Introduction. Emergency Systems Synergy Control Systems. Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9.

Similar documents
ONTENTS LITHONIA EMERGENCY. PSG Exit Signs 422. Architectural Emergency Units 432. Fluorescent Battery Packs 434

CONTENTS LITHONIA EMERGENCY SYSTEMS

NYC Approved Product Series

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

IOTA Exit Signs. IOTA Emergency Fixtures

The New Lux-Ray LED Emergency Lighting

TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25

Pictogram Exit Signs Catalogue

Exit/Emergency Lighting Guide

Nightfall. led emergency egress lighting

Catalog Number. Notes

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

PRODUCT OFFERING QUALITY VALUE VERSATILITY

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

Distributor Select LED Families

NEMA-4X Series. Certified for Harsh Environment Applications

Outdoor Emergency Lighting Application Guide

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Applications. Standard Materials

Spectron LSN (Life Safety Network) Suggested Specifications

Grüv Flare Regressed. Recessed Linear LED

Architectural / led luminaires

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

THE UNITED LIGHTING GROUP

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

3 2 1 A B D F

Grüv Flare Regressed. Recessed Linear LED

Lithonia Lighting LED Downlighting. A Solutions Guide For Every Need, Every Application, Every Budget

Power (max) Current (max)

Central Emergency Lighting Inverter Systems

New LED Product Offerings

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Bdl60u Fluorescent Emergency Ballast

SECTION INTERIOR LIGHTING

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

Enhancing the Lighting Experience

DHL-LP-LED Low Profile LED Linear High/Low Bay

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT

Exit Signs, Emergency Lighting & Fluorescent Emergency Ballasts

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

SECTION INTERIOR LIGHTING

DESIGN A SYSTEM WITH THE NORA RAIL:

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Catalog Number. Notes. Type

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

CHINESE NEW YEAR DEADLINE SOLUTIONS

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Fino Healthcare. Asymmetric Wall Mount Indirect LED

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

UNIFIED FACILITIES GUIDE SPECIFICATIONS

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

LED RETROFIT CONVERSION KITS

SECTION INTERIOR LIGHTING

BeveLED Cylinder LBRP6 Surface

LMV Series W Low Profile - Medium Base

Hornet HP. Round Glass Downlight

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

Moon Visions Lighting

Pathway Lighting. Introduction

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

Who is Iconic LED? Page 2. Phone:(337)

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

FLEXRAIL2 CONTENTS LINE VOLTAGE TRACK HEADS LOW VOLTAGE TRACK HEADS METAL HALIDE TRACK HEADS COMPACT FLUORESCENT TRACK HEADS FLEXRAIL2 PENDANT

A complete range of Specification Grade Emergency Lighting Products and Accessories ON THE PROJECT, ON THE SHELF, ON THE JOB

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

HIGH BAY APPLICATIONS

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

SECTION INTERIOR LIGHTING

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Evoke Square Downlight

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Fino. Asymmetric Wall Mount Indirect LED

Dublin airport - Dublin, Ireland

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

Hornet HP. Square Glass Downlight

Evoke Square Downlight

LED FIXTURE CATALOG. Shining light into the future

The Urban Farmer Store

Transcription:

Introduction Emergency Systems Synergy Control Systems { Systems Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9 EMERGENCY SYSTEMS Emergency lighting is required by building codes to ensure that a route to exit a building is clearly identified during an situation. Lithonia Emergency Systems manufactures a comprehensive selection of exit signs, lighting units, fluorescent battery packs and power systems for a wide range of commercial applications. Our extensive product offering includes architectural, commercial and industrial models in a choice of materials and light sources. A substantial range of options and accessories also is available. SYNERGY CONTROL SYSTEMS Lithonia Lighting produces a wide range of control systems for both architectural dimming and lighting energy management. These systems are suitable for a multitude of commercial applications. Lighting controls dramatically enhance efficiency by governing the amount of light needed to maintain illuminance levels and by limiting light use to occupied spaces. Lithonia offers a variety of lighting control solutions to meet ASHRAE 90.1 and similar legislation requirements. E2

Lithonia Emergency Systems CONTENTS Exit Signs E4 Emergency Lighting Units E9 Remote Lamp Heads E13 Battery Packs E14 Power Systems E16 E3

