Elements Headwall System (P2008A)

Similar documents
DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

SECTION ISOLATED POWER SYSTEMS

Tempo Procedure Carts. Storage Solutions for Healthcare

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SECTION (16140) - WIRING DEVICES

Chilled Water DOAS Fan Powered Terminal Units

Pipeline. Medical Gas Pipeline Products

Total Articulating Service Column - TASC 2000 Series

SECTION EXTERIOR LIGHTING

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Pipeline. Medical Gas Pipeline Products

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

DIVISION 10 SPECIALTIES

CADDY CORPORATION. Utility Distribution Systems

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

SECTION AIR DUCT ACCESSORIES

ADDENDUM NO. 3 March 19, 2018

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Palisade Collection. Product Guide. Key Selling Points 2. Statement of Line and Overall Dimensions 3. Product Details. Flop Sofa 4.

FIND OUT MODULARSERVICES.COM

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Stainless Steel Storage Cabinets

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

SECTION PACKAGED HEAT TRANSFER SYSTEM

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

15900 HVAC INSTRUMENTATION AND CONTROLS

A. Section Instrumentation and Control Devices for HVAC. B. Section Building Automation Systems(BAS) for HVAC

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION COMMERCIAL-KITCHEN HOODS

SECTION AUTOMATIC TRANSFER SWITCHES

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

DIVISION FINNED WATER-TUBE BOILERS

Fire Pump Specification

Instrument Cabinets. Stainless Steel IC Series. Dimensions: Features:

Freestanding Treatment Console Installation

CABINET PARTS For Models: 7GS2SHEXPQ03, 7GS2SHEXPL03 (White) (Stainless VCM) REFRIGERATOR

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

SECTION DUCTWORK

B. Section Identification for Fire Suppression Piping and Equipment.

WATER-TUBE POOL HEATERS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION NURSE CALL SYSTEM

CABINET PARTS. For Models: GD2SHAXNQ00, GD2SHAXNT00, GD2SHAXNB00, GD2SHAXNS00, GD2SHAXNL00 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

DIVISION FINNED WATER-TUBE BOILERS

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION AIR COILS

DIVISION FINNED WATER-TUBE BOILERS

REFRIGERANT PIPING SYSTEM

Revitalize Building Mechanical Systems (4619)

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT

SECTION AIR COILS

University of Rochester October 17, 2008 Brooks Landing Business Center

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

WATER-TUBE POOL HEATERS

TELETOM EQUIPMENT MANAGEMENT SYSTEMS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

FOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30,

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

CABINET PARTS. For Models: GS5SHAXNQ02, GS5SHAXNT02, GS5SHAXNB02, GS5SHAXNS02, GS5SHAXNL02 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

SECTION WET-PIPE SPRINKLER SYSTEMS

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

SECTION AUTOMATIC TRANSFER SWITCHES

Design and Construction Standards SECTION PLUMBING EQUIPMENT

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

CABINET PARTS REFRIGERATOR

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

EcoAisle Thermal Containment System

Transcription:

Figure 1. Elements Headwall System American Society of Mechanical Engineers 3 (ASME ) ASME B16.22: Wrought Copper and Copper Alloy Solder Joint Pressure Fittings American Standard Test Method 4 International (ASTM ) ASTM E90: Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements and ASTM E413: Classification for Rating Sound Transmission Compressed Gas Association (CGA 5 ) CGA G4.1: Cleaning Equipment for Oxygen Service and CGA V-5: Diameter Index Safety System (Non-Interchangeable Low Pressure Connections for Medical Gas Applications) National Fire Protection Association 6 (NFPA) NFPA 99: Heath Care Facilities and NFPA 70: National Electrical Code (NEC ) Underwriters Laboratories Inc. (UL) UL 1047: Isolated Power Systems Equipment PURPOSE The Elements Headwall System (P2008A) supplies a configurable modular headwall system that is designed with various widths and depths to allow the facility to customize its headwall construction in accordance with the specific needs of the individual patient environment and the facility architecture. Standards The Elements Headwall System meets all national, state, and local codes and these: American National Standards Institute 1 (ANSI )/Underwriters Laboratories 2 (UL) ANSI/UL 514A: Metallic Outlet Boxes Description The Elements Headwall System improves functionality in the patient hospital rooms and aids to create a comfortable environment for healing. Communication, electrical, and medical gas services are integrated in the system and are customized to meet the needs of the clinicians and patients in accordance with the facility preferences and requirements. WARNING: Do not install the in-wall product in positive- or negative-pressure rooms, fire or smoke rated walls, and/or load bearing walls. Injury or equipment damage could occur. 1. American National Standards Institute and ANSI are registered trademarks of American National Standards Institute. 2. Underwriters Laboratories Inc. is a registered trademark of Underwriters Laboratories Inc. 3. American Society of Mechanical Engineers and ASME are registered trademarks of The American Society of Mechanical Engineers. 4. American Society for Testing and Materials and ASTM are registered trademarks of American Society for Testing and Materials. 5. CGA is a registered trademark of Compressed Gas Association, Inc. 6. National Fire Protection Association, National Electrical Code, and NEC are registered trademarks of National Fire Protection Association, Inc. January 27, 2015 156515 REV 2 Page 1 of 6

