SVC Manual(Exploded View)

Similar documents
SVC Manual(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems Wall-mounted, Multizone Heat Pump

J SERIES DUCTLESS SPLIT SYSTEMS

Ductless Split Systems Ceiling Cassette Heat Pumps

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

SERVICE MANUAL MODEL: LF300CP(LP-C303R20) LF480CE(LP-C483TA0)

Inverter Single (50Hz/R410A) 5RMA2-01B(5RMA2-01A)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems Concealed Duct Heat Pumps

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Unifit. Cool (03/07) Thru-the-Wall Series Service and Parts Manual

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Multi V Air Conditioner SVC MANUAL(Exploded View)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

DESIGN & TECHNICAL MANUAL

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Multi V Air Conditioner SVC MANUAL(Exploded View)

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Thru-the-Wall Series

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DESIGN & TECHNICAL MANUAL

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

2017 / 2018 RESIDENTIAL AIR CONDITIONERS

Samsung 360 Cassette, Single Zone, Split System

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

(Non-Inverter & Inverter) R410A

Universal Air Conditioner SVC MANUAL(Exploded View)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

DESIGN & TECHNICAL MANUAL

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Ducted inverter reverse cycle air conditioning

Multi V Air Conditioner SVC MANUAL(Exploded View)

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

PTAC Type (60Hz/R410A) 6RWU0-03A

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

Room Air Conditioner Service and Parts Manual

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications

RESIDENTIAL AIR CONDITIONERS 2017 RESIDENTIAL AIR CONDITIONERS

Geniuses at work. Residential Mini Splits

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Air Conditioners. Summer

Submittal Data Sheet

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

CASSETTE type INVERTER MULTI AIR CONDITIONER

Just feel well. 2017/2018 Air conditioning

LG Packaged Terminal Air conditioner/heat Pump SVC MANUAL(Exploded View)

Room Air Conditioner Service and Parts Manual

Multi Type Room Air Conditioner

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS


SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

LV Series. SEER 15+ Concealed Built in Heat Pump

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Transcription:

