CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

Similar documents
CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

C13-Series Engineering Guide

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

Precision Air-Conditioning Units 60 Hz. Technical Data

Computer Room Air-Conditioning 60 Hz. Technical Data

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Environmental Control

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Precision Air-Conditioning Units 60 Hz. Technical Data

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Computer Room Air-Conditioning 60 Hz. Technical Data

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

VariCool VAV Engineering Guide

technical guide Water-Cooled Self-Contained Units

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

CoolSpot Engineering Guide

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

VertiCool Aurora Engineering Guide

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

Contents. APC NetworkAIR AFX AFX

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25)

Water-Cooled Self-Contained Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MAC N-407 Air-Cooled Chiller

GUIDE SPECIFICATIONS AQUARIUS ii

CEILAiR. Engineering Manual. Precision Air Conditioning 1 to 10 Tons (60 Hz Data) Ceiling Mounted Full line of DX & CW Systems

Advance Release September 2009

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

50TM COMBINATION HEATING/COOLING UNITS

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits

General Description. Operation

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Contents. APC NetworkAIR AFX AFX

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

50TM TFF COMBINATION HEATING/COOLING UNITS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

gforce - R-407C Air Cooled, Water/Glycol Cooled kw Dual Circuits

MACH N-407 Heat Pump Air-Cooled Chiller

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Indoor Air Handlers with Compressors MVS and MVW

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

JCseries EVAPORATIVE CONDENSER. engineering data

R-410A Air, Water/Glycol Cooled 21 through 106 kw - Dual Circuits

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Series PS6, Vertical Floor-Mount Units

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

SpaceKeeper Console (SKC)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Data Aire Series Chilled Water 7 through 50 ton

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Split System Heat Pumps

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

C-Series. Unique Solutions for All-Indoor HVAC Projects

Commercial High-Efficiency Condensing Units

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Transcription:

A e r o S y s I n c o r p o r a t e d Ceiling Mounted Units CeilMate Series 1 to 3 tons of cooling capacity Air Cooled, Self-Contained Water Cooled Glycol Cooled Remote Air Cooled Condenser Air Handler with Remote Condensing Unit Chilled Water TM AeroSys, Inc. 929 Eldridge Drive Hagerstown, Maryland, 21740 Tel: 301-620-0002 Fax: 301-620-0685 www.aerosysinc.com AeroSys, Inc. 1

AeroSys, Inc. Introduction AeroSys, Inc. is owned, managed and operated by a team with decades of experience in the air conditioning and refrigeration industry. AeroSys, Inc. is an independent equipment manufacturer, an EPA Certified Refrigerant Reclaimer and is DOT approved to re-qualify recovery cylinders. AeroSys, Inc. is comprised of two divisions: Air Conditioning Equipment Manufacturing, and Refrigerant Reclaim Services. Air Conditioning Equipment The Air Conditioning Equipment division has designed and manufactured thousands of air conditioning systems: AeroCool AeroCon CeilMate Chilled Water Air Handlers Thru-the-Wall Condensing Units & Heat Pumps Ceiling Mounted Spot Coolers Refrigerant Reclamation Services AeroSys is an EPA approved Certified Refrigerant Reclaimer under 40 CFR 82.164. AeroSys provides refrigerant reclamation and recertification services exclusively to HVAC wholesalers, and markets certified (ARI-700 ) reclaimed refrigerants under the AeroPure brand of refrigerant through our HVAC wholesale customers. AeroSys is also approved by the DOT for re-qualification of refrigerant cylinders under Title 49, Code of Federal Regulations, 49 CFR. We test, repair, repaint and re-certify refrigerant cylinders from 15# tanks up to 250# tanks. Table of Contents Page Page Features 3-5 Air Handler, Remote Condensing 10 Air Cooled, Self-contained 6 Chilled Water 11 Water Cooled 7 Electrical Data 12-13 Glycol Cooled 8 Outside Heat Exchangers, Condensing Units 14 Air Cooled, Remote Condenser 9 Dimensional, Pump Package Data 15-16 2 AeroSys, Inc.

