PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Similar documents
GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

Surface Mount Ambient Light Sensor PTAS-P1F1708CH6. Features. Descriptions. Applications. Device Selection Guide

SMT450. High Performance TOP LED

Reverse Package Infrared LED IR25-21C/TR8

Specification MBT801-S

Technical Data Sheet 3mm Phototransistor T-1

EVERLIGHT ELECTRONICS CO.,LTD.

Technical Data Sheet 5mm Phototransistor T-1

Technical Data Sheet 1.5mm Side Face Infrared LED

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 1.6mm Side Looking Phototransistor

1. These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do not re

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

Preliminary specification

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

NIDS Dust sensor ED-N-DS-1408

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

2 / These specification sheets include materials protected under copyright of Sharp Corporation ("Sharp"). Please handle with great cares and do

PRODUCT SPECIFICATION

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

ULTRA FAST RECITIFIERS

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION

SMD 2121 Black Frame MC-S2121BHA

Technical Data Sheet Opto Interrupter ITR

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

FEBL8511_REFBOARD_Manual-01 ML FC. REFERENCE BOARD Manual for UV Sensor (QFN)

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

No. STSE-CC7186A <Cat.No > SPECIFICATIONS FOR NICHIA CHIP TYPE UV LED MODEL : NCSU034A(T) NICHIA CORPORATION -0-

1N4001 THRU 1N4007 1N4001 THRU 1N SILICON RECTIFIER. Features:

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

LASER DIODE NX7637BF-AA

PRODUCT SPECIFICATION

APPLICATION NOTES for LED DISPLAYs

HEP Tech Co., Ltd. Company Profile

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

Applications PL- N Series Lens Type Sensor Type Serial Number

Optical Sensors. ROHM Semiconductor USA, LLC 1

Fortimo LED Line Gen2 Module

Operating Instructions

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Application Notes For LED Displays

Fortimo LED Line High Flux Module

Shen hen ormand Electronic Co.Ltd

SENSOR SWITCH. OncQue Corporation 大日科技股份有限公司. Item No. RBS07 Series Description TILT SWITCH Version 13 Page 1 of 16 Date Nov. 04, 2013 FUNCTIONS

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

Piezoelectronic Buzzers

NX7535 Series DESCRIPTION NX7535AN-AA FEATURES NX7535BN-AA

ETH1000-MKII. User manual

Nichia STS-DA1-0456A <Cat.No > SPECIFICATIONS FOR NICHIA CHIP TYPE GREEN MODEL : NHSGC08T NICHIA CORPORATION

Pyroelectric Infrared Sensors

Pyroelectric Infrared Sensors

Wideband Optical Couplers

Evaluation Board Information

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Mounting Instruction

ELLA ID. High CRI, High lm/w OptoDrive LED-module

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Features. Figure 1. Recommended Application

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Multi Layer Varistor Overvoltage Protection Device

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

Reference Specification

Specification Status: Released

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

HFX Fiber Optic Component 50 Mbps, 650 nm LED

EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

FEATURES ORDERING CODE EMCP C 100 N T (1) (2) (3) (4) (5) (6) (7) SMT Multilayer EMI Filter (Power Line) TRIGON COMPONENTS

RECOMMENDABLE CONDITION OF SOLDERING

ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Dual SDI Optical to Electrical Converter

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

SENSOR SWITCH BRAVOTRONICS CORPORATION 松瓚科技股份有限公司. Item No. VBS080100T Description VIBRATION SWITCH Version 8 Page 1 of 10 Date Nov.

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

Electrical Configuration: Two single sensing elements and two compensating elements are connected to built-in FET in source follower circuit,

Infrared Sensors Line Guide

SF100 User Manual Version 1.0

onlinecomponents.com

The UAE RoHS regulation covers all EEE (Electrical and Electronic Equipment) as detailed in Table 1.

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

Class 1 laser beam sensor safe for your eyes

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Transcription:

PD100MF0MPx Surface Mount Type, Opaque Resin Photodiode Features 1. Compact and thin SMD package 2. Top view and side view mountable 3. Plastic mold with visible light cut-off black resin lens 4. Peak sensitivity wavelength: 850 nm TYP. 5. Narrow directivity angle (Δθ: ±20 TYP.) 6. Lead free and RoHS directive compliant Model Line-up Model No. Packaging Mount Direction PD100MF0MP 2000 pcs/reel Side view PD100MF0MP1 1500 pcs/reel Top view Agency Approvals/Compliance 1. Compliant with RoHS directive (2002/95/EC) 2. Content information about the six substances specified in Management Methods for Control of Pollution Caused by Electronic Information Products Regulation (popular name: China RoHS) (Chinese: ); refer to page 6. Applications 1. Office automation equipment 2. Audio visual equipment 3. Home appliances 4. Telecommunication equipment 5. Measuring equipment 6. Tooling machines/factory automation 7. Touch Panels Notice The content of data sheet is subject to change without prior notice. In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. 1 Date: November 30, 2007 SHARP Corporation

