L-BAND SATELLITE LEVEL MONITOR INSTALLATION MANUAL

Similar documents
3 T828 Initial Adjustment

Public Safety DAS Annunciator Panel

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

ANEMOMETER 4403-RF-BAT

ONTIME TIMER SPECIFICATION

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

MULTI-STAGE CHILLER CONTROL

Instruction Manual Model A

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

FLT93 Installation, Operation and Troubleshooting Guide

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

Gas Monitor 1A1 with DSI

Instruction Manual Model L2 RF Switch

ACCURATE ELECTRONICS INC

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Exit Stopper. STI-6400 Series

Ax60+ Multi-Gas. Service Manual

WM3000 WIRELESS MODULES

CP CP

June 10, 2002 DF C S2424

VEHICLE EXHAUST DETECTOR

Extended Range DUAL TEC Motion Sensor

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Centro-Matic Automated Lubrication Systems System Controls

Installation and Operating Instructions

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Product Specification

I/A Series 716C 1/16 DIN Temperature Controller

MANUAL RESET ALARM RELEASE

Secure the other corner. bracket using the remaining screw,

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Universal Gas Detector

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Beck. The differential pressure transmitter for air

TFD-1 Installation & User s Guide

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

INSTALLATION INSTRUCTIONS

SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL

Intrusion Outdoor Protection Perimeter

Carbon Monoxide Transmitter

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

INSTALLATION INSTRUCTIONS

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

Nardalert S3 TM Non-Ionizing Radiation Monitor

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

MODEL B2 INSTALLATION MANUAL

EC Series Wall Unit Humidifier

4 & 8-POINT ANNUNCIATORS Instruction Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

July 14, 1999 DF C-100.

Introduction. OM-THA2

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

EAS System RX Tuning Specification

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

PROFESSIONAL SOUND SYSTEMS. Programme 105 / 105T OPERATING MANUAL AND USER GUIDE 108 / 108T 205 / 205T 206 / 206T 406 / 406T.

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

GAS PLUS ALARM SYSTEM

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Model A1600 Series Annunciator

INSTRUCTION MANUAL A131 High Level Audible Warning System

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

METEOROLOGICAL INSTRUMENTS

Long Range Radio Alarm Transmitter

Service Manual Model 3163

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

DGS - Danfoss Gas Sensor Check / Calibration Procedure

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

Advanced Test Equipment Rentals ATEC (2832) Installation Note

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Set-Up Procedures. Before You Start

STRIKE GUARD DELIVERS:

Water Detection Controllers

EG-400 Fire Detection Monitor

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Power Supply Display Module PSDM. Installation and Operation Manual

Transcription:

SLM-771 L-BAND SATELLITE LEVEL MONITOR INSTALLATION MANUAL IB 6461-01

SLM-771 L-BAND SATELLITE LEVEL MONITOR DESCRIPTION The SLM-771 is an L-Band Satellite Level Monitor designed to detect measure and report the receiving level of any RF signal from 5MHz up to 2.5GHz. Use it for early warning of satellite dish and LNB signal degradation due to snow loading, bug & bird intrusions, dish misalignment due to wind or movement, and any increase in LNB loss for whatever reason. It will alert you to the signal reduction before a system failure occurs. FEATURES It has both visual and telemetry voltage outputs calibrated in db steps and an audible alarm with a relay contact for activation of external alarms or other equipment. The front panel LED indicators are calibrated in 1dB steps for accurate loss detection. A front panel control is used to set up the monitor and alarm level. The meter output has a voltage that changes 100mV per 1 db and is field adjustable for offset to match your telemetry transmission equipment. +/- 0.0 to 10 Volts is available at the meter output. The unit is fully RF shielded and can be mounted in the front or rear of your rack. UNPACKING AND INSPECTION Remove the equipment from the packing materials. The following materials should be supplied with each order. SLM-771 (Blue Box). Power Cube 24 VAC. 6 Position Screw Terminal Connector (may be attached). Rack Mount Angle Bracket (may be attached) or PMS7005A. SLM-771isb Page 1 of 4

