperature range: 100 to 200 Humidity range: 0~100rh Number of inputs (Initial setting): Temperature 1 / Humidity 1 (4 more channels can be turned ON) Recorder location Top 220 unit:mm Temperature sensor terminal 210 Terminal boards for dry-bulb sensor in the chamber. (SMU, SMG only) Product temperature monitor Temperature recorder (digital) [RJ25] 100 to 200 6 dots Recorder location: Top or Left side Size: 220210 mm *External dimensions change when attaching the recorder. (Please refer to the recorder location.) Left side 220 210 When temperature measurement is performed on the specimen by the temperature sensor, the results are displayed on the instrumentation monitor screen. In programmed operation, the exposure time can be controlled, provided that the specimen temperature is within the available set temperature specifications. Measurement point: 1 Sensor in use: Thermocouple, Type T Appurtenances: Terminal board 1 Connecting position: Right side of the main unit (front) Accessories: Thermocouple, Type T 1 (0.32mm, 6m) Connector 1 9

OPTIONS Additional relay contacts Nine relay contacts (time signals) added. (Two contacts standard equipped) Integrating hour meter with reset Additional accessory to the standard hour meter, allowing reset. Additional cable port Provided in addition/replacement of the standard cable port (left-side). *Equipped with rubber plug. 25 mm 50 mm 100 mm Frost-free circuit Prevents frost from accumulating on the refrigeration circuit to allow longterm continuous operation. With models SMS and SMG, it is applicable with all chambers except those equipped with cascade refrigeration. Cable port rubber plug Comes with the cable port. Interface Serial interface: RS-232C Computer interface: GPIB *Select instead of standard RS-485. External alarm terminal If the safety device of the chamber is activated, the external alarm terminal will notify it to a remote point. Emergency stop push button Stops the chamber immediately. Additional overheat protector Additional preventive measures can be taken for excessive temperature rise in the chamber, in addition to the standard equipped overheat protector. Shelf, Shelf bracket Equivalent to standard accessory. Anchoring fixtures Used to bolt the chamber to the floor. Communication cables RS-485 RS-232C GPIB Power cable 5m/ 10m/ 30m 1.5m/ 3m/ 6m 2m/ 4m 5m 10m * AC 200, 220V only * The chamber does not come with a power cable. Overcool protector If the temperature inside the chamber decreases excessively, the chamber stops operating to prevent the specimens from being damaged. 10

http://www.espec.co.jp/english Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-5500 ESPEC NORTH AMERICA, INC. Tel : 1-616-896-6100 Fax : 1-616-896-6150 ESPEC EUROPE GmbH Tel : 49-89-1893-9630 Fax : 49-89-1893-96379 ESPEC (CHINA) LIMITED Tel : 852-2620-0830 Fax : 852-2620-0788 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-51036677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-10-64627025 Fax : 86-10-64627036 TIANJIN Branch Tel : 86-22-26210366 Fax : 86-22-26282186 GUANGZHOU Branch Tel : 86-20-83317826 Fax : 86-20-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-68028890 Fax : 86-512-68028860 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-68798008 Fax : 86-21-68798088 ESPEC SOUTH EAST ASIA SDN.BHD. Tel : 60-3-8945-1377 Fax : 60-3-8945-1287 Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2008 (JIS Q 9001:2008) through the Japanese Standards Association (JSA). Registration : ESPEC CORP. (Overseas subsidiaries not included) Environmental Management System Assessed and Registered ESPEC CORP. Specifications are subject to change without notice due to design improvements. TTA9B24C02 (The contents of this catalog is as of September, 2012.) Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.