The Elements Headwall System is designed to be configured into vertical zones through a specified arrangement of service panels and access panels. However, the system can be configured in various widths as single or double units. These zones are described as follows: Patient zone located in the center of the headwall system. Caregiver zone (clinical zones 1 and 2) usually arranged on both sides of the patient zone. Staff zone usually located closest to the room entrance. Family zone usually located farthest from the room entrance. The Elements Headwall System can be mounted on the finished wall surface or installed in the wall as part of the framed stud wall. Surface mounted depth is 4 1/2" (11.43 cm) from the finished wall. In-wall installation is available with 3 5/8" (9.21 cm) or 6" (15 cm) frame depth. Wall structure payload per vertical section is 1150 lbs (68 kg) maximum. The load capacity varies with the product configuration. The width of the headwall module will depend upon the service and access panel options selected for the system. The various widths allow the headwall to be configured to match the patient room size requirements. The two depths allow the modules to be mounted as in-wall, back-to-back, or surface mounted systems. The in-wall mounted headwall system is flush mounted with the room walls. The module widths are specified as the desired combined width options of the service and access panels and are 6" (15 cm) or 3 5/8" (9.21 cm) deep. Any combination of widths may be configured as necessary to meet the specific facility requirements. The back-to-back in-wall mounted headwall system is used to accommodate two rooms that are adjacent to each other and share the facility electrical and medical gas connections. The module widths are specified as the desired combined width options of the service and access panels and are 6" (15 cm) deep. Any combination of widths may be configured as necessary to meet the specific facility requirements. However, both rooms must have the same back-toback widths installed. The surface mounted headwall system is mounted on the surface of an existing wall. The module widths are specified as the desired combined width options of the service and access panels and are 3 5/8" (9.21 cm) deep. Any combination of widths may be configured as necessary to meet the specific facility requirements. The frame assemblies and panels use concealed fasteners that enable panel removal/replacement. Removable extrusion inserts seal the horizontal and vertical space between adjoining panels. Two standard and an available narrow insert can be used to create different design effects: 3/8" (10 mm) wide, flush concave profile in black or aluminum finish horizontal and vertical. 3/8" (10 mm) wide, protruding profile in black or aluminum finish horizontal and vertical. 1/8" (3 mm) narrow, vertical only, in black or aluminum finish to minimize vertical seam. The framework of the Elements Headwall System is manufactured from 16-gauge, roll formed galvanized steel channels. The Elements Headwall System height options are available in 6" (15 cm) increments from minimum to maximum height for surface mounted units: Minimum height 48" (122 cm) Maximum height 120" (305 cm) The Elements Headwall System height options are available in three heights for recess mounted units: 96" (244 cm) 108" (274 cm) 120" (305 cm) The recommended height for clinical services is within the ergonomic reach range of 18" (46 cm) to 72" (183 cm). The system electrical J box supports normal, emergency/critical power, and low voltage. The gas manifold provides five ports and ten outlets each for oxygen and air. In addition, six ports and six outlets are provided for vacuum. More manifolds can be added to increase capacity. Page 2 of 6 156515 REV 2 January 27, 2015