CeilMate TM Applications These systems are designed for commercial IAQ (Indoor Air Quality) applications where cooling, heating, humidifying, dehumidifying, ventilating and air conditioning solutions are required. CeilMate TM systems are ceiling mounted air conditioners, designed for reliable 24/7 operation. Typical critical applications include: Telecommunication switch-gear rooms Data centers Clean rooms Medical MRI and CAT scan rooms Laboratories Bank and ATM kiosks Conference rooms LAN and data relay facilities Product Nomenclature C M - 24 - AS CM = CeilMate TM AS = Self-Contained Air Cooled W = Water Cooled Nominal Cooling Capacity G = Glycol Cooled (in thousands of BTU/H) AR = Remote Condenser, Air Cooled AH = Air Handling Unit CW = Chilled Water ( 2 ton self contained air cooled shown in above example) Multi-speed Blower Motor System View Oversized blower for low RPM and field flexibility Electric Box Electrode Canister Humidifier Scroll Compressor A-Frame Evaporator Thermal Expansion Valve Heater Stainless Steel Condensate Drain Pan

Cabinet The CeilMate TM is manufactured from aluminum for light weight, corrosion resistance and asthetics. The cabinet is structurally reinforced throughout to provide a stable and secure platform for the air conditioning components. The unit s evaporator section is insulated with high density, 2 lb/ft 2 thermal and acoustical insulation and sealed with self-extinguishing gasket material. Panels are fastened with quick release hardware to simplify internal access. A-Frame Coil The unit has a large face area coil to increase cooling efficiency and reduce power consumption. The copper tube, aluminum fin coil is mounted in a stainless steel condensate pan; a condensate safety switch guards against condensate overflow. Blower and Blower Motor The CeilMate TM incorporates a three speed direct drive blower motor in a draw-thru configuration for even air distribution across the coil. The large blower runs at a low rpm to minimize air noise and motor horse power consumption. The blower assembly is mounted to an internal chamber to further reduce noise levels. Electrical System The unit has a Class 2, 24VAC control circuit, all necessary contactors, fuses and/or circuit breakers for full operation. 24 VAC field connections and high voltage connections are provided through separate termination blocks in the electric box. Ducted System The system is available in three air patterns: ducted return and supply, ducted return and free air discharge, or free return and ducted discharge. Free air is through the bottom of the unit the supply or return air pattern. Standard Features 4 AeroSys, Inc. Refrigeration System The CeilMate TM system includes all necessary components for safe and reliable operation. Easily accessible components include: thermal expansion valve, sight glass with moisture indicator, high and low pressure safety switches, refrigeration service access ports, and refrigerant drier/strainer. Self-contained air cooled, water and glycol cooled units are evacuated and shipped with a full refrigerant charge. Split systems include a refrigerant pump-down solenoid to prevent liquid slugging. Units are evacuated and charged with dry nitrogen. Compressor All D.X. systems, 1-1 / 2 ton and larger (CM- 18 thru CM-36) incorporate scroll compressors for high reliability, high efficiency and low noise. CM-12, one refrigerant ton, systems include the latest generation in reciprocating compressors. Compressors are mounted on vibration isolators to minimize noise transmission to the cabinet. Chilled Water Units Chilled water CeilMate TM systems are completely piped, wired and factory tested. Units include a 24 volt motorized zone valve for chilled water control. Water Regulating Valves All Water and Glycol cooled systems are delivered with factory installed, tested and adjusted 2-way water regulating valves, rated for 150 psi w.w.p, to maintain proper refrigerant head pressure. Optional Features Ultra Violet Sterilization Light The unit incorporates a high intensity UV light to sterilize the air passing through the coil. As airborne mold bacteria are exposed to the UV light they are killed, preventing them from depositing active contaminants on the coil surface, the condensate pan and other internal surfaces. As the air is changed several times in the conditioned room, the contaminants are constantly being reduced in number.

