USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

Similar documents
RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Logic+ Combi

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

User Instructions For TopTronic RS-30

USER GUIDE LOGIC HEAT H

irad Wireless Controller

USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

3 Channel Multi-Purpose Programmer User Instructions

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

WEATHER COMPENSATION KIT

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

ES3247B. 3 Channel Programmer. User and Installation Instructions

Vokèra OpenTherm 711 with external sensor connected

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

2 Minimiser SE - User's

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Vokèra OpenTherm 711 without external sensor connected

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

User Guide for EHE & EHE Programmable Room Thermostat

Version 1.03 January-2002 USER S MANUAL

USER'S OPERATING INSTRUCTIONS

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Panel Convector Heater User Instructions

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Operation Manual - PC-ARF - P IMPORTANT:

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

AUTO CM CM USER GUIDE

GB24 & GB30. User Manual

ES-LCD User Control SD Card Location

User Manual THR870CUK Programmable Thermostat

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

Planet Super4F.S. User Instructions

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Your Daikin Altherma remote controller

User Guide Y9420H Sundial RF 2 Pack 2

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Underfloor Heating Programmable Thermostat

IE Instructions and warning book CRONO 7. Weekly digital chronothermostat

Safety & Installation Instructions

User Manual THR872CUK Wireless Programmable Thermostat

Daikin Altherma high temperature remote controller guide for schedule timers and operation functions

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

REMOTE CONTROL FOR CHILLER MYCHILLER

CS027 User Instructions

Xtralis VESDA LCD Programmer Quick Reference Guide

Intelligent Security & Fire Ltd

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

C-Stat 17-ZW User Instructions

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

Operating Instructions

INSTRUCTION FOR THE USER THC V E OIL BLU

Daikin Altherma Hybrid User Guide

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Model: Slimline-RF. 1 Slimline Series

Modulating clock thermostat

Operating your heating system with the Prefect PRE5701 Programable Thermostat

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Operating instruction. Remote control station WCM-FS /

INITIALIZATION / INSTALLATION

Model: Slimline-N. 1 Slimline Series

4 Wiring Brochure Wiring and

ECL Comfort 210 / 296 / 310

Operating Instructions

Model: Slimline-B. Battery Series

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

: PRT / PRT PRT / PRT-N1

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

WIRED REMOTE CONTROLLER

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Control System THETA. Operating Instructions. Room control unit RSC and RSC-OT

evolve High efficiency combi boiler Users Instructions Installation & Servicing Instructions

Combi Eco Elite Range. User s Guide and Important Warranty Information

Transcription:

USERS GUIDE Electronic Timer, 7 day LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

The national regulations and respective safety instructions are to be observed. Interferences and changes to the device will lead to cancellation of the warranty. 2

LOGIC COMBI, LOGIC COMBI E & LOGIC + COMBI Electronic Timer Instructions CONTENTS Timer controls...4 Setting the Time and Date...5 Setting the Program...6,7 Setting the Timer to run in automatic mode...8 Setting the Timer to be Continuously on...8 Setting the Timer to be Continuously off...8 The Ideal Logic Combi Timer features the following: Summer/Winter Time (GMT/BST) automatically updated 7 day timed control of central heating Simple User Interface English Language boiler fault messages and suggested corrective actions Timed pre-heat (to save energy and reduce costs) + Hours Mode Holiday Mode Setting + Hours...9 Advanced Features...10,11,12,13 3

Electronic Timer controls Display Boiler Lit Symbol +/- keys MON TUES WED THUR 1 2 3 4 FRI 5 SAT 6 SUN 7 Control Knob for program selection Indication of programmed day 0 3 6 9 12 15 18 21 24h RUN +HOURS Indication of programmed on time Next Day Key Copy Key Reset Button OK Key 4

Setting the Time and Date Note. Summer/Winter time automatically updated. 1. Turn the Control Knob to the TIME/DATE position 2. Press the and keys to change the Hours to the current time and to enter press the OK key 3. Press the and keys to change the Minutes to the current time and to enter press the OK key 4. Press the and keys to change the Year to the current year and to enter press the OK key 5. Press the and keys to change the Month to the current month and to enter press the OK key (note, January = 1) 6. Press the and keys to change the Day of the Month to the current day of the month and to enter press the OK Key 7. Turn the Control Knob to the required operating condition: RUN, Cont On or Cont Off 5

Setting the program 1. Turn the Control Knob to the PROGRAM position 2. Press the and keys to change the Hours figure for Monday s 1st On Time and to enter press the OK key 3. Press the and keys to change the Minutes figure for Monday s 1st On Time and to enter press the OK key 4. Press the and keys to change the Hours figure for Monday s 1st Off Time and to enter press the OK key 5. Press the and keys to change the Minutes figure for Monday s 1st Off Time and to enter press the OK key 6. If you do not wish to set any further times for Monday press the Next Day Key (and move to point 10). Otherwise, press the and keys to change the Hours figure for Monday s 2nd On Time and to enter press the OK key cont... 6

