RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Similar documents
RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Fiber Optical Multiplexer

T3/E3 Fiber Optic Line Drivers

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

RS485 MODBUS Module 8AI

FCD-wire Contents. List of Figures

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

Instruction Manual Model Backup Switch, 1 for 8

Installation Guide for inbiox60 Series Access Control Panel

Roo232 User Guide. Revision 1.0. Copyright 2006 RoboDynamics Corp

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Vector System. User Manual

OPERATION / INSTALLATION

DS3/STS-1 Protected Repeater System User Manual

4120 Fire Alarm Network Reference

600 Range Dialer Installation Manual. Version 1.0

21-light Remote Annunciator. Owner s Manual

C-Bus Four Channel General Input Unit Installation Instructions

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

EOTec 2C32 Installation Guide

4009 Fiber Optic Link Option Installation Instructions

MT-RJ Optical Fiber System Field Testing

4100U City and Relay Cards Installation Instructions

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

InBio X60 Series Access Control Panel User Manual

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Fratech Multipath-IP

USER MANUAL FOR OPERATING SYSTEM

Public Safety DAS Annunciator Panel

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

/9308 External Battery Chargers Installation Instructions

Four channel video link For low cost video transmission

IR Intelligent Speed Dome Installation Manual

SCR100 User Manual. Version:1.1 Date:Dec 2009

HRX Technical Manual. Version 1.2

UNC100 Integra Manual

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

RMS/RPX Reader. User Manual

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

P2267 NETWORK INTERFACE

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Analog Input Module IC670ALG630

GPS Evaluation Kit EVA1037/1080

OVEN INDUSTRIES, INC.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

IF-L/RF Protection Switch

FiberSensor Fiber Optic Intrusion Detection System (IDS)

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Analog Room Pressure Monitor RPC Series

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

FIRERAY 5000 range USER GUIDE

EPON ONU Optical Transceiver SFF Module

HDCVI PIR Camera User s Manual

Fiber Optic Cable Fence Disturbance Sensor

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

2-inch HDCVI Speed Dome Installation Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Dual SDI Optical to Electrical Converter

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

6-inch Intelligent Speed Dome Installation Manual

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Added password for IP setup page : Password must be in IP format!

HRX3000. Technical Manual

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

4 Channel Contact Closure SFP DIN Fiber Link System

1.1 The Network Communications Module for Wire (NCM-W) Channel A & B Connections. Network Connection Ports (NUP)

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

SIMATRIX NEO Modular Video Matrix

IR Intelligent Positioning System Installation Manual

TM-76, MD-76 MODEM OPERATING MANUAL. IOA76-1F May 2009 LANEX S.A., 8 Ceramiczna Street, Lublin Service: phone POLAND

Quick Alert Remote (QA216R)

WatchDog Wireless Crop Monitor Operation Manual

5000 INSTALLATION GUIDE

Technical Manual. Level Alarm Unit CARLA & WIDS

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

Features

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks


INSTALLATION INSTRUCTIONS

IR Intelligent Speed Dome Installation Manual

MT-374B/364B Operation User s Guide. The Anti-Sweat Energy Saving Controller user s manual


4-Channel Contact Closure Fiber Link Card System

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

Addressable IDNet Isolator Installation Instructions

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

USER'S MANUAL. Real Time Color Quad Processor. High Resolution, Broadcast Quality. Playback Zoom Function. RS232 Remote Control

Transcription:

RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005)

1. Cautions Please read the following notices carefully before installing and using the device, Raisecom does not respond to any loss that caused by violating safety notice. This series fiber-optic multiplexer is integrated device that has precise elements, please avoid violent shakes and impacts, and do not disassemble or maintain the device yourself. If it is required, please do it under the guide of our technical staff following in the steps of anti static. Please contact us if there is any need. There must be grounding protection for the sake of safety; do not disassemble the device yourself, we regard it as you waiver your rights of repair guarantee. 1