External Dimensions 3.0 2.8 2.2 0.75 (0.35) 1.5 Viewed from PCB (Side view Mounting) 0.4 2.2 1.0 (0.2) 0.65 0.95 (0.4) 1.5 R0.8 3.0 1.5 (0.70) 1.4 (0.57) (0.92) 1 2 Terminal connection 1.1 Viewed from PCB (Top view Mounting) 1.5 3.0 1.1 1.1 1 2 (1.0) (1.0) Pin Arrangement 0.85 1.7 NOTES: 1. Unit: mm 2. Unspecified tolerance: ±0.2 mm 3. ( ): Reference dimensions 4. Au plated area 5. Do not allow circuit runs in area 6. Any resin burrs are not included in the outline dimensions No. 1 2 Name Anode Cathode 1.1 (Center of lens) 2

Absolute Maximum Ratings (Ta = 25 C) Parameter Symbol Rating Unit Reverse voltage V R 20 V Power dissipation P 75 mw Operating temperature Topr -30 to +85 C Storage temperature Tstg -40 to +95 C Soldering temperature *1 Tsol 240 C * 1 Within 10 s (MAX.) see reflow profile in Fig. 4. Electro-optical Characteristics (Ta = 25 C) Parameter Symbol Conditions *1 MIN. TYP. MAX. Unit Short circuit current I SC Ev = 100 lx 0.4 0.6 0.8 µa Dark current Id V R = 10 V, Ev = 0 10 na Terminal capacitance Ct V R = 15 V, ƒ = 1 MHz 10 pf Peak sensitivity wavelength λp 850 nm Response time (Rise) tr 10 ns V R = 15 V, R L = 180 Ω Response time (Fall) tf 10 ns Half intensity angle Δθ ±20 degrees 1 Ev: Irradiance by CIE standard light source A (tungsten lamp) * Fig. 1 Power Dissipation vs. Ambient Temperature Power dissipation (mw) 80 75 70 60 50 40 30 20 15 10 0-30 0 25 50 75 85 100 Ambient temperature Ta ( C) Fig. 2 Spectral Sensitivity (TYP.) Relative sensitivity (%) 100 90 80 70 60 50 40 30 20 10 0 400 500 600 700 800 Wavelength λ (nm) Ta = 25 C 900 1000 1100 3

Fig. 3 Radiation Diagram (TYP.) Ta = 25 C -30-40 -50-60 -70-80 -90-20 -10 0 +10 +20-90 +90 Relative radiant intensity (%) 100 80 60 40 0 20 Anode Cathode 0 Angular Displacement θ +30 +40 +50 +60 +70 +80 +90 Design Considerations Design Guidelines 1. This product is not designed to be electromagnetic- and ionized-particle-radiation resistant. Manufacturing Guidelines Soldering Instructions 1. Sharp recommends soldering no more than once when using solder reflow methods. 2. When using solder reflow methods, follow the reflow soldering temperature profile shown in Fig. 4. Sharp recommends checking the process to make sure these parameters are not exceeded; exceeding these parameters can cause substrate bending or other mechanical stresses leading to debonding of the internal gold wires, or other similar failure modes. 3. If using an infrared lamp to preheat the parts, such heat sources may cause localized high temperatures in the part's resin. Be sure to keep the temperature profile within the guidelines shown in Fig. 4. 4. If hand soldering, use temperatures 260 for 3 seconds. Do not dip-solder or VPS-solder this part. 5. Do not subject the package to excessive mechanical force during soldering as it may cause deformation or defects in plated connections. Internal connections may be severed due to mechanical force placed on the package due to the PCB flexing during the soldering process. 4

