MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

Similar documents
MODBUS RS485 TECHNICAL INSTRUCTIONS

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

recooler HP EQKR HEAT PUMP

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

Manual for the integration in BMS/GTC

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

eco PREMIUM ENERGY RECOVERY UNIT» INSTALLATION AND MAINTENANCE MANUAL

Climatix Basic reference addresses for eq Fläkt application v1.x

Built-on speed controller for GMPM plug fan with permanent magnet motor

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

Corrigo E Ventilation

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

Swegon Home Solutions CASA. R3 Smart. Installation, commissioning and maintenance instructions. R3_f_EN-t

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

TopMaster Air Handling unit. Installation instructions

SAVE VTC 200. Installation and Service. Document in original language A002

SAVE VSR 150/B. Installation and Service. Document in original language A001

eco TOP INSTALLATION AND MAINTENANCE MANUAL

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

TopMaster Air Handling unit. Technical data

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

Built-on speed controller

Climatix LON communication with POL SNVTs for eq zone application v1.x

VEKA ver C Supply air unit

Installation and User Guide

SAUTER flexotron 800 Ventilation application User Guide

SAVE VTR 500. Installation and Service. Document in original language A001

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Systemair UAB Linų st. 101, LT Ukmergė, LITHUANIA Phone: Fax:

Swegon Home Solutions CASA. W3 Smart. Installation, commissioning and maintenance instruction. W3_f_EN-t

HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

CASA. W5 Smart. Installation, commissioning and maintenance instructions. W5_d_EN-t

N M AirControl AHU. Control manual

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Fresh Air Ventilation

Fresh Air Ventilation

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

SAVE VTR 250/B. User Manual. Document in original language A001

Climatix LON communication with POL SNVTs for Twin Wheel application v1.x

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

Installation and Service

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

Heat recovery unit RDKS

VEKA Integrated Control

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

ggg Air Handling Unit RT 700/1000S-EC-RS INSTALLATION OPERATION & CONTROL PANEL MAINTENANCE & SERVICE

Technician manual

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

MicroTech Rooftop/RMC

The New Sorption Rotary Heat Exchanger

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRO greenair HP. Ventilation unit with heat recovery and integrated heat pump. Design, installation, and operation instructions

TopMaster Air Handling Unit

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

RS485 MODBUS Module 8AI

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

EU Air Handling Units with SEMCO EXCLU-SIEVE

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

Corrigo E. Second generation which contains all applications and languages

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

Carbon Monoxide Transmitter

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

AHU Plus. DX Air Handling Units

Heat pump & cooling unit in one

Database for CTS6000 MODBUS

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Installation and user's manual TAC4 DG + Modbus RTU

GLOBAL PX/RX/LP. Operation and maintenance instructions GLOBAL RX GLOBAL PX GLOBAL LP FW GLOBAL PX FW GLOBAL RX TOP GLOBAL PX TOP FW

TSEK VHR EC HEAT RECOVERY UNITS

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit.

FCCP 200: Fume-cupboard indicator and monitor

AL-KO CONTROL TECHNOLOGY THE SIMPLE ROUTE TO CONTROL

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

Technical manual MARK WTW AIRSTREAM _R01

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

L SERIES UNITS 505,191M. 4/2006 Supersedes 504,908M

L SERIES UNITS 504,908M. 10/2004 Supersedes 9/2004

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

ClimaFläkt. Chillers and condensing units

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

CLEANROOM MONITOR CR3A Network - Installation Instructions

Transcription:

Air Comfort Air Treatment Housing ventilation MODBUS RS485» Technical instructions

2 Modbus RS485 Technical instructions Description, Connections, Presentation, decimals Description RS485 has two connections, A and B. Often there is also a protective earth, ground. RS485 units are connected A to A and B to B. You may have to shift A and B in order for Modbus to work. RS485 is so called half duplex communication: Communication can only go in one direction at a time; i. e. the master will first send an enquiry and will then listen for the reply. A and B are used for both transmission and reception. Connection to control board A to terminal 70 B to terminal 69 Modbus RS485 A B GND Ground to terminal 68 See figure to the right. 1 N 70.69.68 67.66.65.64 Default settings for RS485 communication is: Com speed 19200 Parity None Data bits 8 Stop bits 1 2 L 3 N 4 L 5 N 6 L 7 N 8 L A USB 51 50 49 48 47 46 Presentation 1 bit status are presented as 0=off and 1=on 1 bit alarm are presented as 0=Normal and 1=Alarm 16 bit real values are presented in their actual value. E.g. %, Pa, l/s B 27 28 37 38 Decimals When Modbus are using a 16 bit register to handle real values, a factor must be used to have decimals. All temperature values and set points have a factor 10 and must then be divided/multiplied with 10 in the Master device. Fläkt Woods 9458GB 2016.11.23 Specifications are subject to alteration without notice

