Waters 2695 Separations Module

Similar documents
Waters 2695D Separations Module

Waters 2795 Separations Module

SystemsQT for Waters Alliance HPLC Systems (Revision G)

Agilent 1100 Series Autosampler Thermostat Reference Manual

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

ACQUITY UPLC HT Column Heater Instructions

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Agilent 1290 Infinity II Vialsampler Data Sheet

OVEN INDUSTRIES, INC.

Watchguard WGAP864 User Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

WeatherLink for Alarm Output Addendum

LineGuard 2300 Program User Manual (FloBoss 107)

ProStar 325 UV-Vis Detector

Installing the 30-cm Column Heater/Cooler

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Laptop / PC Programming Manual

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Agilent InfinityLab Online SPE Solution

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

CSP-204 CSP-208 CSP-104 CSP-108

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

tcu.z Commercial Programmable Thermostat Installation Instructions

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Model 3300 Technical Support and Installation Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

GV2 Series Control Panels

Operations Manual TS400. Test Station for G450/G460 Gas Detector

JOVY SYSTEMS RE User Manual Rev. 1.00

OPERATOR S MANUAL MR-2100/2200. Fire Alarm Control Unit. Revision 0 Document #: LT-2002

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

USER MANUAL. From version 1.00

SCAN200E USER S MANUAL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

Module Features are-configurable, no module jumpers to set

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Operating Functions Temperature Parameters

FLOW CONTROLLER TYPE S/601

QS941A Controller User Interface

IntelliDoX Operator Manual

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

Introducing New 96-Well Fast Plate Adapters for Applied Biosystems Capillary Electrophoresis Systems

Agilent 1290 Infinity Thermostat

Customised HPLC Systems for Highest Performance

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

- Data Brochure Snow Detector & Melting Control 665

PCS 2000 CONTROLLER USER GUIDE PCS 2000 CONTROLLER. Contents

SEC-MALS Noise Assessment and Cleaning Guide

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Before you install ProSeries Express Edition software for network use

DAY/TIME Button: Selects hour, minute and day setting.

Revised 12/14/2001. DC-5500 DC-5750 Operation Manual

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Fratech Multipath-IP

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

User Manual THR870CUK Programmable Thermostat

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Revised 10/3/2002. Ellis Intellitrol Washer Control Operation Manual

User Guide ems25plus. Page 1. Normal operation. Product interface

Agilent 1100 Series Refractive Index Detector. Reference Manual

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Vanquish. Split Samplers VH-A10, VF-A10. Operating Manual

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

T8611M Deluxe Programmable Heat Pump Thermostats

Troubleshooting Thermo Scientific LevelPRO Gauges

2000 Series. Program Entry Guide. Control Panels

Instruction manual. Remote control electric IR HEATER

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Fisher LCP100 Local Control Panel

S/601 Controller Installation Manual

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Monitoring Software for NPBC-V3M-1 User Manual

Security Escort. Operations Guide. Security Escort

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

Security System. User s Guide for the Text Command Center

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Intelligent Security & Fire Ltd

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

Programmable Load Management Thermostat

T8600D Chronotherm IV Deluxe Programmable Thermostats

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

48040M7K, 68036M5K, 72046M5K + Dryell

Static Pressure Control

Transcription:

S U P P L E M E N T A L R E L E A S E N O T E S Waters 2695 Separations Module Firmware Update Version 2.04 Firmware Update Version 2.04 Information This firmware update incorporates improved checking of vial position prior to injection of sample from that vial; this helps to confirm that the correct vial is being injected per programmed sample set sequence. These Supplemental Release Notes assume that the 2695 about to be upgraded with this firmware is already at V2.03. If this is not the case, contact Waters for a copy of earlier Supplemental Release Notes for information pertinent to that version. The information below is to be considered as an update to these manuals; Waters 2695 Separations Module Operator s Guide, Waters 2695 Separations Module Quick Start Guide and 2695 Separations Module Degasser Reference Sheet, all at Rev. B. Contents of this Release Waters 2695 Separations Module Firmware Update Version 2.04 Kit consists of: 2695 Firmware Update Disk, 1.44 MB, 3.5 inch Supplemental Release Notes (this document) Certificate of Structural Integrity System Qualification Letter Installation Notes The 2695 Separations Module firmware is updated by copying the software from the Waters 2695 Firmware Update Disk to the system FLASH ROM chips using the floppy disk drive on the front panel of the unit. Attention: If the floppy disk drive unit has not been used within the last month, it is advisable to exercise it before proceeding with the update by exporting a Separation Method or Sample Set. Since there is a possibility of a corrupt Method or Sample Set do not then import it. Attention: To prevent a mandatory service call to replace ROM chips, make sure that you do not power off the Separations Module during the software update procedure, unless specifically instructed to do so. To install the Update Version 2.04: 1. Insert the Waters 2695 Firmware Update Disk into the floppy disk drive on the front panel of the 2695. Waters, Alliance, MassLynx and Millennium are registered trademarks, PerformancePLUS and Empower is a trademark of Waters Corporation. All other trademarks are the sole property of their respective owners. Copyright 2007 Waters Corporation Page 1 of 8

2. Power on the 2695. The display will show A reprogramming utility was found. Press Enter to replace the current program. Press Clear to cancel and resume. Press Enter. 3. The display then shows Reading load utility from disk Please wait. 4. The display then shows Press ENTER to continue, Press CLEAR to abort and DO NOT TURN OFF THE POWER UNTIL FINISHED!!! At this point, the update disk begins a check of the file system and of the configuration and/or methods. 5. The display shows Checking file system.., then shows Checking configuration and methods.., and then shows No errors were found. and Press Enter to continue. Press Enter. This update assumes the 2695 being updated already has Version 2.03 firmware, which prevents creation of corrupted methods. After steps 1 through 5 the 2695 is now ready to complete the software update and the display asks; 6. Do you want to install the available methods? Press Enter for YES. Press Clear for NO. These methods are the Separation Methods and Sample Set AutoStartPLUS described above. Note: If you do not load these at this time you can Import them later (see the Waters 2695 Separations Module Operator s Guide). If you have previously loaded the AutoStartPLUS methods, they will be overwritten if you choose YES. If you press Enter the display shows Installing Methods and when complete shows Installing Version 2.04, Clear the display shows Installing Version 2.04, 7. When the display shows, Installing Version 2.04, Memory will be erased and reprogrammed! and the commands Enter to continue. and Clear to Abort., you should press Enter. 8. Last Warning! If you proceed, DO NOT turn off power!, is displayed, followed by Enter to continue. Clear to Abort. Press Enter. 9. The display then shows Checking Program Integrity.Please wait. After a few minutes the display then shows, Erasing Memory..Please wait and DO NOT TURN POWER OFF! TURNING POWER OFF NOW WILL MAKE YOUR SYSTEM UNUSABLE! 10. After the memory has been erased, the display shows, Loading Version 2.04 x percent complete and DO NOT TURN POWER OFF! TURNING POWER OFF NOW WILL MAKE YOUR SYSTEM UNUSABLE! The x percent complete represents the percentage of the new program that has been loaded and proceeds from zero (0) to one hundred (100) percent. 11. Once the entire program has been loaded, the display shows Program Load Complete! and instructs Remove Floppy Disk and cycle power. Remove the disk, turn the Separations Module power switch to the OFF position, wait approximately 5 seconds, and then turn the power switch to the ON position. The Separations Module will go through its initialization sequence. Progress of initialization is viewable in the banner area of the display and when complete, the banner area displays Idle. 12. Verify 2695 Separations Module firmware revision (2.04), creation date (Dec 19 2006 20:33:02) and checksum (7562C6E0H). From the 2695 Main Screen choose Diag, then Other Tests and scroll down to Firmware Checksum. The checksum is listed, and if internally correct, is followed by the letters OK. Note: If your instrument is in a regulated environment and the firmware checksum and version number are confirmed, then the Installation Qualification is complete. Refer to Instrument Qualification section of this Release Note. Page 2 of 8