Contents 1. Cautions...1 2. Overview...3 2.1. Introduction...3 2.2. Main Features...3 2.3. Part Number Introduction...3 3. Parameters...5 3.1. E1 Interface Specification...5 3.2. Optical Interface Specification...5 3.3. Ambience...5 4. How to use...6 4.1. Introduction of the Front Panel...6 4.2. DIP-switches Configuration...7 4.2.1. Dip-switches for E1 Interface Impedance...7 4.2.2. DIP-switch for Function Configuration...7 4.2.3. DIP-switch for Manufactures Setup...8 5. Installation and Test...9 5.1. Inspect after Opening...9 5.2. Preparation before Installation...9 5.3. Installation Procedure...9 5.3.1. Installing the Module into the Chassis...9 5.3.2. Connecting Cables...9 5.3.3. Applying the Power Supply...10 5.3.4. Mask/No Mask Button...10 6. Appendix A Introduction of Cable Making...12 A.1 E1 Cable...12 2

2. Overview 2.1. Introduction RC800-240B series fiber-optic multiplexers are ideal fiber-optic transmission devices for point-to-point networks, medium-sized and small capacity networks, such as wireless communication base stations, private communication networks, and switching networks. The transmission capacity of RC800-240B is 8 E1 channels. RC802-240B and RC804-240B fiber-optic multiplexers are the modular versions of RC800-240B. They can be installed into RC004-16 16-slot chassis to be deployed at the host site. The standalone multiplexers can be deployed at the remote site to work in pairs with the ones at host site, and be managed by network management software. 2.2. Main Features Very large scale ASIC chips ensures low power consumption; 4-layer PCB ensures high reliability Complete alarm indication that can display local and remote alarms simultaneously Alarm lock memory and E1 channel loop-back test capabilities implements convenient operation and maintenance Provides 1 optical interface and 8 E1 channels and support cascading RC802-240BS expansion sub-module to provide 16 E1 channels capacity. With modular design, it can be installed into any slot form 1 st to 15 th. If cascading connection is required, it can be only installed into odd slots. One modular multiplexer shall correspond to one standalone multiplexer at the remote site. Support SNMP management. It can be managed by the network management module in the MPU slot of RC004-16 chassis. It also support out-of-band management of standalone multiplexer at the remote site. 2.3. Part Number Introduction RC800-240B series multiplexers include the following models. Part Number Description RC802-240B-S1 Host-site module, 8 E1, 1 optical port, dual-strand single mode (DSC), 0-25 Km RC802-240B-S2 Host-site module, 8 E1, 1 optical port, dual-strand single mode (DSC), 10-60 Km RC802-240B-S3 Host-site module, 8 E1, 1 optical port, dual-strand single mode (DSC),15-120 Km RC804-240B-S1 Host-site module, 8 E1, 1 optical port, single strand single mode (SC-PC), 1310 TX, dual-wavelength, 0-25 Km RC804-240B-S2 Host-site module, 8 E1, 1 optical port, single strand single mode (SC-PC), 1310 TX, dual-wavelength, 10-60 Km RC801-240B-S1 Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, dual-strand single mode 3

