Air Conditioners (Outdoor)

Similar documents
TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Commercial High-Efficiency Condensing Units

TECHNICAL SPECIFICATIONS

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Table of Contents AIR CONDITIONING EQUIPMENT

WCH5**4. Product Specifications

PACKAGE AIR CONDITIONER

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

PRODUCT SPECIFICATIONS

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

R4H4. Product Specifications

Product Data. Fig. 1 - Unit 50VR -A

Commercial High-Efficiency Condensing Units

R4H4. Product Specifications

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Split System Cooling Product & Performance Data

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

N4H4. Product Specifications

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Split System Cooling Product Data

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Ruud Achiever Series Air Conditioners

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Split System Cooling Product Data

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

RSG16**S1M. Split System Air Conditioner 16 SEER

TECHNICAL SPECIFICATIONS

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

HIGH EFFICIENCY AIR CONDITIONERS napoleonheatingandcooling.com

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Ruud Ultra Series Variable Speed Heat Pumps

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MAC-120HE-03 Air-Cooled Chiller

SCE170 SERVICE PARTS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

HIGH EFFICIENCY AIR CONDITIONERS 13 SEER. Engineered and Made in Canada. napoleonheatingandcooling.com

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Split System Cooling Product Data

User s Information and Installation Instructions

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

AMERICAN STANDARD 14 MODELS 4A7B E

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

14 AC x

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

AIR COOLED PACKAGED CHILLER

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

EMI ENGINEERING SUBMITTAL

AND WORRY-FREE PERFORMANCE

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product Data

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Split System Cooling Product Data

Split System Heat Pump Product Data

Specifications and Performance S2H

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

MAC N-407 Air-Cooled Chiller

INSTRUCTIONS! DO NOT DISCARD!

Split System Cooling Product Data

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

EMI ENGINEERING SUBMITTAL

Split System Cooling Product Data

INSTALLATION AND OPERATING INSTRUCTIONS

N4A6. Product Specifications

Self-Contained Reverse Cycle Air Conditioners

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

PAJ3. Product Specifications

WJH4 Product Specifications

AND WORRY-FREE PERFORMANCE

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Transcription:

22/04/16 A1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Copeland Scroll Compressor Micro-channel all aluminum coils have high corrosion resistance Swept-wing fan blade reduces unwanted noise PSC, permanently lubricated motor Removable top grill assembly and louvered condenser guard Complete metal wrapper to protect the condenser coil High pressure switch with auto reset Easy compressor and control access Liquid line filter drier included Composite base pan absorbs sound and is corrosion resistant 16 SEER Models Also Feature: Comfort Alert TM Module; detects system and electrical problems Copeland Scroll Ultra Tech TM Compressor Low pressure switch with auto reset Ton HP Model Part 13 SEER 1 1/2 1/8 FS4BD018KB 921083F 2 1/8 FS4BD024KB 920601F 2 1/2 1/8 FS4BD030KB 920602F 3 1/4 FS4BD036KB 920603F 3 1/2 1/4 FS4BD042KB 921084F 4 1/4 FS4BD048KB 921085F 5 1/4 FS4BD060KB 921086F 16 SEER 2 1/4 FS4BF024KA 919646F 2 1/4 FS4BF024KB 921794F 3 1/4 FS4BF036KA 919647F 3 1/4 FS4BF036KB 921768F 4 1/3 FS4BF048KC 921654F 5 1/3 FS4BF060KC 921993F 13 SEER Dimensions FS4BD 018KB 024KB 030KB 036KB 042KB 048KB 060KB H 24 1/4" 24 1/4" 28 1/4" 28 1/4" 29" 29" 33" W 23 1/4" 23 1/4" 23 1/4" 23 1/4" 31 1/4" 31 1/4" 31 1/4" D 23 1/4" 23 1/4" 23 1/4" 23 1/4" 31 1/4" 31 1/4" 31 1/4" 16 SEER Dimensions FS4BF 024KA 024KB 036KA 036KB 048KC 060KC H 45" 33" 45" 37" 41" 45" W 31 1/4" 22 3/4" 31 1/4" 30 3/4" 30 3/4" 30 3/4" D 31 1/4" 22 3/4" 31 1/4" 30 3/4" 30 3/4" 30 3/4" WARRANTY ON FRIGIDAIRE AIR CONDITIONERS 10 Year Parts: 10 years on all parts when product is registered, 5 years when not registered 10 Year Comfort Quality Pledge: Replacement of entire unit if compressor fails within the first 10 years from installation date when registered, 1 year when not registered (must be matched Frigidaire condenser & coil to qualify) Warranty Registration: Register your system within 60 days of installation Extended Warranty Protection: Ask your Davies Rep for specific details on labor protection plans

