Electric Riva Flame-Effect Cassette Fire

Similar documents
Dovre 280 or 425 Electric

INSTALLATION & USER INSTRUCTIONS

CL Electric Range. Freestanding Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Radiance Electric Range

Riva2 670 Electric. Instructions for Use, Installation & Servicing. For use in AU & NZ (Australia & New Zealand). IMPORTANT

Radiance Electric Range

Trento. Modular Suite. For use with the Skope Electric Outset Range. Instructions for Use and Installation

INSTALLATION & USER INSTRUCTIONS

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Studio Electric Range

INSTALLATION & USER INSTRUCTIONS

Imperial Electric Fires

Installation Instructions & Operating Manual IMPORTANT

Contact Details. Please note that some of the contact details on this PDF document may not be current.

26 FIREBOX EN RU UA FR

Electric Stove Range

INSTALLATION & USER INSTRUCTIONS

Conversion of Gazco Upgradable Controls to Battery Remote Control

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

INSTALLATION & USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

2kW ELECTRIC HEATER WITH REMOTE CONTROL NEBRASKA NEBRASKA

SP16. 08/50740/1 (UK) - Issue 1

Contact Details. Please note that some of the contact details on this PDF document may not be current.

INSTALLATION & USER INSTRUCTIONS

2kw Remote Control Electric Fire. User and Installation Instructions

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

JUNEAU JUN. 08/51193/0 Issue 0

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

E-MAL1 E-AW1 E-NEO. Malvern Electric Astwood Electric NEO Electric T E C H N I C A L & U S E R M A N U A L

IMPORTANT SAFETY INFORMATION:

Imperial Electric Fires

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

FIGARO. 08/52543/0 (UK) Issue 1

INSTALLATION & USER INSTRUCTIONS

Owner s Manual. Revillusion Suites Osbourne Revillusion Suite OSB20-AU Windlesham Revillusion Suite WDS20-AU Strata Revillusion Suite STA20-AU

INSTALLATION & USER INSTRUCTIONS

Use & Care Manual Inset Electric Fires

Installation and Maintenance Instructions XPG170 Electric Fires

Use & Care Manual Contemporary Electric Fires

Charlotte CRT20AB, Charlotte CRT20BR & Brookline BKL20

ECOLEC PANEL HEATERS GENERAL NOTES.

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

DANVILLE DNV20AB, DNV20BR, DNV20BL & DNV20CH

Skope Electric Range

Yeoman CL7 Inset. Instructions for Use and Installation. For use with Gazco Logic HE. For use in GB, IE (Great Britain and Republic of Ireland)

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

Skope Electric Range

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

16 XD Mk2 Inset Electric Fire

155mm. 820mm. 540mm E D. 940mm. 600mm

OPTIMYST WALL ENGINE OMWFC20 RTOPW20 PEM20

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

16 Ultiflame Inset Electric Fire

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Chimney Renovation Kit

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

Oil Panel Heater Instructions for Use

3KW ELECTRIC FAN HEATER

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

INSTALLATION & USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Gallery Electric Fireplaces

Skope Electric Range

OPERATING INSTRUCTION MANUAL

Installation & User Instructions:

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

INSTALLER AND OWNER GUIDE

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

OPERATING INSTRUCTIONS

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

EH " (40cm) Remote Control Wall Fan

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

ELECTRIC CONVECTOR HEATER. This product is only suitable for well insulated spaces or occasional use.