7. Press the and keys to change the Minutes figure for Monday s 2nd On Time and to enter press the OK key 8. Press the and keys to change the Hours figure for Monday s 2nd Off Time and to enter press the OK key 9. Press the and keys to change the Minutes figure for Monday s 2nd Off Time and to enter press the OK key Note. If you would like to set a 3rd On period then continue programming in the same manner. Otherwise press the Next Day key. 10. If you would like to have the same On and Off times for Tuesday as for Monday then press the Copy key and then the OK key. To move to Wednesday press the Next Day key, continuing in the same manner. If you would like to have different times for Tuesday, then enter them in the same manner as for Monday. When programming for Sunday is complete turn the Control Knob to the RUN position to activate the program. 11. Turn the Control Knob to the required operating condition: RUN, Cont On or Cont Off 7

Setting the Electronic timer to run in automatic mode (using the programmed on and off times) 1. Turn the Control Knob to the RUN position Setting the Electronic Timer to be Continuously on 1. Turn the Control Knob to the CONT ON position Setting the Electronic Timer to be Continuously OFF 1. Turn the Control Knob to the CONT OFF position 8

Setting + Hours Note. Use of the + Hours function will ensure the boiler operates continuously for up to 3 hours. If used during an off period, the boiler will then operate for up to 3 hours. If used during an on period less than 3 hours prior to an off period, it can extend the on time. 1. Turn the Control Knob to the + HOURS position 2. Press the and keys to set the required + Hours time and to enter press the OK key 3. Turn the Control Knob to the required operating condition: RUN, or CONT OFF 9

ADVANCED FEATURES A. HOLIDAY MODE 1. Press the key for more than 3 seconds 2. Press the and keys to change the Year to the year the holiday will start in and to enter press the OK key 3. Press the and keys to change the Month to the month the holiday will start (note, January = 1) and to enter press the OK key 4. Press the and keys to change the Day of the Month to the day of the month the holiday will start and to enter press the OK key 5. Press the and keys to set the length of the holiday and to enter press the OK key To delete a previously set holiday period, change the number of days to 0 10

ADVANCED FEATURES B. TIMED PRE-HEAT When Domestic Hot Water preheat is switched on at the boiler control the boiler will preheat during the timed on central heating periods so as to provide more efficient water delivery. This function is disabled when the preheat switch is set to off. C. RTC (Real Time Clock) Backup The electronic timer has a Real Time Clock which has a backup supply to maintain the date and time for when power is removed from the boiler. When power has been removed for more than 3 hours and is restored, it will be necessary to enter the date and time again but the programmed periods will have been retained. 11

ADVANCED FEATURES D. english language error description Boiler fault codes are identified on the display in plain English, they are also supported with a suggested corrective action to aid diagnostics. Boiler error code L1 - OVERHEAT LOCKOUT L2 - IGNITION LOCKOUT L3 - NO WATER FLOW LOCKOUT L4 - NO WATER FLOW LOCKOUT L5 - TOO MANY RESETS ON ROOM STAT Error display Corrective actions 1. FILL SYSTEM TO 1.0 BAR 2. BLEED RADIATORS 3. CHECK RADIATOR VALVES OPEN 4. RESET BOILER 1. CHECK OTHER GAS APPLIANCES WORK 2. RESET BOILER 1. FILL SYSTEM TO 1.0 BAR 2. BLEED RADIATORS 3. CHECK RADIATOR VALVES OPEN 4. RESET BOILER 1. FILL SYSTEM TO 1.0 BAR 2. BLEED RADIATORS 3. CHECK RADIATOR VALVES OPEN 4. RESET BOILER 1. RESET BOILER cont.... 12

ADVANCED FEATURES L6 - FAULT 8 F1 - LOW WATER PRESSURE F2 - FLAME LOSS F3 - FAN FAULT F4 - FLOW THERMISTOR FAULT F5 - RETURN THERMISTOR FAULT F6 - OUTSIDE SENSOR FAULT F7 - LOW MAINS VOLTAGE F9 - PCB FAULT F0 - NO WATER FLOW THERMISTOR FAULT FA - FLOW/RETURN REVERSED c0 - PCB REPLACED c2 - BOILER TYPE CARD FAULT 1. FILL SYSTEM TO 1.0 BAR 2. BLEED RADIATORS 1. CHECK OTHER GAS APPLIANCES WORK 1. CONTACT ELECTRICITY PROVIDER 1. RESET BOILER 13

14

15

November 2011 UIN 204773 A03 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal Boilers Ltd., P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration No. London 322 137.