Electrode Canister Humidifier Integrated with the CeilStat, the humidifier provides humidification to your facility. An optional electrode canister is available providing state-of-the-art humidity control. The humidifier senses cylinder current draw, automatically flushing and filling the cylinder to control the mineral content of the water and humidity output The output is field adjustable from 1 to 5 lbs/hr. A Change Cylinder light alerts service personel when the humidifier output requires service. Electric Heat/Reheat Electric reheat is designed to offset the cooling effect of the dehumidification cycle; electric heat provides resistance heat regardless of the dehumidification cycle. The unit incorporates a factory installed, wired and tested nichrome wire heater. The heater has low voltage thermal safety cutouts, one pilot duty automatic resettable and a second power line fuselink (overtemperature) safety device for each bank of heat. Condensate Pump options: External: The condensate pump is factory mounted, wired and integrated into the moisture removal system of the unit. In the event the condensate pump can not remove the water fast enough, an emergency shut-off switch locks out the compressor and humidifier until the condensate pump has emptied its sump. Internal: The condensate pump is factory mounted in the stainless steel condensate pan, wired and integrated into the moisture removal system of the unit. In the event the condensate pump can not remove the water fast enough, an emergency shut-off switch locks out the compressor and humidifier until the condensate pump has emptied its sump. Optional Features CeilStat I Electronic Thermostat/Humidistat The CeilStat I temperature and humidity controller incorporates temperature and humidity control in an attractive, wall mounted unit. This line powered, backlit system incorporates several salient features: * Manual override * 7 day programming * Programmable Fan * Adjustable Differential * Compressor Short Cycle Protection * Air Filter Monitor * 4 Hour reserve for settings * Status Indicators * Humidification in heat or air circulation modes * Hidden Service Level * Condensation Control CeilStat II Internet Accessible Thermostat/Humidistat The CeilStat II temperature and humidity controller incorporates temperature and humidity control in an attractive, wall mounted unit. This line powered, backlit system incorporates several salient features: * Internet Connectivity for monitoring, management and configuration capability (requires secure customer internet access) * Easy installation * Backlit Graphic LCD display * EnergyStar Compliant * FCC Class B Compliant * Failsafe Temperature Switch * Adjustable Differential * Compressor Short Cycle Protection * E-Mail or Text Messaging Fault reporting * Status Indicators * Independent humidify and dehumidify control in cooling and heating modes * Hidden Service Level Alarms * Air Filter Monitor * Over/Under Temperature Alarm * High Humidity alarm * Customer selected contact closure High Pressure Glycol/Water Systems Water cooled systems are available with factory installed, tested and adjusted 2- way water regulating valves, rated for 350 psi w.w.p, to maintain proper refrigerant head pressure. 500 psi valves are also available. AeroSys, Inc. 5

Air Cooled, Self-Contained Systems Model CM-( )-AS (12) (18) (24) (30) (36) Cooling Capacity, BTU/H 80 o F DB/67 o F WB, 50%RH Total Capacity 15,660 19,970 24,090 29,890 36,730 Sensible Capacity 11,940 16,300 18,700 24,870 27,990 75 o F DB/62.5 o F WB, 50%RH Total Capacity 14,530 18,430 22,290 27,790 31,220 Sensible Capacity 11,860 16,010 18,490 24,520 27,550 72 o F DB/60 o F WB, 50%RH Total Capacity 13,770 17,650 21,250 26,680 29,550 Sensible Capacity 11,560 15,640 18,100 24,060 26,840 Heating Capacity, Nichrome wire element, optional Heater kw @220/1/60 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw BTU/H, @220/1/60 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge 500 750 800 1,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm 185 234 250 324 378 Condenser Blower, DWDI, Direct Drive, 3 speed Motor Horsepower 1/4 1/2 1/2 1/2 1/2 CFM @0.3 esp 750 1,000 1,200 1,400 1,600 Condenser Coil, Aluminum Fin, Copper Tube Head Pressure Control (std) ------ ------ Speed Control ------ ------ Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Total Heat of Rejection (Btu/h) 20,100 25,750 31,160 38,980 43,800 Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Physical Data Dimensions-- see page 15 for details Approximate weight 215 220 245 260 270 6 AeroSys, Inc.

Water Cooled Systems Model CM-( )-W (12) (18) (24) (30) (36) Cooling Capacity, BTU/H 80 o F DB/67 o F WB, 50%RH Total Capacity 18,090 21,850 26,520 33,260 38,380 Sensible Capacity 13,030 17,160 19,910 26,520 30,200 75 o F DB/62.5 o F WB, 50%RH Total Capacity 16,600 20,180 24,450 31,230 36,010 Sensible Capacity 12,810 16,870 19,530 26,290 29,950 72 o F DB/60 o F WB, 50%RH Total Capacity 15,530 18,980 23,010 29,380 33,880 Sensible Capacity 12,430 16,390 19,000 25,540 29,110 Heating Capacity, Nichrome wire element, optional Heater kw @220/1/60 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw BTU/H, @220/1/60 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge 500 750 800 1,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm 185 234 250 324 378 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Water Cooled Condenser, Coaxial type, with 2 way water regulating valve GPM @ 85 o F EWT 3.5 4.7 5.6 7.5 8.6 Unit Pressure Drop (ft of H 2 O) 2.5 4.6 6.5 11.5 15.1 Total Heat of Rejection (@75/62.5) 19,700 23,980 29,150 37,270 43,420 Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Condenser In/Out, Sweat OD 1/2 1/2 1/2 3/4 3/4 Physical Data Dimensions-- see page 15 for details Approximate weight 195 200 225 245 250 AeroSys, Inc. 7