22/04/16 A1-1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Copeland Scroll Compressor Composite base pan absorbs sound and is corrosion resistant PSC, permanently lubricated motor Removable top grill assembly High pressure switch with auto reset Liquid line filter drier Easy compressor and control access Complete metal wrapper to protect the condenser coil All aluminum Micro-Channel Coils, provides high corrosion resistance Ton HP Model Part 13 SEER 2 1/8 JS4BD024KB 920601J 2 1/2 1/8 JS4BD030KB 920602J 3 1/4 JS4BD036KB 920603J 3 1/2 1/4 JS4BD042KB 921084J 4 1/4 JS4BD048KB 921085J 5 1/4 JS4BD060KB 921086J 13 SEER Dimensions JS_BD 024K 030K 036K 042KB H 27 1/2" 27 1/2" 35 1/2" 27 1/2" W 22 3/4" 22 3/4" 22 3/4" 30 3/4" D 22 3/4" 22 3/4" 22 3/4" 30 3/4" 048KB 060KB 27 1/2" 31 1/2" 30 3/4" 30 3/4" 30 3/4" 30 3/4" WARRANTY ON PHILCO AIR CONDITIONERS 5 Years: Parts Coverage 10 Years: When Registered SEE WARRANTY DOCUMENTS FOR TERMS & CONDITIONS Warranty Registration: Register your system within 60 days of installation

03/10/14 A1-2 Air Conditioner Coils Cased Air Conditioner Coils - R-410A Refrigerant - TXV "A" Coil NOTE: Should Sell #01-1306 Filter Drier With Every TXV Coil See page A13-1 for complete filter drier listing Replacement TXV Assembly for C6 Cased Coils Fits C6 Coil Model Part C6BAX24C-A/B 920668 C6BAX30C-A/B/C 920669 C6BAX35C-A/B, C6BAX36C-B/ C, C6BAX37C-C 920670 C6BAX42C-B/C/D 920671 C6BAX48C-C/D 920672 C6BAX60C-C/D 920673 Ton Overall W x H Depth C6 Series Use with Condenser Model Part FS4BD018KA 1.5 or 2 14 1/4" x 20 3/74" 20 3/4" FS4BD024KA C6BAX24CA 920006 FS4BF024KA FS4BD018KA 1.5 or 2 17 1/2" x 20 3/4" 20 3/4" FS4BD024KA C6BAX24CB 920015 FS4BF024KA 2 17 1/2" x 26 3/4" 20 3/4" FS4BF024KA C6BHX24CB 920017 2.5 14 1/4" x 20 3/4" 20 3/4" FS4BD30KA C6BAX30CA 920024 2.5 17 1/2" x 20 3/4" 20 3/4" FS4BD030KA C6BAX30CB 920033 2.5 21" x 26 3/4" 20 3/4" FS4BD030KA C6BAX30CC 920551 3 17 1/2" x 20 3/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX35CB 920045 3 17 1/2" x 26 3/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX36CB 920054 3 21" x 26 3/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX36CC 920186 3 21 x 30 1/4" 20 3/4" FS4BD036KA FS4BF036KA C6BAX37CC 920885 3 17 1/2" x 26 3/4" 20 3/4" FS4BF036KA C6BHX36CB 920056 3 21" x 26 3/4" 20 3/4" FS4BF036KA C6BHX36CC 920188 3.5 17 1/2" x 26 3/4" 20 3/4" FS4BD042KA C6BAX42CB 920063 3.5 21" x 26 3/4" 20 3/4" FS4BD042KA C6BAX42CC 920072 3.5 24 1/2" x 30 1/4" 20 3/4" FS4BD042KA C6BAX42CD 920192 4 21" x 30 1/4" 20 3/4" FS4BD048KA FS4BF048KA C6BAX48CC 920081A 4 24 1/2" x 30 1/4" 20 3/4" FS4BD048KA FS4BF048KA C6BAX48CD 920090 5 21" x 30 1/4" 20 3/4" FS4BD060KA FS4BF060KA C6BAX60CC 920099 5 24 1/2" x 30 1/4" 20 3/4" FS4BD060KA FS4BF060KA C6BAX60CD 920108 See Page A3 for Complete Coil Information