Items Documented Prior to Product Shipment (Ver 2.04) Improved Checking of Vial Position Prior to Injection Version 2.04 firmware incorporates improved checking of vial position prior to injection of sample from that vial; this helps to confirm that the correct vial is being injected per programmed sample set sequence. This is accomplished via an improved carousel movement algorithm in conjunction with a smaller carousel encoder slot width parameter (now at 0.5 instead of 0.8 previously). After the carousel has been engaged and homed, all subsequent carousel movements are monitored using the carousel encoder slot sensor. If the slot sensor signature is incorrect, the carousel is re-homed and the move is retried. If the move fails a second time the "Carousel malfunction" alarm is raised. Between multiple injections from the same vial the carousel encoder slot sensor is monitored. If the carousel moves off the vial slot between injections it is re-homed and repositioned back to the correct vial. If the re-homing or repositioning fails they are retried. If the second attempt to re-home and reposition the carousel fails the "Carousel malfunction" alarm is raised. Instrument Qualification The 2695 V2.04 firmware provides improved checking of vial position prior to injection of sample from that vial, as noted above. These corrections and added functionality do not impact the actual functional performance of the instrument with respect to qualification, as long the stroke volume is manually set according to the required flow rate. Therefore, installation of 2695 V2.04 firmware in an instrument having the minimum hardware requirements, is not considered to be a major product change and will not require total instrument or system re-qualification. It is imperative to set the appropriate stroke volume for any and all existing methods before using them. Refer to the table shown on page 3 of these Supplemental Release Notes. If your Separations Module-based system is in a regulated (GXP) environment, Waters recommends that you perform the following procedures to verify consistent instrument/system performance before and after loading this firmware update. 1. Run system suitability analysis (on a well characterized standard) before and after installing this firmware update. Compare the results. If the before and after results agree to within the analytical method specifications, then the continued performance of the instrument/system is verified. 2. Record the check sum result to verify the firmware has loaded correctly. 3. Record the new firmware revision number in your GXP documents. Page 3 of 8

Items Documented Prior to Product Shipment (Ver 2.03 and earlier) Correct Use of Diagnostics Screens Whenever an operator (FSE and/or customer) is within Alliance diagnostics, it is very important that ALL diagnostic screens be exited before any external control (Millennium 32, Empower, MassLynx, etc.) is allowed. Failure to do so may cause unexpected behavior. Adding New Sample Vials During a Run To minimize the risk of a vial being missed when adding new vials to a carousel while the instrument is processing a sample set, the following guidelines should be followed; When adding samples, wait at least 30 seconds after an injection is made (i.e. wait until the run time displayed on the front panel, or within the controlling software, is greater than 30 seconds). Minimize the length of time that the sample compartment door remains open. It is also good practice to make sure the sample compartment door is closed when time injection commands (selecting vial, washing the needle, drawing sample, etc.) are in the process of being carried out. Re-initialization of the System It is good practice to re-initialize the instrument at least once a week: when all instruments (the 2695 and Detectors) are power-cycled (i.e., turn "off", wait for a minimum of 1 minute and then turn "on") on a regular basis), each instrument will perform a complete system initialization, including internal diagnostics and verifications. This helps ensure that the mechanical and electrical components as well as internal firmware, synchronize for proper operation. Minimizing Dust Ingress It is important that the optical sensors on a number of internal components not get covered in dust. If the instrument is in an area that is prone to accumulation of dust, Waters recommends the use of a Dust Filter Kit to minimize dust accumulation inside the instrument. This Filter Kit (includes floppy drive cover and rear panel plug) is standard on all 2695 s manufactured since December 2004, and are available as kits for earlier 2695 instruments. Improved Check Valve Performance As of June 2005, all 2695 Separations Modules and 2695 Performance Maintenance Kits have been delivered with PerformancePLUS check valves as standard; this check valve features a 1/8" ruby ball/sapphire seat. The original check valve (1/16" ruby ball/sapphire seat) is available as an option, along with 2 versions of ceramic check valve (ceramic ball and ceramic seat, either 1/8 or 1/16 ball diameter). Page 283 of the Appendix B (spare parts) of the 2695 Separations Module Operator s Guide should be amended as follows; The spare part number for the PerformancePLUS check valve is 700000254. The optional 1/16" ruby ball/sapphire seat check valve spare part number is WAT270941. The optional 1/16" ceramic check valve spare part number is 700002761. The optional 1/8" ceramic check valve spare part number is 700002399. Import of the Default Separation Method The 2695 Default Separation Method is resident in the 2695. It is not appropriate to attempt to import a method named Default, even if it was exported from the same unit. The creation of an invalid method may occur. System Control by Empower Chromatography Data System As stated in the 2695 Separations Module Operator s Guide, any parameter values not explicitly set in the Empower instrument method automatically take on the values in the Default separation method in the Separations Module. Page 4 of 8