RC801-240B-S2 RC801-240B-S3 RC803-240B-S1 RC803-240B-S2 RC805-240B-S1 RC805-240B-S2 (DSC), 0-25 Km Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, dual-strand single mode (DSC), 10-60 Km Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, dual-strand single mode (DSC), 15-120 Km Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, single strand single mode (SC-PC), 1310 TX, dual-wavelength, 0-25 Km Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, single strand single mode (SC-PC), 1310 TX, dual-wavelength, 10-60 Km Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, single strand single mode (SC-PC), 1550 TX, dual-wavelength, 0-25 Km Remote-site standalone, max 8 E1, 2 expansion slots, 1 optical port, single strand single mode (SC-PC), 1550 TX, dual-wavelength, 10-60 Km RC802-240BS Host-site module, cooperate with RC802/804-240B to provide the 9 th 16 th E1 channels The shaded texts in the above table indicate the models that are covered by this manual. Generally, it is required to add a suffix to the standalone RC801/803/805 series equipment to indicate the type of power supply. For example, RC801-240B-S1/AC indicates AC 220V power supply; RC801-240B-S1/DC indicates DC -48V power supply. When interconnecting the fiber-optic multiplexers, it is suggested that follow the rules below. The modular multiplexer shall be installed into host-site chassis. Host-site module or Remote-site module standalone RC802-240B-S1 RC801-240B-S1 RC802-240B-S2 RC801-240B-S2 RC802-240B-S3 RC801-240B-S3 RC804-240B-S1 RC805-240B-S1 RC804-240B-S2 RC805-240B-S2 RC802-240B-S1 combined RC801-480B-S1 with RC802-240BS RC802-240B-S2 combined RC801-480B-S2 with RC802-240BS RC802-240B-S3 combined RC801-480B-S3 with RC802-240BS RC804-240B-S1 combined RC805-480B-S1 with RC802-240BS RC804-240B-S2 combined RC805-480B-S2 with RC802-240BS Note: the above interconnection rules are the most common ones that modular multiplexers work in pairs with standalone versions. The remote network management can also be implemented when standalone multiplexers are deployed at both sites. 4

3. Parameters 3.1. E1 Interface Specification Bit rate: 2048Kbps±50ppm Line code: HDB3 Impedance of interface: 75Ω (unbalanced) or 120Ω (balanced) Electrical characteristics: complies with ITU-T G.703 Transfer characteristics: complies with ITU-T G.823, G.724 Input jitter tolerance: complies with ITU-T G.823, G.724 3.2. Optical Interface Specification Bit rate: Line code: Fiber connector: Part Number Connector Type 100Mbps 4B5B SC Wavelength (nm) Launch Power (dbmw) Receiving Sensitivity (dbmw) Transmission Distance (Km) Link Loss (db/km) RC802-240B-S1 DSC 1310-15 ~ -8-34 0 ~ 25 0.5 RC802-240B-S2 DSC 1310-5 ~ 0-34 10 ~ 60 0.5 RC802-240B-S3 DSC 1550/DFB -5 ~ 0-36 15 ~ 120 0.25 RC804-240B-S1 SC/PC 1310-12 ~ -3-30 0 ~ 25 0.5 RC804-240B-S2 SC/PC 1310-5 ~ 0-32 10 ~ 50 0.5 RC804 series are equipped with single strand dual-wavelength optical ports. The 1310nm is the TX wavelength, and the RX wavelength is 1550nm 3.3. Ambience Working temperature: 0 ~ 45 Relative humidity: 90% (25 ) 5

4. How to use 4.1. Introduction of the Front Panel Fixing Handle Power (Green), ON when works properly L line indicates local alarms, R for remote alarms LOS1~8 E1 alarms (Red): ON when loss of signal in E1 channels LOS optical alarm (Red): ON when loss of signal in optical link LOF optical alarm (Red): ON when loss of frame in optical link E-3 optical alarm (Red): flashing when severe BER exceeds 10-3 E-6 optical alarm (Yellow): flashing when BER exceeds 10-6 Fiber connector: DSC/PC for dual-strand fiber, TX for transmit and RX for receive; SC/PC for single strand fiber Mask fake alarm button: Push-in, mask E1 fake alarms; push out, unmask. Valid for both Unit 1 and Unit 2 Fixing Handle Figure 1. Sketch of RC802-240B, RC804-240B front panel The front panel includes the indications of E1 receiving signal loss alarms and optical alarms. All the alarms are for the receiving link (signal input). The Line L indicates the alarms generated at the local site and Line R at the remote site. The remote alarms are 6