Glycol Cooled Systems Model CM-( )-G (12) (18) (24) (30) (36) Cooling Capacity, BTU/H 80 o F DB/67 o F WB, 50%RH Total Capacity 15,850 19,800 23,930 30,280 35,550 Sensible Capacity 12,160 16,470 18,840 25,390 29,340 75 o F DB/62.5 o F WB, 50%RH Total Capacity 14,350 18,020 22,340 28,500 33,340 Sensible Capacity 11,860 15,910 18,630 25,110 28,860 72 o F DB/60 o F WB, 50%RH Total Capacity 13,280 17,610 20,990 26,780 31,760 Sensible Capacity 11,410 15,730 18,090 24,250 28,150 Heating Capacity, Nichrome wire element, optional Heater kw @220/1/60 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw BTU/H, @220/1/60 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge 500 750 800 1,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm 185 234 250 324 378 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Glycol Cooled Condenser, Coaxial type, with 2 way glycol regulating valve GPM @ 105 o F EWT 3.5 4.0 5.3 6.9 8.8 Unit Pressure Drop (ft of H 2 O) 5.7 6.4 6.8 9.3 15.6 Total Heat of Rejection (@75/62.5) 17,540 22,790 28,230 36,080 42,470 Fluid Cooler size, 95 o F Ambient FC-012 FC-018 FC-024 FC-030 FC-036 Pump Package--See pages 15 and 16 for dimensional information and pump selection Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Condenser In/Out, Sweat OD 1/2 1/2 1/2 3/4 3/4 Physical Data Dimensions-- see page 15 for details Approximate weight 195 200 225 245 250 8 AeroSys, Inc.

Remote Air Cooled Systems Model CM-( )-AR (12) (18) (24) (30) (36) Cooling Capacity, BTU/H @ 125 o F Condensing 80 o F DB/67 o F WB, 50%RH Total Capacity 21,200 26,400 31,600 38,700 41,300 Sensible Capacity 14,400 18,900 21,900 28,400 31,000 75 o F DB/62.5 o F WB, 50%RH Total Capacity 16,100 20,100 23,900 29,300 31,400 Sensible Capacity 12,600 16,800 19,300 25,200 27,700 72 o F DB/60 o F WB, 50%RH Total Capacity 12,800 17,500 20,200 25,700 27,800 Sensible Capacity 11,200 15,700 17,800 23,700 26,000 Heating Capacity, Nichrome wire element, optional Heater kw @220/1/60 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw BTU/H, @220/1/60 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge 500 750 800 1,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm 185 234 250 324 378 Remote Air Cooled Condenser, 95 o F Ambient, fan cycling control standard Model (see page 14 for details) ACC-018 ACC-023 ACC-032 ACC-032 ACC-049 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Total Heat of Rejection (Btu/h) 17,500 25,750 31,160 38,980 43,800 Connection Sizes Condensate drain, PVC 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet, 1/4 copper 1/4 1/4 1/4 1/4 1/4 Liquid line, Sweat OD 1/2 1/2 1/2 3/4 3/4 Hot Gas line, Sweat OD 3/8 3/8 3/8 3/8 3/8 Physical Data Dimensions-- see page 15 for details Approximate weight 175 180 205 210 220 AeroSys, Inc. 9

