SOLID PLUS HEAT

Similar documents
Flexible Heaters. of Silicone Rubber & Kapton

Mercury RV Water Heaters. Duoetto. HCE-10 Dual Voltage 12VDC/240VAC. P.O. Box 777, Leichhardt, NSW 2040

A-MIP 200 Installation and Operating Manual

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Battery Interconnects

Contents. Desiccators. Ice Pan. Carboys. Flask Supports VDR-20/20U/20G/20UG, VDR-25/25U/25G/25UG, VDR-30/30U/30G/30UG

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

CONDENSATE MANAGEMENT SYSTEMS

A-MIP 210 Installation and user guide

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

VA G 052 S

Imperial Electric Fires

ACCESS THE WORLD OF KNOX Product Catalog

Instructions for Installation and Use

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

1592P01. for liquids in piping DN

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Heat Pump / Air Conditioner

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Wall Mount Electric Fireplace

PARTS AND SERVICE MANUAL FOR THE 23 COMPACT FIREPLACE

DC-1000 DECAL WORLD KIT. Part # Description Qty Part # Description Qty DECAL KIT

Type 300 Series Bench Electrode Stabilization Ovens

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

DESIGN & TECHNICAL MANUAL

M7100 Pressure Transducer

A-MIP 100 Installation and Operating Manual

JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY MODEL : CHEETAH DC2000 FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL:

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

3 963/963E Benchtop Air Ionizer Instructions

4545 E Baseline Rd Phoenix AZ Phone: (602) Fax: (602) MODEL MP42B/MODEL MP42W Owners Manual

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Ultra-Thin Flexible Heaters

CRP-40 CRF-50 CR-50 / CR-50 CHROME CR-65 / CR-65 CHROME CR-80 / CR-80 CHROME CR-110 / CR-110 CHROME CR-140 / CR-140 CHROME

14 Upright Vacuum with HEPA Filter & Dual Power

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

CCS-100. Installation Manual

Premium 8 Zone Wireless Alarm Kit

Digital Room Thermostat

Coil Heaters, Mini Coil Heaters, Formable/Flexible Tubular Heaters

Centro-Matic Automated Lubrication Systems System Controls

WARRANTY LED ECO PANEL.

System 800 Addressable Fire Detection & Alarm System

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

D O M E S T I C LED. Lighting C O M M E R C I A L

DISPLAY ALARM SYSTEMS

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

CONDENSATE MANAGEMENT SYSTEMS

PVL1300 INSTRUCTIONS FOR USE

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Addendum for STI-6406 with Dual Access Control

curv-infrared.com The Smarter Way To Heat Your Home Revolutionary infrared heating

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

ENGINE COOLING 14-1 CONTENTS THERMOSTAT... 3 SERVICE SPECIFICATIONS... 2 LUBRICANT... 2 WATER PUMP... 5 ON-VEHICLE SERVICE... 2

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

CEILING FAN OWNER'S MANUAL

Yard Master Electric Series

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Bravo II. High Performance Multi-Purpose Speaker

PH1000T PH1500T PH2000T

NO VENTING REQUIRED 120V AC;

Machine Protection Door

OWNER S MANUAL 2018 EdenPURE I-5527 BR11756R-1

Fan speed controller Type Saginomiya XGE

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

FSW300 Series Flow Switch

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Rapid Entry System KNOX BOX INFORMATION PACKET. Exeter Township Fire Department Office of Fire Codes

LED RETROFIT CONVERSION KITS

Tempest TP420/180 Electric Pressure Washer

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

BF5000NT BF5000 EF2604 SF2603 DF2603

Transcription:

SOLID PLUS HEAT WWW.ROTAID.COM

PRODUCT SHEET The Rotaid Solid Plus Heat is a highly robust and durable AED wall cabinet that ensures a recognizable, solid and sustainable storage of your AED device in any environment. The characteristic round shape and design make it easy to be found and just a quick twist is needed to gain full access to the AED. The cover comes with AED logos and directive arrows to leave no room for interpretation. The cabinet can be opened in just a few seconds by an intuitive twist that removes the whole cover. The responder has full access to the AED that hangs via adjustable brackets for a quick and easy grab. The cover is attached to the back plate via a belt and needs no further attention after opening. A stainless steel hook, attached to the bottom of the cabinet, can hold a seal, tag or other appliance. The cover, equipped with recesses for an optimal grip and directive arrows, is made from 100% Polycarbonate. With a thickness of 5 millimetres it offers a solid protection and ensures a high grade of water- and dust resistance. The cover is fitted with UV filters to ensure long lasting transparency. Appearance decay, rust and accumulation of residue are excluded. The tailor made heating system ensures that the AED remains within its operational temperature range during frost. 8 LED lights make sure the cabinet can be found quickly in the dark. The whole system operates fully automatic and comes with an easy installation. All the materials are tested in the outdoors and provide a long lasting protection of both AED and cabinet. The cabinet is protected by an audible alarm system. LOW POWER CONSUMPTION OPERATIONAL AT TEMPERATURES AS LOW AS -20 C FULLY AUTOMATIC OPERATION LED LIGHTING