SVC Manual(Exploded View) Model : M18YJ M18CJ M24CJ FAC P/no : 960-920-01

Product Specifications System 18k 18k 24k System M18YJ M18CJ M24CJ FAC Model Name Outdoor Unit MR18Y3J MR18C3J MR24C3J Indoor Unit MW18Y3J MW18C3J MW24C3J Cooling Capacity kw 0.900 ~ 5.200 ~ 6.000 0.900 ~ 5.200 ~ 6.000 0.900 ~ 6.443~ 8.644 Btu/h. 3,070 ~ 17,000 ~ 20,473 3,070 ~ 17,000 ~ 20,473 3,070 ~22,000~ 29,515 Heating Capacity kw 0.900 ~ 6.300 ~ 9.000 - - Btu/h. 3,070 ~ 20,200 ~ 30,709 - - Power Input Cooling W 1417/ 1680 1417 2040 Running Current Cooling A 6.3/7.3 6.3 9 Starting Current Cooling A 6.3/7.3 6.3 9 Cooling COP - 3.52 3.52 3.16 EER - 12.0 12.0 10.8 SEER - 18.0 18.0 20.0 HSPF 9.7 - - Power Supply Ø/ V / Hz 1/208-230/60 1/208-230/60 1/208-230/60 Power Factor % 97 97 98 Air Flow Rate Indoor (QUIET, LOW, MED, HIGH) m 3 /min(cfm) 8.5(300)/11(389)/14.5(512)/17.0(600) 8.5(300)/11(389)/14.5(512)/17.0(600) 8.5(300)/11(389)/14.5(512)/17.0(600) Outdoor,Max m 3 /min(cfm) 50(1,766) 50(1,766) 60(2,119) Moisture Removal l/h. 2 2 2.6 Sound Level Indoor,H/M/L/Sleep db(a)±3 45 / 40 / 35 / 29 45 / 40 / 35 / 29 46 / 40 / 35 / 29 Outdoor,Max db(a)±3 53 53 54 Refrigerant & Charge (at 7.5 m/24.6ft) g(oz) R410A, 1,350(47.6) R410A, 1,350(47.6) R410A, 1,800(63.5) Additional Refrigerant charge g/m(oz/ft) 20(0.22) 20(0.22) 35(0.38) Type Twin Rotary Twin Rotary Twin Rotary Model GKT141MB GKT141MB GJT240MBA Compressor Motor Type Brushless DC Motor Brushless DC Motor Brushless DC Motor Oil Type PVE(FVC68D) PVE(FVC68D) PVE(FVC68D) Oil Charge cc 470 470 900 O.L.P. name - - - Fan(Indoor) Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Fan(Outdoor) Motor Output W 30 30 76.1 Type Propeller Propeller Propeller Motor Type BLDC BLDC BLDC Motor Output W 85 85 124 Circuit Breaker* A 20 20 25 Power Supply Cable No.*mm 2 (AWG) 3*2.0(14) 3*2.0(14) 3*2.5(12) Power and Transmission Cable No.*mm 2 (AWG) 4*1.0 (18) 4*1.0 (18) 4*1.0 (18) Piping Connections Liquid Side mm(in) 6.35(1/4) 6.35(1/4) 9.52(3/8) Gas Side mm(in) 12.7(1/2) 12.7(1/2) 15.88(5/8) Drain Hose(O.D / I.D.) mm(in) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) 21.5 / 16.0(0.85 / 0.63) Dimensions Indoor (W*H*D) mm 1,030*325*245 1,030*325*245 1,030*325*245 inch 40.6*12.8*9.64 40.6*12.8*9.64 40.6*12.8*9.64 Outdoor (W*H*D) mm 870*655*320 870*655*320 870*800*320 inch 34.3*25.8*12.6 34.3*25.8*12.6 34.3*31.5*12.6 Net Weight Indoor kg(lbs) 14.5(31.96) 14.5(31.96) 15(33.1) Outdoor kg(lbs) 44(97) 44(97) 55(121.25) Gross Weight Indoor kg(lbs) 18.2(40.1) 18.2(40.1) 18.7(41.23) Outdoor kg(lbs) 46(101.4) 46(101.4) 58.5(128.97) Operation Range Cooling(Outdoor) C( )DB -10(-18)*~48{14.0(0)*~118.4} -10(-18)*~48{14.0(0)*~118.4} -10(-18)*~48{14.0(0)*~118.4} Heating(Outdoor) C( )WB -20(-4)~24(75.2) - - Piping Length (Min/Max) m(ft) 3(9.84) / 20(65.6) 3(9.84) / 20(65.6) 3(9.84) / 30(98.4) Chargeless m(ft) 7.5(24.6) 7.5(24.6) 7.5(24.6) Max. Elevation Difference m(ft) 10(32.8) 10(32.8) 15(49.2) Tool Code(Chassis) Indoor + Outdoor SC + UE SC + UE SC + UE1+ Functions Temperature Control Allergy free filter - - - Plasma Filter - - - Prefilter(washable/anti-fungus) Auto Clean Natural Air Flow (Auto Wind) Steps, Fan/Cool/Heat 6/6/6 6/6 6/6 Airflow Direction Control(Up& Down) Auto Auto Auto Airflow Direction Control(Left & Right) Auto Auto Auto Remote Controller Type Wireless LCD Wireless LCD Wireless LCD Setting Temperature Cooling 18 ~30 18 ~30 18 ~30 Range Heating 16 ~30 - - Auto Operation - - - Auto Changeover Self-Diagnosis Timer 24h, On/off 24h, On/off 24h, On/off Sleep Operation Soft Dry Operation Restart Delay(minute) 3 3 3 Deice Control(Defrost) - - Hot Start - - Surge Cool Surge Low Ambient Operation Special Function Water Level Sensor Water Level Sensor Water Level Sensor Wind Baffle kit Wind Baffle kit Wind Baffle kit Note: O : Applied, - : No relation * For circuit breaker rating, please conform to local standards wherever necessary. The specification may be subject to change without notice for purpose of improvement. - 2 -

