APPLICATION DATA SHEET

Similar documents
APPLICATION DATA SHEET

IGD.CO.UK

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

APPLICATION DATA SHEET

P R O D U C T D ATA S H E E T

GAS DETECTION International Gas Detectors CH4 NO

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

SUPREMATouch. Modular Fire & Gas Detection System

P R O D U C T D ATA S H E E T

SUPREMATouch. Modular Fire & Gas Detection System

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

SUPREMATouch Modular Fire & Gas Detection System

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

2-WIRE SYSTEMS OLIVER IGD. 2-Wire. Version 3.2 T750-INST. Addressable. Triton House Crosby Street Stockport SK2 6SH England

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Industrial Grade Gas Detection Detecting The Difference

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

Touchpoint Pro Flexible Gas Control System

YOUR PARTNER IN FIRE & GAS DETECTION

MULTIFUNCTIONAL SYSTEM

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Industrial Grade Gas Detection

A New Standard of Excellence

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

Industrial Grade Gas Detection

/8 DIN Level Indicator

Two-Channel Gas Controller

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

IntesisBox BACnet/IP Server - Notifier ID3000 series

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

Danfoss gas detection unit Type GD Heavy Duty

Zareba System Overview

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Labkotec Ice Detector

Vocia VACIE. Reference Guide

Gas Controller Module GC-06

Detection, Protection, Innovation

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Remote alarm indicator and test combination MK2430

Zareba Metro Gas Detector

Products and performance

Touchpoint Plus. A whole new control experience

VACIE REFERENCE GUIDE REVISION 1.2.6

SenSmart Universal Gas Detector Series

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Substation Monitoring System

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Dräger Polytron 8000 Stationary gas detector (EC)

5000 Series Rack Panels

Process Alarm Module RTA 421

Dräger REGARD -1 Control System

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

RAYCHEM NGC-30 COMPONENTS

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

General Routing Interface

Solution F2. Fire Alarm Control Panels one step ahead.

P R O D U C T D ATA S H E E T

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Dependable Solutions for Gas Detection

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

BC3250. Blowdown Controller

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Fire and Gas Monitoring Panel ST7-HV

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

Monitoring Solutions

Danfoss gas detection units

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Oxygen (O2) Single-Point Gas Detection System

Recalibrate the way you look at gas detection

Gasmonitor+ Installation, Operation and Maintenance Manual

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

System 57. An advanced World of intelligent gas detection system management

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Operating Instructions

Danfoss gas detection Controller unit

3M Oldham MX 43 Controller

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

The EN54 Part 2 & 4 Fire System

RTD TEMPERATURE SENSING SYSTEM

For Complete Fire and Gas Solutions

Networked Access Control Panel. Installation Guide

Transcription:

APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors - Latest Colour Touch Screen HMI Interface - Integrate Other Signal Inputs - One Man calibration Function - Fully Accessible Modbus, Bacnet, Ethernet Interface - Use as a Host Unit In Conjunction With Tocsin 700 - WAV File Audible Alarms C o n t r o l u p t o 2 5 0 A d d r e s s a b l e G a s D e t e c t o r s Excellent Value Gives you lots of control and configuration for a low price. Large Possibilities. Allows you to connect with up to 250 devices on multiple highways Connects with all Oliver detectors You can integrate any 4-20mA or switched input device onto the system Ultimate Flexibility Highway and relay connections can be distributed where you need them, either at the controller. or around the site. Software and/or PC interface allows easy channel setup and alarm programming with full. Cause & Effect tables Easy to maintain Unique walk zero and calibration tests allow one man set up of large detection systems. Full detector diagnostics Ultimate Control Integrate to BMS or DCS systems Bacnet or Modbus Options LAN Ethernet Option 2 Ref O920-1

SERVICE LABEL WARNING DO T OPEN Ltd, 4a Pepper Rd WARNING DO T OPEN Ltd, 4a Pepper Rd WARNING DO T OPEN Ltd, 4a Pepper Rd WARNING DO T OPEN Ltd, 4a Pepper Rd WARNING DO T OPEN Ltd, 4a Pepper Rd WARNING DO T OPEN Ltd, 4a Pepper Rd TOCSIN 920 Ethernet LAN Options RS232/485 Comms Link To Host Systems, SCADA, BMS etc via MODBUS or similar 8 Volt Free Relay Contact Outputs As Standard Expandable Audio Visual Units Available Relay Output Nodes For Local Alarm or Control Up to 32 Detectors Flammable or Toxic Gases Per Loop 110/230 VAC 0r 24V DC Power Options Battery Back Up Units Available Connect RS485 Ports to Act as a Host For Tocsin 700 Series Control Panels. See the Same Detectors Connected to The Tocsin 700 on The Tocsin 900 OP1 OP2 OP3 OP4 SYSTEM FAULT Compatible With Tocsin 103, 102 or 903 Series Detectors. TOCSIN 103A DETECTOR 0-50ppm FOR SERVICE NTACT XXXXXX TOCSIN 103A DETECTOR 0-50ppm FOR SERVICE NTACT XXXXXX 8 off RS485 Ports. Use as Either Double Ended (Looped Back) or Single Ended Cable Runs TOCSIN 103A DETECTOR 0-50ppm FOR SERVICE NTACT XXXXXX 24V DC SUPPLY Any Mix of Detectors, Flammable, Toxic, Oxygen and Relay Outputs Power Boosters To Cater For Long Cable Runs 700 ATEX or Safe Area Detectors 2 Ref O920-1

