Wireless ShatterPro Acoustic Sensor Installation Instructions

Similar documents
Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

1126 Series Ceiling Mount PIR Motion Detector

Pet Immune SAW PIR Motion Sensor

1125 PIR Motion Detector

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

NetworX NX-548E Receiver Installation Instructions

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Wireless Home Appliance Timer Remote Control Kit

AdvisorOne Quick Operation Guide

MODEL: A battery powered, dual technology glassbreak detector designed to work with virtually any transmitter.

FTP-1000 Touchpad/Display Installation Manual

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Campers Alert TM Portable System Hunters Alert TM Portable System

PRODUCT DIAGRAM PACKAGE CONTENTS

RADION. Transmitter. en Reference Guide

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

HSD-200Z Z-Wave Motion Sensor

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Model 17A00 Expansion Enclosure

SC-6 Six Supervised Control Module

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

PRODUCT DIAGRAM PACKAGE CONTENTS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

IDP-Zone-6 Six Zone Interface Module

Home Doorway Alert Kit

Installation and ZONES: Operation Manual. Model: ON STI-34108

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

MMF Six Zone Interface Module

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Installer Guide smart connect

Universal Fan and Light Remote Control

OPERATING MANUAL CUSTOMER SERVICE NO

Owner s Manual. PIR-1 IR Learner

Driveway Alarm INSTALLATION MANUAL.

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Honeywell Temperature & Humidity Sensor with LCD

INSTALLATION GUIDE XTLN-WIFI PANEL

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Wireless Driveway and Intruder Alert

RADION receiver SD B810 CHI. Reference Manual

180 Degree Ceiling Mounted Occupancy Sensors

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Installation and Operation Guide

Installer Guide smart connect

SMOKE & HEAT DETECTOR

COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

9000P Wireless Alarm Owner s Manual

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

1100D Wireless Receiver

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Zigbee Smoke Sensor PSG03

Wireless Outdoor Air Reset Adaptor PN:

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Panel XTO210/610/710 GPRS

1100X Wireless Receivers

SZ-PIR04N ZigBee Motion Detector Installation Guide

External Wireless Sounder

W-505 W-505 CONTROL BRACKET INSTALLATION W-505 INSTALLATION. CAUTION! Do not use with wall dimmer or rocker switch.

888 TWO WAY CAR ALARM SYSTEM USER S MANUAL

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Slim Multisensor PST02-A/B/C

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Blueair C User Manual

Concert Breeze s Manual

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm

Concord 4 Installation Guide

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Roller/Plunger. Recessed Roller Plunger With Wire Leads Series. New Improved Design! SENTROL

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Wireless External Alarm

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Slim Multisensor PST02-A/B/C

Supervised Security System Owner's Guide

WIRELESS COLOR WEATHER STATION

Digital Cooking Thermometer models / 00282

SYSTEM ENHANCEMENT MODULE

Badge Reader BR Installation Guidelines. Product Summary

Wireless Thermostat (WTS10) Keypad Operation Guide

Simon XTi Quick Operation Guide

Digital Thermometer with Ice Alert and Clock

Transcription:

Wireless ShatterPro Acoustic Sensor Installation Instructions Introduction This is the Wireless ShatterPro Acoustic Sensor Installation Instructions for models (3 V) and (9 V). The sensor is designed to detect breaking glass from framed windows in the perimeter of a building. Install the sensor on a perimeter loop armed whenever the door and window contacts are armed. Avoid 24-hour loop applications where the sensor is armed all day and all night. The false-alarm technology will be pushed to its limit in a 24- hour loop. The sensor s false-alarm immunity is best in rooms with only moderate noise. Some sounds can duplicate the points on the glassbreak pattern the sensor detects. The sensor may not consistently detect cracks in glass, or bullets which break through the glass. Glassbreak sensors should always be complemented with interior protection. Connect the sensor to a UL listed control panel, or a power supply that provides at least four hours of standby power. Use a 9-volt battery if longer life is needed in the. Mounting location The sensor must always be in direct line of sight of all windows to be protected. The sensor cannot consistently detect glass breaking around corners or in other rooms. There is no required front, back, up or down orientation. Wall mount The best wall-mount location is on the opposite wall, assuming the glass to be protected is within the sensor s range and line of sight. The adjoining wall can also be used. Ceiling mount Mount the sensor in a location that is in direct line of sight of the glass to be protected. However, since sound travels directionally out from a broken window, a position 8 ft. (2.4 m) into the room provides better detection. Use the following guidelines to determine the best mounting location: Mount the sensor at least 3.3 ft. (1 m) from the windows being protected and at least 4 ft. (1.2 m) from noise sources such as TVs, speakers, sinks, and doors. Mount the sensor in the direct line of sight of the glas s to be protected. Avoid rooms smaller than 10 x 10 ft. (3m x 3m). Avoid locations where lined, insulating, or sounddeadening drapes or closed wooden shutters are used. Mount the sensor in a suitable environment: temperature between 0 and 120 F (-18 and 50 C); and humidity between 10 and 90% noncondensing. Do not install the sensor in humid rooms. Excess moisture on the circuit board can eventually cause a short and a false alarm. Mount the sensor on a stable surface up to 25 ft. (7.6 m) from the farthest point on the glass surface. Avoid locations that expose the sensor to possible false- alarm sources such as: glass airlocks and vestibule areas; kitchens; corner mounting; residential car garages; small utility rooms; stairwells; bathrooms; and small acoustically live rooms. Coverage range The sensor is omni-directional, providing 360 coverage. Coverage is measured from the sensor to the point on the glass farthest from the sensor. The sensor can be mounted as close as 3.3 ft. (1 m) from the glass. The maximum range depends on the type of glass being protected: Armor-coated glass Mount sensor no more than 12 ft. (3.6 m) from the glass. P/N 11089 REV H OCT12 1