Piping Diagrams Model : M18YJ Indoor Unit Outdoor Unit Liquid Side Th2 2-Way Valve EEV Th1 Th4 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th7 Th3 Th6 Gas Side 3-Way Valve Accumulator Reversing Valve Compressor Th5 Cooling Heating LOC. Description PCB Connector Th1 Th2 Thermistor for suction air temperature Thermistor for evaporator inlet temperature CN-TH1(Indoor) Th3 Thermistor for evaporator outlet temperature CN-TH2(Indoor) Th4 Thermistor for evaporator middle temperature CN-TH3(Indoor) Th5 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR) Th6 EEV : Electronic Thermistor Expansion for condensing Valve temperature Th7 Thermistor for outdoor air temperature CN-TH1(OUTDOOR) - 3 -

Model : M18CJ M24CJ Indoor Unit Outdoor Unit Liquid Side Th2 2-Way Valve EEV Th1 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th5 Th4 Gas Side 3-Way Valve Accumulator Compressor Th3 Cooling Heating LOC. Description PCB Connector Th1 Thermistor for suction air temperature CN-TH1(Indoor) Th2 Thermistor for evaporator middle temperature CN-TH3(Indoor) Th3 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR) Th4 Th5 Thermistor for condensing temperature Thermistor for outdoor air temperature CN-TH1(OUTDOOR) EEV : Electronic Expansion Valve - 4 -

Wiring Diagrams Indoor Unit Model : MW18Y3J CN-U/D CN-L/R CN-DISP3 CN-DISP1 CN-TH1 CN- TH2 CN-TH3 CN-CN-REMO CN-MOTOR1 CN-LINK - 5 -

Indoor Unit Model : MW18C3J MW24C3J CN-U/D CN-L/R CN-DISP3 CN-DISP1 CN-TH1 CN- TH2 CN-TH3 CN-CN-REMO CN-MOTOR1-6 -

Outdoor Unit Model : MR18Y3J CN-U(S) CN-V(R) CN-W(C) CN-FAN(DC) CN-TH1 CN-4WAY CN-EEV1 CN-TH2 CN-COM CN-COIL2 CN-COIL - 7 -

Outdoor Unit Model: MR18C3J CN-U(S) CN-V(R) CN-W(C) CN-FAN(DC) CN-TH1 CN-EEV1 CN-TH2 CN-COM CN-COIL2 CN-COIL1-8 -

Outdoor Unit Model : MR24C3J CN-COM CN-EEV1 CN-LGMV CN-CENTRAL AC-L AC-N CN-MOTOR1 CN-PFC-OUT CN-TH3 CN-TH2 CN-PFC-IN - 9 -

Exploded View Indoor Unit Model : MW18Y3J 135316 152301 268711F 135511 131111 131410 135303 149303 733010 267110 342800 359011 135500C 149304 135090 354212 W50400 352150 354210 346810 249951 135500A 146811B 35211B 268711E 268711C 147582 135500B 145200A 263230B W6640 145200B 146811A 263230C 263230A 135311 147581 263230A 263230B 263230C LOC Description Thermistor for suction air temperature Thermistor for evaporator inlet temperature Thermistor for evaporator outlet temperature Thermistor for evaporator middle temperature - 10 -