Edge-Lit Exits EXIT SIGNS Precise LED Suitable for architectural applications where aesthetics and superior performance are required. Injection-molded acrylic panels, ultrasonically welded to eliminate visible hardware. Depth of molded letters increases toward bottom of panel for better, more uniform illumination. Chevron directional indicators. Emergency operation exits use maintenancefree nickel-cadmium battery. Recessed mounting. Extruded aluminum housing recessed into wall or ceiling for top, back or end mounting capability. Surface top-mount (tm) option available on non exits and attaches directly to J-box. Can be used for pendant mounting. Special wording available; consult factory. Top Mount Long-life LEDs feature very low energy consumption and rated life up to 25 years. UL Listed (standard). Example: LRP BS 1 RC LA 120/277 EL N EM Back Mount Chevron Direction Panel/Trim Assembly LRP LED Housing color Brushed aluminum W White B Black BZ Bronze BS Brass CR Chrome Number of faces 1 Single 2 Double Panel color letter/background RW Red on white RC Red on clear 1 RMR Red on mirror 2 GW Green on white GC Green on clear 1 GMR Green on mirror 2 Input voltage 120/277 Dual voltage Operation non- EL N Nickel-cadmium battery X2 Lamps wired on two separate circuits 6 Directional indicators No chevrons LA Left RA Right LRA Left and right DA Double-face chevrons Mounting Ceiling or back EM End TM Top 3 PNL Item type Complete exit panel and rough-in section Panel assembly only Certification UL Listed RECESSED END MOUNT Panel length (from wall): 13-1/2 (343) Panel height: 10 (254) Trim height: 14-3/4 (375) Panel depth: 1-7/8 (47) Weight: 5 lbs. (2.3 kgs.) RECESSED BACK MOUNT Panel length: 13-1/4 (336) Trim length: 14-3/4 (375) Total height: 11-1/2 (292) Depth (from wall): 1-7/8 (47) Weight: 5 lbs. (2.3 kgs.) Rough-In Section RECESSED CEILING MOUNT Panel length: 13-1/4 (336) Trim length: 14-3/4 (375) Height (below ceiling): 8 (203) Trim width: 5 (127) Weight: 5 lbs. (2.3 kgs.) TOP MOUNT ( non- only) Panel length: 13-1/4 (336) Trim length: 13-1/8 (333) Panel height: 8 (203) Weight:5 lbs. (2.3 kgs.) Length: 13-5/8 (346) Width: 4-1/2 (114) Depth: 3-1/8 (80) Accessories 4 (Order separately) LED Rough-In Section 5 ELA LCRIS 1 or 2 face red or green ELA LRIS 120 X2 1 or 2 face 120V w/ X2 option ELA LRIS 277 X2 1 or 2 face 277V w/ X2 option Emergency ELA R LRIS 120/277 EL N 1-face red ELA R 2LRIS 120/277 EL N 2-face red ELA G LRIS 120/277 EL N 1-face green ELA G 2LRIS 120/277 EL N 2-face green Pendant Mounting (Top mount only) ELA US12 12" pendant kit with brushed aluminum canopy Type Volts Faces Amps Watts Primary Circuit 120 1.087 1.5 120 2.178 3.1 LED Red 277 1.089 1.8 277 2.178 3.4 120 1.093 2.3 Emergency 120 2.084 3.2 LED Red 277 1.095 2.7 277 2.094 3.9 120 1.064 1.2 120 2.059 2.0 LED Green 277 1.062 1.3 277 2.061 2.3 120 1.066 1.7 Emergency 120 2.138 3.7 LED Green 277 1.064 1.9 277 2.130 3.8 1 Single-face exits only. 2 Mirror background simulates clear for double-face option. 3 Non- exits only. No rough-in section required. 4 For additional options, accessories and fixture compatibility see page ES21. 5 Supplied standard with exit unless PNL suffix is specified. Order separately only if necessary for early installation. When ordering rough-in separately, all options must be included with rough-in nomenclature. Example: ELA LCRIS 120/277 FI 6 Must specify input voltage 120 or 277. E4

Surface Mount Edge-lit Exits Suitable for applications requiring attractive edgelit exit signage, universal installation and low energy consumption. Extruded aluminum or white finish lamp housing. Clear thermoplastic panels with precision outline engraved letters measuring 6" high with 3 /4" stroke. Single face on clear background. Double face on mirrored separator panel to simulate clear background. Expected LED life over 10 years. Low energy consumption less than 5 watts. Universal (top, end or back) mounting. Double face available with top or end mounting only (canopy provided). Universal directional indicators. Field selected and attached. UL Listed (standard). Meets NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. EDG LED EXIT SIGNS Example: EDG 1 R EL EDG Surface mount LED edge-lit Housing color Aluminum W White Number of faces 1 Single 2 Double Letter color R Red G Green EL SD 1 X2 Operation non- Nickel-cadmium battery Self Diagnostic (available with EL option only) Provides primary and secondary AC input (available with green letters and AC operation only) Type Volts Amps Watts Primary Circuit LED Red 120 0.21 2.52 277 0.10 2.77 LED Green 120 0.18 2.16 277 0.08 2.20 Emergency LED Red 120 0.25 3.00 277 0.11 3.05 Emergency LED Green 120 0.22 2.64 277 0.10 2.77 1 Consult factory. End Mount Top Mount Test Switch Pilot Light (Emergency Only) Back Mount Width: 13-5/8 (345) Height: 11-3/4 (299) Depth: 4-3/8 (110) Width: 4-3/8 (110) Height: 11-3/4 (299) Depth: 13 (330) Width: 13 (330) Height: 12-1/2 (318) Depth: 2-3/8 (59) Shipping weight 4lbs. (1.81 kgs.) E5