sent through the optical link, so that they are accurate only when the optical receiving is working in good condition. 4.2. DIP-switches Configuration 4.2.1. Dip-switches for E1 Interface Impedance There are 8 groups of 4-bit dip-switches, SW1 to SW8. These switches cannot be managed by network management software, so they must be set manually. Definition as shown below 1 st 2 nd 3 rd 4 th 1 st 2 nd 3 rd 4 th ON ON ON OFF Or OFF OFF OFF ON 75Ω unbalanced signal effective 120Ω balanced signal effective As shown in figure above, the default status is set as 75Ω unbalanced signal BNC interface effective. When adopting 75 Ohm unbalanced signal, it is required to plug a DB37 to 8 CC3 coaxial adapter, which is of CC4B-8G type. This adapter can convert DB37 connector to 8 CC3 coaxial connectors, for input and output of 4 E1 channels. When adopting 120 Ohm balanced signal, it is required to first set the dip-switches as per the above tables. 37-pin connector shall be used to connect the twisted-pair cables for DB37 connector. Please refer to Appendix A for details of sequence of twisted-pair and cable making. 4.2.2. DIP-switch for Function Configuration ON OFF 1 2 3 4 There is a 6-bit dip-switch SW10 on the PCB. ON 1 st ~ 4 th : Loop-back control OFF 1 2 3 4 5 6 1 st bit 2 nd bit 3 rd bit 4 th bit Loop-back OFF OFF OFF OFF No loop-back OFF OFF OFF ON 1 st E1 OFF OFF ON OFF 2 nd E1 OFF OFF ON ON 3 rd E1 OFF ON OFF OFF 4 th E1 OFF ON OFF ON 5 th E1 OFF ON ON OFF 6 th E1 OFF ON ON ON 7 th E1 ON OFF OFF OFF 8 th E1 ON ON ON ON All E1 links Note: Only two test method can be set: single E1 channel loop-back or all E1 channels loop-back. When single E1 channel loop-back is testing, the other channels are working normally without disturbance. The network management software can send out the loop-back enable/disable command, and they have high priority to the settings by hardware. 7

5 th bit: loop-back type options This switch is used to choose remote loop-back or local loop-back when performing the E1 loop-back operations. 5 th bit Loop-back type option OFF Remote loop-back enable ON Local loop-back enable BER tester Multipl exer Fiber Multipl exer E1 E1 Local Remote Figure2: sketch map of setting remote loop-back on local site BER tester Multipl exer Fiber Multipl exer E1 E1 Figure3: sketch map of setting local loop-back on local site Note: When any loop-back is set on local site, 1 st ~ 4 th loop- back DIP-switch of remote site must be all off (not loop-back). 6 th bit: Vacant. Local Remote 4.2.3. DIP-switch for Manufactures Setup The 4-bit dip-switch SW11 is used by the manufacturer to configure the module during manufacturing. Users are not advised to change its default status. 8

5. Installation and Test 5.1. Inspect after Opening Please first check if the models and part numbers are in consistence, and also check if the equipments are damaged. 5.2. Preparation before Installation Carefully read this manual Prepare all kinds of the cable. Ensure that they are not short-circuited. Refer to Appendix A for cable making. Ensure RC004-16 is properly installed, and the chassis is well connected with the ground. Prepare the BERT and optical power meter for test of line quality. Change the dip-switch setting on the bottom panel if 120 Ohm balanced signal interface is required. Set up the fault-pass-through enabled if using the function. This module does not support hot-swapping 5.3. Installation Procedure 5.3.1. Installing the Module into the Chassis Insert the module into any service slot from 1 st to 15 th, with PWR indicator upside. The MPU slot is particular for the network management module, thus cannot be inserted with service modules. Installing fiber-optic multiplexer in MPU slot will cause damage to the module itself or the back panel of the chassis. When combining with RC802-240BS expansion slave module, RC800-240B module will act as the master. The master module shall be installed into odd-number slots, for example, Slot 1, 3, 5 and 13. The slave module shall be installed into even-number slots, for example, Slot 2, 4, 6 and 14. Slot 15 does not support combining. 5.3.2. Connecting Cables E1 port The upside of RC004-16 chassis, corresponding to fiber-optic module, has 2 groups of DB37 male interfaces. The upper one is for the 1 st 4 th E1 channels, and the lower one for the 5 th -8 th channels. It is suggested that users use SYV75-2-2 coaxial cables to connect the BNC connector. Users can connect a CC4B-8G adapter on DB37 male interface to connect CC3-K3 coaxial cables. 9