Plate, tempered, laminated, and wired glass Mounted on the ceiling or the opposite or adjoining wall, (Figure 1 below) maximum range is 25 ft. (7.6 m). Figure 3: Removing the sensor module Figure 1: Maximum coverage range Catch 25 ft. (7.6 m) Base 25 ft. (7.6 m) 2. Snap the sensor module unto the bracket (Figure 4 below). Installation Figure 4: Snapping the sensor module onto the bracket The sensor has two mounting options. Sensor base housing You can place the wireless transmitter inside the sensor s base housing (Figure 2 below). For some large transmitters, it will be necessary to remove the transmitter board from its housing. Figure 2: Sensor base housing 3. Run the wires to the transmitter and attach the transmitter to the bracket (Figure 5 below). Use the punched doublestick tape provided to hold the wire in the bracket s wire channel, and to hold the transmitter to the bracket. Figure 5: Attaching the transmitter to the bracket Base Lid bracket For large transmitters that do not fit into the sensor base, or for a smaller appearance with a standard size transmitter, use the transmitter bracket. To mount the sensor on the transmitter bracket, do the following: 1. To remove the sensor module from the base, depress the catch in the center of the sensor module (Figure 3 below) and rock the module up off the posts. 4. Mount the sensor/transmitter/bracket assembly. If the transmitter s mounting holes don t fit the bracket s hole pattern, you will have to mount the bracket to the wall or ceiling before attaching the transmitter. Wiring Bracket All wiring must conform to the National Electric Code (NEC) and/or local codes having jurisdiction. 2 Wireless ShatterPro Acoustic Sensor Installation Instructions

Wiring Figure 6 below shows the wiring (shares transmitter battery). The wires are: - To battery +. Figure 8: connections to the UTC Fire & Security 5816 transmitter UTC Fire & Security 3.5 V programmable - To battery -. White - Normally open (closes on alarm to battery - ). - Normally closed (to battery - ). Figure 6: w iring UTC Fire & Security 3.5 V learn mode White Figure 7 below shows the connections to the Ademco 5816 transmitter. UTC Fire & Security 3.5 V System VI Figure 7: connections to the Ademco 5816 transmitter 564503-W Ademco 5716 transmitter To connect the 583403-W to the transmitter, do the following: 564509-W 1. Program the learn mode transmitter into the MCA. 2. Connect the sensor to the transmitter as shown in Figure 8 above. Figure 8 below shows the connections to UTC Fire & Security transmitters. 3. Solder the red lead to the positive battery terminal on the underside of the circuit board. 4. Put the cover on the transmitter and put it back into the base. Snap the sensor cover in place. 5. Test with the 5709C tester. (See Testing on page 4.) Wiring Figure 9 on page 4 shows the wiring (shares transmitter battery). The wires are: - To battery +. - To battery -. White - Normally high. - Normally low. Wireless ShatterPro Acoustic Sensor Installation Instructions 3

Figure 9: w iring Figure 12 below shows the connections to the AT&T transmitter. Figure 12: connections to the AT&T transmitter AT&T transmitter White Figure 10 below shows the connections to the Ademco 5716 transmitter. Figure 10: connections to the Ademco 5716 Ademco 5716 transmitter 564509-W To connect the to the Ademco 5716 transmitter, do the following: 1. Remove the battery. 2. On SW3, set switch 6 to Off (down). On SW4, set switch 1 to ON (up). Do not use a magnet. 3. Connect loop wires (green). 4. Connect 9-V battery terminals and install the battery observing polarity. Figure 11 below shows the connections to the Honeywell 10-6506 (T-8803) transmitter. Figure 11: connections to the 10-6506 transmitter Honeywell 10-6506 (T-8803) transmitter To connect the to the AT&T transmitter, do the following: 1. Splice the white wire from the sensor to the green wire from the transmitter. 2. Connect the black wire from the sensor to the battery -. 3. Connect the red wire from the sensor to the battery +. 4. On the 12-position DIP switch, set switch 6 to OFF for CL. Set switch 7 to ON for PIR or glassbreak. If you use this transmitter inside the back box, the circuit board must be removed from the housing. You can secure it with the double-stick tape provided. For the most secure connections, it is better to solder the battery connector terminals instead of using the buddy-up clips. Testing W hite (NH) The sensor is designed to detect the breaking of framed glass mounted in an outside wall. Testing the sensor with unframed lass, broken bottles, etc., may not trip the sensor. The sensor typically does not trip to glass breaking in the middle of the room. The Pattern Recognition Technology of the sensor ignores most false alarm sounds, including glassbreak testers. To test the sensor, use test mode. Test mode disables glassbreak pattern processing in upper and lower frequencies. The sensor is then listening only for the mid-range frequencies that the UTC Fire & Security 5709C hand-held tester reproduces. It s the mid-range frequencies that determines sensor range. GND 4 Wireless ShatterPro Acoustic Sensor Installation Instructions