Die-Cast Aluminum Exits EXIT SIGNS Signature LED Ideal for applications requiring attractive diecast aluminum signage, superior illumination and low energy consumption. LEDs provide uniform graphics illumination. Meets 3 /4" letter stroke requirements. Maintains 100% brightness in mode. Emergency exits contain maintenance-free nickel-cadmium battery and reliable, solidstate charging system. Solid, die-cast aluminum housing smallest sign on the market. finish is brushed aluminum face with matte black housing. Other finishes available. The self-diagnostic signs comply with NFPA Life Safety Code and automatically tests the battery once a month for five minutes and once every six months for 30 minutes. Universal mounting top, back or end. Double face available with top or end mounting only (canopy included). US patent no. 5,954,423. UL Listed (standard). Completely concealed chevron directional indicator knockouts and mounting hardware. Long-life LEDs feature very low energy consumption and rated life up to 25 years. A non- red LED exit consumes only.73 watts of electricity at 120 volts. Example: LE S W 1 R 120/277 EL N SD LE LED LRE LED recessed Face type S Stencil Housing color BZ W B Brushed aluminum face & matte black housing Dark bronze White Matte black Number of faces 1 Single 2 Double Panel color R Red G Green Input voltage 120/277 Dual voltage EL N EL N SD X2 Operation non- Nickel-cadmium battery 1 Nickel-cadmium battery with self diagnostics Lamps wired on two separate circuits 2 Certification UL Listed LED End Mount Top Mount Back Mount Width: 11-3/8 (289) Height: 7-7/8 (200) Depth: 1-3/4 (45) Add 2-1/4 (57) for canopy Weight: () 5 lbs. (2.3 kgs) (Emergency) 8 lbs. (3.6 kgs) Recessed Width: 13 (329) Depth: 4 (102) Height: 9-1/2 (240) Weight: () 10 lbs. (4.5 kgs) (Emergency) 13 lbs. (5.9 kgs) Accessories 3 notes: 1 Not available with recessed exits. 2 Must specify input voltage 120 or 277. 3 For additional accessories see page ES21. 4 Add W for white canopy. 5 For use with exits only. (Order separately) ELA B US12 12" pendant kit with black canopy 4 ELA LEHO 120/277 N Remote capable with black canopy. Provides 90 minutes of 10.2 watt capacity for remote head 4,5 Type Volts Faces Amps Watts Primary Circuit 120 1 or 2.04.73 LED red 277 1 or 2.05.94 120 1 or 2.04 1.2 LED green 277 1 or 2.05 1.5 E6

Labor-Saving Exit/Unit Combos Suitable for applications requiring quick-installation of both exit sign and unit equipment. Attractive 10-inch tall, streamlined design is great for above the door applications and other tight fits. UV-stabilized thermoplastic housing resists discoloration from sunlight and man-made sources. Quick-Mount installation. Innovative, snaptogether design allows for installation in less than three minutes. Factory assembled and prewired. Replaceable chevron directional indicator knockouts for choice of direction. Side-mount lamp heads reduce overall height, allowing for easy fit over doorways. Long-life LEDs feature very low energy consumption and rated life up to 25 years. 120/277 dual input voltage standard. Sealed, maintenance-free, lead-calcium battery standard. Nickel-cadmium battery optional. Two 5.4W wedge-based krypton lamps offer 32 percent more light output than standard incandescent lamps. Patented MR24, multi-faceted reflector significantly improves photometric performance; 60 to 100 percent more light delivered to the path of egress. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Top, back or end mounting (canopy included). Optional high-output battery (HO) to power a remote head or exit. U.S. Patent No. 5,611,163, 5,646,502, 5,526,251, 5,797,673 and D379,373. Other patents pending. UL Listed (standard). Damp location listed standard. Quantum LED Quick-Mount EXIT SIGNS Example: LHQM S W 3 R LHQM LED exit/unit Face type S Stencil Panel P 1 Housing color Black W White Number of faces 3 Single with extra faceplate and color panel Panel color R Red G Green N Nickel-cadmium battery 2 HO High-output lead- calcium battery R0 HO Less lamp heads high-output lead- calcium battery Accessories ELA MR24 K0606 ELA MR24 K0906 ELA NX H0606 ELA WGHQM (Order separately) Compact MR24 remote head (6W, 6V krypton lamp) Compact MR24 remote head (9W, 6V krypton lamp) NEMA 4X sealed-beam remote fixture (6W, 6V halogen lamp) Wireguard (backmount only) Remote Output Capacity Combo/ Combo/no Combo/ high- heads (R0) & ni-cad output high-output combo battery (N) battery (HO) battery (HO) LHQM NA NA 12 W 24.0 W Electrical Lamp AC Lamp AC Input Output Output Watts Catalog Description Volts Amps Watts Volts 1.5 hrs. 2 hrs 3 hrs. Number Watts 120.23 3.3 6 14 10 7 Red LED 277.23 3.3 6 (HO) 24 18 12 MR24 K0606 5.4 120.23 3.3 6 14 10 7 Green LED 277.23 3.3 6 (HO) 24 18 12 MR24 K0606 5.4 1 For custom signage only. Special wording available on panel face, white housing with red letters only. Consult factory. Not available with SD, SDFIFA or X2 operation. 2 Not available with HO. Width: 21-1/4 (539) Depth: 4 (102) Height: 9-7/8 (250) E7