Air Handler for Remote Condensing Systems Model CM-( )-AH (12) (18) (24) (30) (36) Cooling Capacity, BTU/H @ 45 o F Suction 80 o F DB/67 o F WB, 50%RH Total Capacity 21,200 26,400 31,600 38,700 41,300 Sensible Capacity 14,400 18,900 21,900 28,400 31,000 75 o F DB/62.5 o F WB, 50%RH Total Capacity 16,100 20,100 23,900 29,300 31,400 Sensible Capacity 12,600 16,800 19,300 25,200 27,700 72 o F DB/60 o F WB, 50%RH Total Capacity 12,800 17,500 20,200 25,700 27,800 Sensible Capacity 11,200 15,700 17,800 23,700 26,000 Heating Capacity, Nichrome wire element, optional Heater kw @220/1/60 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw BTU/H, @220/1/60 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge 500 750 800 1,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 2/2.7 2/3.2 2/3.2 2/3.7 2/3.7 Face Velocity, fpm 185 234 250 324 378 Remote Air Cooled Condensing Unit, 95 o F Ambient, fan cycling control standard Model (see page 14 for details) THDC-12 THDC-18 THDC-24 THDC-30 THDC-036 Compressor, Heat pump duty rated, R-22 system Nominal Horsepower 1 Hp 1.5 Hp 2 Hp 2.5 Hp 3.0 Hp Compressor type Recip. Scroll Scroll Scroll Scroll Total Heat of Rejection (Btu/h) 17,500 25,750 31,160 38,980 43,800 Connection Sizes Condensate drain 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet 1/4 1/4 1/4 1/4 1/4 Liquid line connection, OD 1/2 1/2 1/2 3/4 3/4 Suction line connection, OD 7/8 7/8 7/8 7/8 7/8 Physical Data Dimensions-- see page 15 for details Approximate weight, lbs. 125 125 150 155 155 10 AeroSys, Inc.

Chilled Water Air Handler Model CM-( )-CW (12) (18) (24) (30) (36) Cooling Capacity, BTU/H @ 45 o F Entering Water Temperature 80 o F DB/67 o F WB, 50%RH Total Capacity 15,500 22,040 25,200 33,200 42,600 Sensible Capacity 12,100 17,180 19,400 27,000 33,200 75 o F DB/62.5 o F WB, 50%RH Total Capacity 12,500 17,600 20,100 27,000 34,000 Sensible Capacity 11,100 16,800 17,800 24,800 30,400 72 o F DB/60 o F WB, 50%RH Total Capacity 10,120 14,260 16,280 21,870 27,610 Sensible Capacity 9,100 13,770 15,410 20,340 24,930 GPM Rating (point flow water rate) 2.5 gpm 4.0 gpm 4.5 gpm 5.0 gpm 8.0 gpm Heating Capacity, BTU/H, 60 o F EAT, EWT= Entering Water Temperature, LAT= Leaving Air Temperature BTU/H @120 o F EWT ( o F LAT) 22,700 (101 o F) 28,800 (98 o F) 30,600 (95 o F) 49,200 (98 o F) 52,400 (94 o F) GPM Rating 1.8 gpm 2.3 gpm 2.0 gpm 3.6 gpm 3.6 gpm BTU/H @150 o F EWT ( o F LAT) 34,400 (123 o F) 43,600 (117 o F) 46,500 (113 o F) 74,800 (117 o F) 79,600 (112 o F) GPM Rating 1.8 gpm 2.3 gpm 2.0 gpm 3.6 gpm 3.6 gpm BTU/H @180 o F EWT ( o F LAT) 41,070 (136 o F) 58,700 (137 o F) 62,500 (131 o F) 100,600(136 o F)107,200 (130 o F) GPM Rating 1.6 gpm 2.3 gpm 2.0 gpm 3.6 gpm 3.6 gpm Heating Capacity, Nichrome wire element, optional Heater kw @220/1/60 3.0 kw 5.0 kw 5.0 kw 7.0 kw 7.0 kw BTU/H, @220/1/60 10,760 17,500 17,570 24,540 24,690 Evaporator Blower, DWDI, Direct Drive, 3 speed CFM, Free Discharge 500 750 800 1,200 1,400 Motor Horsepower 1/8 1/6 1/4 1/2 1/2 Filter, 1 deep throw away, Qty. 1 20x20 20x20 20x20 20x20 20x20 Humidification, Electrode Canister Humidifier with adjustable cycling output, optional Steam Output, lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr 1-5 lbs/hr Power consumption 1.8 kw 1.8 kw 1.8 kw 1.8 kw 1.8 kw Evaporator Coil, Aluminum Fin, Copper Tube, A-frame design Rows/Face Area (ft 2 ) 3/1.5 3/1.5 3/2.0 3/3.0 3/3.0 Face Velocity, fpm 333 500 400 400 467 Connection Sizes Condensate drain 3/4 3/4 3/4 3/4 3/4 Humidifier Inlet 1/4 1/4 1/4 1/4 1/4 Chilled water connection, OD 1/2 3/4 3/4 3/4 3/4 Physical Data Dimensions-- see page 15 for details Approximate weight, lbs. 125 125 150 155 155 AeroSys, Inc. 11