Typical system Block Diagram Base Systems Comprise: Touch Screen HMI Panel 150W PSU One Data Highway Hub One Addressable Relay Output Card. Typical Screen Shot, Tocsin 920 Series HMI Display. Touch Screen 260,000 Colours, 800 x 480, 7 Display. Tocsin 920 Series Control Panel (panel mount version) 4 Core Cable Highway Data Highway Hub. 8 Ports Serving Up To 32 Devices Up to 32 Addressable Detectors, Relay Output Nodes, Cards or Signal Input Nodes Per Data Highway Note the Maximum Number of System Devices Per Tocsin 920 is 250 8 Port Hubs and Relay Cards can bechassis or DIN Rail Mounting for inclusion into OEM cabinets. All Devices are 24V DC Powered. Field boxes are available for in field installation of Hubs and relay cards if required. 8 Output Addressable Relay Card 8 Output Addressable Relay Card 2 Ref O920-1

1 9 " R a c k M o u n t O p t i o n 483.0 2 133.4 920 ADVANCED GAS DETECTION SYSTEM Tocsin 920 Rack mount Units Are Standard 19 Rack Modules 3U High (133.35mm) 240.0 All electrical Terminations are to the Rear of the Rack W a l l M o u n t O p t i o n Bottom 105 61 CH4 H2S 2 SO2 2 Front SYSTEM DESIGNATION SERVICE LABEL 328 Side USB PORT A D VA N C E D I N T E L L I G E N T H A Z A R D O U S G A S D E T E C T I O N S Y S T E M TOCSIN 920 520 Top 35 Mounting flanges either side dia 4.5mm holes 505 x 180mm 20mm Entry Hole Knock Outs Std Weight 9KG 2 Ref O920-1

W a l l M o u n t i n g I n t o a C a v i t y For flush mounting into wall recesses/cavities the following detail indicates correct installation. If the following detail is adhered to the front cover of the Tocsin 920 will overlap the edge of the cavity. Cavity Detail 80 Typically Drill 7mm For Wall Plugs (Brown) and 5mm Screws 61 Bottom 180 32 19 Cable Entries Top or Bottom Wall Section 2 Ref O920-1

D I N R a i l M o u n t e d H i g h w a y H u b D i m e n s i o n s D I N R a i l M o u n t e d R e l a y C a r d D i m e n s i o n s 2 Ref O920-1

S p e c i f i c a t i o n Power Source Power Consumption 200 Watts Base Unit (system dependant) Display Colour HMI 800x480 Operating Temperature 0 c to 55 c Operating Humidity 5 to 95% non-condensing Accuracy Sensor dependant Resolution 0.00% 0.00ppm Dependant on Sensor Type Update Rate 1 Second Size (mm) 365 (H) x 533 (W) x 110 (D) Wall Mounting Version 3U High Rack Mounting Version Inputs Up to 8 x RS485 loops (Expandable Using Additional Hubs) Outputs (Standard) 8 x configurable SP relays (7A non conductive load Expandable. using Additional relay Cards) 1 x RS232/485 Comms Link (Modbus/Bacnet) CE Declaration O r d e r C o d e s 5920101 5920102 5920201 5920301 5920401 5920501 5920601 5920701 5920801 5920901 5921001 BS EN 61000-6-4 EMC Compatibility 'Emissions' for industrial environments BS EN 61000-6-2:2001 EMC 'Immunity' for industrial environments BS EN 61010-1: 2001 Safety requirements for electrical equipment Tocsin 920 Wall Mount Base Unit Tocsin 920 Panel Mount Base Unit (For OEM Integration) Tocsin 920 19 Rack Mount Base Unit Modbus Option Bacnet Option (TBA) Addressable Relay Card 8 SP Relays For Use in Base Units Addressable RS485 Hub 8 RS485 Ports For Use in Base Units Addressable Relay Card 8 SP Relays DIN Rail Mounting Addressable RS485 Hub 8 RS485 Ports DIN Rail Mounting Field Box. Field wall mounting enclosure to accommodate two cards, as either relays or hubs Battery Backup Module 5921101 2 DIN Rail Mount 24V DC PSU Module Hesd office : Saenchote Electric Instrument co., Ltd. Ref O920-1 Tel. : 662-193-2432 Fax.: 662-193-2438 E-mail : chotsaksei_p@hotmail.com Wed : www.saenchotesei.com