EXIT SIGNS Contemporary Thermoplastic Exits Quantum LED Quick-Mount Ideal for applications requiring attractive, quick installation exit signs and low energy consumption. Precision-molded thermoplastic housing is impact and scratch resistant, corrosion proof and UV-stabilized to resist discoloration. Innovative snap-together design allows installation in less than three minutes. Long-life LEDs feature very low energy consumption and rated life up to 25 years. Consumes less than one watt of energy. Fully assembled single-face exit with optional extra faceplate for easy field conversion to double face. Replaceable chevron directional indicator knockouts for choice of direction. Universal mounting capability top, back or end (canopy provided). Automatic recharge after discharge. Conveniently located test switch and status indicator provide visual and manual means of monitoring system operation. The self diagnostic signs comply with NFPA Life Safety Code and automatically test the battery once a month for five minutes and once every six months for 30 minutes. U.S. Patent No. 5,526,251, 5,611,163, 5,739,639 and 5,954,423. Other patents pending. UL Listed (standard). NOM Certified (see ). Damp location listed standard. Example: LQM S W 3 R 120/277 EL N SD LQM Face type S Stencil Panel P 1 Housing color Black W White Number of faces 3 Letter color R Red G Green Input voltage 2 120/277 EL N SD 3 SDFIFA 3 X2 4 Operation AC operation Nickel-cadmium battery Self-diagnostics Self-diagnostics, fire alarm flashing interface and flashing operation and intermittent audible alarm (one flash/one sec.) Provides primary and secondary AC input Certification UL 924 Listed NOM 5 NOM Certified Accessories (Order separately) ELA W US12 12 stem kit with white canopy 6 ELA WGEX Back-mount wireguard ELA WGEXT Top-mount wireguard ELA WGEXE End-mount wireguard End Mount Top Mount Back Mount Width: 11 (298) Height: 7-5/8 (193) (Add 7/8 (22) for canopy) Depth: 2 (49) 1 For custom signage only. Special wording available on panel face, white housing with red letters only. Consult factory. Not available with SD, SDFIFA or X2 operation. 2 Some special voltages available. Consult factory. 3 Available with EL N operation only. 4 Available with AC operation only. 5 Available with Stencil or Panel faces in white housing and red letters only. 6 Replace "W" with "B" for black canopy. Type Volts Amps Watts Primary Circuit 120.04.57 LED red 277.05.68 120.05.62 LED green 277.05.72 Emergency 120.04.72 LED red 277.92.92 Emergency 120.04.72 LED green 277.05.92 E8

Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. White, compact, low-profile contemporary design with high-impact thermoplastic housing that is impact-resistant, corrosion-proof and UV-stable to resist discoloration from artificial light sources or sunlight. Maintenance-free lead-calcium battery. Two 5.4W wedge-based krypton lamps offer 32 percent more light output than standard incandescent lamps. Patented MR24, multi-faceted reflector (ELM2) significantly improves photometric performance; 60 to 100 percent more light delivered Contemporary Thermoplastic Emergency Lighting Units to the path of egress. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Unique track-and-swivel design permits full range of lamp head adjustment (ELM2). Universal J-box mounting pattern. Tool-less access for maintenance. Flexible conduit entry provision on top of the unit. Quick-Mount snap-together construction permits installation in three easy steps in less than three minutes. Vandal-resistant ELA VS polycarbonate shield available. Wall or ceiling mounted. UL Listed (standard). NOM Certified (see ). Quantum ELM2 ELM/ELM2 Quick-Mount ELM EMERGENCY LIGHTING UNITS Example: ELM2 SD ELM 6V,12W ELM2 6V,12W SD Self-diagnostics 1 B Black housing DL Damp locations -10 to 40 C (50-140 F) CSR 6-foot cordset attached 2 NOM NOM Certified 1 Accessories ELA VS ELA WGST (Order Separately) Polycarbonate vandal shield Wireguard AC Input Output Output Watts Type Volts Amps Watts Volts 1½ hrs ELM 120.11 1.2 6 12 277.12 1.5 ELM2 120.11 1.2 6 12 277.12 1.5 1 Available on ELM2 only. 2 Available on ELM only. Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (millimeters) unless otherwise noted. ELM Width: 11-1/2 (292) Depth: 3-3/4 (95.25) Height: 5 (127) ELM2 Width: 12-1/2 (317) Depth: 3-3/4 (95.25) Height: 5 (127) E9