If using 120 Ohm balanced interface, users can connect the DB37 male interface with DB37 female-connector twisted-pair. Optical interface Plug the SC fiber tail into optical interface (push hard until to the deep end). If not sure about transmission direction, it s advised first to turn on the power of device and then plug in the fiber cable. 5.3.3. Applying the Power Supply When PS is turned on, the PWR indicator shall be on. After applying the power supply, first please ensure there is no alarm at the optical port. If the optical port is connected properly, there shall not be LOS alarm. When just applying the power supply, the E-6 (yellow) indicator shall be on. This is because of the few error bits generated by the jitters. It shall be out after 10 20 seconds. 5.3.4. Mask/No Mask Button If the connected E1 links are working in good condition without any signal loss, while there is still another unused E1 link, the LOS alarm for unused E1 link may occur, which is called unused E1 alarm. Press MASK/NO MASK button on to clear all the unused E1 alarm and all the E1 LOS alarm indicators will be off. In the case unused E1 link alarm being masked, if the connected E1 sub-channel is disconnected, the LOS indicator of this sub-channel will still be on. If power supply is cut off and turned on again, then the mask function will be disabled. Press button to off and then pressed to on again. If after a period of operation, a new E1channel is needed, first disable the mask function and then connect E1 link. Chapter 4 Troubleshooting If there are any problems during installation and using, try the following proposals. If the problems still can not be solved, please contact distributors/agents for help. The following explanations and solutions for alarms at optical ports and LOS alarms at E1 ports are used to handling local alarm problems. For remote-end alarms, please handle them at remote site. Green PWR indicator not on Answer: PS faults or PWR indicator is not functioning. Check the power supply of RC004-16. LOS red indicator of optical port is on Answer: Loss of receiving signal occurs at optical port. Check whether the input fiber (RX) is connected well and ensure not reversed. Or check the receiving optical power with optical power test-meter; it should be greater than receiving sensitivity specification. E-6 yellow indicator of optical port is on Answer: The bit error of optical RX signal is greater than 10-6. It is normal that E-6 alarm occurs for 10 seconds just after turning on the power, after 10 seconds the E-6 indicator will be off. If E-6 alarm occurs during operation, check whether optical RX port connects well and RX optical power. 10

LOS red indicator of E1 sub-channel is on Answer: Loss alarm of RX signal at E1 sub-channel, no HDB3 signal is received. Check whether all E1 ports are connected well, or whether 75Ω cables are reversely connected, or whether the wires of 120Ω cables are in correct sequence. If LOS alarm occurs at unused E1 sub-channel, press mask button to on to musk the alarm after finishing the configuration of device. Mask button is on, but there is still alarm in unused E1 sub-channel. Answer: probably the mask function is disabled if power supply is cut off and then turned on. To solve is by pressing the mask button to OFF, and then pressing to on to enable mask function. How to unplug the coaxial cable from the coaxial connector. Answer: push the thickest part of the connector without turning, and then pull out the coaxial cable. 11

6. Appendix A Introduction of Cable Making A.1 E1 Cable 75 Ohm signal adopts DB37 coaxial adapter: SYV 75-2-2 coax cable, the distance shall not be longer than 200m. First pick out the CC3-K3 connector from the accessories, and release the tail protecting jack. Secondly, separate the core from the shield, and put the tail protecting jack on it. Solder the strand with the core of the CC3-K3 connector. Solder the cable shield with the shield of the CC3-K3 connector. Finally, fix the jack at the end of the connector. 120 Ohm signal adopts DB37 male connector: DB37 Pin Definition 1 st Channel 2 nd Channel 3 rd Channel 4 th Channel OUT 3, 4 7, 8 11, 12 15, 16 IN 21, 22 25, 26 29, 30 33, 34 Others - GND 12

@2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification. 13