03/10/14 A2 Air Conditioner Coils Uncased Air Conditioner Coils - R-410A Refrigerant - TXV "A" Coil C5 Coil NOTE: Should Sell #01-1306 Filter Drier With Every TXV Coil See page A13-1 for complete filter drier listing Replacement TXV Assembly for C6 Uncased Coils Fits C6 Coil Model Part C6BAX24U-A/B 669681 C6BAX30U-A/B/C 669682 C6BAX35U-A/B, C6BAX36U-B/ C, C6BAX37U-C 669683 C6BAX42U-B/C/D 669684 C6BAX48U-C/D 669852 C6BAX60U-C/D 669686 Ton Overall W x H Depth Use With Condenser Model Part C5 Series 5 21" x 28 3/4" 19 1/2" 060KA C5BAX60UC 919518D C6 Series 1.5 or 2 12 3/4" x 19" 19 1/2" FS4BD018KA FS4BD024KA FS4BF024KA C6BAX24UA 920007 1.5 or 2 16" x 19" 19 1/2" FS4BD018KA FS4BD024KA C6BAX24UB 920016 FS4BF024KA 2.5 12 3/4" x 19" 19 1/2" FS4BD030KA C6BAX30UA 920025 2.5 19 1/2" x 23 3/4" 19 1/2" FS4BD030KA C6BAX30UC 920552 3 16" x 24 3/4" 19 1/2" 3 19 1/2" x 23 3/4" 19 1/2" FS4BD036KA FS4BF036KA FS4BD036KA FS4BF036KA C6BAX36UB 920055 C6BAX36UC 920187 3 19 1/2" x 28 3/4" 19 1/2" FS4BD036KA FS4BF036KA C6BAX37UC 920884 3.5 16" x 24 3/4" 19 1/2" FS4BD042KA C6BAX42UB 920064 3.5 19 1/2" x 23 3/4" 19 1/2" FS4BD042KA C6BAX42UC 920073 3.5 23" x 24" 19 1/2" FS4BD042KA C6BAX42UD 920193 4 19 1/2" x 28 3/4" 19 1/2" 4 23" x 28 1/4" 19 1/2" 5 19 1/2" x 28 3/4" 19 1/2" 5 23" x 28 1/4" 19 1/2" C6 Coil FS4BD048KA FS4BF048KA FS4BD048KA FS4BF048KA FS4BD060KA FS4BF060KA FS4BD060KA FS4BF060KA C6BAX48UC 920082A C6BAX48UD 920091 C6BAX60UC 920100 C6BAX60UD 920109 See Page A3 for Complete Coil Information

25/02/11 A3 Air Conditioner Coils Coil Data Charts C6 TXV Cased Coil C5 TXV Uncased Coil C6 TXV Uncased Coil

04/05/12 A3-1 Air Conditioner Coils Vertical Cased Air Conditioner Coils - R-410A Refrigerant - "A" Coil Ton Overall W x H Depth Model Part C6 "A" Coils 5 24 1/2" x 30 1/4" 20 3/4" C6BAX60CC 920099 5 24 1/2" x 30 1/4" 20 3/4" C6BAX60CD 920108 C7 Vertical "A" Coils 1.5-2 14 1/2" x 20 3/4" 20 3/4" C7BAM01824C-A 921515 2.5-3 14 1/2" x 20 3/4" 20 3/4" C7BAM03036C-A 921517 1.5-2 14 1/2" x 20 3/4" 20 3/4" C7BAM01824C-B 921519 2.5-3 14 1/2" x 20 3/4" 20 3/4" C7BAM03036C-B 921521 3-3.5 17 1/2" x 26 3/4" 20 3/4" C7BAM03642C-B 921523 2-3 21" x 26 3/4" 20 3/4" C7BAM030C-C 921700 3-4 21" x 26 3/4" 20 3/4" C7BAM03648C-C 921525 3.5 24 1/2" x 30 1/4" 20 3/4" C7BAM042C-D 921529 4 24 1/2" x 30 1/4" 20 3/4" C7BAM048C-C 921838 4 24 1/2" x 30 1/4" 20 3/4" C7BAM048C-D 921841 NOTE: Should sell #01-1306 Filter Drier With Every Coil Frigidaire & Philco condensers come with Filter Drier See page A13-1 for complete filter drier listing See Page A3-4 for Complete Coil Information