EMERGENCY LIGHTING UNITS Concealed Emergency Lighting Units Velaré Provides 90 minutes of illumination for the rated wattage upon the loss of AC power. Ideal for applications that require ensconced lighting in wall or ceiling. Trim and door housing panels are finished in durable white textured powder coated paint. Can be wallpapered or field painted. Trim and panel doors lay flush with mounting surface. No exposed hardware. Low profile recessed test switch and status indicator configuration minimizes exposed interfaces. Rugged, 22 GA galvanized steel box with (3) 3/4 knockouts. Galvanized bar hangers span up to 30 on center. Two MR16 halogen 12W to 75W lamps are fully adjustable to meet aiming requirements. Lamps are ensconced until activated in the mode. Sealed, maintenance-free lead-calcium battery with capacity of 24W to 150W for 90 minutes of operation. Optional nickel-cadmium battery. Low voltage disconnect prevents excessive deep discharge that can permanently damage the battery. Dual voltage input capability (120/277V). Precision-controlled motor and cam system ensures reliable extraction and retraction of light sources. Single, multi-chromatic LED indicator to display two-state charging, test activation and four-state diagnostic status. selfdiagnostic feature tests the unit for 30 minutes every 28 days without turning lamps on. Provided with an IR receiver for remote testing. Requires the ELA RTVEL remote transmitter (see accessories). Selectable 30-second or 90-minute manual testing. UL Listed (standard). Example: VEL1270 H3512 N VEL1224 12V, 24W VEL1240 12V, 40W VEL1270 12V, 70W VEL12100 12V, 100W VEL12150 12V, 150W Lamp type 1 H1212 12W/12V halogen MR16 H2012 20W/12V halogen MR16 H3512 35W/12V halogen MR16 H5012 50W/12V halogen MR16 H7512 75W/12V halogen MR16 N Maintenance-free nickel-cadmium battery Accessories (Order Separately) TD Time delay LRIS Less rough-in section ELA RTVEL Remote transmitter with selectable 30-second or 2 90-minute testing 3. ELA VEL RIS VEL rough-in section (supplied standard with fixture unless LRIS suffix is specified) ships with mounting hardware only. Order ELA VEL RIS if needed for rough-in phase of construction. Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted. 7-5/8" 13-1/2 Rough-in opening 14-1/2" 16 Depth behind wall for 3/4" wall thickness = 3-1/4" Total depth = 4 13-1/2 to 30 6-3/4" Rough-in opening Universal adjusted mounting rails. Two per unit mount on 13-1/2" or 16" sides. VEL1224 (12V, 24W) 20 lbs. VEL1240 (12V, 40W) 20 lbs. VEL1270 (12V, 70W) 26 lbs. VEL12100 (12V, 100W) 26 lbs. VEL12150 (12V, 150W) 32 lbs. Rough-in opening: 13-1/2 (341) X 6-3/4 (170) Overlap trim: 14-7/16 (365) X 7-5/8 (193) AC Input Output Output Watts Type Volts Amps Watts Volts 1-1/2hr. Primary Circuit VEL1224 120.20 30 12 24 277.20 30 12 24 VEL1240 120.20 30 12 40 277.20 30 12 40 VEL1270 120.20 30 12 70 277.20 30 12 70 VEL12100 120.20 30 12 100 277.20 30 12 100 VEL12150 120.20 30 12 150 277.20 30 12 150 1 Two lamps provided. Total lamp load cannot exceed the fixture capacity rating. 2 VEL rough-in section ships standard with fixture unless LRIS suffix is specified. Requires ELA VEL RIS accessory for installation. 3 Minimum one per job required. E10

Provides a minimum of 90 minutes illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment. Compact, low-profile, architectural design with die-cast aluminum housing that has a contemporary brushed nickel-plated finish. Other available finishes are texturized polyester powder coat paint in white, black and dark bronze. U.S. Patent No. D468,046. Two 6W wedge-base xenon lamps offer 55 percent more light output than standard incandescent lamps. Patent-pending reflector/refractor design features superior vac-metalized, die-casted reflectors and multi-faceted, highly transmissive refractor that significantly improve photometrics. Maintenance-free lead-calcium battery (as a standard). Nickel-cadmium optional. The self-diagnostic option complies with NFPA Life Safety Code and automatically tests the battery once a month for five minutes and once every six months for thirty minutes. Dual-voltage input capability (120/277V). Low-profile, integrated test switch/pilot light located below the lens. Rigid conduit entry provision on top of the unit. Remote version available for exterior use. Ideal for exit discharge applications. UL Listed (standard). Wet location (EXT) listed. Damp location (PREM, EXT) listed. Cold Weather (EXT) listed. Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. Die-Cast Architectural Emergency Lighting Units Affinity EMERGENCY LIGHTING UNITS Example: AFN BN PREM AFN Input voltage 120/277V Finish W White B Black BN Brushed nickel DB Dark bronze 1 PREM EXT Option packages lead-calcium battery nickel-cadmium battery, self-diagnostics and damp location 0 to 50 C (32 to 122 F) high-temperature nickel-cadmium battery listed from -18 to 50 C (0 to 122 F), selfdiagnostics, time delay, damp and wet location Accessories ELA AFNR DB (Order Separately) Remote fixture (less batteries and electronics) to be powered by 6V battery equipment as part of an lighting system (listed from -40 C to 60 C) 2 AC Input Output Output Watts Type Volts Amps Watts Volts 1-1/2 hrs AFN 120.11 1.1 6 12 277.12 1.3 AFN PREM 120.15 1.4 6 12 277.14 1.4 AFN EXT 120.23 21 6 12 277.25 35 1 Dark bronze can only be ordered with the exterior package. This finish is not available on other units. 2 To order white, black or brushed nickel, replace DB with W, B or BN. For fixture performance charts, see page EL24. Width: 6-1/2 (165) Depth: 2-7/10 (69) Height: 9-1/2 (241) Weight: 3.5 lbs. (1.59 kgs.) E11