PROGRAM JUMPER SELECTION Some of the features of the SLM-771 may be programmed before the physical installation of the unit. The unit is shipped from the factory programmed for the audible alert sounder J-1 jumper selected OFF, the telemetry meter Voltage jumper J-2 on +/- Voltage output with zero input level equaling 0 Volts and the J-3 alarm contact relay output set to N.O. Normally Open. To change the field programmable jumpers, remove the four screws at the outer most edges of the unit cover and lift up the lid. Inside you will locate the Jumpers marked as J-1, J-2, and J-3. J-1 Audible Alarm selector. If this jumper is set to ON the audible alarm will sound when the Red LED indicator turns on below the user set alarm level. This audible alarm will sound until the RF input signal rises above the user set alarm level. J-2 Telemetry Meter Voltage selector. This selector has two shunt type jumpers that will select any of three meter voltage outputs that correspond to the RF level being detected. The Voltage changes level at 100mV per db and can be adjusted or offset to match other equipment. You can select 0-10 Volts Positive, 0-10 Volts Negative, or +/- 0-10 Volts by moving the two jumpers as indicated. J-2 Position Output terminals 1-2 = 0-10 Volts Positive relative to ground. 3-4 = 0-10 Volts Negative relative to ground. 1-4 = +/- 0-10 Volts relative to ground. 2-3 = Both output terminals grounded. Note: Both 2 and 3 jumper positions provide a ground to the Screw terminal connector. SLM-771isb Page 2 of 4 J-3 Alarm Relay Output Selector.

When an alarm is triggered the internal relay will output a contact closure. That contact can be field programmed to be Normally Open N.O. or Normally Closed N.C. Move the jumper to the desired relay operation. No jumper on will select no continuity for the relay output. INSTALLATION Locate a convenient place in your rack and mount the unit using the handy Rack Mount Angle Bracket. WARNING: This product is designed for indoor use only and if it is to be used outdoors it must be mounted in a water tight enclosure. First attach the 24VAC power supply to the screw terminals marked (24 VAC). CAUTION: connecting the 24 VAC to any other terminals on the unit will cause damage to the unit or the power supply. Next attach the L-Band RF signal from your signal splitter or distribution amplifier output to the input F connector labeled (RF INPUT). Then connect the Meter output terminals to your telemetry equipment. Next connect the Relay terminals to any external equipment that you need to operate when an alarm occurs. SLM-771isb Page 3 of 4 SET-UP

There are several ways that you can set up the alarm level to match your RF signals. One way is to use an attenuator to simulate signal loss. Because the unit is connected to a split off or distribution amplifier feed of the original signal you can attenuate the signal without degrading your ON AIR signal chain. Introduce a loss equal to the level you wish to have your alarm operate at using an attenuator between the signal source and the SLM-771 RF input. Then rotate the front control marked LEVEL SET counter clockwise until the RED alarm LED on the front panel turns on. This will set the alarm level to match the level created by the attenuator. Then remove the attenuator and the display will go up indicating proper operating level and the GREEN LED should be on indicating your level is a minimum of 3 db above the alarm level. Another way to set the front control is to use a variable attenuator ahead of the distribution amplifier and set the attenuation level until you just begin to get errors in the receiver equipment (just at threshold) then back off the attenuator the amount you want to use for your margin. Then set the front control until the RED LED just turns on indicating an alarm condition. When you remove the attenuator from the feed the SLM-771 will go back into the GREEN showing good signal strength. You can set the unit without the use of an attenuator. Just input your signal source and adjust the front control until the green LED lights up and your alarm will be 3dB down from that level. You can also make adjustments on this control at any time to lower the alarm threshold during adverse weather or snow loading conditions to fine tune the setting. TELEMETRY METER CALIBRATION You may adjust or offset the Meter Voltage output to match other equipment by opening removing the top lid and adjusting the control marked VR2 METER CAL. By measuring the voltage at the meter output terminals while adjusting the VR2 control you can set this voltage to coincide with any RF level within its range. Adjusting this control will not change any other setting on the device. You can return this to factory settings by terminating the RF input and adjusting VR2 to read zero at the terminal outputs. MAINTENANCE Other than VR2 there are no adjustments or calibration required inside the SLM-771. SLM-771isb Page 4 of 4