Model: MW18Y3J MW18Y3J Loc No. P/N_FRD Description Qty 131410 67601001 Chassis Assembly 1 149303 67602705 Holder,Tubing 1 346810 67603329 Motor,DC 1 135500A 67601508 Cover 1 359011 67602107 Fan Assembly,Cross Flow 1 342800 67606700 Bearing 1 354212 67602020 Evaporator Assy Final 1 354210 67602012 Evaporator Assembly,First 1 35211B 67606012 Tube Assy Tubing 1 149304 67602702 Holder,Evaporator 1 249951 67600937 Case Assy Control(Indoor) 1 W6640 67601404 Connector,Terminal Block 1 268711C 67603944 PCB Assy Main 1 263230C 67604833 Thermistor Assy NTC 1 263230B 67604801 Thermistor Assembly 1 263230A 67604816 Thermistor Assembly,NTC 1 135311 67602501 Grille Assembly,Discharge(Indoor) 1 147581 67603202 Louver,Horizontal 1 147582 67603205 Louver,Vertical 12 145200A 67603001 Link 1 145200B 67603000 Link 1 146811B 67603320 Motor Assembly,DC,Stepping 1 W50400 67601700 Damper 2 135316 67602529 Grille Assy Front(Indoor) 1 135303 67602530 Grille Assy Inlet 1 152301 67602210 Filter,Deodorizing 2 268711F 67603924 PCB Assembly,Sub 1 135511 67601601 Cover Assembly,Control(Indoor) 1 135090 67601801 Decor Assembly 1 135500C 67601507 Cover 1 733010 67604001 Plate Assembly,Installation 1 352150 67602806 Hose Assembly,Drain 1 135511 67601601 Cover 1 268711E 67603945 PCB Assy Option 1 146811A 67603317 Motor Assembly,DC,Stepping 1 267110 67604307 Remote Controller Assembly 1 135500B 67601508 Cover 1-11 -

Indoor Unit Model : MW18C3J, MW24C3J 135316 152301 268711F 135511 131111 131410 135303 149303 733010 359011 267110 342800 135500C 149304 135090 354212 W50400 352150 354210 346810 249951 135500A 146811B 35211B 268711E 268711C 147582 135500B 145200A 263230A W6640 145200B 146811A 263230B 135311 147581 263230A 263230B LOC Description Thermistor for suction air temperature Thermistor for evaporator middle temperature - 12 -

Model: MW18C3J MW18C3J Loc No. P/N_FRD Description Qty 131410 67601001 Chassis Assembly 1 149303 67602705 Holder,Tubing 1 346810 67603329 Motor,DC 1 135500A 67601508 Cover 1 359011 67602107 Fan Assembly,Cross Flow 1 342800 67606700 Bearing 1 354212 67602020 Evaporator Assembly,Final 1 354210 67602012 Evaporator Assembly,First 1 35211B 67606012 Tube Assembly,Tubing 1 149304 67602702 Holder,Evaporator 1 249951 67600939 Case Assy Control(Indoor) 1 W6640 67601404 Connector Terminal Block 1 268711C 67603947 PCB Assy Main 1 263230B 67604808 Thermistor Assembly,NTC 1 263230A 67604801 Thermistor Assembly 1 135311 67602501 Grille Assembly,Discharge(Indoor) 1 147581 67603202 Louver,Horizontal 1 147582 67603205 Louver,Vertical 12 145200A 67603001 Link 1 145200B 67603000 Link 1 146811B 67603320 Motor Assembly,DC,Stepping 1 W50400 67601700 Damper 2 135316 67602531 Grille Assy Front(Indoor) 1 135313 67602530 Grille Assembly,Inlet 1 152301 67602210 Filter,Deodorizing 2 268711F 67603924 PCB Assembly,Sub 1 135511 67601601 Cover Assembly,Control(Indoor) 1 135090 67601801 Decor Assembly 1 135500C 67601507 Cover 1 733010 67604001 Plate Assembly,Installation 1 352150 67602806 Hose Assembly,Drain 1 131111 67600923 Case Assembly,Indoor 1 268711E 67603948 PCB Assy Option 1 146811A 67603317 Motor Assembly,DC,Stepping 1 267110 67604309 Remote Controller Assy 1 135500B 67601511 Cover 1-13 -

