APPENDIX J ILLUSTRATIONS

Similar documents
Read Only Document Not For Distribution

PLUMBING REQUIREMENTS

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

1 Exam Prep Plumber s Handbook Tabs and Highlights

Read Only Document Not For Distribution

Sanitary Drainage Systems

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

Level I Chapter 1 Worksheet

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

PLUMBING INSTALLATIONS

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

STACKS AND STACK VENTS

Pipe Sizing Table. Hydraulic Load Served (fixture units)

2016 Plumbing Supplemental Plan Review List

DUKE UNIVERSITY CONSTRUCTION STANDARDS

CHAPTER 9 VENTS SECTION

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Read Only Document Not For Distribution

MATERIALS Traps TRAPS. No. IPC IRC Description

1 Exam Prep Plumbing State Contractors Practice Exam 2

PLUMBING FIXTURES CHAPTER 27

c. Direct or indirect?

A GUIDE TO PASSING THE PLUMBING EXAM

CHAPTER 10 TRAPS AND INTERCEPTORS

APPENDIX L ALTERNATE PLUMBING SYSTEMS

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

PLUMBING FIXTURES Reserved

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

2015 UPC Chapter 8 Indirect Wastes RV

Test Code: 8117 / Version 1

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

Building Utilities 1 Plumbing and Sanitary Systems

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

Special Requirements For Health Care Facilities

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Structural Guidelines. Food Service Establishments. Retail Food Stores

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

GARCIA GALUSKA DESOUSA Consulting Engineers

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Is Sewer Gas Giving Your Customers the Wrong Impression?

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

Plumber Level 3 Rev. May 2011

Engineering Fact Sheet

FEATURES. Other Fed-Flush Arrangements

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

A. Section Joint Sealants: Seal fixtures to walls and floors.

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

CHAPTER VI BUILDING PLUMBING

Gulfport, Mississippi 21 May 2007

Plumbing Technology/Plumber CIP Task Grid

plumbing for greywater

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

A. This Section includes the following domestic water piping specialties:

ASME STANDARDS IN MODEL CODES

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section.

Series 300 VTB. Installation Instructions

Plumber Practice Interprovincial Red Seal Exam

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

APPENDIX F: GREASE SEPARATION DEVICE SIZING OPTIONS

Food Establishment Guidelines. Food Service Plan Review

BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

GREASE SEPARATION DEVICE SIZING OPTIONS

ENERGY MARKETING SERVICES

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

PLUMBING CURRICULA OUTLINE

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

There are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance.

1. You are required to use a 20 foot ladder placed up against a building that is 40 high. At what

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

Frequently Asked Questions

NEW WATER CONNECTION PROCEDURES FOR HOPE AND EDENVILLE TOWNSHIP RESIDENTS

Design of Precast Concrete Grease Interceptors

GENERAL PLUMBING NOTES

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION STEAM CONDENSATE PUMPS

HVAC Equipment Access Equipment Location

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Transcription:

The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely to illustrate. The various methods indicated diagrammatically do not limit other configurations of design of plumbing, soil, waste and vent systems, water piping, accessories, etc., when in compliance with the written text. It is further suggested that the users of these illustrations refer to the appropriate sections and standards regarding any of the figures to avoid misunderstanding. APPENDIX J ILLUSTRATIONS (APPENDIX J IS FOR INFORMATIONAL PURPOSES ONLY) BRICK GLASS ALL VENT SIZED BY CONVENTIONAL METHOD EXCEPT THAT WHEN FIX- TURES DRAIN INTO EITHER VENT A OR B STACK UP THROUGH DRAIN FITTING SAME SIZE AS HORIZONTAL POSITION OF SYSTEM PRECLUDES CONVENTIONAL VENT SYSTEM SIZE BY CONVENTIONAL VENT SYSTEM SINK w/ GREASE STACK B (REQUIRED) INTERCONNECT DOWNSTREAM OF THIS VENT FLOOR DRAIN WRT TYP. STACK A (REQUIRED) FLOOR SINK TYP. SINK 2 1/2" MIN. EXCEPT FOR UNDERGROUND REQUIREMENTS (714.4) FLOOR DRAIN w/ P-TRAP TYPICAL MIN. FLOOR DRAIN SIZE NEED NOT BE GREATER THAN 3" DUE TO REQUIREMENTS OF SEC. 409.4 FOR FIXTURE UNITS VALUES SEE TABLE 713.2 6" MIN. FOR TOTAL OF 96 FIXTURE UNITS 2 PIPES SIZES LARGER THAN REQUIRED BY TABLE 714.1 IF COMBINATION WASTE AND VENT SYSTEM DRAINS INTO A SOIL OR WASTE STACK ON UPPER FLOORS, SIZE COMBINATION WASTE & VENT BRANCH TWO SIZE LARGER THAN REQUIRED BY TABLE 714.2 FOR THIS JOB ALL FLOOR DRAINS & FLOOR SINKS MIN. SIZE 3" (5 F.U. EACH) TABLE 713.3 FOR OTHER FIXTURE UNITS RATINGS SEE TABLE 713.2 Figure 6 COMBINATION WASTE AND VENT SYSTEM Louisiana State Plumbing Code, 2000 edition 123