04/05/12 A3-2 Air Conditioner Coils Horizontal Cased Air Conditioner Coils - R-410A Refrigerant - "A" Coil Ton Overall W x H Depth Model Part C7 Horizontal "A" Coils 1.5-2 14 1/2" x 20 3/4" 20 3/4" C7BHM01824C-A 921661 2.5-3 14 1/2" x 20 3/4" 20 3/4" C7BHM03036C-A 921662 1.5-2 14 1/2" x 20 3/4" 20 3/4" C7BHM01824C-B 921663 2.5-3 14 1/2" x 20 3/4" 20 3/4" C7BHM03036C-B 921664 3-3.5 17 1/2" x 26 3/4" 20 3/4" C7BHM03642C-B 921665 2-3 21" x 26 3/4" 20 3/4" C7BHM030C-C 921701 3-4 21" x 26 3/4" 20 3/4" C7BHM03648C-C 921666 4-5 21" x 30 1/4" 20 3/4" C7BHM04860C-C 921667 3.5 24 1/2" x 30 1/4" 20 3/4" C7BHM042C-D 921668 4-5 21" x 30 1/4" 20 3/4" C7BHM04860C-D 921669 NOTE: Should sell #01-1306 Filter Drier With Every Coil Frigidaire & Philco condensers come with Filter Drier See page A13-1 for complete filter drier listing See Page A3-4 for Complete Coil Information

24/05/13 A3-3 Air Conditioner Coils Uncased Air Conditioner Coils - R-410A Refrigerant - "A" Coil Ton Overall W x H Depth Model Part C6 Series 5 19 1/2" x 28 3/4" 19 1/2" C6BAX60UD 920109 C7 Series 1.5-2 12 3/4" x 18 1/2" 19 1/2" C7BAM01824U-A 921514 2.5-3 12 3/4" x 18 1/2" 19 1/2" C7BAM03036U-A 921516 1.5-2 16" x 18" 19 1/2" C7BAM01824U-B 921518 2.5-3 16" x 18" 19 1/2" C7BAM03036U-B 921520 3-3.5 16" x 25" 19 1/2" C7BAM03642U-B 921522 2.5 19 1/2" x 18" 19 1/2" C7BAM030U-C 921699 3-4 19 1/2" x 24 1/2" 19 1/2" C7BAM03648U-C 921524 3.5 23" x 23 3/4" 19 1/2" C7BAM042U-D 921528 4 19 1/2" x 28 1/2" 19 1/2" C7BAM048U-C 921837 4 23" x 27 3/4" 19 1/2" C7BAM048U-D 921840 C7 Series NOTE: Should sell #01-1306 Filter Drier With Every Coil Frigidaire & Philco condensers come with Filter Drier See page A13-1 for complete filter drier listing See Next Page for Complete Coil Information

04/05/12 A3-4 Air Conditioner Coils Coil Data Charts

04/05/12 A3-5 Air Conditioner Coils C6 Cased & Uncased "A" Coil TXV Kits C7 Uncased "A" Coil TXV Kits Tons Refrigerant Type Part 1.5-2 R-22 920662A 2.5 R-22 920663A 3 R-22 920664A 3.5 R-22 920665A 4 R-22 920666A 5 R-22 920667A 1.5-2 R-410A 920668A 2.5 R-410A 920669A 3 R-410A 920670A 3.5 R-410A 920671A 4 R-410A 920672A 5 R-410A 920673A