Recessed Emergency Lighting Units EMERGENCY LIGHTING UNITS ELR SD N R0 H CDS N1812 N2512 H1212 TD Self diagnostic (ELR4 only) Maintenance-free nickel-cadmium batteries Less lamp heads 6V/8W or 12V/8W halogen lamps Compact designer square lamp heads 18W/12V incandescent lamps 25W/12V incandescent lamps 12W/12V incandescent lamps Time delay (12V only) PAR36 Length: 12 (303) Width: 12 (303) Depth: 5-7/8 (149) below ceiling plane Weight: (ELR2) 16 lbs. (7.3 kgs.) (ELR4) 22.5 lbs. (10.2 kgs.) Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications that require attractive unit equipment or when wall mounting is undesirable. Heavy-duty recessed housing suitable for use in air-handling plenums. PAR36 lamp heads standard; compact designer square lamp heads optional. Example: ELR2 CDS Lamp Catalog Watts/ Type SD N R0 H CDS N1812 N2512 H1212 TD NOM Number Lamp ELR2 N0806 8 ELR2P N N0806 8 ELR4 N1212 12 Special voltages/frequencies available; consult factory. For additional lamp heads, remote fixtures, options and accessories, see pages EL16. Compact Designer Square Length: 12 (303) Width: 13-3/8 (340) Depth: 2-3/4 (70) below ceiling plane Weight: (ELR2 CDS) 15 lbs. (6.8 kgs.) (ELR4 CDS) 22.5 lbs. (10.2 kgs.) Sealed, maintenance-free battery (lead-cal cium stan dard, nickel-cadmium optional) provides capacity for 90 minutes of illumination. Sturdy T-bar clips secure unit to grid members. Adjustable bar hangers for easy mounting in walls and exposed or concealed suspended ceilings. UL Listed (standard). Option available Option not available AC Input Output Output Watts Volts Amps Watts Volts 1-1/2 hrs 2 hrs 3 hrs 4 hrs ELR2 120.167 20 6 16 12 8 6 277.072 20 ELR2P N 120.167 20 6 24 18 12 9 277.072 20 ELR4 120.250 30 12 50 37 25 18 277.108 30 Recessed Gimbal Emergency Lighting Unit ELRG Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring unobtrusive lighting. Matte white, baked enamel finish. All-metal housing and gimbal assembly. High-output, 8W halogen lamp. Lamp adjusts in two planes to 26. Low-profile pilot light and test switch. Approved for use in air-handling plenums. Maintenance-free lead-calcium battery. Mounts in 6" diameter opening. UL Listed (standard). 8-1/2 (216) 18-1/2 (470) 10 (254) 8-1/2 (216) 8-1/2 (216) 7-1/2 (191) ELRG Height: 7-1/2 (191) Length: 10 (254) Width: 18-1/2 (470) Ceiling opening: 8-1/2 (216) Example: ELRG AC Input Type Volts Amps Watts ELRG 120.052 5.8 277.023 5.9 6V, self-contained recessed gimbal E12

Remote Lamp Heads Lamp heads on this page can be ordered as separate fixtures, or as individual or twin remote heads with a mounting plate. To Order Remotes: Order as separate line items. Emergency lighting accessory ELA B W ITN Color color Black White Instrument tan (Titan Series match). Available on standard PAR36 and NX head only Number of lamps T Single Twin MR24 CDS SSB Lamp head style PAR36 IND Multi-faceted reflector NX Compact designer square MT Square PAR36 Z Indura Sealed and gasketed PAR36 Metal PAR36 Hazardous PAR36 (Class I, Division II) Example: ELA IND H2012 Lamp type Select from lamp compatibility chart at bottom of the page. (For Indura sealed beam lamps add suffix S to lamp nomenclature. Example: H35I2S) lamp COMPATIBILITY PAR36 Width: 4-3/4" (121) single head, 13" (330) twin heads Height: 7-3/4" (197) Depth: 5-1/16" (129) color: Desert tan Multi-Faceted Reflector MR24 Width: 4-5/8" (117) single head, 6-5/8" (168) twin heads Height: 6-5/8" (168) single head, 4-1/2" (114) twin heads Depth: 2-1/2" (63) color: White Quantum match Compact Designer Square CDS Width: 3-7/8" (98) single head, 10-5/8" (270) twin heads Height: 4-1/4" (108) Depth: 4-1/8" (107) color: Ivory white Square PAR36 SSB Width: 4-3/4" (121) single head, 10-1/2" (267) twin heads Height: 5" (108) Depth: 4-1/2" (107) color: White Indura Remote IND Width: 5-7/8" (149) single head, 7-1/8" (181) twin heads Height: 5-1/8" (130) Depth: 5-3/8" (137) color: Gray head and mounting plate, blue lamp housing Sealed & Gasketed PAR36 Metal PAR36 Hazardous PAR36 Width: 4-3/4" (121) single head, Width: 4-5/8" (118) single head, Width: 13" (330) twin heads 110-1/2" (267) twin heads Height: 7-3/4" (197) Height: 5-1/8" (130) Depth: 5-1/16" (129) Depth: 6-1/2" (165) MX color: Gray MT finish: Chrome Z color: Optional finish: White 4-3/4" (121) single head, 13" (330) twin heads Height: 7-3/4" (197) Depth: 5-1/16" (129) Gray Z Series match For photometric information, visit our website at www.lithonia.com. Consult factory for additional lamp availability. Dimensions are shown in inches (millimeters) unless otherwise noted Composite Lamps 6 Volt 12 Volt 24 Volt Incandescent Halogen Krypton Incandescent Halogen Krypton Incandescent Halogen Lamp Type N0606 N0806 N0906 H0606 H0806 H1006 H1206 H2006 K0606 K0906 N0912 N1212 N1812 H0812 H1212 H2012 K0912 N0924 N1824 H2024 Wattage 6W 8W 9W 6W 8W 12W 20W 6W 9W 9W 12W 8W 12W 20W 9W 9W 18W 20W MR24 CDS IND Sealed-Beam Lamps Available Not available 6 Volt 12 Volt 24 Volt Incandescent Halogen Incandescent Halogen Incand. Lamp type N0606 N0806 N1206 N1806 N2506 H0606 H0806 H1206 H2006 N1212 N1812 N2512 N3512 N5012 H0812 H1212 H3512 H5012 N5024 Wattage 8W 12W 18W 25W 6W 8W 12W 12W 18W 25W 35W 50W 8W 12W 35W 50W 50W SSB IND NX PAR36 MT Z Available Not available E13

