Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Similar documents
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

AVTI Multifunctional self - acting controller

Temperature controller for steam (PN 25) AVT / VGS - external thread

Automatic balancing valves ASV-PV (new generation) DN 32-50

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

60 C water temperature ensures thermal disinfection during hot water production

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

ThermoDual Domestic hot water charging system

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

TA-MATIC

HERZ Differential Pressure Control Valve 4002

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

HERZ Regulating valve 4002

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

30% Take lead on your project with an efficient system concept. lower energy.

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Thermostatic valves with radiator connection systems

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Multilux 4-Eclipse-Set

product overview ProControl

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

FHM-Cx Mixing Shunts for Floor Heating

Control valves for floor heating systems. Floor Heating Manifolds

Thermostatic valve bodies

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Mikrotherm. Manual Radiator Valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Akva Vita Instantaneous water heater

Technical paper Selection of district heating house stations

Thermostatic expansion valves for ammonia Type TEA

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Flush individual room control for floor heating systems

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Instructions for installation and use Akva Lux II VX substations 1. Contents

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Thermostatic valve bodies

Systems for central heating

Partner Valve/High Quality Ball Valve LENO MSV-S

FHM-Cx Mixing Shunts for Floor Heating

T. +44 (0) E.

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Brazed heat exchanger XB

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

ModuSat TP. Energy. Heat Interface Units

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

manifold, for radiators

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Radiator Trap Radiator Valve

ModuSat TP. Energy. Heat Interface Units

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

IMI Heimeier Kit Hydroca ble

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

TS RD 7761 RD, 7761 RD

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

Herz York Direct Heat Interface Unit

RA 2000 Series RA 15/6T & TB Conversion Valve

Design & Product Guide. Danfoss FlatStations.

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

RA15/6T & TB Conversion Valve

Three-way reversing valve

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Say heating. Say Herz. HERZ-Supply Engineering

Standard. thermostatic valve body without presetting

Technical Product Guide

Regulux. Radiator lockshield with drain-off facility. To be precise.

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

13-1. Temperature Regulator

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Valves, controls + systems Flow, pressure and temperature balancing

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

a Danfoss Platform for Flensburg Secondary Network

9. Cooling Water System

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Metering systems 0548EN April 2014

Transcription:

Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning, heating, domestic hot water). XB brazed plate heat exchangers are made with several differently sized heat exchange plates. The IHPT is flow-compensated temperature controller with p controller built in developed to control instantaneous heating of domestic hot water by means of heat exchanger. Innovative design enables simple, fast and reliable connection to heat exchanger and most important production of ultra compact and user friendly stations for heating of domestic hot water service. The capacity of controllers fully covers the needs of domestic hot water for flats, one family houses or dwellings and can be mounted to district heating network directly, to a block of heating systems or central located boiler system in a dwelling house. Typical system conditions District heating systems with varying supply temperature plus high and varying differential pressure and where a high comfort idle temperature is requested. Idle controller is integrated. Controllers have: - WRAS approval, - ETA VA approval, - DVGW approval. Main data: DN 15 k VS 2.4, 3.0 m 3 /h PN 16 Setting range: 45... 65 C (see Setting range section) Temperature: Circulation water 2... 120 o C Connections: - Union nut The controller is connected to primary heating system as well as cold water system. To avoid risk of leaking from one media to the other the controller is equipped with double sealing. Between both sealings there is a bore to the outside of the valve. In case of leakage from one sealing the media can escape through the bore. DH-SMT/SI VD.KV.A7.02 Danfoss 10/2014 1