01/11/13 Air Conditioner Coil Wrappers & Close Off Kit A4 C5 Coil Wrappers For Uncased Coils Fits Cabinet Size Overall Width Overall Height Brand Part A 14 1/4" 20" Frigidaire 919330 B 19 3/4" 26" Frigidaire 919333 C6 & C7 Coil Wrappers For Uncased Coils Cabinet Identifier Overall Width (W) Overall Height (H) Liquid Line Height (HL) Suction Line Height (HS) Opening Width (OW) Brand Part C6 & C7 Coil Wrappers A 14 1/4" 20 3/4" 17 1/2" 15 1/2" 12 7/8" Frigidaire 920256 A 14 1/4" 26 3/4" 23 1/2" 21 1/2" 12 7/8" Frigidaire 920257 B 17 1/2" 20 3/4" 17 1/2" 15 1/2" 16 1/8" Frigidaire 920258 B 17 1/2" 26 3/4" 23 1/2" 21 1/2" 16 1/8" Frigidaire 920259 C 21" 26 3/4" 23 1/2" 21 1/2" 19 5/8" Frigidaire 920260 C 21" 30 1/4" 27" 25" 19 5/8" Frigidaire 920261 D 24 1/2" 30 1/4" 27" 25" 23 1/8" Frigidaire 920262 D 34" Frigidaire 920263 Close Off Kit For Cased Coils Description Kit for adapting a cased coil to a smaller width furnace. This could be either a C5 series coil with a narrower G7 furnace or a C6 series coil with a G6 or L1 furnace. Part 920316

17/01/14 A5 Air Conditioners Covers Air Conditioner Covers - Customized Logo Custom printed covers are a cost effective marketing tool that promotes your company to the homeowner and neighbors - a great source of new leads, referrals, callbacks and name recognition Logo printed in any one color in one location (side or top) Logo size: 8" x 14" Minimum order of 30 Custom printed covers are a cost effective marketing tool! Call Davies for more information! Air Conditioner Covers Attractive AC cover with a glove like fit Keeps dirt and debris out of condensing unit Heavy duty vinyl resists slipping or tearing and is also specially treated to protect against mold, mildew and UV rays Helps prevent corrosion of electrical contacts 1/2" gap at bottom provides cross-ventilation to provide air flow and prevent condensation Velcro strap easily secures cover around suction and discharge lines Size: L"xW"xH" Part 22 3/4 x 22 3/4 x 34 1/4 0084A 22 3/4 x 22 3/4 x 26 1/2 0084B 30 3/4 x 30 3/4 x 26 1/2 0085B 30 3/4 x 30 3/4 x 30 1/2 0085C 23 1/4 x 23 1/4 x 24 1/4 0655C 23 1/4 x 23 1/4 x 28 1/4 0655D 23 1/4 x 23 1/4 x 36 1/4 0655B 31 1/4 x 31 1/4 x 33 0656D 31 1/4 x 31 1/4 x 37 0656A 31 1/4 x 31 1/4 x 45 0656C Note: See AC Accessories Quick Pick Guide for model to cover chart

25/06/10 A6 Air Conditioner Accessories Brackets Heavy duty engineered steel brackets used for mounting A/C condensers and heat pumps on vertical walls Includes mounting holes and are finished in a durable grey powder coat Description Brand Part 30" Steel Bracket (pair) Mars 93630 36" Steel Bracket (pair) Mars 93631 42" Steel Bracket (pair) Mars 93632 Connectors - Liquid Tight, Non-Metallic Conduit - Liquid Tight, Non-Metallic PVC flexible connectors Indoor or outdoor use UV rated material for long outdoor life Reusable design Resists salt water, weak acids, gasoline, alcohol, oil, grease and most common solvents Size Description Brand Part 1/2" Straight Connector Mars 85016 3/4" Straight Connector Mars 85017 1/2" 90 o Connector Mars 85020 3/4" 90 o Connector Mars 85021 Rigid coils combined with flexible PVC construction provide superior wire protection Use on a large variety of AC, refrigeration and HVAC equipment Resilient to abuse, pulling or crushing Use with PVC liquid tight connectors Temperature range -18C to 75C (0F to 167F) Size Length Brand Part 1/2" 100' Mars 84118 3/4" 100' Mars 84119