THIS INSTRUCTION BOOKLET MUST BE LEFT WITH THE USER

Mobile Air Conditioner Instruction Manual Model TC-N9KM

IMPORTANT SAFETY INFORMATION:

Use & Care Manual Electric Portrait with remote control DBL-2000-DD5

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

DRY:SOON TOWEL WARMER

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

Radiant Heater. Instruction Manual QH-200 N13275

IMPORTANT SAFETY INFORMATION:

900W OIL FILLED RADIATOR

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

MICATHERMIC PANEL HEATER

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

Transcription:

Electric Riva Flame-Effect Cassette Fire Installation and User Instructions For use in GB, IE (Great Britain and Eire) This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance will require modification. Contact Gazco for further information. IMPORTANT For use with 230v 50Hz electricity supply only. Please read these instructions carefully before installation and keep them in a safe place. They will be needed when maintenance or servicing is required. THIS APPLIANCE MUST BE EARTHED PR0851 Issue 3 (May 2007)

USER INSTRUCTIONS 1.1 Do not locate this fire immediately below a fixed socket outlet. 1.2 Do not use this fire in the immediate surroundings of a bath, shower or swimming pool or any other area where the fire would come into contact with water. 1.3 WARNING: Do not allow the fire to be covered or let the air inlet/outlet become obstructed as the appliance may overheat. 1.4 This fire must stand on a level firm surface. Do not stand the fire on a carpet. Ensure that furniture, curtains etc. are positioned no closer than 1 metre 1.5 When the fire has been installed, the position of the plug must be accessible. 1.6 Where the electricity supply cable has to pass through a fireplace, stone surround etc. ensure suitable rubber bushes are fitted at possible wear points. 1.7 If installed in an open fireplace, blank off the chimney to reduce the risk of a back draught, which could cause the safety cut-out to operate. 1.8 If the electricity supply cable is damaged do not use the appliance until it has been replaced. For safety reasons the replacement has to be carried out by Gazco, or a Gazco service agent or a similarly competent electrician. 2.1 GENERAL 1. IMPORTANT INFORMATION 2. OPERATING INSTRUCTIONS Your fire is remote controlled and can be operated by the hand held infra red handset or by the buttons on the appliance. c) Push the ON/OFF button to turn on the fire effect. A beep will be heard to confirm this action. d) Push the flame button to change the flame effect and fuel bed. Continue pressing the button to cycle through the four effects, until the desired one is reached. These are: Effect e) Push the LOW button to provide half heat output, i.e. 1kW. Press again to turn low setting off. f) Push the HIGH button to provide full heat output i.e. 2kW. Press once again to turn the high setting off, or press LOW to turn the low setting on. g) Push the OFF button at any time to turn the fire off. h) The cassette fire should be turned off via the on/off switch when the heat or the light effect is not required. 2.4 PLEASE NOTE Description 1 Pulsing fuel bed 2 Slow pulsing fuel bed 3 Low Flame 4 Flickering fuel bed a) The glass fibre log moulding may give off a slight smell when first used. This is normal and should disappear after a day or two. b) The fire is fitted with a thermal safety cutout, which operates if the appliance overheats. Should this happen, unplug and allow the heater to cool for 5 minutes. Check the air inlets/outlets for any obstruction. Plug in, switch on the fire and the cutout will re-set. The appliance should function correctly again but if this is not the case, unplug once more and have the fire checked by a competent electrician. 2.2 LOCATION OF CONTROLS The appliance button controls are located on the bottom right-hand side of the fire. These are positioned behind the frames, which hinges when pulled from this position. 2.3 OPERATION a) There is an on-off switch mounted on the right of the fire behind the door on the frame. This needs to be turned on before the remote control will operate. The lights in the fire will flash once to indicate that the fire is ready to use. b) Ensure that the handset batteries are new and are inserted correctly. (When replacing the batteries, ensure the worn out batteries are disposed of safely.) When using the handset, make sure that you are pointing it at the window of the cassette fire. 2

USER INSTRUCTIONS 3. CLEANING AND MAINTENANCE ALWAYS UNPLUG FROM MAINS SUPPLY BEFORE CLEANING OR UNDERTAKING ANY MAINTENANCE 3.1 Fan heater - clean the air inlet (front and underside) and outlet grilles regularly with a soft cloth or the nozzle of a vacuum cleaner. Dust build-up will inhibit efficient movement of the fan and can lead to the safety cut-out operating. 1 a b AR1658 3

INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATIONS THESE INSTRUCTIONS COVER THE FOLLOWING MODELS: 8590SLELR This appliance has 3 modes of operation a) flame effect only b) flame effect + 1kw heating c) flame effect + 2kw heating This appliance will accept all frames which are suitable for the gas Riva 67 with balanced flue A 240v 13amp 50Hz supply is required. THIS APPLIANCE MUST BE EARTHED A lead and plug are supplied. SITE REQUIREMENTS 1. OPENING DIMENSIONS 2. CASSETTE DIMENSIONS 2 3 535 mm 568 mm 655 mm 665 mm See Page 5, 1.3 680 mm 525 mm 105 mm AR1659 105 mm AR1660 4

INSTALLATION INSTRUCTIONS 1. INSTALLATION INSTRUCTIONS 1.1 Unpack the fire, remove all packaging and read any warning labels carefully. Packaging should be disposed of at an appropriate recycling centre. 1.2 Check that the fire s voltage requirements are in accordance with your electricity supply. Do not plug in/switch on at this stage. 1.3 Place the fire into position, ensuring the plug will reach the socket. Please note, depending on your wall type, the opening may need extra clearance around the flex socket area. 1.4 Secure the flanges of the fire to the wall by using the 9 screws and rawlplugs supplied. NOTE: some frames are particularly heavy and the fire needs to be securely fastened to the wall. Depending on the structure of the wall, different fixings from those provided may be necessary. 2. FAULT FINDING 2.1 If there is no illumination of log effect, first change the 13amp fuse for one, which you know, works. If the fire still does not work, check the socket by plugging in an appliance you know is working. Check the appliance flex plug is securely inserted into the appliances socket. If this too fails to operate, call in a competent electrician to check the socket. 2.2 Illumination but no heat - the safety cut-out has operated to protect against overheating. See note in Operating Instructions above but, in particular; ensure the air inlet and outlet grilles are free of dust or any other obstruction. 2.3 Remote control fails to work - First check that the batteries are new and correctly fitted. Ensure that the handset is pointing at the window of the cassette fire and that it is being 5

INSTALLATION INSTRUCTIONS 5. HOW TO WIRE A PLUG 4 UK Plug Supplied Earth wire Live wire 5 Typical European Plug Live wire Neutral wire Fuse Neutral wire Earth wire Outer Insulation Cable grip Outer Insulation Cable grip Live wire Brown Terminal Marked L / coloured RED Neutral wire Blue Terminal Marked N / coloured BLACK Earth wire Green and yellow stripes Marked E / / colour GREEN or GREEN & YELLOW If you need to change the plug supplied with this fire, follow the instructions below. The instructions assume that the wire has been cut WARNING FAILURE TO CONNECT THE WIRES CORRECTLY COULD PUT PEOPLE AT RISK FROM ELECTRIC SHOCK OR FIRE. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN. 1. Dispose of the old plug safely. 2. Expose 4cm of the coloured wires. Depending on the design of plug being used: Trim the coloured wires to the correct lengths so that they neatly fit to the correct terminals. Ensure that the Earth wire has more slack than any of the other wires. Remove some of the insulation to leave about 1cm of exposed metal core on each wire. Twist the strands of the wire together 3. To connect the wires to the correct terminals: Loosen the screw heads above each terminal Push the metal wire into the hole beneath each screw head 4. Ensure that the insulation reaches right up to each terminal as illustrated and there are no loose strands of wire. 5. Fit the flex firmly onto the cord-grip making sure that the grip fastens onto the plastic sleeve of the flex and tighten screws. 6. Read the technical specification in these instructions to see what rating of Fuse is required and fit the correct fuse in the plug 7. Fit the plug cover and make sure that the plug is not cracked or chipped. THIS APPLLIANCE MUST BE EARTHED Or, for other plug designs: - Wind the metal wire around the screw - Tighten each screw 6

Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group