Reduced-Profile Fluorescent Battery Packs, Linear Fluorescent Fixtures BATTERY PACKS Power Sentry Factory- or field-installed inside or outside (field only) a fluorescent fixture to operate lamp(s) at an initial output of 10% to 95% of rated lamp lumens, providing optimum glarefree illumination for a minimum of 90 minutes upon interruption of normal power. Quick-Disconnect connector system allows for quick and easy replacements at end of life without re-wiring. U.S. patent No. 5,814,971. UL Listed. Damp location listing available. Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Reduced-profile footprint fits in the tightest application. Durable thermoplastic/metal housing resists impact, scratches or corrosion. Sealed, maintenance-free, high-temperature nickel-cadmium batteries. Example: PS1400QD SD PS300QD Reduced profile, Quick-Disconnect, 300 lumen output 1 PSQ500QD Reduced profile, Quick-Disconnect, 15-minute installation, 500 lumen output 1 PS600QD Reduced profile, Quick-Disconnect, 600 lumen output 1 PS1400QD Reduced profile, Quick-Disconnect, 1400 lumen output 1 SD Self-diagnostics 2 DW UL Listed for use inside damp or wet location listed fixtures 0-50 C (32-122 F) 3 Factory installation 4,5 EL PS300QD installed 4,5 EL5 PSQ500QD installed 4,5,6 EL6 PS600QD installed 4,5,6 EL61LP PS600QD one-lamp operation installed 4,5,6 EL14 PS1400QD installed 4,5,6 EL141LP PS1400QD one-lamp operation installed 4,5,6 AC Input Type Volts Amps Watts PS300QD 120/277.29 2.5 PSQ500QD 120/277.29 2.5 PS600QD 120/277.29 3.0 PS1400QD 120/277.29 3.5 1 Luminaire rating based on initial output of one 32W, T8 lamp. 2 Self-diagnostics (PSSD) module ships separately. See PSSD spec sheet for details. Not available on PS300QD. 3 Not available with Quick Disconnect wire harness. See below for housing dimensions. 4 To order a factory-installed battery pack, add suffix to fluorescent fixture catalog number. 5 Add DW to factory installed suffix to receive as wet or damp location listed, depending on the fixture. Applies to EL, EL5, EL6, EL14. Example: EL14 DW. 6 Add SD to suffix to receive self-diagnostics version. Example: EL5SD. Applies to EL5, EL6 and EL14. 6 Do not use with PSSD self-diagnostics module. PS300QD/PSQ500QD/PS600QD/PS1400QD Cross section end view 2-1/4 (56) 1-1/8 (44) Length: 13.8 (351) PS1400QD Length: 9.5 (241) all others Width: 2.19 (59.5) Height: 1.18 (29.9) Shipping weight PS300QD: 1.0 lbs. (0. 45 kgs.) PS500QD: 1.0 lbs (0.45 kgs.) PS600QD: 1.5 lbs (0.68 kgs.) PS1400QD: 2.0 lbs (0.9 kgs.) Accessories PSSD ELA TSPLP ELA TSPLP SD ELA PSTS ELA PSMK ELA PSMKSD ELA PSDMT ELA PSPRSB (Order Separately) Field installable self-diagnostic modules for PSQ500 DW, PSQ500QD, PS600 DW, PS600QD, PS1400 DW or PS1400QD Remote or replacement test switch/pilot light and mounting plate PS300, PS300QD, PSQ500, PSQ500QD, PS600, PS600QD, PS1400 and PS1400QD. Remote or replacement test switch/pilot light and mounting plate for self-diagnostics PSQ500SD, PSQ500QDSD, PS600SD, PS600QDSD, PS1400SD and PS1400QDSD Double-pole, single-throw test switch (no pilot light) External mounting kit External mounting kit for self-diagnostics module External mounting tray Field-installable interface for enhanced compatibility with lamp EOL (end of life) protected ballasts. For use with PSQ500, PS600 and PSI400 with quick disconnect (QD) and damp/wet (DW) 7 PS300 DW / PSQ500 DW / PS600 DW / PS1400 DW Cross section end view Length: 13.8 (351) PS1400 DW Length: 9.5 (241) all others Width: 2.5 (63.5) Height: 1.675 (41) 1-5/8 (41) Shipping weight PS300DW: 1.4 lbs. (0. 6 kgs.) PS500DW: 1.0 lbs (0.45 kgs.) PS600DW: 1.8 lbs (0.8 kgs.) 2-1/2 PS1400DW: 4.0 lbs (2.3 kgs.) (64) E14