Model: MW24C3J MW24C3J Loc No. P/N_FRD Description Qty 131410 67601001 Chassis Assembly 1 149303 67602705 Holder,Tubing 1 346810 67603329 Motor,DC 1 135500A 67601508 Cover 1 359011 67602107 Fan Assembly,Cross Flow 1 342800 67606700 Bearing 1 354212 67602005 Evaporator Assembly,Final 1 354210 67602012 Evaporator Assembly,First 1 35211B 67605001 Tube Assembly,Tubing 1 149304 67602702 Holder,Evaporator 1 249951 67600939 Case Assembly,Control(Indoor) 1 W6640 67601404 Connector,Terminal Block 1 268711C 67603947 PCB Assembly,Main 1 263230B 67604808 Thermistor Assembly,NTC 1 263230A 67604801 Thermistor Assembly 1 135311 67602501 Grille Assembly,Discharge(Indoor) 1 147581 67603202 Louver,Horizontal 1 147582 67603205 Louver,Vertical 12 145200A 67603001 Link 1 145200B 67603000 Link 1 146811B 67603320 Motor Assembly,DC,Stepping 1 W50400 67601700 Damper 2 135316 67602531 Grille Assembly,Front(Indoor) 1 135313 67602530 Grille Assembly,Inlet 1 152301 67602210 Filter,Deodorizing 2 268711F 67603924 PCB Assembly,Sub 1 135511 67601601 Cover Assembly,Control(Indoor) 1 135090 67601801 Decor Assembly 1 135500C 67601507 Cover 1 733010 67604001 Plate Assembly,Installation 1 352150 67602806 Hose Assembly,Drain 1 131111 67600923 Case Assembly,Indoor 1 268711E 67603949 PCB Assy Option 1 146811A 67603317 Motor Assembly,DC,Stepping 1 267110 67604309 Remote Controller Assembly 1 135500B 67601511 Cover 1-14 -

Indoor Unit Model : MR18Y3J 263230A 263230B LOC Description Thermistor for suction air temperature Thermistor for condense middle temperature Thermistor for discharge pipe temperature - 15 -

Model : MR18Y3J MR18Y3J Loc No. P/N_FRD Description Qty 437211 67603848 Panel Assembly, Front(Outdoor) 1 237202 67603838 Panel Front 1 435301 67602524 Grille Discharge 1 349480 67603601 Orifice 1 430410 67600604 Base Assy Outdoor 1 152503 67603500 Nipple Drain 1 559010 67602116 Fan Propeller 1 546810 67603327 Motor Assy DC Outdoor 1 349600 67301801 Bracket Motor 1 435512 67601614 Cover Assy Top(Outdoor) 1 649950 67600938 Case Assy Control(Outdoor) 1 268711C 67603946 PCB Assy Main 1 552112 67605301 Tube Assy Conderser(In) 1 W6640 67601405 Connector Terminal Block 1 447910 67600306 Barrier Assy Outdoor 1 261704 67604902 Transformer Reactor 1 554160 67604202 Compressor Set 1 550140 67601702 Damper Compressor 3 W6631 67602606 Harness Single 1 437212 67603818 Panel Assy Rear(Outdoor) 1 435511B 67601608 Cover Assy Control(Outdoor) 1 135500 67601506 Cover 1 661400 67601103 Coil Expansion 1 552113 67605306 Tube Assy Conderser(Out) 1 552200 67606301 Valve Expansion Body 1 263230A 67604812 Thermistor Assy NTC 1 263230B 67604817 Thermistor Assy NTC 1 552116 67606108 Tube Assy Reverse 1 552202 67606403 Valve Reverse 1 561410 67601904 Drawing Assy 1 W49810 67604606 Supporter Assy 1 552203A 67606505 Valve Service 1 552203B 67606501 Valve Service 1 554031 67601301 Condenser Assy Bending 1-16 -

Outdoor Unit Model : MR18C3J 263230A 263230B LOC Description Thermistor for suction air temperature Thermistor for condense middle temperature Thermistor for discharge pipe temperature - 17 -