These include: 2695-software-recognized column selection valves (3 column, 6 column and 2 column regeneration valves) Needle wash time selection of normal, double and extended If you wish to modify these values, verify that Idle is displayed in the banner area before you edit the Default Separation Method. When the 2695 is under Empower control, and actively running a sample, do not edit the 2695 Default Method. It is an improper operation to edit a running method via the 2695 front panel when under Empower Quick Set Control. Modification to Automatic Stroke Volume Functionality The information in Figure 6-3 ( Mobile Phase Screen ) in the Operator s Guide is incorrect. The figures below show the settable Stroke Volumes: The lowest recommended flow rate for a 2695 is 0.05 ml per minute, with an upper limit of 5.0 ml per minute. Composition Change Restriction The composition can no longer be changed from the Status page while the 2695 is under remote control. Optional PerformancePLUS Injector Needle In section 7.3.4 and Appendix B, Table B-2, of the Operator s Guide, the part number for the optional PerformancePLUS nickel/cobalt needle is incorrectly listed. The correct part number for the optional PerformancePLUS nickel/cobalt needle is 700001247. Carryover Specification in Appendix A In Appendix A, Table A-5, of the Operator s Guide, the specification for sample carryover is listed incorrectly as <0.1% UV detection (254 nm) or 20 ml, whichever is greater. The correct specification for sample carryover is <0.1% UV detection (254 nm) or 20 nl, whichever is greater. Page 5 of 8

Diagnostics Screen and the C/D Ratio The 2695 Diagnostics Screen is shown below. Figure 8-3 in the Operator s Guide is incorrect. Whenever an operator (FSE and/or customer) is within 2695 diagnostics, it is very important that ALL diagnostic screens be exited before any external control (Millennium 32, Empower, MassLynx, etc.) is allowed. Failure to do so may cause unexpected behavior. Autosampler Parameter Values The 2695 Autosampler Screen is shown below. Figure 6-6 in the Operator s Guide is incorrect. The operator has the ability to choose one of three options for needle wash duration as shown below. Normal, the default value, was the standard, non-programmable value in previous versions of software. The needle wash portion of the injection cycle operates for approximately 13 seconds when Normal is selected. In cases when excess carryover is seen, you may choose either Double (2X) or Extended (4X) to increase the length of time the needle is washed. The needle wash portion of the injection cycle is increased either by an additional ~13 seconds, or by an additional ~39 seconds, respectively if Double (2X) or Extended (4X) is chosen as compared to Normal. Page 6 of 8