03/10/14 A7 Air Conditioner Accessories Compressors Single and three phase replacement compressors 1 year limited warranty BTU Capacity Volts Phase Fits Model Brand Part Single Phase - Fits R22 10 SEER 16,300 208/230 1 FS3BA018KA Copeland 912969 22,100 208/230 1 FS3BA024KA Copeland 912956 28,200 208/230 1 FS3BA030KA Copeland 912957 34,400 208/230 1 FS3BA036KA Copeland 914955 38,200 208/230 1 FS3BA042KA Copeland 912958 45,200 208/230 1 FS3BA048KA Copeland 918788 58,300 208/230 1 - Copeland 911250 61,200 208/230 1 FS3BA060KA Copeland 914926 Single Phase - Fits R22 13 SEER 24,000 208/230 1 FS5BD024KA Copeland 921045 30,000 208/230 1 FS5BD030KA Copeland 921046 48,000 208/230 1 FS5BD048KA Copeland 921050 60,000 208/230 1 FS5BD060KA Copeland 921052 Three Phase 32,000 200/230 3 - Copeland 912967 35,000 200/230 3 - Copeland 913944 41,900 200/230 3 - Copeland 912962 56,300 208/230 3 - Copeland 911367 46,000 208/230 3 - Tecumseh 912777 Air Compressor Sound Blanket Simple cost-effective solution to compressor noise Cheaper than replacing or moving equipment Minimum 5 db or 40%+ reduction of compressor noise Fits well over 200 different models of compressor Works with either hermetic or scroll compressors Convenient easy to install universal-fit design Convenient hook and loop straps to simplify installation Description Brand Part Compressor Sound Blanket Brinmar SBUHD

25/06/10 Disconnect A8 Air Conditioner Accessories Line, load and ground terminals aligned for ease of wiring Side door opens 180 degrees for maximum access Full dead front Convertible door for left or right swing cul Listed Description Brand Part 60A Non-fusible disconnect switch Diversitech DDS-60U Equipment Pads - Ultralite Solid base gives five times more foundation surface than a plastic ribbed pad Lightweight Stays flat and stable, will not sink into the ground Retains strength and color in direct sunlight Vibration absorbing, it will not crack or chip Non slip surface Little or no ground preparation Limited lifetime warranty Size Weight lbs. Brand Part 26" x 28" x 2" 16 Diversitech UC2628-2 32" x 32" x 2" 22 Diversitech UC3232-2 36" x 36" x 2" 27 Diversitech UC3636-2 Evaporator - Anti-Ice Controls 18AEIC1 A30-2311 18AEIC1 Evaporator Coil Low Temperature Limit When attached to the suction line of the evaporator coil and wired in series with the Y connection to the compressor, its normally closed contact will shut down the refrigeration compressor when it senses the evaporator coil freezing up. 3/4" cup. A30-2311 Heat Pump Control Designed to be wired in series with the cycling control. The capillary senses the evaporator temperature and shuts the compressor off. When the temperature reaches 60 o F the contacts close and restart the unit. Capillary Length: 30" Temperature Setting Brand Part Opens Closes 2.8C (37F) 15C (59F) Alltemp 18AEIC1-1C (30F) 16C (60F) Robertshaw A30-2311

25/06/10 Fan Centres A9 Air Conditioner Accessories Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or air conditioning systems Transformer powers low voltage control systems and provides overload protection Mounts on standard 4" x 4" junction box Low voltage terminal board provides convenient connections for thermostat and heating, cooling equipment wiring R8285A10-48 8A05A-101 Motor Rating @ 120VAC Input Voltage Switching Action Full Load Locked Rotor Brand Part 40 VA, 60Hz SPDT 12.0A / 6.0A 35A / 72A Honeywell R8285A1048 120 VAC, 60Hz DPST 8.0A / 14.0A 48.0A / 84.0A White Rodgers 8A05A-101 Filter Driers - Liquid Line - Solder Type Standard used with most refrigerant/lubricant combinations High moisture removal capacity Very low pressure drop Filtration down to 10 microns Copper sweat connectors Powder coated finish is 1000 hours salt spray rated 500 psig safe working pressure Nominal Tons Inlet / Outlet Connection Overall Length Diameter Brand Part 1/3-2 3/8" ODF 4.5" 2" Frigidaire 01-1306 (053S) 1-4 3/8" ODF 5.37" 2.5" Frigidaire 01-0787 (083S) 2-5 3/8" ODF 6.06" 2.5" Frigidaire 01-1308 (163S) 2-5 1/2" ODF 6.06" 2.5" Frigidaire 01-0789 (164S)