Model: MR18C3J MR18C3J Loc No. P/N_FRD Description Qty 437211 67603848 Panel Assembly, Front(Outdoor) 1 237202 67603838 Panel, Front 1 435301 67602524 Grille, Discharge 1 349480 67603601 Orifice 1 430410 67600604 Base Assembly, Outdoor 1 152503 67603500 Nipple, Drain 1 559010 67602116 Fan, Propeller 1 546810 67603327 Motor Assembly, DC, Outdoor 1 349600 67301801 Bracket, Motor 1 435512 67601614 Cover Assembly, Top(Outdoor) 1 649950 67600938 Case Assembly, Control(Outdoor) 1 268711C 67603946 PCB Assembly, Main 1 552112 67605301 Tube Assembly, Conderser(In) 1 W6640 67601405 Connector, Terminal Block 1 447910 67600306 Barrier Assembly, Outdoor 1 261704 67604902 Transformer, Reactor 1 554160 67604202 Compressor Set 1 550140 67601702 Damper, Compressor 3 W6631 67602606 Harness, Single 1 437212 67603818 Panel Assembly, Rear(Outdoor) 1 435511B 67601608 Cover Assembly, Control(Outdoor) 1 135500 67601506 Cover 1 661400 67601103 Coil,Expansion 1 552113 67605306 Tube Assembly, Conderser(Out) 1 552200 67606301 Valve, Expansion Body 1 263230A 67604812 Thermistor Assembly, NTC 1 263230B 67604817 Thermistor Assembly, NTC 1 552116 67606108 Tube Assembly, Reverse 1 552202 67606403 Valve, Reverse 1 W49810 67604606 Supporter Assembly 1 552203A 67606505 Valve, Service 1 552203B 67606501 Valve, Service 1 554031 67601301 Condenser Assembly, Bending 1-16 -

Outdoor Unit Model: MR24C3J 263230A 263230B LOC Description Thermistor for suction air temperature Thermistor for condense middle temperature Thermistor for discharge pipe temperature - 19 -

Outdoor Unit Model: MR24C3J MR24C3J Loc No. P/N_FRD Description Qty 430410 67600605 Base Assembly,Outdoor 1 554031 67601300 Condenser Assembly,Bending 1 352111B 67605400 Tube Assembly,Connector 1 554160 67601202 Compressor Set,Korea 1 552115 67606008 Tube Assembly,Manifold(Outdoor) 1 552113 67605303 Tube Assembly,Condenser(Out) 1 55211G 67605902 Tube Assembly,Expansion 1 W49810 67604606 Supporter Assembly 1 552203B 67606513 Valve,Service 1 552203A 67606507 Valve,Service 1 552200 67606302 Valve,Expansion Body 1 552117 67606205 Tube Assembly,Suction(Outdoor) 1 552116 67606106 Tube Assembly,Reverse 1 552202 67606403 Valve,Reverse 1 661400 67601101 Coil,Expansion 1 435511A 67601605 Cover Assembly,Control(Outdoor) 1 447910 67600302 Barrier Assembly,Outdoor 1 549610 67600707 Bracket Assembly,Motor 1 W4810 67600719 Bracket 1 546810 67603312 Motor Assembly,DC,Outdoor 1 559010 67602115 Fan,Propeller 1 137213A 67603828 Panel Assembly,Side 1 137213B 67603827 Panel Assembly,Side 1 435512 67601610 Cover Assembly,Top(Outdoor) 1 550140 67601701 Damper,Compressor 3 152503 67603500 Nipple,Drain 1 435300 67602518 Grille,Rear 1 437211 67603803 Panel Assembly,Front(Outdoor) 1 437210 67603810 Panel Assembly,Front(Sub) 1 435301 67602514 Grille,Discharge 1 349480 67603602 Orifice 1 435511B 67601608 Cover Assembly,Control(Outdoor) 1 135500 67601506 Cover 1 649950 67600940 Case Assy Control(Outdoor) 1 268711 67603950 PCB Assy 1 263230A 67604812 Thermistor Assembly,NTC 1 263230B 67604834 Thermistor Assy NTC 1 W6640 67601400 Connector,Terminal Block 1 W6631 67602606 Harness,Single 1-20 -

P/No. : MFL67501910