Fluorescent Battery Packs, Downlighting Fluorescent Fixtures Factory- or field-installed on fluorescent downlighting fixtures to operate lamps at an initial light output of 20% to 85% of full lumen rating, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. Sealed, maintenance-free, high-temperature nickel-cadmium batteries. Housing is permanently sealed steel enclosure. UL Listed. Damp location listing available. Power Sentry Battery Packs PSDL1 operates one two-pin 18W or 26W quad-tube compact fluorescent lamp. PSDL1 2LP operates 2 two-pin (13-26W) quad-tube fluorescent lamps. PSDL2 operates one two-pin 7W, 9W or 13W quadtube compact fluorescent lamp. PSDL3 operates one or two four-pin twin-tube (9-13W), tripletube (18-42W*), quad-tube (13-26W) or 2D compact fluorescent lamp(s). *42W triple-tube is one lamp only. Example: PSDL3 SD PSDL1 PSDL2 PSDL3 Bi-pin 18-26W quad-tube lamps Bi-pin 7-13W twin-tube or quad-tube lamps Four-pin 9-42W quad-tube or triple-tube lamps SD Self-diagnostics 1 DL Damp location listed 0-50 C (32-122 F) 1 2LP Operates (2) two-pin quad-tube lamps (PSDL1) 2 EL ELR Factory installation 3 PSDL1/PSDL2/PSDL3 installed, compact fluorescent PSDL1/PSDL2/PSDL3 installed, compact fluorescent with remote pilot light/test switch AC Input Type Volts Amps Watts PSDL1 120.275 3.5 277.255 3.5 PSDL2 120.275 3.5 277.255 3.5 PSDL3 120.27 3.3 277.25 3.2 Accessories ELA TSPLP ELA PSTS ELA PSDMT ELA RTS3 (Order Separately) Remote or replacement test switch/mounting plate for PSDL3 Double-pole, single-throw test switch (no pilot light) External mounting tray (PSDL1, PSDL2, PSDL3) Remote test switch and pilot light for PSDL1 2LP 1 Available on PSDL3. Self-diagnostics (PSSD) module ships separately. See PSSD spec sheet for details. 2 Must specify PSDL1 2LP for two-lamp version. The PSDL3 product may be wired for a 2-lamp operation as a standard feature, see wiring diagrams. 2LP option does not need to be specified for the PSDL3. 3 To order a factory-installed battery pack, add suffix to fluorescent downlighting fixture catalog number. PSDL1/PSDL2/PSDL3 will be determined automatically based on ballast and lamp type. Add 2LP (example: EL2LP) to suffix to specify 2-lamp operation for all 4-pin or 2-pin quad lamps. (Available for Gotham downlighting and Lithonia downlighting.) PSDL1 and PSDL2 Cross section end view PSDL3 Cross section end view PSDL1 2LP Cross section end view 2-3/8 (60) Length: 10-5/8 (270) Shipping weight: 2.14 lbs. (.9 kgs.) 1-1/2 (38) 3-1/4 (81) Length: 17-1/8 (435) Shipping weight: 5.0 lbs. (2.3 kgs.) 1-3/4 (43) 2-2/5 (60) Length: 12 (304) Shipping weight: 3.0 lbs. (1.4 kgs.) 1-1/2 (38) E15

AC Power Systems power systems EAC IST EAC ISS Automatic standby AC power systems for incandescent and fluorescent lighting loads that provide full light output for 90 minutes of operation. Microprocessor-controlled PWM inverter with IGBT technology allows for universal compatibility. RS232 interface option allows communication with system from remote computer. Low voltage disconnect, short circuit protection, current limiting and brown-out protection. EAC IST: One compact self-contained cabinet. 12-hour battery recharge. Input circuit breaker. Normally on and off output circuit breakers. 20-character display with touch pad (4x4) controls, functions and data logging. Programmable self-diagnostic testing for 5 minutes monthly and 90 minutes annually is standard. 20 millisecond transfer time. EAC ISS: Stackable, modular cabinet design enabling versatile installation. Systems 4KVA and below are self-contained. Larger systems require external, stackable battery cabinets. digital meter panel displays input/output voltage, battery voltage and output current. 24-hour battery recharge standard. 50 millisecond transfer time. UL 924 Listed 90 minutes of operation. Example: EAC LC IST 1350 120/120 OTA EAC Emergency AC power system 1 Only available on the 750 VA. 2 Not available with the RS232. Battery type Lead-calcium IST System type Interruptible VA rating 750 1350 Voltage Input/Output 120/120 277/277 None Battery 2HR 2-hour run time 4HR 4-hour run time 1 Input/Output OTA Output trip alarm Miscellaneous Modem External modem for RS232 3WS External 3-way switch RMP Remote meter panel 2 FSP Factory start-up program RS232 Diagnostic interface DFC Form "C" contact DBR Dimmer bypass relay Example: EAC LC ISS 1500 120/120 OCB EAC Emergency AC power system Battery type Lead-calcium LC20 Lead-calcium battery. 20-year life 1 Systems 5000VA (5KVA) or larger require external battery cabinets. 2 Consult factory for other voltages. 3 20-amp, normally on unless otherwise specified. ISS System type Interruptible VA rating 1 1500 2250 3000 3750 5000 6000 8000 10000 12500 16700 Voltage 2 Input/Output 120/120 277/277 277/120 120/120-277 277/120-277 None Battery 12HR 12-hour battery recharge Electronic TD Time delay (15 minute) Input/Output OCB Output circuit breaker (specify quantity and amps) 3 OTA Output trip alarm Miscellaneous FSP Factory start-up program RMP Remote panel meter MBYP Maintenance bypass switch RS232 Diagnostic interface DFC Form "C" contact E16