25/06/10 Fittings- Nylon A10 Air Conditioner Accessories Nylon fittings for AC coil installations Description Size Part A coil adapter, 2/pack 1/2" Barb x 3/4" MPT 701-002 A coil adapter, 2/pack 5/8" Barb x 3/4" MPT 701-014 Drain hose elbow for ac coils, 2/pack 1/2" Barb x 3/4" MPT 701-020 Drain hose elbow for ac coils, 2/pack 3/4" Barb x 3/4" MPT 701-025 Drain hose elbow for ac coils, 2/pack 5/8" Barb x 3/4" MPT 701-028 Hard Start Kits Combination Start Relay, Start Capacitor & Motor Overload (32781 / 32741) -Designed to replace those components on a 115 volt single phase refrigeration compressor installed on a capillary tube system. -Factory wired (wiring diagram on the product label) -Leads have push-on terminals for easy installation -Compact & universal Combination Relay and Safety Timer (DST-6) -Offers a larger capacitor for severely hard-to-start compressors -500% torque multiplier -Can be used on all PSC single phase compressors -Automatically disconnects in 0.5 seconds if the compressor fails to start HP Volts Brand Part 1/12 to 1/5 HP 115 VAC Mars 32781 1/4 to 1/3 HP 115 VAC Mars 32741 1 1/2 to 10 HP 120 to 288 VAC Diversitech DST-6 DST-6 Low Ambient Control Low Ambient Control Temperature Setting Opens Closes Brand Part 7C (45F) 13C (55F) Alltemp 19-20601

12/05/17 Linesets A10-1 Air Conditioner Accessories For split system air conditioning applications Quick and easy field installation Length 25' 50' 25' 50' Liquid Line (Non-Insulated) Suction Line (Insulated) Insulation Thickness Part 3/8" 3/4" 3/8" LS383425 3/8" 3/4" 3/8" LS383450 3/8" 7/8" 3/8" LS387825 3/8" 7/8" 3/8" LS387850 Sight Glass Moisture Indicators Provides a quick visual diagnosis of refrigerant and moisture levels in the liquid line of a refrigeration or air conditioning system Features copper fittings to permit solder installation without disassembly Simple color comparison provides quick diagnosis Maximum working pressure: 500psig (35 bar, 3447 kpa) Maximum temperature: 60C (140F) Size 3/8" ODF 1/2" ODF Description Brand Part Solder connection, solid brass body Frigidaire 918727 Solder connection, painted solid brass body Frigidaire 918728 918727 918728

31/12/10 A10-2 Air Conditioner Accessories Copper Tubing Refrigeration Type "R" or "ACR" Certified to ASTM B 280 Soft, seamless and annealed for flexibility Description Coil Length Part 1/8" OD ACR Copper Tubing 50' CTR2X50 3/16" OD ACR Copper Tubing 50' CTR3X50 1/4" OD ACR Copper Tubing 50' CTR4X50 5/16" OD ACR Copper Tubing 50' CTR5X50 3/8" OD ACR Copper Tubing 50' CTR6X50 1/2" OD ACR Copper Tubing 50' CTR8X50 Sold By The 50' Coil 5/8" OD ACR Copper Tubing 50' CTR10X50 3/4" OD ACR Copper Tubing 50' CTR12X50 7/8" OD ACR Copper Tubing 50' CTR14X50 1 1/8" OD ACR Copper Tubing 50' CTR118X50 Tubing Insulation Flexible thermal insulation Will not absorb moisture over long periods of use Weather resistant High resistance to common corrosive chemicals Black, marked in blue ink Inside Diameter Wall Thickness Length Part 5/8" 3/8" 6' 7-3858 3/4" 3/8" 6' 7-3834 7/8" 3/8" 6' 7-3878 Whips - Liquid Tight, Non-Metallic Flexible conduit 10 AWG type THHN / THWN / MTW wire Installation Whips Include: Non-metallic liquid tight conduit and fittings (one straight, one 90 o ) and two reducing washers Size Length Exposed Wire On Each End Part 1/2" 4' 11" 84131 1/2" 6' 11" 84135 1/2" 6' 24" 11-6524

17/01/14 A10-3 Air Conditioner Accessories Davies stocks a wide selection of equipment and components for any air conditioning installation. Call Davies Experts On Controls. CPVC Tubing & Fittings Condensate Pumps Vinyl Tubing Copper Tubing Tubing Insulation Copper Fittings Fan Relays Definite Purpose Contactors Thermostats Thermostat Wire Fast Stat