Ordering IHPT Controller Example 1: Flow-compensated temperature controller with p controller built in (NO), DN 15, k VS 2.4, PN 16, setting range 45... 65 C, union nut connection Picture DN 15 k VS (m 3 /h) Setting range 3) Connection Code No. 2) ( C) 2.4 003L3813 45 65 Union nut 3.0 003L3815-1 IHPT DN 15 controller Code No: 003L3813 Option: - 1 Housing of sensor stuffing box Code No: 013U8102 Example 2: Flow-compensated temperature controller with p controller built in (NO), DN 15, k VS 2.4, PN 16, setting range 45... 65 C, union nut connection & brazed heat exchanger XB06 with 26 plates - 1 Combination DN 15 Code No: 003L3900 to heat exchanger 2) Controller is delivered with thermostatic actuator with standard sensor and M14 sensor stuffing box (housing of sensor stuffing box is not delivered, it is available as an accessory) 3) see Setting range section IHx Controllers, 90 version - Damped Picture Type DN IHPT 3) 15 k VS Setting range 4) Connection 2) Code No. (m 3 /h) ( C) 2,4 003L3875 45 65 Union nut 3,0 003L3877 For details see Selection guideline section 2) to heat exchanger 3) Controller is delivered with thermostatic actuator with standard sensor and M14 sensor stuffing box (housing of sensor stuffing box is not delivered, it is available as an accessory) 4) see Setting range section XB06 & IHPT Picture Type DN k VS (m 3 /h) Setting range 3) ( C) Heat exchanger type XB 06H-1-26 XB 06H-1-30 XB 06H-1-36 Combination Code No. 2) IHPT 15 2.4 003L3900 003L3901 003L3902 45 65 3.0 003L3903 003L3904 003L3905 Controller is delivered with standard sensor and R p ½ sensor stuffing box incl. housing of sensor stuffing box 2) Code number includes one IHPT and one heat exchanger 3) see Setting range section IHPT & XB06 (II) Picture Type DN k VS (m 3 /h) Setting range 3) ( C) Heat exchanger type XB 06H-1-16 XB 06H-1-26 Combination Code No. 2) IHPT 15 2.4 003L3920 45 65 3.0 003L3921 Controller is delivered with standard sensor and R p ½ sensor stuffing box incl. housing of sensor stuffing box 2) Code number includes one IHPT and two heat exchangers 3) see Setting range section Accessories Type designations Housing of sensor stuffing box Code No. 013U8102 Code includes housing and gasket of sensor stuffing box; R ½ M14 1 mm, rubber EPDM Ø 12,6 4 6 mm Ser vice kits Type designations Setting range Code No. ( C) for IHPT Service thermostat 40 60 003L3868 Thermostatic actuator with standard sensor 45 65 003L3833 For details see Installation positions section; sensor is delivered with M14 sensor stuffing box 2 VD.KV.A7.02 Danfoss 10/2014 DH-SMT/SI

Technical data * * Data for XB06 see relevant Data sheet Nominal diameter DN 15 k VS value of thermostatic controller (kvs,tc) 2.4 3.0 m 3 /h k VS value of built in p controller (k VS,DP ) 5.0 Controlled p on thermostatic controller ( ptc) bar 0.16 Min. flow rate on primary side (Q 1,min ) 70 100 Max. flow rate on primary side (Q 1,max ) 1000 1200 l/h Min. flow rate on secondary side (Q 2,min ) 120 Max. rec. flow rate on secondary side (Q 2,max ) 1400 4) Nominal pressure PN 16 3) Max. differential pressure on primary side 6.0 bar Max. rec. differential pressure on secondary side 1.0 Medium Circulation water / glycolic water up to 30% Domestic hot water (chlorine (cl) content max. 200 ppm) 2) Medium ph Min. 7, max. 10 3) Medium temperature 2... 120 Setting range 45 65 ºC Idle temperature T set 8 C Max. adm. temperature at sensor 120 Capillary tube length m 0.6 Materials Housings CuZn36Pb2As (CW 602N) Cone and diaphragm support MPPE (Noryl) Main spindle Stainless steel, mat. No. 1.4404 Diaphragm, O-rings EPDM Temperature sensor Copper, mat. No. 2.0090 Valid for primary side 2) Valid for secondary side 3) On primary and secondary side 4) at diff. pressure on secondary side (Δp 2 ) 1 bar Classification according to VDI 6003 Type Wash basin Showers 2) IHPT III III Tapping rate changing in steps of 6-12-6 l/min. 2) Tapping rate changing in steps of 9-12-9 l/min. Measured for constant supply temperature of 75 C and system differential pressure of 0.5 bar. The min. required differential pressure across primary side of the controller is calculated from the formula: Δp PRIM, min Q k PRIM,max VS,DP 2 Δp In graph pressure drop on secondary side in relation to the secondary flow can be seen. TC Secondary side * TC - thermostatic controller Quick suggestion: If the max. flow rate on primary side is below 1 m 3 /h (1000 l/h) always choose k VS = 2.4 m 3 /h and if it is higher then choose k VS = 3.0 m 3 /h. DH-SMT/SI VD.KV.A7.02 Danfoss 10/2014 3

Setting range Temperature setting depends on application parameters. Values given are approximate. Application scheme Functions Flow-compensated temperature controller with differential pressure controller built in (NO) Typical system conditions District heating systems with varying supply temperature plus high and varying differential pressure and where a high comfort idle temperature is requested. Idle control alternatives Idle controller is built in. IHPT QC TC DP Application principle 4 VD.KV.A7.02 Danfoss 10/2014 DH-SMT/SI