Electrical Data Power Consumption at 208/1/60 Model (12) (18) (24) (30) (36) Air Cooled Self Contained, CM-( )-AS series Cooling only Full Load Amps 10.1 11.7 13.6 18.0 19.8 Minimum Circuit Amps 14.5 17.5 19.8 24.9 28.0 Maximum Overcurrent Protection 20 25 30 35 40 Heat/Reheat option only (in dehumidification mode) Full Load Amps 22.3 36.1 38.0 42.3 44.2 Minimum Circuit Amps 26.6 41.9 44.2 49.3 52.4 Maximum Overcurrent Protection 35 50 55 60 60 Humidification option only (and cooling mode) Full Load Amps 18.2 19.8 21.7 26.1 27.9 Minimum Circuit Amps 22.6 25.6 28.0 33.0 36.1 Maximum Overcurrent Protection 30 35 35 45 50 Heat/Reheat, Humidification options combined (no cooling) Full Load Amps 21.8 34.0 34.7 36.5 36.5 Minimum Circuit Amps 22.2 34.4 35.3 37.5 37.5 Maximum Overcurrent Protection 25 35 35 40 40 Water Cooled, CM-( )-W series Cool only Full Load Amps 7.5 7.0 8.8 12.9 14.6 Minimum Circuit Amps 12.3 13.5 15.8 20.9 24.0 Maximum Overcurrent Protection 20 20 25 35 40 Heat/Reheat option only (in dehumidification mode) Full Load Amps 19.7 31.3 33.2 37.3 39.0 Minimum Circuit Amps 24.4 37.9 40.2 45.3 48.4 Maximum Overcurrent Protection 30 45 50 60 60 Humidification option only (and cooling mode) Full Load Amps 15.6 15.1 16.9 21.0 22.7 Minimum Circuit Amps 20.4 21.6 24.0 29.0 32.1 Maximum Overcurrent Protection 30 30 35 40 50 Heat/Reheat, Humidification options combined (no cooling) Full Load Amps 21.8 34.0 34.7 36.5 36.5 Minimum Circuit Amps 22.2 34.4 35.3 37.5 37.5 Maximum Overcurrent Protection 25 35 35 40 40 Glycol Cooled, CM-( )-G series Cool only Full Load Amps 8.2 8.6 10.5 15.2 17.3 Minimum Circuit Amps 12.3 13.5 15.8 20.9 24.0 Maximum Overcurrent Protection 20 20 25 35 40 Heat/Reheat option only (in dehumidification mode) Full Load Amps 20.4 32.9 34.9 39.6 41.7 Minimum Circuit Amps 24.4 37.9 40.2 45.3 48.4 Maximum Overcurrent Protection 30 45 50 60 60 Humidification option only (and cooling mode) Full Load Amps 16.3 16.7 18.6 23.3 25.4 Minimum Circuit Amps 20.4 21.6 24.0 29.0 32.1 Maximum Overcurrent Protection 30 30 35 40 50 Heat/Reheat, Humidification options combined (no cooling) Full Load Amps 21.8 34.0 34.7 36.5 36.5 Minimum Circuit Amps 22.2 34.4 35.3 37.5 37.5 Maximum Overcurrent Protection 25 35 35 40 40 12 AeroSys, Inc.