Technical instructions Modbus RS485 3 Parameter list CoilS Address R / R/W 1) Description Comment I/O Range Default Housing eco Premium eco Top VEKC 00013 R External timer 1 DI1 Yes/No 00014 R External timer 2 DI2 Yes/No 00020 R Pressure switch, supply filter 2) DI5 Yes/No 00022 R Pressure switch, extract filter 2) DI6 Yes/No 00025 R Cooker hood switch DI9 Yes/No 00033 R By-pass Damper DO5 Yes/No 00085 R Summer/Winter Mode 1=Summer 0=Winter 00094 R Fire alarm Alarm Yes/No 00095 R/W Sensor error supply temperature Alarm Yes/No 00096 R/W Sensor error out door temperature Alarm Yes/No 00097 R/W Sensor error extract/room temperature Alarm Yes/No 00098 R Sensor error frost protection Post heater. Alarm Yes/No 00099 R/W Sensor error defrost temperature Alarm Yes/No 00105 R/W Dirty filter Alarm Yes/No 00106 R/W Supply fan error Alarm Yes/No 3) 00107 R/W Extract fan error Alarm Yes/No 3) 00110 R/W Frost alarm Plate heat exchanger Alarm Yes/No 00111 R/W Rotary heat exchanger failure Alarm Yes/No 00112 R/W Filter alarm, supply air 2) Alarm Yes/No 00113 R/W Filter alarm, extract air 2) Alarm Yes/No 00114 R/W Over heating electrical heater Alarm Yes/No 00115 R Pump/ heater malfunction Alarm Yes/No 00116 R Freezing hot water battery Alarm Yes/No 00117 R/W Summary alarm cooler Alarm Yes/No 00118 R/W Pump/cooling malfunction Alarm Yes/No 00182 R/W Acknowledge all Alarm 00184 R/W Temperature alarm Alarm Yes/No 00214 R Humidity control running Yes/No 1) R = Read only, R/W = Read/Write 2) Accessory 3) Only when COP/CAV Fläkt Woods 9458GB 2016.11.23 Specifications are subject to alteration without notice

4 Modbus RS485 Technical instructions Parameter list Holding register Address R / R/W 1) Description Comment I/O Range Default Housing eco Premium eco Top VEKC 40025 R Supply air Temperature AI1 40,0 - +100,0 C 40026 R Out door air Temperature AI2 40,0 - +100,0 C 40027 R Extract/room air Temperature AI3 40,0 - +100,0 C Freezing protection post 40028 R Temperature AI4 40,0 - +100,0 C heater 40030 R Defrost air Temperature AI5 40,0 - +100,0 C 40032 R CO 2 Air quality AI6 0-2000 ppm 40035 R Humidity 1 Supply AI9 0-100 %rh 40036 R Humidity 2 Extract AI8 0-100 %rh 40037 R Pressure supply air 4) AI7 0-1000 Pa 40038 R Pressure extract air 4) AI8 0-1000 Pa 40039 R Airflow supply air 5) Calculated 0-? m 3 /h 40040 R Airflow extract air 5) Calculated 0-? m 3 /h 40041 R Fan speed, Supply air Signal AO1 0-100 % 40042 R Fan speed, Extract air Signal AO2 0-100 % 40043 R Post heating Signal AO3 0-100 % 40044 R Pre heating Signal AO4 0-100 % 40045 R Cooling 2) Signal AO5 0-100 % 40046 R Rotary heat exchanger Signal AO6 0-100 % 40049 R/W Set point Temperature 15,0-35,0 C 18 40054 R/W Min supply air temperature Temperature 15,0-35,0 C 15 40055 R/W Max supply air temperature Temperature 15,0-35,0 C 35 40073 R/W Set point CO 2 Air quality 0-2000 ppm 800 40078 R/W Supply fan speed trickle Speed low 30-100 % 30 40079 R/W Supply fan speed normal Speed normal 30-100 % 55 40080 R/W Supply fan speed boost Speed high 30-100 % 75 40081 R/W Supply fan speed cooker hood Speed 30-100 % 30 40082 R/W Supply fan speed fireplace Speed 30-100 % 100 40083 R/W Extract fan speed trickle Speed low 30-100 % 30 40084 R/W Extract fan speed normal Speed normal 30-100 % 55 40085 R/W Extract fan speed boost Speed high 30-100 % 75 40086 R/W Extract fan speed cooker hood Speed 30-100 % 100 40087 R/W Extract fan speed fireplace Speed 30-100 % 30 0 = Stop 1 = Auto 40213 R/W Main switch 0-3 2 = Manual 3 = Fire place 0 = Trickle/low 40202 R/W Fan speed 1 = Normal 0-2 2 = Boost/High 40094 R/W Setpoint air pressure 4) Supply air 0-2000 Pa 40101 R/W Setpoint air pressure 4) Exhaust air 0-2000 Pa 40095 R/W Setpoint airflow trickle 5) Supply air low 0-9999 l/s 40222 R/W Setpoint airflow normal 5) Supply air normal 0-9999 l/s 40223 R/W Setpoint airflow boost 5) Supply air high 0-9999 l/s 40102 R/W Setpoint airflow trickle 5) Exhaust air low 0-9999 l/s 40224 R/W Setpoint airflow normal 5) Exhaust air normal 0-9999 l/s 40225 R/W Setpoint airflow boost 5) Exhaust air high 0-9999 l/s 40275 R Active TemperatureSetpoint Temperature 0,5-50,5 C 40277 R/W Dirty filter alarm time 0 = Filter alarm disabled 0-600 days 180 1) R = Read only, R/W = Read/Write 2) Accessory 4) Only when COP, Constant Pressure Control 5) Only when CAV, Constant Air Volume Control Fläkt Woods 9458GB 2016.11.23 Specifications are subject to alteration without notice

FWG-Modbus Technical instructions-gb-2016.11.23 9458GB Copyright 2016 Fläkt Woods Group We bring better air to life www.flaktwoods.com Modbus 9458GB 20161123 With over a century of innovation and expertise to share with our customers, Fläkt Woods is a global leader in Air Technology products and solutions. We specialize in the design and manufacturing of a wide range of products and solutions for Air Movement, Air Treatment, Air Distribution, Air Management and Air Diffusion with focus on two major benefits Air Comfort and Fire Safety. With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer s projects. Our product brands such as SEMCO, eq, eq Prime, JM Aerofoil, Econet, Veloduct, Optivent, Optimix, Econovent and Cleanvent are well-known and trusted by customers all over the world to deliver high quality and energy efficient solutions.» To learn more about our offering and get in contact with your nearest sales representative please visit www.flaktwoods.com