STOCKIST OF LINEAR HEAT SESNING CABLE in INDIA

Similar documents
AlarmLine Linear Heat Detector

ThermoCable Linear Heat Detection System

ALARMLINE ANALOGUE Linear Heat Detection System

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Reference Guide 2.1. Certificate Number

Linear Heat Detection for Coal Conveyors. Application Guide

AlarmLine Addressable Linear Heat Detector

Installing Protectowire Linear Heat Detector

Alarmline II Digital Linear Heat Sensor Cable Technical Manual

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

LINEAR HEAT SENSING DETECTION. System Sensor India 2014

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

LDM-519-DIM LHDC MONITOR Digital Line Heat Detector Interface

Linear Heat Detection

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

COMPANY PROFILE Technoswitch is an ISO 9001:2015 certified company that designs, manufactures, imports and sells high quality fire detection and contr

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

CHECKFIRE 210 Detection and Actuation System

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Linear Heat Detection Cable - Monitor

Alarmline Linear Heat Detection

Simply the Best For Your Home Comfort. Unlimited Supply of Hot Water

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

Commercial and Light Industrial Fire Alarm Control Panel

Flexible Air-sampling Smoke Detection

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

Sophisticated. io-series Intelligent fire alarm solutions for small buildings. An EDWARDS brand.

The PBE Group. Industries We Serve. PBE Catalogue

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Linear Heat Detection Engineering Specifications

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Building Services Brochure

Aspirating smoke detection

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Intelligent Detection Devices

Carbon Film Installation Instructions

ALARMLINE ANALOGUE LINEAR TEMPERATURE DETECTION

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Heat Sensor Cable Alarm Units DT650L / DT950L

Basic Vehicle Fire Protection Manual

5900 Series X-in Low Energy Power Operator

Flexible Power Cable DLO

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

Tether and Umbilical Cables for Remotely Operated Vehicles

5900 SERIES Low Energy Power Operator

DETECT-A-FIRE Heat Detectors

1SC-SSC Splice Connection Kit Installation Instructions

Model 5610 Infra-red Transit Heat Sensor

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Tempra / DHC-E. Simply the Best. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control ENGINEERING EXCELLENCE

and Aspirating Smoke Detection

Viega Fire Protection Systems. Safety starts here

Line Smoke Detector LRMX

FlexGuard Glassbreak Detectors. The First Line of Defence

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

XL-Trace System Application and Design Guide

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

An introduction to... Sigma

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Reinforced FBG Sensors Serve Demanding Applications

Alarmline II Analogue Linear Heat Sensor Cable Technical Manual

RELAY. Digital Slickline System INTELLIGENT SLICKLINE CONVEYANCE FOR WELL INTERVENTION

Searchpoint Optima Plus

Liquid Helium Level Instruments

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

Tempra TM / DHC-E Simply the Best. Engineering Excellence. The Finest Tankless Electric Water Heater Available!

TTSIM-1 Sensor Interface Module

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

i.net Engineered system solutions for

HUMIDITY MANAGEMENT MODULE TYPE H122 Digital USER INSTRUCTIONS

BlazeMaster Fire Sprinkler Systems

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

I T A L I A N T E C H N O L O G Y C O N S T R U C T I O N ENGLISH

Interfacing Fire Alarm, Sprinkler and Elevator Systems

The A-series Eletta Flow Monitor with local indication and analog output

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions

ENGINEERING. Product Overview #AR-OV-11a

AUTOCALL FIRE DETECTION SYSTEMS.

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Touchpoint Pro Flexible Gas Control System

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Skin-Effect Heat-Tracing System (STS)

Versatile. EST3X Life Safety Solutions. An EDWARDS brand.

DIPL Solutions and Services

INTRINSICALLY SAFE S314X AND S315X

Data Sheet. Self regulating heating tapes. RS stock numbers

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS

Transcription:

We at FIRE KNOCK the pioneers and Distributor of LINEAR HEAT SENSING CABLE & market leaders in Fire Safety & Security Systems for more than three decades having our Head office in Mumbai. FIRE KNOCK is a trusted name in the market for our commitment to world class quality, competitive pricing, strong technical support & prompt Customer Service. We have gained immense experience in the technology apart from engaging experienced manpower - technocrat & commercial, to understand the risk area we offer right from Basic Designing, Value Engineering, Commissioning Support, Trouble Shooting and Training Support. Understanding the needs of the customer and giving them appropriate solutions; under a single roof has always been the principle at FIRE KNOCK. Please find the details of LINEAR HEAT SENSING CABLE AS UNDER: STOCKIST OF LINEAR HEAT SESNING CABLE in INDIA Linear Heat Detectors