The Elements Headwall System is available in various service panel and access panel widths and heights. Panel widths are based on 8" (20 cm) increments and heights are based on 6" (15 cm) increments. The service panels contain outlets, switches and other devices such as medical gas connections. These panels are made from 16-gauge steel and are finished with HPL. The service panel size should be determined by the loading of specified services and medical devices to be installed. The service panels are available as follows: Width 16" (41 cm), 24" (61 cm), 32" (81 cm) Height 6" (15 cm), 12" (30 cm), 18" (46 cm), 24" (61 cm), 30" (76 cm), 36" (91 cm) The recommended vertical and horizontal spacing of specified services and medical devices that will be connected is as follows: Rows of outlets or devices 6" (15 cm) vertical In-line gas outlets 18" (46 cm) vertical Gas outlets 4 1/2" (11.43 cm) horizontal Electrical devices 1 7/8" (4.60 cm) horizontal Devices can be placed in service panels on 3" (7.6 cm) increment levels. However, there must be 6" (15 cm) between each adjacent row from centerline to centerline. Access panels are blank with no services. These panels are edge banded and made of particle board with HPL finish on front and back. They are available as follows: Width 16" (41 cm), 24" (61 cm), 32" (81 cm), 48" (122 cm) Two 32" (81 cm) panels may be combined in the center panel to provide a maximum of 64" (163 cm) bariatric bed width. Height 6" (15 cm), 12" (30 cm), 18" (46 cm), 24" (61 cm), 30" (76 cm), 36" (91 cm), 42" (107 cm) Selection of the Elements Headwall System (P2008A) side panels (height and width) should be based on equipment and service loading. Selection of the center panels should be based on the bed width, locator, or bumper considerations. Headwall Accessories The Elements Headwall System (P2008A) has these accessories: Part Number P101702 P158A P17000101 P17000202 P17000601 P17000701 P17001001 P17010102 P17010202 P17010302 P17010402 P17010501 P17011101 P17012001 P17012002 P17013001 P17020101 P17020201 P17020301 P17020401 P17030501 P17030701 P17040201 P17040401 P17041801 P17044001 P17050402 P17070101 P17070201 P17071001 P17072001 P17073001 P17073101 Description Waste receptacle ISS transfer pole ISS transfer pole mount IV pole/infusion holder Universal holder Universal pole holder IV holder Basket - stackable Basket Basket Basket Basket - pivoting Chart holder Sharps container mount Sharps container Glove box holder Utility shelf Charting shelf Small mayo tray Large mayo tray Utility light Universal light mount Integrated diagnostic system - 747 Speculum mount Utility hook Stat Clock Timer Satellite rack mount Standard slide adapter Bird a blender slide Dual clip assembly Cable organizer Vertical Cord Wrap Horizontal cord wrap January 27, 2015 156515 REV 2 Page 3 of 6

P17074001 Standard cam adapter P17090108 Gas outlet guards P17090112 Gas outlet guards P17090116 Gas outlet guards P17090120 Gas outlet guards P17090124 Gas outlet guards P17090128 Gas outlet guards P17090132 Gas outlet guards P17090136 Gas outlet guards P17090140 Gas outlet guards P53301021000 Shelf P53301051000 Shelf P53311030000 Cuff basket with mount P53321207000 Glove box holder P53321210000 Integrated diagnostic system - 767 P5332123000 Blood pressure gauge mount P53340001000 Blood pressure gauge P54000863000 Blood pressure gauge mount P962-00 Tilt swivel arm P963C01 Arm lamp with incandescent bulb P7925D120W Prima Procedural Light P967B00 STAT clock - timer, panel mount P978-01 Aneroid sphygmomanometer with coil and standard size cuff P997L00 Monitor arm P997L004 Monitor arm P53321121000 Resuscitator holder P17030202 Procedural light mount, Integris a. Bird is a registered trademark of Bird Products Corporation. Design Requirements Each Elements Headwall System module is fully functional as an independent unit. Facility rough-in requirements are accomplished by contractors in accordance with the as-built drawings and specifications. Each headwall module is customized to meet the facility room environmental requirements. Each headwall module will be configured in accordance with the latest national, state or provincial, and local codes. Duplex and simplex sockets are NEMA 1 style, hospital grade, 2 Underwriters Laboratories Inc. 3 (UL)-listed (RTRT), and rated at 125 V AC. Vacuum service tubes are copper and meet the ASTM B-819; 0.75" ID requirements. Oxygen/air service tubes are copper and meet ASTM B-819; 0.5" ID requirements. Gas service systems are assembled and tested in accordance with NFPA 99. Gas terminal outlets are UL-listed (VXHT). The outlets are available in quick-disconnect or DISS, which conforms to the CGA V-5:2005: Non-Interchangeable Low Pressure Connection for Medical Gas Applications Standard. Components per Headwall Each headwall module is configured and shipped as specified on the original order. Options are preinstalled by WittRock. Electrical System Each module may be configured with 120, 240, and/or 277 V AC; 60 Hz electrical service, and up to 30 A per branch circuit. 1. NEMA is a registered trademark of National Electrical Manufacturers Association, Inc. 2. Hospital grade is indicated by a green dot on the face of the outlet. 3. Underwriters Laboratories Inc. is a registered trademark of Underwriters Laboratories Inc. Page 4 of 6 156515 REV 2 January 27, 2015