EXAMPLES OF DISTANCES PERMITTED IN A COMBINATION WASTE AND VENT SYSTEM (24" MAX.) 1001.9 LONGER LENGTHS MAY SUBJECT TRAP SEAL TO PRESSURE GREATER THAN 1" WATER COLUMN DISTANCE LIMITED FLOOR DRAIN- BY TABLE 908.1 INDIRECT WASTE RECEPTOR WIT C.O. AT FLOOR VERTICAL C.O. OR HUB NOT PERMITTED HERE (WOULD INTERFERE WITH CLEANING) LEVEL-807.1 C.O. BY TABLE 908.1 MAXIMUM NOT SPECIFICALLY LIMITED BUT NORMAL ROUGHING FOR ABOVE FLOOR SINK OR OTHER FIXTURE TRAP IN A COMBINATION WASTE & VENT SYSTEM C.O. FLOOR DISTANCE LEVELLIMITED DISTANCE LIMITED POINT (B) SHOULD NOT EX-CEED DISTANCE PERMITTED FOR INDIRECT WASTE TO VENT (805.1) DISTANCE NOT SPECIFICALLY LIMITED BY TABLE, GOVERNED BY AVAILABLE FALL INVERT AT POINT (A) SHOULD NEVER BE AT AN ELEVATION ABOVE THE FIXTURE BRANCH FITTING AT POINT (B) INVERT POINT (A) Figure 7 124 Louisiana State Plumbing Code, 2000 edition

FOR OVER RIM BATH FILLERS MINIMUM AIR GAP-2" FOR OPENINGS 1" OR LESS IN DIA. FOR LARGER OPENINGS & EFFECTS ON SIDE WALLS SEE ANSI A112.1.2 FLOOD LEVEL IS HERE NOT TO BE CONSTRUCTED AS THE FLOOR LEVEL EXAMPLE OF AIR GAP REQUIREMENTS FOR BATH FILLERS (SEE SECTION 606) DRAIN WITH OVERFLOW THE BOTTOM OF THE BACKFLOW PREVENTER IS THE CRITICAL LEVEL UNLESS OTHERWISE MARKED WITH THE SYMBOL C-L OR C L ATMOSPHERIC TYPE BACKFLOW PREVENTER OUTLET AIR GAP = 2xDIA. SEE SEC. 806 ANSI A WASTE- PIPE DIA. FLOOD LEVEL CRITICAL LEVEL POINT 5" ABOVE FLOOR LEVEL RIM ANSI/ASSE 1001-1982 SECTION 1.2 TEMPERATURE CONTROL JACKET PROTECTION INDICATED IS SUITABLE FOR THIS JOB ONLY (JOB CONDITIONS MAY REQ. OTHER PROTECTION) WATE R SHUTOFF VALVE MAY BE INSTALLED ON INLET SIDE ONLY REFERENCE ANSI/ASSE 1001-1982 SECTION 1.2 TANK DRAIN CHEMICAL MIXING TANK WITH WATER JACKET (SEE 606) Figure 8 Louisiana State Plumbing Code, 2000 edition 125

REMOVABLE ACCESS PANEL SEE 506 ACCESSIBLE SPACE UNDER COUNTER CONTINUOUS PERMANENT COUNTER TOP ANTI SIPHON - HOLE IN DRIP TUB 6" MAXIMUM FROM TANK TOP INPUT OF ELECTRIC HEATER WATTS x 34138 Btu HOT WATER SUPPLY COLD WATER SUPPLY EXAMPLE OF BUILT IN WATER HEATER WITH ACCESS TO RELIEF VALVE & SHUTOFF VALVE T & P VALVE DRAIN FULL SIZE OF THREADED VALVE OUTLET Figure 9 126 Louisiana State Plumbing Code, 2000 edition