Description: Linear Heat Detector, the main component of our linear heat detection systems, is a proprietary cable that detects heat conditions anywhere along its length. Available in a range of alarm temperatures and jacket models to suite a vast array of fire detection applications Principles: The primary mechanism of heat (fire) detection is that inner core insulating polymer is specially formulated such that it plasticizes at a specific temperature. The cable is constructed such that the twisted steel cores are in tension, and at the polymer trigger temperature the conductors connect. This provides an alarm signal to any associated monitoring device. The LHDC may be used as a simple switch to operate a relay etc. However in most fire alarm installations the minimum requirement is that the LHDC circuit is monitored for disconnections by means of an End Line (EOL) device and an appropriate Fire Alarm Channel or Address Loop interface unit. LHS CABLE can provide more sophisticated monitoring schemes that can discriminate and identify Zone / Area alarm initiations whilst maintaining a single length of LHDC. The LHS Digital Linear Heat Detectors are designed to provide early detection of fire conditions and overheating in circumstances where other forms of detection would not be viable, either due to inability to sustain the environmental requirements or through prohibitive costs. Extensive single zonal lengths of the Linear Heat Detector (LHD) may be installed with the ability to trigger alarms for hot spots occurring on very small sections of the overall cable. The LHDC may be employed in a wide variety of applications but is particularly suited where there is a harsh environmental condition, a physical or hazardous maintenance access constraint to the protected area, and/or requirements to cost effectively install detection in close proximity to the risk(s) The Key features are:- Early detection of hazards at temperatures well below flame point Rugged construction for use in harsh environments. Ease of installation - wide range of fixings available. Compatible with many existing zone monitors / control equipments. Fixed Alarm Trigger Temperature Intrinsically Safe configurable for Hazardous Areas. Compliant with industry standards Extensive range of proven applications. UL Approved, ULC LISTED

Construction: The sensor cable is comprised of two steel conductors individually insulated with a heat sensitive polymer. The insulated conductors are twisted together to impose a spring pressure between them, then wrapped with a protective tape and finished with an outer jacket suitable for the environment in which the Detector will be installed. Application: LHDC is versatile in that it can both provide an alternative to point heat detectors in conventional (space) protection situations and it may also be readily installed in very close proximity to monitored hazards. The detector is particularly suited to applications where harsh environmental conditions preclude the use of other forms of detection. The low maintenance requirement of the detector provides a unique solution to fire detection in areas that have access restrictions due to either physical difficulties or personnel health risk. The cable may be installed in Hazardous Areas by means of Intrinsically Safe Zener Barriers. When the protected area is remote from the monitoring equipment interposing cables may be employed. Linear Heat Detector is made in multiple temperature ratings to allow for differences in normal or ambient temperature. Guidelines for selecting the proper detector temperature rating are the same as for automatic sprinklers and other heat actuated devices. Refer to the Temperature Rating Chart for proper model selection based upon installation temperature limits. The Detector s product range consists of four distinct types of cable. Each designation identifies a specific outer jacket material which has unique characteristics that have been selected to accommodate the widest range of installation environments.

Linear Heat Detector Application Areas: CABLE GALLERY CONVEYORS

FLOATING ROOF TANKS WAREHOUSE

TUNNELS CAR PARKING

ESCALATORS FIXED ROOF & SPHERE TANKS

The Alarm Point Location Meter An exclusive feature of Fire System control panels, the alarm point location meter is designed to locate a heat actuated point on a length of Linear Heat Detector. The Meter provides a means to display the alarm point location, represented as a linear distance in Feet or Meters, from the start of the 0portion of the circuit to the heat actuated alarm point on the detector. Alarm Point Location Setup: Each zone is field calibrated after installation to eliminate copper feed cable resistance from the Alarm Point Location reading. This is done by manually shorting the detector at the beginning of the zone and adjusting the display to zero "0000". Zone Mapping: When a Linear Heat Detection System using the Alarm Point Location Meter is first brought online, points along the detector correlating to a floor plan or installation detail can be temporarily shorted an measured. Each distance reading can then be marked on the floor plan or detail at it's corresponding point. In the future, a reading of the Alarm Point Location Meter can be referenced on the floor plan or detail, making location of the overheated (alarm) portion of the wire easier to locate.

Accessories: Our company offers an assortment of fasteners and splicing devices to facilitate installation for both standard and special applications. Full details are available upon request. For Further Information please feel free to Contact Rahul Asher +91-9867064498 / +91-9821665744. Keshavji Jadhavji Trust Bldg., Office No. 86, 2nd Floor, 112 Yusuf Meherali Road, Masjid Bunder (W), Mum - 400 003. Tel: +91-22-2345 4498 Email: fireknock09@gmail.com Web: www.fireknock.com