Column Screen The 2695 Column Screen is shown below. Figure 6-7, in Section 6.2.4 of the Operator s Guide is incorrect. If a 2695-software-recognized column selection valve (3 column, 6 column and 2 column regeneration valve) is not installed, the Equilibration field is grayed-out and not available. If one of these valves is installed, and the Column Selection field is set to a choice other than No Change, the Equilibration field becomes active. The operator has the ability to specify an equilibration time that will be applied whenever the application of the Separation Method involves a change in the column switch position. The screen below describes this behavior and is available when the user presses the help key (?) with the cursor positioned in the Equilibration field. 2 nd Generation Column Heater & New Column Heater/Cooler Subsequent to publication of the 2695 Operator s Guide Rev. B (P/N 71500269502, Rev B), Waters has replaced the original Column Heater with a 2 nd generation Column Heater and introduced a new Column Heater/Cooler Module. Both of these modules are shipped with a copy of the Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A). The following notes update the column heater references within Rev. B of the 2695 Operator s Guide; Page 48 - under Power Supply should read The 2695 Separations Module is factory equipped with a 600 watt (W) power supply. This provides immediate compatibility for the addition of a column heater. Note that the Column Heater/Cooler module has its own built in power supply. Page 49 - under Column Heater should read The column heater allows you to maintain the column at temperatures from 5 C above ambient (minimum of 20 C) to 65 C. The upper temperature limit is 65 C and not 60 C. Page 52 the drawing shows the original column heater compartment. Refer to Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A). Page 78 under Adding Hardware Options, the Column Heater/Cooler should be added. Page 140 description against Column Temp parameter should also include Column Heater/Cooler. Page 7 of 8

Page 143 description against Equilibrate parameter should also include Column Heater/Cooler. Page 157 text within the Initial Conds paragraph should also refer to Column Heater/Cooler. Page 180 within Table 6-7, the following should be noted; The value range of 20 C (ambient + 5 C) to 60 C in 1 C increments for the Column Temperature Target Parameter pertains only to the original Column Heater. Refer to Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A), page 60 for values associated with the 2 nd Generation Column Heater and the Column Heater/Cooler. Page 184 text within the Action Parameters Table 6-10 should also refer to Column Heater/Cooler. Page 189 text within the 2410 and 410 Parameters Table 6-14 should also refer to Column Heater/Cooler. Page 233 text within the Other Diagnostics Screen under Section 8-3 should also refer to Column Heater/Cooler. Page 243 text within the Other Diagnostics Tests Table 8-3 should also refer to Column Heater/Cooler. Refer to Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A), page 72. Page 256 text within Section 8.4.11 under before you perform the test should also refer to Column Heater/Cooler. Page 257 text within Section 8.4.121 under before you perform the test should also refer to Column Heater/Cooler. Page 258 for information concerning the defrosting procedure of the Column Heater/Cooler, refer to Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A), page 72. Page 265 - text within the Chromatography Troubleshooting Table 8-9 should also refer to Column Heater/Cooler. Page 276 and 277 for information concerning the physical and performance specifications of the Column Heater/Cooler, refer to Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A), pages 81 to 83. Note that the original Column Heater, the 2 nd Generation Column Heater and the Column Heater/Cooler all share common dimensions. Page 280 - within Table A-6 the column heater specification should read 20 C (5 C above ambient) to 60 C, in 1 C increments for the original Column Heater only. The 2 nd Generation column heater specification should read 20 C (5 C above ambient) to 65 C, in 1 C increments. The upper temperature limit is 65 C and not 60 C. The Column Heater/Cooler specification should read 4 C (15 C below ambient) to 65 C, in 1 C increments. If a column heater (without cooler) is heating and a set point lower than the current temperature is entered, the column heater is commanded to stop heating. It will only resume heating when the temperature falls below the new set point. Subsequent to publication of the Alliance Series Column Heater and Column Heater/Cooler Operator s Guide (P/N 71500049202, Rev A), some improvements have been made to the Column Heater & Column Heater/Cooler modules that improve consistency of temperature control. The location of the temperature sensor has been changed within both the Column Heater & Column Heater/Cooler modules; the sensor is now located centrally within the compartment, between the 2 column mounting rails. This change has been in place since December 2005 for the Column Heater/Cooler, and since June 2006 for the Column Heater. Earlier modules can be updated to current standard please contact your local Waters office. Some changes have been incorporated into the door of the Column Heater & Column Heater/Cooler modules; the door contains an improved hinge mechanism and new foam inserts to better facilitate column outlet tubing connections to the detector module. This new door has been shipping as standard on both Column Heater & Column Heater/Cooler modules since May 2006. Earlier modules can be updated to current standard please contact your local Waters office. The original 120mA fuse used inside the Column Heater & Column Heater/Cooler modules has been changed to a 160mA fast acting fuse; this fuse has Waters part number 330000127. Page 8 of 8