FLOOD LEVEL DISPOSAL SINK WATER SUPPLY TO PROVIDED PROTECTION, VACUUM RELIEF VALVE MUST BE IN COLD WATER SUPPLY AND LOCATED ABOVE TANK TOP T & P HOT WATER SUPPLY TANK TOP VACUUM RELIEF VALVE (SEE SEC. 507.1) REQUIRED ON BOTTOM INLET TANKS OR TANKS NOT EQUIPPED WITH ANTI-SIPHON TUBES APPROVED ONLY WHEN OUTLET OF VACUUM BREAKER OPEN TO ATMOSPHERE NOT APPROVED SOLENOID VALVE CLOSES OFF VACUUM BREAKER OUTLET PLACING VACUUM FLOOD LEVEL FOOD WASTE GRINDER DISPOSAL SINK FOOD EXAMPLE OF BACK SIPHON WASTE PROTECTION GRINDER BREAKER UNDER CONSTANT PRESSURE (SEE ANSI/ASSE 1001-1982) SOLENOID OR OTHER SHUTOFF VALVE FULL SIZE OR RELIEF VALVE OUTLET VACUUM BREAKER WATER SUPPLY SHUTOFF VALVE IMPROPERLY LOCATED SOLENOID OR OTHER SHUTOFF VALVE TO APPROVED TERMINAL TEMPERATURE SENSING ELEMENT IN HOTTEST WATER IN TANK NOT MORE THAN 6" DOWN FROM TOP SAFETY AND ANTI-SIPHON DEVICES (SEE SEC. 501.8.1 & 507.1) COLD WATER SUPPLY SHUTOFF VALVE MAXIMUM DISTANCE FROM HEATER 3'-0" WHEN SEPARATE TEMPERATURE AND PRESSURE RELIEF VALVE ARE USED PRESSURE RELIEF VALVE MAY BE LOCATED IN THE COLD WATER SUPPLY BETWEEN SHUTOFF VALVE AND TANK OR HEATER Figure 10 Louisiana State Plumbing Code, 2000 edition 127

DANGER NO PROTECTION FROM BACK FLOW COMPRESSED AIR SUPPLY TANK SLOWDOWN WATER SUPPLY COMPRESSED AIR FILLER CAP MIXTURE TO POINT OF USE WATER & TOXIC MATERIAL DANGER INADEQUATE PROTECTION FROM BACK-FLOW VACUUM BREAKER COMPRESSED AIR SUPPLY TANK WATER SUPPLY BLOW DOWN COMPRESSED AIR SUPPLY TANK MIXTURE TO WATER SUPPLY AIR GAP BLOW DOWN COMPRESSED AIR WATER & TOXIC MATERIAL COMPRESSED AIR WATER & TOXIC MATERIAL CHECK VALVE FILLER CAP FILLER CAP SAFE PROTECTED FROM BACK-FLOW VACUUM BREAKER HIGH PRESSURE UNITS SUCH AS USED IN CAR WASHERS TO SUPPLY WATER & DETERGENT TO WHEEL WASH & OTHER UNITS UNDER HIGH PRESSURE Figure 11 128 Louisiana State Plumbing Code, 2000 edition

#3 BARS AT 10" o.c. EACH WAY MANHOLE FRAME & COVER 29" MIN. STABILIZED SOIL OR AGGREGATE SUB-BASE 18" TO 24" FINISHED ELEVATION GROUT ±25" CAST IRON FRAME & COVER FOR HEAVY TRAFFIC CONCRETE ADJUSTING DOUGHNUT(S) 1/2" MORTAR AND WATER SEAL CONCENTRIC CONCRETE CONE 2' 5" WATER SEAL GASKET AT ALL JOINTS AND MORTAR FILL VARIES MIN. 5" WALL- THICKNESS (MIN. 6" IF FORMED AND POURED-IN-PLACE) 12" 4' - 0" MIN. GROUT PRECAST CONCRETE SECTION OR POURED-IN-PLACE REINFORCED CONCRETE 4x4-4/4 W.W.F. (CENTER IN WALL) NOTE: ALL SECTIONS TO BE CUSTOM MADE AND CONFORM TO ASTM SPEC. DESIGNATION C-478-1 FOR PRECAST CONC. MANHOLE RISERS 8" TOPS OPENINGS FOR SEWER PIPE CAN BE MADE AT ANY LOCATION WATER SEAL AROUND ALL SEWER PIPE PENETRATIONS 8" MIN. 3"CL Typical Sewer Manhole Figure 13 Louisiana State Plumbing Code, 2000 edition 129

LAVATORY COUNTER TOP OR WALL HUNG GYPSUM BOARD & STUD WALL Floor Drain WATER SAVER TRAP PRIMER CLEANOUT PLUG FLOOR FLOOR DRAIN 1/2" PIPING IN WALL AND UNDER FLOOR SLOPE TO FLOOR DRAIN P-TRAP Trap Primer Detail Figure 14 Number of Meals Per Peak Hour 1 Alternate Formula For The Sizing Of Grease Traps x Waste Flow Rate 2 x Retention Time 3 1. Meals Served at Peak Hour x Storage Factor 4 x Interceptor Size (liquid capacity) 2. Waste Flow Rate a. With dishwashing machine... 6 gallon (22.7 L) flow b. Without dishwashing machine. 5 gallon (18.9 L) flow c. Single service kitchen 2 gallon (7.6 L) flow d. Food waste disposer. 1 gallon (3.8 L) flow 3. Retention Times Commercial kitchen waste Dishwasher.. 2.5 hours Single service kitchen Single serving. 1.5 hours 4. Storage Factors Fully equipped commercial kitchen. 8 hour operation 1.. 16 hour operation 2.. 24 hour operation 3 Single Service Kitchen. 1.5 Figure 15 130 Louisiana State Plumbing Code, 2000 edition