Quality Assurance The Elements Headwall System (P2008A) meets all applicable current NFPA 99 and NFPA 70 standards and conforms to all national, state, and local codes. Installation and Maintenance All headwall modules are pre-assembled with the specified options installed at the factory. The contractor will install all modules in accordance with as-built drawings and all national, state, and local codes. Service For a list of service parts available for the Elements Headwall System, refer to the Elements Headwall System Operation and Maintenance Manual (155482). Submittals Shop drawings shall be submitted in accordance with supplemental, general, and special conditions of specifications and contract documents. The Elements Headwall System (P2008A) manufacturer shall send within 30 days of contract award complete detailed shop drawings that detail items in plan and elevation. Drawings shall detail the dimensions and interface to the related services, which require to be cut or close fitted. Item fabrication shall not be started until complete final approvals are received. The Elements Headwall System (P2008A) manufacturer shall supply physical samples only if specifically asked, and the cost of same has been negotiated. The color of HPL shall be selected by the architect or customer from the manufacturer's standard line. The manufacturer shall supply color charts. The manufacturer reserves the right to furnish the Elements Headwall System (P2008A) and its related components with improvements in design and/or materials at the time of manufacture. Warranty Refer to the operation and maintenance manual for the warranty (see Elements Headwall System Operation and Maintenance Manual (155482)). Product Numbers You can order the Elements Headwall System (P2008A) in three module widths and two module depths. For more information, call WittRock customer service. Table 1. Elements Headwall System Product Number P2008A1 P2008A2 P2008A3 P2008A5 Description Floor-Standing In-Wall Model Series Floor-Standing Surface-Mount Model Series Back-to-Back In-Wall Model Series Floor-Standing In-Wall Surface- Mount Mix Series January 27, 2015 156515 REV 2 Page 5 of 6

8829 STATE ROUTE 46 E GREENSBURG, IN 47240 USA Customer Service: 812.222.0373 Fax: 812.222.0281 www.wittrockhc.com American National Standards Institute is a registered trademark of The American National Standards Institute. American Society of Mechanical Engineers is a registered trademark of The American Society of Mechanical Engineers. American Society for Testing and Materials International is a registered trademark of American Society for Testing and Materials. ASME is a registered trademark of The American Society of Mechanical Engineers. ANSI is a registered trademark of The American National Standards Institute. ASTM is a registered trademark of American Society for Testing and Materials. Bird is a registered trademark of Bird Products Corporation. CGA is a registered trademark of Compressed Gas Association, Inc. Elements is a registered trademark of WittRock Healthcare. National Electrical Code is a registered trademark of National Fire Protection Association, Inc. NEC is a registered trademark of National Fire Protection Association, Inc. National Fire Protection Association is a registered trademark of National Fire Protection Association, Inc. NEMA is a registered trademark of National Electrical Manufacturers Association, Inc. Underwriters Laboratories Inc. is a registered trademark of Underwriters Laboratories Inc. WittRock, Inc. reserves the right to make changes without notice in design, specifications, and models. The only warranty WittRock makes is the express written warranty extended on the sale or rental of its products. 2015 by WittRock, Inc. ALL RIGHTS RESERVED. No part of this text shall be reproduced without written permission from WittRock, Inc. Page 6 of 6 156515 REV 2 January 27, 2015