Electrical Data Power Consumption at 208/1/60 Model (12) (18) (24) (30) (36) Air Cooled Remote Condenser, CM-( )-AR series Cool only Full Load Amps 7.9 7.7 9.6 14.0 15.8 Minimum Circuit Amps 12.3 13.5 15.8 20.9 24.0 Maximum Overcurrent Protection 20 20 25 35 40 Heat/Reheat option only (in dehumidification mode) Full Load Amps 20.1 32.1 34.0 38.3 40.2 Minimum Circuit Amps 24.4 37.9 40.2 45.3 48.4 Maximum Overcurrent Protection 30 45 50 60 60 Humidification option only (and cooling mode) Full Load Amps 16.0 15.8 17.7 22.1 23.9 Minimum Circuit Amps 20.4 21.6 24.0 29.0 32.1 Maximum Overcurrent Protection 30 30 35 40 50 Heat/Reheat, Humidification options combined (no cooling) Full Load Amps 21.8 34.0 34.7 36.5 36.5 Minimum Circuit Amps 22.2 34.4 35.3 37.5 37.5 Maximum Overcurrent Protection 25 35 35 40 40 Air Handler with Remote Condensing Unit, CM-( )-AH series Cool only Full Load Amps 1.5 1.5 2.2 4.0 4.0 Minimum Circuit Amps 1.9 1.9 2.8 5.0 5.0 Maximum Overcurrent Protection 5 5 6 8 8 Heat/Reheat option only (in dehumidification mode) Full Load Amps 13.7 21.8 26.6 28.4 28.4 Minimum Circuit Amps 14.1 22.2 27.1 29.4 29.4 Maximum Overcurrent Protection 15 25 30 35 35 Humidification option only (and cooling mode) Full Load Amps 9.6 9.6 10.3 12.1 12.1 Minimum Circuit Amps 10.0 10.0 10.9 13.1 13.1 Maximum Overcurrent Protection 10 10 15 15 15 Heat/Reheat, Humidification options combined (no cooling) Full Load Amps 21.8 34.0 34.7 36.5 36.5 Minimum Circuit Amps 22.2 34.4 35.3 37.5 37.5 Maximum Overcurrent Protection 25 35 35 40 40 Chilled Water Air Handler, CM-( )-CW series Cool only Full Load Amps 1.5 1.5 2.2 4.0 4.0 Minimum Circuit Amps 1.9 1.9 2.8 5.0 5.0 Maximum Overcurrent Protection 5 5 6 8 8 Heat/Reheat option only (in dehumidification mode) Full Load Amps 13.7 21.8 26.6 28.4 28.4 Minimum Circuit Amps 14.1 22.2 27.1 29.4 29.4 Maximum Overcurrent Protection 15 25 30 35 35 Humidification option only (and cooling mode) Full Load Amps 9.6 9.6 10.3 12.1 12.1 Minimum Circuit Amps 10.0 10.0 10.9 13.1 13.1 Maximum Overcurrent Protection 10 10 15 15 15 Heat/Reheat, Humidification options combined (no cooling) Full Load Amps 21.8 34.0 34.7 36.5 36.5 Minimum Circuit Amps 22.2 34.4 35.3 37.5 37.5 Maximum Overcurrent Protection 25 35 35 40 40 AeroSys, Inc. 13

Outside Heat Exchangers 9 / 16 Lifting A 15 in Header Electric Box 9 / 16 Mounting E F Mounting Legs (4) Model Motor Data (208/1/60) Ref. Charge THR @ o F ITD # @ fan dia. Hp Amps R-22 (lbs.) 20 o F 25 o F 30 o F ACC-014 1@ 18 in 1/3 3.2 0.45 13.5 16.8 20.2 ACC-018 1@ 18 in 1/3 3.2 0.45 17.8 22.3 26.7 ACC-023 1@ 18 in 1/3 3.2 0.90 22.8 28.6 34.3 ACC-032 1@ 22 in 1/3 3.2 1.20 31.2 39.0 46.8 ACC-049 1@ 22 in 1/3 3.2 1.95 48.9 60.5 72.5 Model Cabinet Dimensions Weight Connections A B C E F Net Shipping Liquid/Gas ACC-014 16-1 / 4 28 25-9 / 16 26-5 26-13 / 16 78 97 7/8 OD ACC-018 16-1 / 4 28 25-9 / 16 26-5 26-13 / 16 80 99 7/8 OD ACC-023 16-1 / 4 28 25-9 / 16 26-5 26-13 / 16 86 105 7/8 OD ACC-032 18-1 33 30-9 / 16 31-5 31-13 / 16 107 128 7/8 OD ACC-049 18-1 33 30-9 / 16 31-5 31-13 / 16 116 137 7/8 OD Remote Condensing Units BTU/H s Electrical Data Dimensions Weight Connections FLA/MCA/MOP H x W x D (in) net/ship (lb) Liquid/Suction R (Runt) Series THDC-12-R 12,500 10.2/17.2/25 23x29 1 / 2 70/75 3 / 3 / 4 THDC-18-R 20,200 10/17.2/25 23x29 1 / 2 75/81 3 / 3 / 4 THDC-24-R 25,200 12/19.7/30 23x29 1 / 2 79/85 3 / 3 / 4 THDC-30-R 30,000 15.9/24.7/35 23x29 1 / 2 91/102 3 / 3 / 4 THDC-36-R 35,300 17.7/28.3/45 23x29 1 / 2 70/75 3 / 3 / 4 S (Short) Series THDC-12-S 12,500 10.2/17.2/25 28 5 x26 70/75 3 / 3 / 4 THDC-18-S 20,300 10/17.2/25 28 5 x26 75/81 3 / 3 / 4 THDC-24-S 25,500 12/19.7/30 28 5 x26 79/85 3 / 3 / 4 THDC-30-S 30,000 15.9/24.7/35 28 5 x26 91/102 3 / 3 / 4 THDC-36-S 35,400 17.7/28.3/45 28 5 x26 70/75 3 / 3 / 4 T (Tall) Series THDC-12-T 12,500 10.2/17.2/25 32x23 3 / 4 70/75 3 / 3 / 4 THDC-18-T 19,900 10/17.2/25 32x23 3 / 4 75/81 3 / 3 / 4 THDC-24-T 25,400 12/19.7/30 32x23 3 / 4 79/85 3 / 3 / 4 THDC-30-T 30,000 15.9/24.7/35 32x23 3 / 4 91/102 3 / 3 / 4 THDC-36-T 35,900 17.7/28.3/45 32x23 3 / 4 70/75 3 / 3 / 4 ARI 210/240 conditions 14 AeroSys, Inc.