TECHNICAL DETAILS Brackets Led lights Control unit Heating device Stainless steel hook Holder for cover Dimensions Length 48 cm Width 48 cm Depth 18 cm Weight 6,7 kg Length 18,9 Width 18,9 Depth 7,1 Weight 14,7 lbs Packed individually by box, fastening materials included. www.rotaid.com

SPEC SHEET APPLICATION: For outdoor usage. DIMENSIONS Lenght 48 cm / 18,90 Width 48 cm / 18,90 Depth 18 cm / 7,1 Weight 6,7 kg /14,77 lb BACKPLATE 100% recycled HDPE (high-density polyethylene), 3 individual plates, fringe pattern finish. Rubber gasket ensures protection for dust and water. Pre-drilled mounting holes on top of back plate to house 2 DIN 912 8.8 EV M6x80 bolts (included) for optimal placement of the defibrillator.912 8.8 EV M 6 x 80). Solid steel hook on the bottom to install tamper seal, instructions or other accessories. 4 recessed mounting positions for firm fixation. 4 DIN 7981 A2 5,5 x 60mm screws and 4 DIN 9021 A2 M6x18x1,6 mm rings are included for installation on all walls.es. COVER 100% recycled Polycarbonate, 5 mm thick, fully transparent, fitted with UV filters for long-lasting transparency and UV blocking. A nylon belt is attached to the cover and connected to the back plate. The nylon belt is 15,75 inches long and 2 inches thick and is fitted with brass rings. 4 directive arrows provide guidance for opening the device. 6 indents provide grip for quick and solid opening. Available colors : green, yellow, red ALARM SYSTEM 90dB audible system, triggered by coin sized low power magnet in the cover, has an ABS housing and is pre-installed and fixated to the back plate. The alarm unit is powered by 2 AAA batteries. On top of alarm is a reset button to pause the alarm system if required. PACKAGING White box, FEFCO 0201, that meets FSC requirements. Box size 50 x 50 x 25 centimeters / 19,7 x 19,7 x 9,8 inches. COMPATIBLE WITH: All AED brands and types Check your AED on www.rotaid.com/outdoor-aed-cabinet#specifications One cabinet per box.

PTC AED CABINET HEATER The ROTAID - PTC AED cabinet heater is a self-limiting, heater with a build in controller based on 24V using a 230/110Volt transformer for safe usage and easy connection. This heater is based on a robust heater technology with a proven track record from many years in automotive applications. The heating circuit is not only relying on one continuous circuit. The heater consists of several hundred parallel PTC paste heating elements that ensure long lasting performance even if the circuits are locally damaged for some reason. POSITIVE TEMPERATURE CONTROL Power (Relative to 20 C) 2,5 2 1,5 1 0,5 0-40 -20 0 20 40 60 80 Temperature ( C) PTC (Positive Temperature Control) refers to the characteristic of the unique PTC paste used to generate the heat in the ROTAID PTC AED cabinet heater. The resistance in the heat generating paste will increase with temperature to such an extent that it is limiting the power efficiently above 30 C. This means that the heater will give more power when needed at low temperatures and less power as the temperature increases. This feature of the PTC paste adds an extra safety to the product that eliminates the risk of overheating. It still requires a temperature controller to give the needed heat and temperature into the AED cabinet. The nature of the PTC heating elements will give the heater slightly different characteristics than a conventional fixed wattage heater. The start power will be higher but will fall quite quickly to some point along the power curve. The final value depends on the surface temperature as well as the temperature measured in the control unit that is directly placed on the left bottom corner of the heating element. This controller regulates the power supply by switching on and off depending on its measurement. For easy installation the heater is equipped with an adhesive backside for easy installation in the AED cabinet. Additional holes are placed for additional fixation of the heating element to the backside of the AED cabinet. Rotaid AED cabinets www.rotaid.com

TECHNICAL SPECIFICATIONS Max. element temp. C, ( F) Min. element temp. C, ( F) Resistance tolerance Rated voltage Wattage Approvals/standards Other Self adhesive backside Connection wire Thermostat controller 70 (158) -50 (-58) ± 20% 230 65 @ 20 C surface NEMKO-CE (IEC 60335-1) Possible substrates: PET Yes 3 meters Yes THERMOSTATIC CONTROLLER FUNCTION >10 C 10-7 C 7-2 C < 2 C Off Max 50 % on time with increasing power 5% every 10 seconds Max 100 % on time with increasing power 5% every 10 seconds 100 % power on. TRANSFORMER 24VDC Power supply Input Cable length Output Max. output current Connection Cable length DC24V - 5000mA AC 100 ~240V 50/60Hz 1.2 mtr. DC 24 V± 5% 5000mA 120W. DC -straight connector 1.8 mtr. LIGHT 8 LED - 2 Watt Heater operational / Constantly light ON Heater failure / NO light Rotaid AED cabinets www.rotaid.com