Sensor installation Temperature controller Controller must be mounted on cold side of heat exchanger (district heating outlet and domestic cold water inlet side). Best performance IHPT, Termix TPV controllers are delivered with standard sensor. Standard sensor The sensor must always be placed warmer than the controller. Temperature sensor Can be mounted on any direction. For best performance it is recommended to install the sensor facing up. Strainers installation IIt is strongly recommended to install strainers on both the cold water pipeline and the district heating supply line. Sizing Example Instantaneous domestic hot water production requires primary flow of 800 l/h. Minimum system differential pressure is 0.8 bar. Given data: Q PRIM, max = 0.8 m 3 /h (800 l/h) Δp syst, min = 0.8 bar (80 kpa) Δp exchanger = 0.1 bar (10 kpa) The total (available) pressure loss across the primary side of the controller is: Δp PRIM,A = Δp syst,min - Δp exchanger = 0.8-0.1 Δp PRIM,A = 0.7 bar (70 kpa) Possible pipe pressure losses in tubes, shut-off fittings, heatmeters, etc. are not included. Select controller acc. to technical data, page 3, with the smallest possible kvs value considering available flow ranges: k VS, TC = 2.4 m 3 /h The other relevant data for this controller are: k VS, DP = 5.0 m 3 /h Δp TC = 0.16 bar (16 kpa) The min. required differential pressure across primary side of the selected controller is calculated from the formula: Δp PRIM, min Q k PRIM,max VS,DP 2 Δp Δp PRIM,min = 0.19 bar (19 kpa) Δp PRIM,A > Δp PRIM,min 0.7 bar > 0.19 bar TC 2 0.8 5 0.16 Δp PRIM, MIN Δp TC Δp syst,min IHPT TC DP Δp exchanger QC DH-SMT/SI VD.KV.A7.02 Danfoss 10/2014 5

Design 1. Secondary side cone (QC) 2. Moving seat 3. Main body 4. O-ring 5. Differential pressure cone (DP) 6. Main spindle 7. Primary side cone (TC) 8. Stuffing box 9. Thermostat 10. Handle for temperature setting 11. Secondary side body 12. Circulation connection plug (3/8 ) 13. Temperature sensor 14. Differential pressure moving seat 15. Washer of sensor stuffing box 16. Gasket of sensor stuffing box 17. Sealing bolt of sensor stuffing box 18. Primary side body 19. Housing of sensor stuffing box Function The controller has three main functions that can be mounted in the controller based on application demands: QC Proportional flow controller TC Thermostatic controller DP Differential pressure controller TC DP QC To minimise the risk of calcium deposits on cold water side and sensitivity to high temperatures the controller is mounted on cold side of heat exchanger (district heating outlet and domestic cold water inlet side). In standard applications at standard conditions with Danfoss heat exchanger XB 06 primary return temperature is below 30 C. 6 VD.KV.A7.02 Danfoss 10/2014 DH-SMT/SI

Function (continuous) Flow-compensated temperature controller IHPT with integrated differential pressure controller Flow-compensated temperature controller IHPT with integrated differential pressure controller When tapping starts, cold water flows into secondary side of controller 1 passes the secondary side cone (QC) 2, leaves the controller 3 and enters the heat exchanger. The pressure drop generated on the orifice is transferred to the diaphragm 4 which transfers the force to the spring 12. This results in moving of the main spindle 5 to the right which opens the primary side cone 6. The opening results in primary flow entering into controller 7, passing integrated differential pressure controller (DP) 8, primary side cone (TC) 6 and leaving controller 9. The temperature sensor 10, mounted to the secondary hot water side is sensing the temperature. If the temperature is deviating from setting temperature the thermostatic element 13 will move (open/close) primary side cone 6 until desired temperature is reached. Not to influence on tapping flow from thermostatic adjustments the spring 12 is mounted between main spindle 5 and diaphragm which can be compressed when needed. When no load (no flow on secondary side) the controller mantains constant temperature in the heat exchanger few degrees below adjusted temperature (Idle temperature). The differential pressure controller 8 controls the pressure over control valve and therefore enables 100 % authority of the controller in all conditions. By rotating the handle for temperature setting 13 the temperature of tapping flow can be adjusted. Domestic hot water circulation 11 connections are placed directly on the controller and therefore minimize the costs for mounting and optimize space for the piping. DH-SMT/SI VD.KV.A7.02 Danfoss 10/2014 7

Settings Temperature setting Temperature setting is adjusted with handle for temperature setting. By turning it in (+) direction the setting is increased, by turning it in (-) direction the setting is decreased. Mounting specifics Connections to heat exchanger Union nut connection Second option is with union nuts to standard threaded heat exchanger connections (fig. which have distance between them 45 mm. In order to cover the tolerances of heat exchanger production special union nuts were developed which can tolerate dimensions of 45 ± 1,5 mm (Factory assembled). In this case standard fittings should be used on hot side of heat exchanger. Connections to pipes For connecting controller to station ¾ connections are used. Fig. 1 8 VD.KV.A7.02 Danfoss 10/2014 DH-SMT/SI

Dimensions DH-SMT/SI VD.KV.A7.02 Danfoss 10/2014 9

10 VD.KV.A7.02 Danfoss 10/2014 DH-SMT/SI

11 VD.KV.A7.02 Danfoss 10/2014 DH-SMT/SI

12 VD.KV.A7.02 Produced by Danfoss A/S 10/2014