Dimensional Data Self-Contained Air Cooled CM-( )AS Series Units 51 1 / 2 23 7 17 21 1 10 1 / 4 8 1 / 4 45 1 22 47 3 / 4 CM-( )-W, G, CW, AR, AH Series Units 51 1 / 2 20 3 23 7 45 1 47 3 / 4 Field Connection Area for Condenser and Chilled Water Pipes DUCTED Self-Contained Air Cooled CM-( )AS Series Units 14.1 6.9 10.3 10.0 8.3 16.5 AeroSys, Inc.

Head (ft) 120 5.00 in 100 80 60 3.30 in 40 3.25 in 31 42 PA_-005 (1/2 HP) 1.25x1x5 @ 3500 rpm 20 0.5 hp 0.333 hp 0.25 hp System 0 0 16 32 48 64 80 Ethylene Glycol: 40%, sg = 1.06 50 57 61 63 Pump Package Performance Curves 64 63 1 hp 0.75 hp 61 57 1.5 hp 50 2 hp 3 hp Flow (usgpm) Head (ft) 120 5.00 in 100 80 60 3.25 in 40 20 3.56 in 31 42 50 57 61 0.333 hp 0.25 hp System 0 0 16 32 48 64 80 Ethylene Glycol: 40%, sg = 1.06 PA_-007 (3/4 HP) 1.25x1x5 @ 3500 rpm 63 0.5 hp 64 63 1 hp 61 0.75 hp 57 1.5 hp 50 2 hp 3 hp Flow (usgpm) Head (ft) 120 5.00 in 100 80 60 3.88 in 3.25 in 40 20 31 42 PA_-010 (1 HP) 1.25x1x5 @ 3500 rpm 50 57 61 0.333 hp System 0.25 hp 0 0 16 32 48 64 80 63 64 0.5 hp 63 61 1 hp 0.75 hp 57 1.5 hp 50 2 hp 3 hp Ethylene Glycol: 40%, sg = 1.06 Flow (usgpm) Single and Dual Pump Packages 5" ACCESS PANEL (Pumps & Electrical) 24" Pump Outlet (Knockouts) Pump Inlet (Knockouts) 36" 20" 3/4" 38" FRONT / LEFT / TOP VIEW Other AeroSys Products AeroCon THDC Series contrifugal condensing in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. REAR / RIGHT / TOP VIEW AeroCon THHP Series heat pumps in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. AeroCool DDX Series D.X. air handlers in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. AeroCon Centrifugal condensing units from 3 to 5 tons AeroCool DCW Series chilled water air handlers in sizes from 1-1 / 2 ton to 2-1 / 2 ton capacities. AeroPure Refrigerants, certified to ARI 700. Accepted for Use City of NY Dept. of Bldgs MEA-371-05-E Represented by: Specifications are subject to change without notice 16 AeroSys, Inc. Form CM-1208 Rev.0