Test mode To put the sensor in test mode, do the following: 1. Use the 5709C handheld tester to put the sensor into test mode. Set the tester to tempered glass and hold the tester on top of the sensor. 2. Activate the tester. The sensor will alarm, then go into test mode for one minute. In test mode, the LED will blink continuously. To extend test time, fire the tester at the sensor at least once a minute. Sensor test The sensor must be in test mode (blinking). To test the sensor, do the following: 1. The tester has a different setting for each type of glass. Set the tester for tempered or laminated glass unless you are certain that all the glass to be protected is plate glass. 2. Hold the tester near the surface of the glass to be protected and aim the speaker at the sensor. Be sure the tester is at the point on the glass farthest from the detector. If closed drapes or curtains are present, hold the tester behind them (Figure 13 below). Figure 13: Testing behind curtains Room acoustics can artificially extend the range of a glassbreak sensor. The specified range of the sensor has been established for worst-case conditions. While the sensor will likely function at additional range, it may miss a minimum output break, or room acoustics may change at some future time, bringing the sensor range back into normal 20 ft. (6 m) conditions. Do not exceed the rated range of the sensor, regardless of what the tester shows. Hand clap test You can check the sensor while in normal mode, simply by clapping your hands loudly under the sensor. The LED will blink twice, but the sensor will not trip. This verifies visually that there is power to the sensor, and that the microphone and circuit board are functioning. The hand clap activation is only momentary, so there is no appreciable effect on battery life. To disable this custom test function, remove the circuit board from the housing and clip one of the wires on the LED. The LED will no longer be operational, but the sensor can still be tested using the transmitter and the control panel. Maintenance When installed and used properly, the sensor provides years of service with minimal maintenance. You should test the sensor annually to ensure proper operation. Clean the cover with a damp (water) cloth as needed to keep it free of dust and dirt. Always test the sensor after cleaning it. 3. Press the test button on the tester. The LED on the sensor should stay on for 4 seconds to indicate the glass is within detection range of the sensor. If the LED does not stay on for 4 seconds, move the sensor and retest. If the sensor will not activate within its stated range of coverage, check for battery strength in the tester. A new tester battery will likely restore range. You may need to use additional sensors to achieve adequate coverage. The sensor will automatically change from test mode to normal mode approximately one minute after it last hears the tester. In normal mode the LED does not blink unless it hears a loud sound. In normal mode, the sensor will not trip to the tester, unless the tester is held next to the sensor. Each time the sensor alarms, it also goes into test mode for one minute. Wireless ShatterPro Acoustic Sensor Installation Instructions 5

Specifications Operational voltage Current draw Alarm duration Output RF immunity Microphone 2.8 to 4.5 VDC 6 to 16 VDC 17uA typical average 23 ua typical average, 5 ma w ith LED momentarily on Four seconds Normally closed output and normally open output w ith open drain MOSFETs; 700 Ohm max. closed resistance; 10 Mohm min. open resistance. Output voltage must be less than or equal to supplied battery voltage Normally low output w ith NPN transistor and 10M pull-up resistor and normally high output w ith PNP transistor to pow er + 16 VDC max. output voltage 20 V/m, 1 MHz to 1000M Hz Omnidirectional electret FCC compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from the one where the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Recommended glass thickness Plate Tempered Wired Laminated Operating temperature Dimensions Housing material Color Wiring 3/32 to 1/4 in. (2.4 to 6.4 mm) 1/8 to 1/4 in. (3.2 to 6.4 mm) 1/4 in. (6.4 mm) 1/8 to 1/4 in. (3.2 to 6.4 mm) 14 to 120 F (-10 to 50 C) 4.25 x 3.13 x 1.70 in (108 x 80 x 43 mm) Flame-retardant ABS White 22 AWG UL stye 1061, CSA T2, color-coded w ire, passes VW-1 flame test Note: The typically w orks down to 2.1 VDC and the typically w orks down to 3.0 VDC, w hich allows most transmitters to send low battery trouble alarms. Under FCC rules, Part 15 for Class B digital devices, operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. Product ordering Product Description Wireless ShatterPro, 3-V model w ith optional bracket Wireless ShatterPro, 9-V model w ith optional bracket Accessories 5709C-W Glassbreak hand-held tester, w hite Contact information www.utcfireandsecurity.com or www.interlogix.com For customer support, see www.interlogix.com/customersupport 2012 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of United Technologies Corporation. All rights reserved. 6 Wireless ShatterPro Acoustic Sensor Installation Instructions