Fig. 4 Reflow Soldering Temperature Profile 240 C MAX. 200 C 165 C MAX. 1 to 4 C/s 1 to 4 C/s 1 to 4 C/s 25 C 120s MAX. 90s MAX. 10s MAX. 60s MAX. Cleaning Instructions 1. Confirm this device's resistance to process chemicals before use, as certain process chemicals may affect the optical characteristics. 2. Solvent cleaning: Solvent temperature should be 45 C or below. Immersion time should be 3 minutes or less. 3. Ultrasonic cleaning: The effect upon devices varies due to cleaning bath size, ultrasonic power output, cleaning time, PCB size and device mounting circumstances. Sharp recommends testing using actual production conditions to confirm the harmlessness of the ultrasonic cleaning methods. 4. Recommended solvent materials: Ethyl alcohol, Methyl alcohol, and Isopropyl alcohol. Storage and Handling 1. Store these parts between 5 C and 30 C, at a relative humidity of less than 70%. 2. After breaking the package seal, maintain the environment within 5 C to 25 C, at a relative humidity of less than 60%, and mount the parts within two days. 3. When storing the parts after breaking the seal, Sharp recommends storage of no longer than two weeks in a dry box or by resealing the parts in a moisture-proof bag with a desiccant. If unable to do so, bake before mounting. 4. When baking the parts before mounting, Sharp recommends baking the parts only once and only if in a metal tray or mounted on a PCB. Recommended conditions are for 16 to 24 hours, at a temperature of 125 C. 5

Presence of ODCs (RoHS Compliance) This product shall not contain the following materials, and they are not used in the production process for this product: Regulated substances: CFCs, Halon, Carbon tetrachloride, 1,1,1-Trichloroethane (Methylchloroform). Specific brominated flame retardants such as the PBBOs and PBBs are not used in this product at all. This product shall not contain the following materials banned in the RoHS Directive (2002/95/EC). Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB), Polybrominated diphenyl ethers (PBDE). Content information about the six substances specified in Management Methods for Control of Pollution Caused by Electronic Information Products Regulation (Chinese: ) Category Lead (Pb) mercury (Hg) Cadmium (Cd) Toxic and Hazdardous Substances Hexavalent chromiun (Cr 6+ ) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Photo Diode NOTE: indicates that the content of the toxic and hazardous substance in all the homogeneous materials of the part is below the concentration limit requirement as described in SJ/T 11363-2006 standard. Taping Specifications 1. Tape structure and dimensions conforms to those shown in Fig. 5 to Fig. 10. 2. Product insertion will have the cathode to the hole side of the tape. 3. Cover tape peel-separation force: F = 0.2 to 1.0 N (where θ 160 to 180 ) 4. Quantity per reel = 2000 pcs. (PD100MF0MP) or 1500 pcs. (PD100MF0MP1) 5. Product mass: 0.01 g (approx.) 6. Packaging: a. Reels are sealed inside an aluminum bag, along with a humidity indicator card. b. Bags are labeled and securely packed. 6

Packing Specifications PD100MF0MP (Side view mount, 2000 pcs/reel) Fig. 5 Tape Shape and Dimension 4.0 ±0.1 1.75 ±0.1 2.0 ±0.05 φ1.5 +0.1 0.3 ±0.05 5 5.5 ±0.1 1.7 ±0.1 3.3 ±0.1 3.5 ±0.05 8.0 ±0.3 1.75 ±0.1 4.0 ±0.1 1.6 ±0.1 2.5 ±0.1 Fig. 6 Reel Shape and Dimension 2.0 ±0.5 φ13.0 ±0.2 9.0 +0.3 60.0 +1 180.0 11.4 ±1 NOTE: Unit: mm 7

Fig. 7 Product Insertion Direction Pull-out direction PD100MF0MP1 (Top view mount, 1500 pcs/reel) Fig. 8 Tape Shape and Dimension 4.0 ±0.1 2.45 ±0.1 2.0 ±0.05 φ1.5 +0.1 0.3 ±0.05 5 5.5 ±0.1 3.3 ±0.1 3.5 ±0.05 8.0 ±0.3 1.75 ±0.1 4.0 ±0.1 1.8 ±0.1 8

Fig. 9 Reel Shape and Dimension 2.0 ±0.5 f13.0 ±0.2 9.0 +0.3 60.0 +1 180.0 11.4 ±1 NOTE: Unit: mm Fig. 10 Product Insertion Direction Pull-out direction 9

PDS100MF0MP1 Important Notices The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP s devices. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: --- Personal computers --- Office automation equipment --- Telecommunication equipment (terminal) --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics (ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliabilty such as: --- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) --- Traffic signals --- Gas leakage sensor breakers --- Alarm equipment --- Various safety devices, etc. (iii) SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: --- Space applications --- Telecommunication equipment (trunk lines) --- Nuclear power control equipment --- Medical and other life support equipment (e.g. scuba) If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Law of Japan, it is necessary to obtain approval to export such SHARP devices. This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. Contact and consult with a SHARP representative if there are any questions about the contents of this publication. 10